Skip to content

Penguin Chillers Cold Therapy Chiller & Tub

SKU Cold Therapy Tub & Chiller Package-1
Original price $2,499.99 - Original price $2,869.98
Original price
$2,499.99
$2,499.99 - $2,869.98
Current price $2,499.99
Availability:
in stock, ready to be shipped
Availability:
in stock, ready to be shipped
Availability:
in stock, ready to be shipped

Get it between -

Warranty Options: No Thanks
Profile Pic

Have a question? Talk to one of our trusted experts today!

Instant Live Chat: Chat IconChat Now

Call or Text us: Phone Icon 415-481-4075

Price Match Policy

Price Match

Here at OffGrid Living Solutions, we want to offer you the best prices online.

If you happen to find a lower price for the same product, we will guarantee to match their price or beat their price. Note, this does not apply to all products in the store. Please reach out to us via email or chat if you want a price match or price beat.

For the policy to apply, please send us a screenshot, link, or any other evidence of the product being priced lower than ours before making the purchase.

Refer to our Price Match Policy Rules.

Refunds & Returns Policy

At OffGrid Living Solutions, we are proud to have the best refund and return policies in the industry. If you’re not satisfied with your purchase for any reason, you may return it to us within 30 days for a refund.

If you have a problem with our order (there are missing components, damages, or the product is not functioning), please reach out to us as quickly as possible. Some of the problems can be resolved by going through the product manual or the product FAQs.

Refer to our Refunds & Return Policy for more details.

Shipping & Delivery

Order Processing

Once we receive your order, we will send you a confirmation email. Then we will process the order by confirming that the product is in stock and ready for shipment. If any of the items in your order are back-ordered, we will reach to you via email or phone and you may choose to either wait or receive a 100% refund.

Please allow 1-3 days for processing your order.

Shipping

We ship to the lower 48 continental United States only at this time.

Shipping times and shipping method will depend on the specific product and brand you purchase. If you have any shipping question, feel free to ask on the chat or email us at info@offgridlivingsolutions.com.

We will send tracking information by email the same day the shipping tracking number is created/available.

Before you sign the shipping bill, please THOROUGHLY INSPECT YOUR ITEM. Signing for the receipt of a damaged product removes the liability of the shipping company and OffGrid Living Solutions. Once you accept your shipment as non-damage, your item is your property.

Delivery time

Shipping Timeline listed above is an estimate. Please call or message the web chat for precise ETAs.

Penguin Chillers Cold Therapy Chiller & Tub

Description

Effortless Cold Therapy for Maximum Benefits

Whether you are new to cold therapy or a seasoned pro, you probably love the benefits of cold therapy, but not the hassle of managing ice. Keeping an ice bath cold with ice alone can be a burden. Our Cold Therapy Chiller & Tub package eliminates this issue by maintaining the cold temperature effortlessly thus allowing for more consistent and frequent usage, maximizing the benefits of your cold therapy routine.

Efficient Cooling Performance

Our chiller can reach temperatures in the low 40°F range and even down into the high 30°F under optimal conditions, though reducing external heat sources will improve the chiller’s performance. Ambient temperatures and sun exposure significantly affect the heat load on a cold therapy tub. Even in full sun or less-than-ideal conditions, maintaining a low to mid-40°F temperature is achievable with this setup.

Outdoor Use

The Cold Therapy Chiller can be used outdoors in all weather conditions, except freezing temperatures. So, to keep your unit functioning properly, be sure to disconnect and drain the chiller completely if the ambient temperatures drop to freezing or below to prevent damage.

Cost-Effective Operation

Operating the Cold Therapy Chiller & Tub is more affordable than most expect. At $0.12/KWh, the monthly cost of operation is around $18-$28. The compressor and fan only activate when cooling is needed, and once the water reaches the set point, they turn off, leaving only the low-wattage pump running.

Product Specifications

Penguin Chillers Cold Therapy Chiller & Tub Product Specifications

Specification Details
Chiller Type 3/4HP High Efficiency Chiller
Cooling Capacity 7,500 BTU/hr
Noise Level 65 dBA
Power Requirements 110 – 120 Volts / 450 Watts / 3.9 Amps
Dimensions 14”W x 20”D x 12”H
Weight 49 lbs
Built-in Pump Yes
Power Cord 10′ with GFCI protection
Weather Protection Rain Proof* (*Disconnect chiller and drain completely when ambient temperatures are at or below freezing to prevent damage)
Warranty 1-Year Product Warranty
Manufacturing Location Proudly made in the USA

What's in the box?

  • 100-gallon tub (53″ x 31″ x 26″ external / 47″ x 25″ x 26″ internal)
  • Attached filter canister with 150-micron washable/reusable filter
  • Inline screen – coarse filter to catch hair and large debris before the chiller
  • 3/4HP Cold Therapy Chiller with a built-in pump
  • Quick connect hoses

Product Manual

Penguin Chillers Cold Therapy Chiller & Tub Product Manual

Installation and Maintenance Tips

For best results, do not place the chiller in an area that cannot get wet, as both the chiller and tubing will produce condensation. Additionally, if you ever notice your system lacks flow or if you are unsure about the flow rate, immediately unplug the chiller and contact support at support@penguinchillers.com.

Strong water flow is crucial for any application requiring a water chiller because insufficient flow can cause water to freeze inside the chiller, leading to potential damage. Damage caused by improper setup or maintenance is not covered under the manufacturer’s warranty.

Setting Up Your Chiller

Ideally, keep the water cold at all times so to control bacteria, reduce maintenance, and keep it clean longer. Power savings from using a timer are minimal ($3-$5/month) compared to continuous operation costs ($18-$28/month). Using a timer requires more frequent water and filter changes, negating any savings, additionally, frequent power cycling adds wear and tear to the pump, increasing the risk of failure.

Penguin Chillers Cold Therapy Chiller Owners Manual

Product Warranty

Penguin Chillers Warranty

Product FAQs

Penguin Chillers Product FAQs

1) Can my chiller be installed and used outside?

  • Cold Therapy Chillers: These can be used indoors and outdoors, except in freezing conditions.
  • Standard Water Chillers: Not intended for outdoor use at all.
  • Commercial Chillers: Excluding the all-in-one Commercial Water Chiller, these are ready for outdoor use, regardless of the elements.

2) Can I use a Standard Water Chiller for cold therapy?

While the temperature range of our standard water chillers might be suitable for some cold therapy applications, we generally advise against it for a few reasons:

  • Durability Concerns: Standard water chillers are not specifically designed for the use in outdoor environments and so the rigors of cold therapy applications could lead to damage on internal components.
  • Missing Pump: Additionally, unlike our Cold Therapy Chiller, standard water chillers don’t have built-in pumps.

 

Safer and More Effective Cold Therapy Solution:

We recommend considering our dedicated Cold Therapy Chiller for several reasons:

  • Built for Cold Therapy: It’s specifically designed to survive outdoors except in freezing conditions.
  • Integrated Pump: The built-in pump ensures proper water circulation for optimal cold therapy effectiveness.

3) How do I prevent damage to my chiller?

  • Regular Filter Cleaning: Cleaning the filter weekly helps maintain proper water flow and prevents ice buildup.
  • Maintain Proper Water Levels: Ensure your chiller has the recommended water level so that it maintains optimal performance.
  • Avoid Running the Chiller Dry: Never run your chiller without sufficient water flow. If the water level is low, it can lead to internal damage to the heat exchanger.

4) How often should I clean my Penguin Chiller filter?

We recommend checking and cleaning your Penguin Chiller filters about once a week. Even if the filters appear clean, built-up debris can restrict water flow to the heat exchanger.

Why is cleaning the filter important?

Restricted water flow can cause the water in the heat exchanger to freeze. The expanding ice can crack the heat exchanger, leading to damage from lack of upkeep, which is not covered by warranty. Regular cleaning helps prevent this issue, so your chiller will operate efficiently for years to come.

5) Do Penguin Chillers have built-in pumps?

With the exception of the Cold Therapy Chiller, none of Penguin Chillers’ chillers have built-in pumps. Chillers are used in various setups, so customers should choose the pumps needed for their specific project.

6) What size or type of pump should I use?

  • Water chillers: We recommend pumps between 500 gph and 1,800 gph to achieve a minimum flow rate of 250 gph.  Submersible pumps are commonly used for their simplicity. Pump size should compensate for factors like pipe length, fittings, and head height, so Penguin Chillers offers Danner water pumps ranging from 500 gph to 3600 gph.
  • Glycol chillers: Space limitations might restrict pump options, so Penguin Chillers recommends specific glycol pump lines that work well with their units.
  • Commercial water chillers: A measurable flow rate of 1,200 gph to 2,500 gph is recommended, but the pump size can vary depending on the application.

7) What's the lowest temperature my chiller can reach?

This is a common question, but there’s no one-size-fits-all answer. It depends on several factors:

  • Water Chillers: We recommend not running them continuously below 37°F. During testing, we reached 36°F with 5 gallons of water. Factors like your target temperature, liquid amount, and ambient conditions all affect how low your chiller can achieve.
  • Glycol Chillers: Similar to water chillers, the lowest temperature depends on various factors. We recommend not running them continuously below 5°F, However in testing (with no heat load), we reached -15°F.

8)  Do Penguin Chillers have built-in tanks?

  • Water Chillers: No, they don’t. Their internal piping holds less than half a gallon of water.
  • Glycol Chillers: Standard models have reservoirs ranging from 1.25 to 3 gallons. Stainless Steel XL models have 8-30 gallon reservoirs, and commercial units have a 30-gallon reservoir. Check individual product details for specifics

9) How loud are Penguin Chillers?

Our chillers operate at a relatively quiet level. Most customers find them quieter than expected, but specific sound ratings (DBA) are available on each product page.

10) How much heat does a chiller put out?

Chillers remove heat from one area (liquid) and then release it into the surrounding air. So, the amount of heat released depends on how much heat needs to be removed from the liquid. It’s difficult to give a direct answer, but proper ventilation is crucial for efficient chiller operation

11) Does my chiller need ventilation?

Yes! Chillers need ventilation for proper heat transfer. If they’re in a confined space, such as a cabinet, then they won’t function correctly. Ventilation allows excess heat to dissipate so your chiller will continue running efficiently.

12) Why did my fermenter's cold crash stall at 40-50F?

Several reasons could explain this:

  • Chiller malfunction: If your chiller maintains its set point and cycles normally, then it’s likely not the culprit. However, if it runs constantly and can’t reach the desired temperature, contact Penguin Chillers technical support for assistance.
  • Heat transfer issue: If heat isn’t being pulled away from your product (e.g., beer) fast enough and transferred to the glycol, this could be the issue.
  • Frozen glycol: A stall during cold crashing is actually often caused
    by the glycol mixture being too cold. If your glycol is too cold, it can freeze your product, creating an insulating layer that prevents proper heat transfer. To solve this, raise the glycol temperature for a few hours so it can melt any ice buildup.

Common operating temperatures:

  • Glycol chiller: 28°F. Colder temperatures might freeze your product. If 28°F is still too cold, raise the glycol temperature to 30°F-32°F. Alcohol content in your product might also require a slightly higher setting. Avoid testing with water only.
  • Other factors: Glycol level, flow rate, or incorrect temperature reading could also be issues. Contact Penguin Chillers technical support for troubleshooting help