{"product_id":"blue-sea-7622100-ml-acr-charging-relay-12v-500a-w-manual-control-deutsch-connector-7622100","title":"Blue Sea 7622100 ML ACR Charging Relay 12V 500A w\/Manual Control  Deutsch Connector [7622100]","description":"\u003ch2\u003e\u003cspan style=\"text-decoration: underline;\"\u003eBlue Sea 7622100 ML ACR Charging Relay 12V 500A w\/Manual Control  Deutsch Connector [7622100]\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch2\u003eDescription\u003c\/h2\u003e\n\u003cp\u003e500 Amp magnetic latching (bi-stable) relay automatically combines batteries during charging and isolates batteries when discharging and when starting engine.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eManual control switch provides an added level of safety allowing control with or without power, and offering LOCK OFF capability for servicing\u003c\/li\u003e\n\u003cli\u003eAutomatically manages the charging of two large battery banks\u003c\/li\u003e\n\u003cli\u003eAllows paralleling of battery banks for emergency starting\u003c\/li\u003e\n\u003cli\u003e500 Ampere continuous rating to support high-output alternators\u003c\/li\u003e\n\u003cli\u003eMagnetic Latch (ML)—ACR draws very low current (\u0026lt;40mA to monitor terminal voltage) in the \"ON\" or \"OFF\" states, and draws moderate current for very short time when changing state\u003c\/li\u003e\n\u003cli\u003eDual sensing—senses charge on both battery banks\u003c\/li\u003e\n\u003cli\u003eStart Isolation (SI)—can be configured for temporary isolation of House loads from Engine circuit during engine cranking to protect sensitive electronics\u003c\/li\u003e\n\u003cli\u003eEngine Isolation (EI)—can be configured for isolation of two engines while both are running to protect engine electronics and maximize alternator output\u003c\/li\u003e\n\u003cli\u003eSenses charging on two battery banks\u003c\/li\u003e\n\u003cli\u003eLED output to remotely indicate when batteries are combined, isolated, in voltage lockout, or in Start or Engine isolation\u003c\/li\u003e\n\u003cli\u003e3\/8\"-16 tin-plated copper studs for maximum conductivity and corrosion resistance\u003c\/li\u003e\n\u003cli\u003e7\/8\" (22mm) stud length accepts multiple cable terminals\u003c\/li\u003e\n\u003cli\u003eSilver alloy contacts provide high reliability for switching live loads\u003c\/li\u003e\n\u003cli\u003eLabel recesses for circuit identification\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eProduct Specifications\u003c\/h3\u003e\n\u003ch2\u003e\u003cspan style=\"text-decoration: underline;\"\u003eBlue Sea 7622100 ML ACR Charging Relay 12V 500A w\/Manual Control  Deutsch Connector [7622100] \u003cmeta charset=\"utf-8\"\u003eProduct Specifications\u003c\/span\u003e\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eControl Circuit Connection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDeutsch DTM \/ Amphenol ATM (retail units: tinned wires)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNominal Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManual Control\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes (provides added safety with LOCK OFF capability)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEngine Isolation Condition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes – Two engines running:• One relay open, one relay closed• Engine 1 \u0026amp; 2 batteries isolated to protect electronics\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e#10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStart Assist Condition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes – Relay closed combining batteries to share power for low start battery\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStart Isolation Condition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes – Relay open isolating batteries to protect sensitive electronics\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmperage Operating Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e13mA @ 25°C nominal VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmperage Operating Current (Changing State)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;7.0A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTerminal Stud Torque\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e140 in-lb (15.82 Nm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eContinuous Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e500A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIntermittent Rating (5 min)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e700A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCranking Rating (30 sec)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1450A DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCable Size to Meet Ratings\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 × 4\/0 AWG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLive Current Switching\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e300A @ 12V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSwitching Cycles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100,000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTerminal Ring Diameter Clearance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.18 in (29.97 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTerminal Stud Length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.50 in (38.1 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTerminal Stud Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\/8\" - 16 (M10)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRelay Contact Position Voltages\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCombine 30 sec: 13.5VCombine 90 sec: 13.0VOpen 10 sec: 12.35VOpen 30 sec: 12.75VOpen High: 16.2V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/productimageserver.com\/prop65\/6pt.png\" alt=\"Warning\"\u003e\u003cstrong\u003eWARNING:\u003c\/strong\u003e This product can expose you to chemicals including di(2-ethylhexyl)phthalate (dehp) which is known to the State of California to cause cancer, birth defects or other reproductive harm. For more information go to \u003ca href=\"http:\/\/P65Warnings.ca.gov\"\u003eP65Warnings.ca.gov\u003c\/a\u003e.\u003c\/p\u003e\n\u003ch3\u003eProduct Manual\u003c\/h3\u003e\n\u003ch4\u003e\n\u003cmeta charset=\"utf-8\"\u003e\n\u003ca href=\"https:\/\/d2pyqm2yd3fw2i.cloudfront.net\/files\/resources\/technical_briefs\/Technical_Brief_ML-Series_FAQ_Matrix.pdf\" target=\"_blank\"\u003eML-ACR Troubleshooting Guide\u003c\/a\u003e\n\u003c\/h4\u003e\n\u003ch4\u003e\u003ca href=\"https:\/\/d2pyqm2yd3fw2i.cloudfront.net\/files\/resources\/instructions\/980035700-001-ML-ACRs.pdf\"\u003eBlue Sea Instructions\u003c\/a\u003e\u003c\/h4\u003e\n\u003ch3\u003eProduct Warranty\u003c\/h3\u003e\n\u003ch2\u003e\u003cspan style=\"text-decoration: underline;\"\u003eBlue Sea Systems Product Warranty\u003c\/span\u003e\u003c\/h2\u003e\n\u003cdiv id=\"top_bar\"\u003e\n\u003cp\u003eBlue Sea Systems stands behind its products for as long as you own them. Blue Sea Systems will replace or issue a credit for any of its products found to be defective in materials or manufacture. P12 Battery Chargers, P12 Remote Displays, BatteryLink Chargers, Sure Eject AC Disconnects, M2 OLED Digital Meters and Mini OLED Digital Meters are warranted for a period of five years from the date of first purchase. \u003c\/p\u003e\n\u003cp\u003eAll other Digital Meters are warranted for a period of three years from the date of first purchase. No compensation will be allowed for products not returned to Blue Sea Systems for analysis, nor will compensation be made for labor required to replace any defective product. Please contact\u003cspan\u003e \u003c\/span\u003e\u003ca href=\"mailto:conductor@bluesea.com\"\u003eCustomer Service\u003c\/a\u003e\u003cspan\u003e \u003cmeta charset=\"utf-8\"\u003e\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003efor an RMA number prior to shipping any product back to Blue Sea Systems.\u003c\/p\u003e\n\u003cdiv id=\"footer_container\"\u003e\n\u003cdiv id=\"footer\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003eProduct FAQs\u003c\/h3\u003e\n\u003cp class=\"styles_question__sQciu\"\u003eN\/A\u003c\/p\u003e\n\u003c!--- cis2:m2lsnZdp ---\u003e","brand":"Blue Sea Systems","offers":[{"title":"Default Title","offer_id":51023458894107,"sku":"OGL-81426","price":289.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0724\/2026\/2171\/files\/81426XL.jpg?v=1757456836","url":"https:\/\/www.offgridlivingsolutions.com\/products\/blue-sea-7622100-ml-acr-charging-relay-12v-500a-w-manual-control-deutsch-connector-7622100","provider":"OffGrid Living","version":"1.0","type":"link"}