{"product_id":"blue-sea-7622-ml-series-heavy-duty-automatic-charging-relay-7622","title":"Blue Sea 7622 ML-Series Heavy Duty Automatic Charging Relay [7622]","description":"\u003ch2\u003e\u003cspan style=\"text-decoration: underline;\"\u003eBlue Sea 7622 ML-Series Heavy Duty Automatic Charging Relay [7622]\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch2\u003eDescription\u003cbr\u003e\n\u003c\/h2\u003e\n\u003cp\u003e\u003cmeta charset=\"utf-8\"\u003e500 Amp magnetic latching (bi-stable) relay automatically combines batteries during charging and isolates batteries when discharging and when starting engine\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eManual control switch provides an added level of safety allowing control with or without power, and offering \"Locked Off\" capability for servicing\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eIncludes ML-Series Remote Control Contura Switch PN 2146 \u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e500 Ampere continuous rating \u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eMagnetic Latch (ML)-ACR draws very low current (\u0026lt;10 mA to monitor terminal voltage) in the \"ON\" or \"OFF\" states, and draws moderate current for very short time when changing state \u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eStart Isolation (SI)-Can be configured for temporary isolation of House loads from Engine circuit during engine cranking to protect sensitive electronics \u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eEngine Isolation (EI)-Can be configured for isolation of two engines while both are running to protect engine electronics and maximize alternator output \u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eSenses charging on two battery banks \u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eSupports high-output alternators up to 500 Amps \u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eLED output to remotely indicate when batteries are combined, isolated, in voltage lockout, in Start or Engine isolation \u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e3\/8\"-16 tin-plated copper studs for maximum conductivity and corrosion resistance \u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e7\/8\" (22mm) stud length accepts multiple cable terminals \u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eLabel recesses for circuit protection \u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eSilver alloy contacts provide high reliability for switching live loads\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cmeta charset=\"utf-8\"\u003e\u003ciframe src=\"https:\/\/www.youtube.com\/embed\/s_oKQ_N8_EY\"\u003e\u003c\/iframe\u003e\u003c\/p\u003e\n\u003ch3\u003eProduct Specifications\u003c\/h3\u003e\n\u003ch2\u003e\u003cspan style=\"text-decoration: underline;\"\u003eBlue Sea 7622 ML-Series Heavy Duty Automatic Charging Relay [7622] Product Specifications\u003c\/span\u003e\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eValue\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl Circuit Connection\u003c\/td\u003e\n\u003ctd\u003eTinned Wire\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Voltage\u003c\/td\u003e\n\u003ctd\u003e12V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManual Control\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEngine Isolation Condition\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStart Assist Condition\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStart Isolation Condition\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003e#10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmperage Operating Current\u003c\/td\u003e\n\u003ctd\u003e13mA @ 25°C nominal VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmperage Operating Current (changing state)\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;7.0A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerminal Stud Torque\u003c\/td\u003e\n\u003ctd\u003e140 in-lb (15.82 Nm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIntermittent Rating (5 min)\u003c\/td\u003e\n\u003ctd\u003e700A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCranking Rating (30 sec)\u003c\/td\u003e\n\u003ctd\u003e1450A DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum Operating Temperature\u003c\/td\u003e\n\u003ctd\u003e-10°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Operating Temperature\u003c\/td\u003e\n\u003ctd\u003e60°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Size to Meet Ratings\u003c\/td\u003e\n\u003ctd\u003e4\/0 AWG x 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLive Current Switching\u003c\/td\u003e\n\u003ctd\u003e300A @ 12V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStud Material\u003c\/td\u003e\n\u003ctd\u003eTinned Copper\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSwitching Cycles\u003c\/td\u003e\n\u003ctd\u003e100,000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerminal Ring Diameter Clearance\u003c\/td\u003e\n\u003ctd\u003e1.12 in (28.45 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerminal Stud Length\u003c\/td\u003e\n\u003ctd\u003e1.50 in (38.1 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerminal Stud Size\u003c\/td\u003e\n\u003ctd\u003e3\/8\"-16 (M10)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWire Size\u003c\/td\u003e\n\u003ctd\u003e20 AWG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelay Contact Position - Combine (30 sec)\u003c\/td\u003e\n\u003ctd\u003e13.5V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelay Contact Position - Combine (90 sec)\u003c\/td\u003e\n\u003ctd\u003e13.0V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelay Contact Position - Open (10 sec)\u003c\/td\u003e\n\u003ctd\u003e12.35V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelay Contact Position - Open (30 sec)\u003c\/td\u003e\n\u003ctd\u003e12.75V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelay Contact Position - Open High\u003c\/td\u003e\n\u003ctd\u003e16.2V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e2.06 lb (0.93 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/productimageserver.com\/prop65\/6pt.png\" alt=\"Warning\"\u003e\u003cstrong\u003eWARNING:\u003c\/strong\u003e This product can expose you to chemicals including di(2-ethylhexyl)phthalate (dehp) which is known to the State of California to cause cancer, birth defects or other reproductive harm. For more information go to \u003ca href=\"http:\/\/P65Warnings.ca.gov\"\u003eP65Warnings.ca.gov\u003c\/a\u003e.\u003c\/p\u003e\n\u003c!--- cis2:m2lsnZdp ---\u003e\n\u003ch3\u003eProduct Manual\u003c\/h3\u003e\n\u003ch4\u003e\n\u003cmeta charset=\"utf-8\"\u003e \u003ca href=\"https:\/\/d2pyqm2yd3fw2i.cloudfront.net\/files\/resources\/instructions\/990180180-005.pdf\" target=\"_blank\"\u003eBlue Sea Instructions\u003c\/a\u003e\n\u003c\/h4\u003e\n\u003ch4\u003e\n\u003cmeta charset=\"utf-8\"\u003e \u003ca href=\"https:\/\/productimageserver.com\/literature\/ownersManual\/34967OM.pdf\" target=\"_blank\"\u003eOwner's Manual (pdf)\u003c\/a\u003e\u003cmeta charset=\"utf-8\"\u003e\n\u003c\/h4\u003e\n\u003ch3\u003eProduct Warranty\u003c\/h3\u003e\n\u003ch2\u003e\u003cspan style=\"text-decoration: underline;\"\u003eBlue Sea Systems Product Warranty\u003c\/span\u003e\u003c\/h2\u003e\n\u003cdiv id=\"top_bar\"\u003e\n\u003cp\u003eBlue Sea Systems stands behind its products for as long as you own them. Blue Sea Systems will replace or issue a credit for any of its products found to be defective in materials or manufacture. P12 Battery Chargers, P12 Remote Displays, BatteryLink Chargers, Sure Eject AC Disconnects, M2 OLED Digital Meters and Mini OLED Digital Meters are warranted for a period of five years from the date of first purchase. \u003c\/p\u003e\n\u003cp\u003eAll other Digital Meters are warranted for a period of three years from the date of first purchase. No compensation will be allowed for products not returned to Blue Sea Systems for analysis, nor will compensation be made for labor required to replace any defective product. Please contact\u003cspan\u003e \u003c\/span\u003e\u003ca href=\"mailto:conductor@bluesea.com\"\u003eCustomer Service\u003c\/a\u003e\u003cspan\u003e \u003cmeta charset=\"utf-8\"\u003e\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003efor an RMA number prior to shipping any product back to Blue Sea Systems.\u003c\/p\u003e\n\u003cdiv id=\"footer_container\"\u003e\n\u003cdiv id=\"footer\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003eProduct FAQs\u003c\/h3\u003e\n\u003cp\u003eN\/A\u003c\/p\u003e","brand":"Blue Sea Systems","offers":[{"title":"Default Title","offer_id":51023332081947,"sku":"OGL-34967","price":277.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0724\/2026\/2171\/files\/34967XL.jpg?v=1757454103","url":"https:\/\/www.offgridlivingsolutions.com\/products\/blue-sea-7622-ml-series-heavy-duty-automatic-charging-relay-7622","provider":"OffGrid Living","version":"1.0","type":"link"}