{"title":"DC to DC Converters","description":"","products":[{"product_id":"samlex-12a-non-isolated-step-down-24vdc-12vdc-converter-heavy-duty-applications-sdc-15","title":"Samlex 12A Non-Isolated Step-Down 24VDC-12VDC Converter - Heavy Duty Applications [SDC-15]","description":"\u003ch2\u003e\u003cspan style=\"text-decoration: underline;\"\u003eSamlex 12A Non-Isolated Step-Down 24VDC-12VDC Converter - Heavy Duty Applications [SDC-15]\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003eThis high efficiency switch-mode step-down DC-DC converter converts an input voltage of 24 VDC nominal (range 20 VDC to 35 VDC) to a highly regulated output voltage of 12 VDC nominal (13.8 VDC) at 12 Amps. The SDC-15 DC-DC converter is non-isolated (no galvanic isolation between input and output) and meant for use in negative ground systems. Features include overvoltage\/short-circuit protection, temperature compensated current limit, output-side overvoltage protection, input-side overvoltage\/ transient protection and input-side reverse polarity protection. The SDC-15 DC-DC converter is designed for heavy duty applications.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eAdvanced switchmode design\u003c\/li\u003e\n\u003cli\u003eMount in almost any location\u003c\/li\u003e\n\u003cli\u003eCompact and light weight\u003c\/li\u003e\n\u003cli\u003eReverse polarity protection\u003c\/li\u003e\n\u003cli\u003eHigh efficiency\u003c\/li\u003e\n\u003cli\u003eCycle by cycle current limiting circuit\u003c\/li\u003e\n\u003cli\u003eOvervoltage protection\u003c\/li\u003e\n\u003cli\u003eShort circuit protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eProduct Specifications\u003c\/h3\u003e\n\u003ch2\u003e\u003cspan style=\"text-decoration: underline;\"\u003eSamlex 12A Non-Isolated Step-Down 24VDC-12VDC Converter - Heavy Duty Applications [SDC-15] Product Specifications\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eInput: 20-35 VDC\u003c\/li\u003e\n\u003cli\u003eOutput: 13.8 VDC\u003c\/li\u003e\n\u003cli\u003eAmps: 12 Amps\u003c\/li\u003e\n\u003cli\u003eWeight: 2 (lbs)\u003c\/li\u003e\n\u003cli\u003eWeight: 0.9 (kg)\u003c\/li\u003e\n\u003cli\u003eDimensions: 7.75 x 5 x 2.5 (in)\u003c\/li\u003e\n\u003cli\u003eDimensions: 19.7 x 12.7 x 6.4 (cm)\u003c\/li\u003e\n\u003cli\u003eWarranty: 2 Year Limited\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eEarth moving equipment\u003c\/li\u003e\n\u003cli\u003eHeavy trucks\u003c\/li\u003e\n\u003cli\u003eBuses\u003c\/li\u003e\n\u003cli\u003eMarine vehicles\u003c\/li\u003e\n\u003cli\u003eCB radios\u003c\/li\u003e\n\u003cli\u003e12 Volt lighting systems\u003c\/li\u003e\n\u003cli\u003eAM\/FM sound systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/productimageserver.com\/prop65\/6pt.png\" alt=\"Warning\"\u003e\u003cstrong\u003eWARNING:\u003c\/strong\u003e This product can expose you to chemicals which are known to the State of California to cause cancer, birth defects or other reproductive harm. For more information go to \u003ca href=\"http:\/\/P65Warnings.ca.gov\"\u003eP65Warnings.ca.gov\u003c\/a\u003e.\u003c\/p\u003e\n\u003c!--- cis2:m2lsnZdp ---\u003e\n\u003ch3\u003e\u003cspan\u003eProduct Manual\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/productimageserver.com\/literature\/ownersManual\/67245OM.pdf\" target=\"_blank\"\u003eOwner's Manual (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/productimageserver.com\/literature\/brochure\/67245BR.pdf\" target=\"_blank\"\u003eBrochure (pdf)\u003c\/a\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eProduct Warranty\u003c\/span\u003e\u003c\/h3\u003e\n\u003ch2 class=\"o-product--description\"\u003e3 Years Limited Warranty\u003c\/h2\u003e\n\u003ch3 class=\"o-product--description\"\u003eProduct FAQs\u003c\/h3\u003e\n\u003ch5 class=\"o-product--description\"\u003eWhat is a Pure Sine Wave Inverter?\u003c\/h5\u003e\n\u003cdiv class=\"o-product--description\"\u003eThe output voltage of a sine wave inverter has a sine wave form like the sine wave form of the mains \/ utility voltage. In a sine wave, the voltage rises and falls smoothly with a smoothly changing phase angle and also changes its polarity instantly when it crosses 0 Volts.\n\u003cdiv class=\"r-faqs--faq-answer j-faqs--answer open\"\u003e\n\u003cdiv class=\"r-faqs--faq j-faqs--single\" id=\"What-are-the-advantages-of-Pure-Sine-Wave-inverters\"\u003e\n\u003ch5 class=\"r-faqs--faq-question j-faqs--question\"\u003eWhat are the advantages of Pure Sine Wave inverters?\u003c\/h5\u003e\n\u003cdiv class=\"r-faqs--faq-answer j-faqs--answer open\"\u003e\n\u003cul\u003e\n\u003cli\u003eThe output wave-form is a sine-wave with\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003every low harmonic distortion\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand clean power like utility supplied electricity\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eInductive loads\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003elike microwaves and motors run faster, quieter and cooler\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eReduces audible and electrical noise\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ein fans, fluorescent lights, audio amplifiers, TV, fax and answering machines\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePrevents crashes\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ein computers, weird print outs and glitches in monitors\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cspan class=\"r-faqs--faq-toggle s-read-more j-faqs--toggle\"\u003e\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"r-faqs--faq j-faqs--single\"\u003e\n\u003cdiv class=\"r-faqs--faq j-faqs--single\" id=\"What-is-a-Modified-Sine-Wave-Inverter\"\u003e\n\u003ch5 class=\"r-faqs--faq-question j-faqs--question\"\u003eWhat is a Modified Sine Wave Inverter?\u003c\/h5\u003e\n\u003cdiv class=\"r-faqs--faq-answer j-faqs--answer open\"\u003e\n\u003cp\u003eIn a modified sine wave, the voltage rises and falls abruptly, the phase angle also changes abruptly and it sits at 0 Volts for some time before changing its polarity.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cspan class=\"r-faqs--faq-toggle s-read-more j-faqs--toggle\"\u003e\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"r-faqs--faq j-faqs--single\"\u003e\n\u003ch5 class=\"r-faqs--faq-question j-faqs--question\"\u003eWhat are the advantages of Pure Sine Wave inverters?\u003c\/h5\u003e\n\u003cdiv class=\"r-faqs--faq-answer j-faqs--answer open\"\u003e\n\u003cul\u003e\n\u003cli\u003eThe output wave-form is a sine-wave with\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003every low harmonic distortion\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand clean power like utility supplied electricity\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eInductive loads\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003elike microwaves and motors run faster, quieter and cooler\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eReduces audible and electrical noise\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ein fans, fluorescent lights, audio amplifiers, TV, fax and answering machines\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePrevents crashes\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ein computers, weird print outs and glitches in monitors\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"o-resource-body\"\u003e\n\u003cdiv class=\"r-faqs j-faqs\"\u003e\n\u003cdiv class=\"r-faqs--container\"\u003e\n\u003cdiv class=\"r-faqs--faqs j-faqs--faqs\"\u003e\n\u003cdiv class=\"r-faqs--faq j-faqs--single\" id=\"Which-devices-will-not-function-properly-from-a-Modified-Sine-Wave-Inverter\"\u003e\n\u003ch5 class=\"r-faqs--faq-question j-faqs--question\"\u003eWhich devices will not function properly from a Modified Sine Wave Inverter?\u003c\/h5\u003e\n\u003cdiv class=\"r-faqs--faq-answer j-faqs--answer open\"\u003e\n\u003cp\u003eAny device that uses a control circuitry that senses the phase (for voltage \/ speed control) or instantaneous zero voltage crossing (for timing control) will not work properly from a voltage that has a modified sine wave-form. Also, as the modified sine wave is a form of square wave, it is comprised of multiple sine waves of odd harmonics (multiples) of the fundamental frequency of the modified sine wave. For example, a 60 Hz. modified sine wave will consist of sine waves with odd harmonic frequencies of 3rd (180 Hz), 5th (300 Hz.), 7th (420 Hz.) and so on. The high frequency harmonic content in a modified sine wave produces enhanced radio interference, higher heating effect in motors \/ microwaves and produces overloading due to lowering of the impedance of low frequency filter capacitors \/ power factor improvement capacitors.\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eSome examples of devices that may not work properly with modified sine wave and may also get damaged are given below\u003c\/em\u003e\u003c\/p\u003e\n\u003cul type=\"circle\"\u003e\n\u003cli\u003eLaser printers, photocopiers, magneto-optical hard drives\u003c\/li\u003e\n\u003cli\u003eThe built-in clocks in devices such as clock radios, alarm clocks, coffee makers, bread-makers, VCR, microwave ovens etc may not keep time correctly\u003c\/li\u003e\n\u003cli\u003eOutput voltage control devices like dimmers, ceiling fan \/ motor speed control may not work properly (dimming \/ speed control may not function)\u003c\/li\u003e\n\u003cli\u003eSewing machines with speed \/ microprocessor control\u003c\/li\u003e\n\u003cli\u003eTransformer-less capacitive input powered devices like (i) Razors, flashlights, night-lights, smoke detectors etc (ii) Re-chargers for battery packs used in hand power tools.\u003cspan\u003e \u003c\/span\u003e\u003cem\u003eThese may get damaged. Please check with the manufacturer of these types of devices for suitability\u003c\/em\u003e\n\u003c\/li\u003e\n\u003cli\u003eDevices that use radio frequency signals carried by the AC distribution wiring\u003c\/li\u003e\n\u003cli\u003eSome new furnaces with microprocessor control \/ Oil burner primary controls\u003c\/li\u003e\n\u003cli\u003eHigh intensity discharge (HID) lamps like Metal Halide lamps.\u003cspan\u003e \u003c\/span\u003e\u003cem\u003eThese may get damaged. Please check with the manufacturer of these types of devices for suitability\u003c\/em\u003e\n\u003c\/li\u003e\n\u003cli\u003eSome fluorescent lamps \/ light fixtures that have power factor correction capacitors.\u003cspan\u003e \u003c\/span\u003e\u003cem\u003eThe inverter may shut down indicating overload\u003c\/em\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5 class=\"r-faqs--faq-question j-faqs--question\"\u003eWhat is a DC-AC inverter?\u003c\/h5\u003e\n\u003cp\u003eWhen you plug anything into the wall in your home you are usually “plugging in” to the power-grid provided as a service by your utility company. Your utility company supplies you with alternating current (AC) electricity. AC electricity flows in alternate directions many times per second. AC is used for utility grid service because it is more practical for long distance transmission.\u003c\/p\u003e\n\u003cp\u003eBatteries provide direct current electricity (DC) electricity which flows in a single direction.  DC power is what is used in many electronics in the home like laptops, solar cells, LED bulbs, and electric vehicles.  They usually have built-in converters to take the AC power received from a plug-in and convert it to DC.\u003c\/p\u003e\n\u003cp\u003eAn inverter (converter) acts as a power adapter as it converts DC to AC,  AC to DC, and can also change the voltage. It allows a battery-based system to run conventional AC appliances directly or through conventional home wiring.\u003c\/p\u003e\n\u003ch5 class=\"r-faqs--faq-question j-faqs--question\"\u003eWhat are the criteria for selecting the right inverter for a particular application?\u003c\/h5\u003e\n\u003cdiv id=\"What-are-the-criteria-for-selecting-the-right-inverter-for-a-particular-application\" class=\"r-faqs--faq j-faqs--single\"\u003e\n\u003cdiv class=\"r-faqs--faq-answer j-faqs--answer open\"\u003e\n\u003cp\u003eTo choose an inverter; you should first define your needs. Where is the inverter to be used? Inverters are available for use in buildings (including homes), for recreational vehicles, boats, and portable applications. Will it be connected to the utility grid in some way? Electrical conventions and safety standards differ for various applications, so don’t improvise.\u003c\/p\u003e\n\u003cp\u003eWhen sizing an inverter, you need to take into consideration both the\u003cstrong\u003e\u003cem\u003e\u003cspan\u003e \u003c\/span\u003erunning power\u003c\/em\u003e\u003c\/strong\u003e \u003cspan\u003e \u003c\/span\u003e\u003cem\u003e\u003cstrong\u003e(continuous)\u003c\/strong\u003e\u003c\/em\u003e\u003cspan\u003e \u003c\/span\u003eand the additional\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e\u003cem\u003estarting surge power\u003c\/em\u003e\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003erequirements of the AC side loads.\u003c\/p\u003e\n\u003cp\u003eSome loads require much higher starting surge power for the first few seconds before settling down at the running power. The inverter should be sized on the basis of the starting surge power of the AC side load. The total starting surge power is equal to the normal running power plus the additional starting power. The following symbols and equation will be used for explanation purposes:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eRunning Power, Watts – \u003cstrong\u003eWr\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eAdditional Starting Power or Additional Continuous Power, Watts – \u003cstrong\u003eWa\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eTotal Starting Surge Power, Watts = Running Power (\u003cstrong\u003eWr\u003c\/strong\u003e) + Additional Starting Power \/ Additional Continuous Power (\u003cstrong\u003eWa\u003c\/strong\u003e)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe specifications of inverters may include a rating termed Surge Power. Normally, the duration of this Surge Power rating is not quantified in the specifications and is assumed to last for less than 1 second. Unless the Surge Power Rating of the inverter is specified to last for \u0026gt; 5 seconds, this Surge Power specification of the inverter should not be considered for purposes of sizing loads with high and prolonged starting surge power.\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eOnly the Continuous Power rating of the inverter should be considered in such cases\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eElectric motor driven compressor\/pump based loads like refrigerators\/freezers, air conditioners, air compressors, sump and well pumps, etc. require a very high Starting Surge Power of around 5 to 7 times the Running Power for the initial start up. This Starting Surge Power may last for 2 to 5 seconds.  The Additional Starting Power\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eWa\u003c\/strong\u003e should be taken as 4 times the Running Power \u003cstrong\u003eWr\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eSwitched Mode Power Supplies (SMPS) that do not have Power Factor correction draw a non linear, pulsing current with a high Crest Factor (Ratio of instantaneous value and the RMS value) that may reach a value of 4. Also, the effective Power Factor of these types of power supplies is very low around 0.6. If the inverter is sized based on the Running Power of these units, the inverter will be continuously overloaded from instant to instant due to the higher peaks of the pulsing current. The inverter for these units should be sized at 3 times the Running Power of the power supply. Alternatively, for sizing purposes, the Additional Continuous Power \u003cstrong\u003eWa\u003c\/strong\u003e should be taken as 2 times the Running Power \u003cstrong\u003eWr\u003c\/strong\u003e. Consumer electronics like computers, TV, VCR, audio\/ video devices, etc. use this type of power supply.\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e(Please note that this sizing is not applicable if the SMPS has Power Factor correction and the Power Factor is around 0.9)\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eMotors used in washing machines have to start under load due to the weight of the clothes, water and the drum. Hence, the Additional Starting Power \u003cstrong\u003eWa\u003c\/strong\u003e should be taken as 2 times the Running Power \u003cstrong\u003eWr\u003c\/strong\u003e. This starting power normally lasts from 2 to 5 seconds.\u003c\/p\u003e\n\u003cp\u003eThe Watt rating of the microwaves normally indicates output cooking power in Watts. As the microwave is not an efficient device, the AC input power in Watts should be taken as 2 times the output cooking power in Watts i.e. the Additional Continuous Power \u003cstrong\u003eWa\u003c\/strong\u003e should be taken as 1 time the Running Power \u003cstrong\u003eWr\u003c\/strong\u003e. Hence, a microwave with 900 Watt cooking power will require an 1800 Watt inverter. \u003cstrong\u003e(If the power rating of the inverter is indicated as the AC input power in Watts, the factor of 2 is not applicable).\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe following symbols and equations are used in the sizing of an inverter example below:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTotal Running Power of the items selected, Watts – \u003cstrong\u003eWrt\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eHighest Additional Starting Power out of the items selected, Watts – \u003cstrong\u003eWah\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e*Highest power for sizing purpose, Watts – \u003cstrong\u003eWrt + Wah\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003e* It is assumed that only one out of the selected items starts at one time\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003eSince the AC loads rarely start at the same time, the load with the highest Additional Starting Power \u003cstrong\u003eWah\u003c\/strong\u003e has been factored in.\u003c\/p\u003e\n\u003cp\u003eExample:\u003cbr\u003e\u003c\/p\u003e\n\u003ctable class=\"tablepress tablepress-id-15 tablepress-responsive\" id=\"tablepress-15\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"row-1 odd\"\u003e\n\u003cth class=\"column-1\"\u003e\n\u003cp\u003e\u003csmall\u003eDevice \/ Appliance\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/th\u003e\n\u003cth class=\"column-2\"\u003e\n\u003cp\u003e\u003csmall\u003eRunning Power, Wr, Watts\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/th\u003e\n\u003cth class=\"column-3\"\u003e\n\u003cp\u003e\u003csmall\u003eAdditional\u003cbr\u003eStarting Power or Additional Continuous Power *, Wa, Watts\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/th\u003e\n\u003cth class=\"column-4\"\u003e\n\u003cp\u003e\u003csmall\u003eQuantity\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/th\u003e\n\u003cth class=\"column-5\"\u003e\n\u003cp\u003e\u003csmall\u003eExtended\u003cbr\u003eRunning Power, Wt, Watts\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody class=\"row-hover\"\u003e\n\u003ctr class=\"row-2 even\"\u003e\n\u003ctd class=\"column-1\"\u003e\n\u003cp\u003e\u003csmall\u003eRefrigerator – Electric Compressor based\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"column-2\"\u003e\n\u003cp\u003e\u003csmall\u003e200\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"column-3\"\u003e\n\u003cp\u003e\u003csmall\u003e800\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"column-4\"\u003e\n\u003cp\u003e\u003csmall\u003e1\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"column-5\"\u003e\n\u003cp\u003e\u003csmall\u003e200\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"row-3 odd\"\u003e\n\u003ctd class=\"column-1\"\u003e\n\u003cp\u003e\u003csmall\u003eColor TV\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"column-2\"\u003e\n\u003cp\u003e\u003csmall\u003e225\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"column-3\"\u003e\n\u003cp\u003e\u003csmall\u003e450\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"column-4\"\u003e\n\u003cp\u003e\u003csmall\u003e1\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"column-5\"\u003e\n\u003cp\u003e\u003csmall\u003e225\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"row-4 even\"\u003e\n\u003ctd class=\"column-1\"\u003e\n\u003cp\u003e\u003csmall\u003eLaptop Adapter\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"column-2\"\u003e\n\u003cp\u003e\u003csmall\u003e120\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"column-3\"\u003e\n\u003cp\u003e\u003csmall\u003e240\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"column-4\"\u003e\n\u003cp\u003e\u003csmall\u003e1\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"column-5\"\u003e\n\u003cp\u003e\u003csmall\u003e120\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"row-5 odd\"\u003e\n\u003ctd class=\"column-1\"\u003e\n\u003cp\u003e\u003csmall\u003eIncandescent Lamps\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"column-2\"\u003e\n\u003cp\u003e\u003csmall\u003e60\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"column-3\"\u003e\n\u003cp\u003e\u003csmall\u003e0\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"column-4\"\u003e\n\u003cp\u003e\u003csmall\u003e6\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"column-5\"\u003e\n\u003cp\u003e\u003csmall\u003e360\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e*\u003c\/strong\u003e \u003cem\u003eAdditional Continuous Power is applicable to SMPS based loads that have no Power Factor Correction.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003eTotal Extended Running Power, \u003cstrong\u003eWrt\u003c\/strong\u003e = 200 + 225 + 120 + 360 = \u003cstrong\u003e905\u003c\/strong\u003e Watts\u003c\/p\u003e\n\u003cp\u003eHighest Additional Starting Power, \u003cstrong\u003eWah\u003c\/strong\u003e = \u003cstrong\u003e800\u003c\/strong\u003e Watts\u003c\/p\u003e\n\u003cp\u003eHighest Power for sizing the inverter = Total Running Power, \u003cstrong\u003eWrt\u003c\/strong\u003e(905 W) + Highest Additional Starting Power, \u003cstrong\u003eWah\u003c\/strong\u003e (800 W) = \u003cstrong\u003e1705\u003c\/strong\u003e Watts\u003c\/p\u003e\n\u003ch5 class=\"r-faqs--faq-question j-faqs--question\"\u003eWhat are the electrical standards pertaining to DC-AC inverters?\u003c\/h5\u003e\n\u003cdiv class=\"r-faqs--faq-answer j-faqs--answer open\"\u003e\n\u003cmeta charset=\"utf-8\"\u003e\n\u003cp\u003eThe DC input voltage must conform to that of the electrical system and battery bank. 12 volts is recommended for small, simple systems. 24 and 48 volts are the common standards for higher capacities. A higher voltage system carries less current, which makes the system wiring cheaper and easier.\u003c\/p\u003e\n\u003cp\u003eThe inverter’s AC output must conform to the conventional power in the region to run locally available appliances. The standard for AC utility service in North America is 120 and 240 Volts at a frequency of 60 Hertz (cycles per second). In Europe, South America, and most other places, it is 230 volts at 50 Hertz.\u003c\/p\u003e\n\u003ch5 class=\"r-faqs--faq-question j-faqs--question\"\u003eWhat are \"continuous\" and \"surge\" power capacity ratings for DC-AC inverters?\u003c\/h5\u003e\n\u003cdiv id=\"What-are-continuous-and-surge-power-capacity-ratings-for-DC-AC-inverters\" class=\"r-faqs--faq j-faqs--single\"\u003e\n\u003cdiv class=\"r-faqs--faq-answer j-faqs--answer open\"\u003e\n\u003cp\u003eHow much load can an inverter handle? Its power output is rated in Watts.  There are two levels of power rating -a continuous rating and a surge rating. Continuous means the amount of power the inverter can handle for an indefinite period of hours. When an inverter is rated at a certain number of Watts, that number generally refers to its continuous rating. The “surge power” indicates the power to handle instantaneous overload of a few seconds to provide the higher power required to start certain type of devices and appliances.  Resistive types of loads (like incandescent lamps, toaster, coffee maker, electric range, iron etc) do not require extra power to start. Their starting power is the same as their running power.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cspan class=\"r-faqs--faq-toggle s-read-more j-faqs--toggle\"\u003e\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"r-faqs--faq j-faqs--single\"\u003e\n\u003ch5 class=\"r-faqs--faq-question j-faqs--question\"\u003eHow do \"surge power\" electrical loads affect DC-AC inverter operation?\u003c\/h5\u003e\n\u003cp\u003eIf an inverter cannot efficiently feed the surge power, it may simply shut down instead of starting the device. If the inverter’s surge capacity is marginal, its output voltage will dip during the surge. This can cause a dimming of the lights in the house, and will sometimes crash a computer.\u003c\/p\u003e\n\u003cp\u003eAny weakness in the battery and cabling to the inverter will further limit its ability to start a motor. A battery bank that is undersized, in poor condition, or has corroded connections, can be a weak link in the power chain. The inverter cables and the battery interconnect cables must be sized properly. The spike of DC current through these cables is many hundreds of amps at the instant of a motor starting for example.\u003c\/p\u003e\n\u003ch5 class=\"r-faqs--faq-question j-faqs--question\"\u003eHow should I size my DC-AC inverter for loads that require starting surge?\u003c\/h5\u003e\n\u003cdiv id=\"How-should-I-size-my-DC-AC-inverter-for-loads-that-require-starting-surge\" class=\"r-faqs--faq j-faqs--single\"\u003e\n\u003cdiv class=\"r-faqs--faq-answer j-faqs--answer open\"\u003e\n\u003cp\u003eObserve the following guideline to determine the continuous wattage of the inverter for powering loads that require starting surge. (Multiply the running watts of the device\/appliance by the Surge Factor)\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003e\u003cstrong\u003eNOTE:\u003c\/strong\u003e The surge power rating specified for this inverter is valid for duration of less than 1 second. This very short duration may not be sufficient to start motor based loads which may require up to 5 seconds to complete starting process. Hence, for purposes of sizing the inverter, use only the continuous power rating of this inverter.\u003c\/em\u003e\u003c\/p\u003e\n\u003ctable class=\"tablepress tablepress-id-16 tablepress-responsive\" id=\"tablepress-16\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"row-1 odd\"\u003e\n\u003cth class=\"column-1\"\u003e\n\u003cp\u003e\u003csmall\u003eDevice \/ Appliance\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/th\u003e\n\u003cth class=\"column-2\"\u003e\n\u003cp\u003e\u003csmall\u003eSurge Factor\u003cbr\u003e(No. of times the running power rating of the device\/appliance)\u003c\/small\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody class=\"row-hover\"\u003e\n\u003ctr class=\"row-2 even\"\u003e\n\u003ctd class=\"column-1\"\u003e\n\u003cp\u003e\u003csmall\u003eRefrigerator \/ Freezer\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"column-2\"\u003e\n\u003cp\u003e\u003csmall\u003e5\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"row-3 odd\"\u003e\n\u003ctd class=\"column-1\"\u003e\n\u003cp\u003e\u003csmall\u003eAir Compressors\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"column-2\"\u003e\n\u003cp\u003e\u003csmall\u003e4\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"row-4 even\"\u003e\n\u003ctd class=\"column-1\"\u003e\n\u003cp\u003e\u003csmall\u003eDishwasher\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"column-2\"\u003e\n\u003cp\u003e\u003csmall\u003e3\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"row-5 odd\"\u003e\n\u003ctd class=\"column-1\"\u003e\n\u003cp\u003e\u003csmall\u003eSump pump\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"column-2\"\u003e\n\u003cp\u003e\u003csmall\u003e3\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"row-6 even\"\u003e\n\u003ctd class=\"column-1\"\u003e\n\u003cp\u003e\u003csmall\u003eFurnace fans\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"column-2\"\u003e\n\u003cp\u003e\u003csmall\u003e3\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"row-7 odd\"\u003e\n\u003ctd class=\"column-1\"\u003e\n\u003cp\u003e\u003csmall\u003eIndustrial motors\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"column-2\"\u003e\n\u003cp\u003e\u003csmall\u003e3\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"row-8 even\"\u003e\n\u003ctd class=\"column-1\"\u003e\n\u003cp\u003e\u003csmall\u003eCircular saw\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"column-2\"\u003e\n\u003cp\u003e\u003csmall\u003e3\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"row-9 odd\"\u003e\n\u003ctd class=\"column-1\"\u003e\n\u003cp\u003e\u003csmall\u003eBench Grinder\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"column-2\"\u003e\n\u003cp\u003e\u003csmall\u003e3\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"row-10 even\"\u003e\n\u003ctd class=\"column-1\"\u003e\n\u003cp\u003e\u003csmall\u003ePortable diesel \/ kerosene fuel heater\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"column-2\"\u003e\n\u003cp\u003e\u003csmall\u003e2\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cspan class=\"r-faqs--faq-toggle s-read-more j-faqs--toggle\"\u003e\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"r-faqs--faq j-faqs--single\"\u003e\n\u003cdiv id=\"How-should-I-size-my-DC-AC-inverter-to-operate-a-microwave\" class=\"r-faqs--faq j-faqs--single\"\u003e\n\u003ch5 class=\"r-faqs--faq-question j-faqs--question\"\u003eHow should I size my DC-AC inverter to operate a microwave?\u003c\/h5\u003e\n\u003cspan class=\"r-faqs--faq-toggle s-read-more j-faqs--toggle\"\u003e\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"r-faqs--faq j-faqs--single\"\u003e\n\u003cdiv id=\"How-should-I-size-my-DC-AC-inverter-to-operate-a-microwave\" class=\"r-faqs--faq j-faqs--single\"\u003e\n\u003cdiv class=\"r-faqs--faq-answer j-faqs--answer open\"\u003e\n\u003cp\u003eThe power rating of the microwave generally refers to the cooking power. The electrical power consumed by the microwave will be approximately 2 times the cooking power. The “surge power” of the inverter should be 2 times the electrical power (i.e., 4 times the cooking power). Please note that the surge power of the microwave is not as long as the motor load and hence, the surge power of the inverter can be considered to determine adequacy of meeting the starting surge power.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cspan class=\"r-faqs--faq-toggle s-read-more j-faqs--toggle\"\u003e\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"r-faqs--faq j-faqs--single\"\u003e\n\u003ch5 class=\"r-faqs--faq-question j-faqs--question\"\u003eHow should I size my DC-AC inverter to power a water supply pump?\u003c\/h5\u003e\n\u003cp\u003eA water well or pressure pump often places the greatest demand on the inverter. It warrants special consideration. Most pumps draw a very high surge of current during start up. The inverter must have sufficient surge capacity to handle it while running any other loads that may be on. It is important to size an inverter sufficiently, especially to handle the starting surge (If the exact starting rating is not available, the starting surge can be taken as 3 times the normal running rating of the pump). Oversize it still further if you want it to start the pump without causing lights to dim or blink.\u003c\/p\u003e\n\u003cp\u003eIn North America, most pumps (especially submersibles) run on 240 VAC, while smaller appliances and lights use 120 VAC. To obtain 240 VAC from a 120 VAC inverter, use a 120 VAC to 240 VAC transformer. If you do not already have a pump installed, you can get a 120 volt pump if you don’t need more than 1\/2 HP.\u003c\/p\u003e\n\u003ch5 class=\"r-faqs--faq-question j-faqs--question\"\u003eWhat is \"idle power\" in a DC-AC inverter?\u003c\/h5\u003e\n\u003cdiv id=\"What-is-idle-power-in-a-DC-AC-inverter\" class=\"r-faqs--faq j-faqs--single\"\u003e\n\u003cdiv class=\"r-faqs--faq-answer j-faqs--answer open\"\u003e\n\u003cp\u003eIdle power is the consumption of the inverter when it is on, but no loads are running. It is “wasted” power, so if you expect the inverter to be on for many hours during which there is very little load (as in most residential situations), you want this to be as low as possible.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cspan class=\"r-faqs--faq-toggle s-read-more j-faqs--toggle\"\u003e\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"r-faqs--faq j-faqs--single\"\u003e\n\u003ch5 class=\"r-faqs--faq-question j-faqs--question\"\u003eWhat are Phantom and idling loads?\u003c\/h5\u003e\n\u003cp\u003eMost of the modern gadgets draw some power whenever they are plugged in. Some of them use power to do nothing at all. An example is a TV with a remote control. Its electric eye system is on day and night, watching for your signal to turn the screen on. Every appliance with an external wall-plug transformer uses power even when the appliance is turned off. These little loads are called “phantom loads” because their power draw is unexpected, unseen, and easily forgotten.\u003c\/p\u003e\n\u003cp\u003eA similar concern is “idling loads.” These are devices that must be on all the time in order to function when needed. These include smoke detectors, alarm systems, motion detector lights, fax machines, and answering machines. Central heating systems have a transformer in their thermostat circuit that stays on all the time. Cordless (rechargeable) appliances draw power even after their batteries reach a full charge. If in doubt, feel the device. If it’s warm, that indicates wasted energy.\u003c\/p\u003e\n\u003ch5 class=\"r-faqs--faq-question j-faqs--question\"\u003eCan a standard DC-AC inverter be connected in parallel with another AC source\/ DC-AC inverter \/ electrical utility?\u003c\/h5\u003e\n\u003cdiv id=\"Can-a-standard-DC-AC-inverter-be-connected-in-parallel-with-another-AC-source-DC-AC-inverter-electrical-utility\" class=\"r-faqs--faq j-faqs--single\"\u003e\n\u003cdiv class=\"r-faqs--faq-answer j-faqs--answer open\"\u003e\n\u003cp\u003eThe AC output of standard inverters cannot be synchronised with another AC source and hence, it is not suitable for paralleling. The AC output of the inverter should never be connected directly to an electrical breaker panel \/ load center which is also fed from the utility power \/generator. Such a connection may result in parallel operation of the different power sources and AC power from the utility \/ generator will be fed back into the inverter which will instantly damage the output section of the inverter and may also pose a fire and safety hazard.\u003c\/p\u003e\n\u003cp\u003eIf an electrical breaker panel \/ load center is fed from an inverter and this panel is also required to be powered from additional alternate AC sources, the AC power from all the AC sources like the utility \/ generator \/ inverter should first be fed to a manual selector switch and the output of the selector switch should be connected to the electrical breaker panel \/ load center. To prevent possibility of paralleling and severe damage to the inverter, never use a simple jumper cable with a male plug on both ends to connect the AC output of the inverter to a handy wall receptacle in the home\/RV.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cspan class=\"r-faqs--faq-toggle s-read-more j-faqs--toggle\"\u003e\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"r-faqs--faq j-faqs--single\"\u003e\n\u003ch5 class=\"r-faqs--faq-question j-faqs--question\"\u003eHow can DC-AC inverters be connected to multi-wire branch circuits?\u003c\/h5\u003e\n\u003cdiv id=\"How-can-DC-AC-inverters-be-connected-to-multi-wire-branch-circuits\" class=\"r-faqs--faq j-faqs--single\"\u003e\n\u003cdiv class=\"r-faqs--faq-answer j-faqs--answer open\"\u003e\n\u003cp\u003eDo not directly connect the hot side of the inverter to the two hot legs of the 120 \/ 240 VAC electrical breaker panel \/ load centre where multi-wire ( common neutral ) branch circuit wiring method is used for distribution of AC power. This may lead to overloading\/overheating of the neutral conductor and is a risk of fire.\u003c\/p\u003e\n\u003cp\u003eA split phase transformer (isolated or auto-transformer ) of suitable wattage rating ( 25% more than the wattage rating of the inverter ) with primary of 120 VAC and secondary of 120 \/ 240 VAC ( Two 120 VAC split phases 180 degrees apart) should be used. The hot and neutral of the 120 VAC output of the inverter should be fed to the primary of this transformer and the 2 hot outputs (120 VAC split phases ) and the neutral from the secondary of this transformer should be connected to the electrical breaker panel\/ load centre.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cspan class=\"r-faqs--faq-toggle s-read-more j-faqs--toggle\"\u003e\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv id=\"How-should-I-size-my-DC-AC-inverter-to-supply-computer-or-printer-loads\" class=\"r-faqs--faq j-faqs--single\"\u003e\n\u003ch5 class=\"r-faqs--faq-question j-faqs--question\"\u003eHow should I size my DC-AC inverter to supply computer or printer loads?\u003c\/h5\u003e\n\u003cdiv id=\"How-should-I-size-my-DC-AC-inverter-to-supply-computer-or-printer-loads\" class=\"r-faqs--faq j-faqs--single\"\u003e\n\u003cdiv class=\"r-faqs--faq-answer j-faqs--answer open\"\u003e\n\u003cp\u003eComputers and Printers generally come with in-built switch-mode power supplies (see \u003ca href=\"https:\/\/samlexamerica.com\/resources-support\/application-notes\/\"\u003eapplication notes\u003c\/a\u003e and \u003ca href=\"https:\/\/samlexamerica.com\/resources-support\/faq\/inverters-powering-direct-embedded-smps\/\"\u003eFAQs on switch mode power supplies (SMPS)\u003c\/a\u003e) that have extremely low power factor on account of the extremely peaky and non-linear nature of the current drawn by them from the AC source. Hence for such loads we recommend using inverters with three times the advertised power consumption of the computer or printer loads.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cspan class=\"r-faqs--faq-toggle s-read-more j-faqs--toggle\"\u003e\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"r-faqs--faq j-faqs--single\"\u003e\n\u003ch5 class=\"r-faqs--faq-question j-faqs--question\"\u003eWhat is the difference between a 12V, 24V and 48V inverter?\u003c\/h5\u003e\n\u003cdiv class=\"o-resource-body\"\u003e\n\u003cdiv class=\"r-faqs j-faqs\"\u003e\n\u003cdiv class=\"r-faqs--container\"\u003e\n\u003cdiv class=\"r-faqs--faqs j-faqs--faqs\"\u003e\n\u003cdiv id=\"What-is-the-difference-between-a-12V-24V-and-48V-inverter\" class=\"r-faqs--faq j-faqs--single\"\u003e\n\u003cdiv class=\"r-faqs--faq-answer j-faqs--answer open\"\u003e\n\u003cp\u003eA 12-V can be fed from a 12V battery or DC supply. Similarly 24V and 48V inverters can be fed from 24V and 48V batteries\/DC power supplies, respectively. Cars usually have 12V batteries. Trucks have 24V batteries.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Samlex America","offers":[{"title":"Default Title","offer_id":50359596220699,"sku":"OGL-67245","price":108.7,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0724\/2026\/2171\/files\/67245XL.jpg?v=1749567217"},{"product_id":"samlex-20a-non-isolated-step-down-24vdc-12vdc-converter-sdc-23","title":"Samlex 20A Non-Isolated Step-Down 24VDC-12VDC Converter [SDC-23]","description":"\u003ch2\u003e\u003cspan style=\"text-decoration: underline;\"\u003eSamlex 20A Non-Isolated Step-Down 24VDC-12VDC Converter [SDC-23]\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003eThis high efficiency switch-mode step-down DC-DC converter converts an input voltage of 24 VDC nominal (range 20 VDC to 35 VDC) to a highly regulated output voltage of 12 VDC nominal (13.8 VDC) at 20 Amps. The SDC-23 DC-DC converter is non-isolated (no galvanic isolation between input and output) and meant for use in negative ground systems. Features include overvoltage\/short-circuit protection, temperature compensated current limit, output-side overvoltage protection, input-side overvoltage\/ transient protection and input-side reverse polarity protection. The SDC-23 DC-DC converter is designed for heavy duty applications.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eAdvanced switchmode design\u003c\/li\u003e\n\u003cli\u003eMount in almost any location\u003c\/li\u003e\n\u003cli\u003eCompact and light weight\u003c\/li\u003e\n\u003cli\u003eReverse polarity protection\u003c\/li\u003e\n\u003cli\u003eHigh efficiency\u003c\/li\u003e\n\u003cli\u003eCurrent limiting circuit\u003c\/li\u003e\n\u003cli\u003eOvervoltage crowbar circuit\u003c\/li\u003e\n\u003cli\u003eNon-Isolated for negative ground system\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eProduct Specifications\u003c\/h3\u003e\n\u003ch2\u003e\u003cspan style=\"text-decoration: underline;\"\u003eSamlex 20A Non-Isolated Step-Down 24VDC-12VDC Converter [SDC-23] Product Specifications\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eInput: 20-30 VDC\u003c\/li\u003e\n\u003cli\u003eOutput: 13.8 VDC\u003c\/li\u003e\n\u003cli\u003eAmps: 20 Amps\u003c\/li\u003e\n\u003cli\u003eWeight: 2.2 (lbs)\u003c\/li\u003e\n\u003cli\u003eWeight: 1 (kg)\u003c\/li\u003e\n\u003cli\u003eDimensions: 7.75 x 4.75 x 2.4 (in)\u003c\/li\u003e\n\u003cli\u003eDimensions: 19.7 x 12.1 x 6.1 (cm)\u003c\/li\u003e\n\u003cli\u003eWarranty: 2 Year Limited\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eEarth moving equipment\u003c\/li\u003e\n\u003cli\u003eHeavy trucks\u003c\/li\u003e\n\u003cli\u003eBuses\u003c\/li\u003e\n\u003cli\u003eMarine vehicles\u003c\/li\u003e\n\u003cli\u003eCB radios\u003c\/li\u003e\n\u003cli\u003e12 Volt lighting systems\u003c\/li\u003e\n\u003cli\u003eAM\/FM sound systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/productimageserver.com\/prop65\/6pt.png\" alt=\"Warning\"\u003e\u003cstrong\u003eWARNING:\u003c\/strong\u003e This product can expose you to chemicals which are known to the State of California to cause cancer, birth defects or other reproductive harm. For more information go to \u003ca href=\"http:\/\/P65Warnings.ca.gov\"\u003eP65Warnings.ca.gov\u003c\/a\u003e.\u003c\/p\u003e\n\u003c!--- cis2:m2lsnZdp ---\u003e\n\u003ch3\u003e\u003cspan\u003eProduct Manual\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/productimageserver.com\/literature\/ownersManual\/67246OM.pdf\" target=\"_blank\"\u003eOwner's Manual (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/productimageserver.com\/literature\/brochure\/67246BR.pdf\" target=\"_blank\"\u003eBrochure (pdf)\u003c\/a\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eProduct Warranty\u003c\/span\u003e\u003c\/h3\u003e\n\u003ch2 class=\"o-product--description\"\u003e3 Years Limited Warranty\u003c\/h2\u003e\n\u003ch3 class=\"o-product--description\"\u003eProduct FAQs\u003c\/h3\u003e\n\u003ch5 class=\"o-product--description\"\u003eWhat is a Pure Sine Wave Inverter?\u003c\/h5\u003e\n\u003cdiv class=\"o-product--description\"\u003eThe output voltage of a sine wave inverter has a sine wave form like the sine wave form of the mains \/ utility voltage. In a sine wave, the voltage rises and falls smoothly with a smoothly changing phase angle and also changes its polarity instantly when it crosses 0 Volts.\n\u003cdiv class=\"r-faqs--faq-answer j-faqs--answer open\"\u003e\n\u003cdiv class=\"r-faqs--faq j-faqs--single\" id=\"What-are-the-advantages-of-Pure-Sine-Wave-inverters\"\u003e\n\u003ch5 class=\"r-faqs--faq-question j-faqs--question\"\u003eWhat are the advantages of Pure Sine Wave inverters?\u003c\/h5\u003e\n\u003cdiv class=\"r-faqs--faq-answer j-faqs--answer open\"\u003e\n\u003cul\u003e\n\u003cli\u003eThe output wave-form is a sine-wave with\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003every low harmonic distortion\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand clean power like utility supplied electricity\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eInductive loads\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003elike microwaves and motors run faster, quieter and cooler\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eReduces audible and electrical noise\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ein fans, fluorescent lights, audio amplifiers, TV, fax and answering machines\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePrevents crashes\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ein computers, weird print outs and glitches in monitors\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cspan class=\"r-faqs--faq-toggle s-read-more j-faqs--toggle\"\u003e\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"r-faqs--faq j-faqs--single\"\u003e\n\u003cdiv class=\"r-faqs--faq j-faqs--single\" id=\"What-is-a-Modified-Sine-Wave-Inverter\"\u003e\n\u003ch5 class=\"r-faqs--faq-question j-faqs--question\"\u003eWhat is a Modified Sine Wave Inverter?\u003c\/h5\u003e\n\u003cdiv class=\"r-faqs--faq-answer j-faqs--answer open\"\u003e\n\u003cp\u003eIn a modified sine wave, the voltage rises and falls abruptly, the phase angle also changes abruptly and it sits at 0 Volts for some time before changing its polarity.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cspan class=\"r-faqs--faq-toggle s-read-more j-faqs--toggle\"\u003e\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"r-faqs--faq j-faqs--single\"\u003e\n\u003ch5 class=\"r-faqs--faq-question j-faqs--question\"\u003eWhat are the advantages of Pure Sine Wave inverters?\u003c\/h5\u003e\n\u003cdiv class=\"r-faqs--faq-answer j-faqs--answer open\"\u003e\n\u003cul\u003e\n\u003cli\u003eThe output wave-form is a sine-wave with\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003every low harmonic distortion\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand clean power like utility supplied electricity\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eInductive loads\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003elike microwaves and motors run faster, quieter and cooler\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eReduces audible and electrical noise\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ein fans, fluorescent lights, audio amplifiers, TV, fax and answering machines\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePrevents crashes\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ein computers, weird print outs and glitches in monitors\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"o-resource-body\"\u003e\n\u003cdiv class=\"r-faqs j-faqs\"\u003e\n\u003cdiv class=\"r-faqs--container\"\u003e\n\u003cdiv class=\"r-faqs--faqs j-faqs--faqs\"\u003e\n\u003cdiv class=\"r-faqs--faq j-faqs--single\" id=\"Which-devices-will-not-function-properly-from-a-Modified-Sine-Wave-Inverter\"\u003e\n\u003ch5 class=\"r-faqs--faq-question j-faqs--question\"\u003eWhich devices will not function properly from a Modified Sine Wave Inverter?\u003c\/h5\u003e\n\u003cdiv class=\"r-faqs--faq-answer j-faqs--answer open\"\u003e\n\u003cp\u003eAny device that uses a control circuitry that senses the phase (for voltage \/ speed control) or instantaneous zero voltage crossing (for timing control) will not work properly from a voltage that has a modified sine wave-form. Also, as the modified sine wave is a form of square wave, it is comprised of multiple sine waves of odd harmonics (multiples) of the fundamental frequency of the modified sine wave. For example, a 60 Hz. modified sine wave will consist of sine waves with odd harmonic frequencies of 3rd (180 Hz), 5th (300 Hz.), 7th (420 Hz.) and so on. The high frequency harmonic content in a modified sine wave produces enhanced radio interference, higher heating effect in motors \/ microwaves and produces overloading due to lowering of the impedance of low frequency filter capacitors \/ power factor improvement capacitors.\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eSome examples of devices that may not work properly with modified sine wave and may also get damaged are given below\u003c\/em\u003e\u003c\/p\u003e\n\u003cul type=\"circle\"\u003e\n\u003cli\u003eLaser printers, photocopiers, magneto-optical hard drives\u003c\/li\u003e\n\u003cli\u003eThe built-in clocks in devices such as clock radios, alarm clocks, coffee makers, bread-makers, VCR, microwave ovens etc may not keep time correctly\u003c\/li\u003e\n\u003cli\u003eOutput voltage control devices like dimmers, ceiling fan \/ motor speed control may not work properly (dimming \/ speed control may not function)\u003c\/li\u003e\n\u003cli\u003eSewing machines with speed \/ microprocessor control\u003c\/li\u003e\n\u003cli\u003eTransformer-less capacitive input powered devices like (i) Razors, flashlights, night-lights, smoke detectors etc (ii) Re-chargers for battery packs used in hand power tools.\u003cspan\u003e \u003c\/span\u003e\u003cem\u003eThese may get damaged. Please check with the manufacturer of these types of devices for suitability\u003c\/em\u003e\n\u003c\/li\u003e\n\u003cli\u003eDevices that use radio frequency signals carried by the AC distribution wiring\u003c\/li\u003e\n\u003cli\u003eSome new furnaces with microprocessor control \/ Oil burner primary controls\u003c\/li\u003e\n\u003cli\u003eHigh intensity discharge (HID) lamps like Metal Halide lamps.\u003cspan\u003e \u003c\/span\u003e\u003cem\u003eThese may get damaged. Please check with the manufacturer of these types of devices for suitability\u003c\/em\u003e\n\u003c\/li\u003e\n\u003cli\u003eSome fluorescent lamps \/ light fixtures that have power factor correction capacitors.\u003cspan\u003e \u003c\/span\u003e\u003cem\u003eThe inverter may shut down indicating overload\u003c\/em\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5 class=\"r-faqs--faq-question j-faqs--question\"\u003eWhat is a DC-AC inverter?\u003c\/h5\u003e\n\u003cp\u003eWhen you plug anything into the wall in your home you are usually “plugging in” to the power-grid provided as a service by your utility company. Your utility company supplies you with alternating current (AC) electricity. AC electricity flows in alternate directions many times per second. AC is used for utility grid service because it is more practical for long distance transmission.\u003c\/p\u003e\n\u003cp\u003eBatteries provide direct current electricity (DC) electricity which flows in a single direction.  DC power is what is used in many electronics in the home like laptops, solar cells, LED bulbs, and electric vehicles.  They usually have built-in converters to take the AC power received from a plug-in and convert it to DC.\u003c\/p\u003e\n\u003cp\u003eAn inverter (converter) acts as a power adapter as it converts DC to AC,  AC to DC, and can also change the voltage. It allows a battery-based system to run conventional AC appliances directly or through conventional home wiring.\u003c\/p\u003e\n\u003ch5 class=\"r-faqs--faq-question j-faqs--question\"\u003eWhat are the criteria for selecting the right inverter for a particular application?\u003c\/h5\u003e\n\u003cdiv id=\"What-are-the-criteria-for-selecting-the-right-inverter-for-a-particular-application\" class=\"r-faqs--faq j-faqs--single\"\u003e\n\u003cdiv class=\"r-faqs--faq-answer j-faqs--answer open\"\u003e\n\u003cp\u003eTo choose an inverter; you should first define your needs. Where is the inverter to be used? Inverters are available for use in buildings (including homes), for recreational vehicles, boats, and portable applications. Will it be connected to the utility grid in some way? Electrical conventions and safety standards differ for various applications, so don’t improvise.\u003c\/p\u003e\n\u003cp\u003eWhen sizing an inverter, you need to take into consideration both the\u003cstrong\u003e\u003cem\u003e\u003cspan\u003e \u003c\/span\u003erunning power\u003c\/em\u003e\u003c\/strong\u003e \u003cspan\u003e \u003c\/span\u003e\u003cem\u003e\u003cstrong\u003e(continuous)\u003c\/strong\u003e\u003c\/em\u003e\u003cspan\u003e \u003c\/span\u003eand the additional\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e\u003cem\u003estarting surge power\u003c\/em\u003e\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003erequirements of the AC side loads.\u003c\/p\u003e\n\u003cp\u003eSome loads require much higher starting surge power for the first few seconds before settling down at the running power. The inverter should be sized on the basis of the starting surge power of the AC side load. The total starting surge power is equal to the normal running power plus the additional starting power. The following symbols and equation will be used for explanation purposes:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eRunning Power, Watts – \u003cstrong\u003eWr\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eAdditional Starting Power or Additional Continuous Power, Watts – \u003cstrong\u003eWa\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eTotal Starting Surge Power, Watts = Running Power (\u003cstrong\u003eWr\u003c\/strong\u003e) + Additional Starting Power \/ Additional Continuous Power (\u003cstrong\u003eWa\u003c\/strong\u003e)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe specifications of inverters may include a rating termed Surge Power. Normally, the duration of this Surge Power rating is not quantified in the specifications and is assumed to last for less than 1 second. Unless the Surge Power Rating of the inverter is specified to last for \u0026gt; 5 seconds, this Surge Power specification of the inverter should not be considered for purposes of sizing loads with high and prolonged starting surge power.\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eOnly the Continuous Power rating of the inverter should be considered in such cases\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eElectric motor driven compressor\/pump based loads like refrigerators\/freezers, air conditioners, air compressors, sump and well pumps, etc. require a very high Starting Surge Power of around 5 to 7 times the Running Power for the initial start up. This Starting Surge Power may last for 2 to 5 seconds.  The Additional Starting Power\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eWa\u003c\/strong\u003e should be taken as 4 times the Running Power \u003cstrong\u003eWr\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eSwitched Mode Power Supplies (SMPS) that do not have Power Factor correction draw a non linear, pulsing current with a high Crest Factor (Ratio of instantaneous value and the RMS value) that may reach a value of 4. Also, the effective Power Factor of these types of power supplies is very low around 0.6. If the inverter is sized based on the Running Power of these units, the inverter will be continuously overloaded from instant to instant due to the higher peaks of the pulsing current. The inverter for these units should be sized at 3 times the Running Power of the power supply. Alternatively, for sizing purposes, the Additional Continuous Power \u003cstrong\u003eWa\u003c\/strong\u003e should be taken as 2 times the Running Power \u003cstrong\u003eWr\u003c\/strong\u003e. Consumer electronics like computers, TV, VCR, audio\/ video devices, etc. use this type of power supply.\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e(Please note that this sizing is not applicable if the SMPS has Power Factor correction and the Power Factor is around 0.9)\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eMotors used in washing machines have to start under load due to the weight of the clothes, water and the drum. Hence, the Additional Starting Power \u003cstrong\u003eWa\u003c\/strong\u003e should be taken as 2 times the Running Power \u003cstrong\u003eWr\u003c\/strong\u003e. This starting power normally lasts from 2 to 5 seconds.\u003c\/p\u003e\n\u003cp\u003eThe Watt rating of the microwaves normally indicates output cooking power in Watts. As the microwave is not an efficient device, the AC input power in Watts should be taken as 2 times the output cooking power in Watts i.e. the Additional Continuous Power \u003cstrong\u003eWa\u003c\/strong\u003e should be taken as 1 time the Running Power \u003cstrong\u003eWr\u003c\/strong\u003e. Hence, a microwave with 900 Watt cooking power will require an 1800 Watt inverter. \u003cstrong\u003e(If the power rating of the inverter is indicated as the AC input power in Watts, the factor of 2 is not applicable).\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe following symbols and equations are used in the sizing of an inverter example below:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTotal Running Power of the items selected, Watts – \u003cstrong\u003eWrt\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eHighest Additional Starting Power out of the items selected, Watts – \u003cstrong\u003eWah\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e*Highest power for sizing purpose, Watts – \u003cstrong\u003eWrt + Wah\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003e* It is assumed that only one out of the selected items starts at one time\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003eSince the AC loads rarely start at the same time, the load with the highest Additional Starting Power \u003cstrong\u003eWah\u003c\/strong\u003e has been factored in.\u003c\/p\u003e\n\u003cp\u003eExample:\u003cbr\u003e\u003c\/p\u003e\n\u003ctable class=\"tablepress tablepress-id-15 tablepress-responsive\" id=\"tablepress-15\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"row-1 odd\"\u003e\n\u003cth class=\"column-1\"\u003e\n\u003cp\u003e\u003csmall\u003eDevice \/ Appliance\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/th\u003e\n\u003cth class=\"column-2\"\u003e\n\u003cp\u003e\u003csmall\u003eRunning Power, Wr, Watts\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/th\u003e\n\u003cth class=\"column-3\"\u003e\n\u003cp\u003e\u003csmall\u003eAdditional\u003cbr\u003eStarting Power or Additional Continuous Power *, Wa, Watts\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/th\u003e\n\u003cth class=\"column-4\"\u003e\n\u003cp\u003e\u003csmall\u003eQuantity\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/th\u003e\n\u003cth class=\"column-5\"\u003e\n\u003cp\u003e\u003csmall\u003eExtended\u003cbr\u003eRunning Power, Wt, Watts\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody class=\"row-hover\"\u003e\n\u003ctr class=\"row-2 even\"\u003e\n\u003ctd class=\"column-1\"\u003e\n\u003cp\u003e\u003csmall\u003eRefrigerator – Electric Compressor based\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"column-2\"\u003e\n\u003cp\u003e\u003csmall\u003e200\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"column-3\"\u003e\n\u003cp\u003e\u003csmall\u003e800\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"column-4\"\u003e\n\u003cp\u003e\u003csmall\u003e1\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"column-5\"\u003e\n\u003cp\u003e\u003csmall\u003e200\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"row-3 odd\"\u003e\n\u003ctd class=\"column-1\"\u003e\n\u003cp\u003e\u003csmall\u003eColor TV\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"column-2\"\u003e\n\u003cp\u003e\u003csmall\u003e225\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"column-3\"\u003e\n\u003cp\u003e\u003csmall\u003e450\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"column-4\"\u003e\n\u003cp\u003e\u003csmall\u003e1\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"column-5\"\u003e\n\u003cp\u003e\u003csmall\u003e225\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"row-4 even\"\u003e\n\u003ctd class=\"column-1\"\u003e\n\u003cp\u003e\u003csmall\u003eLaptop Adapter\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"column-2\"\u003e\n\u003cp\u003e\u003csmall\u003e120\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"column-3\"\u003e\n\u003cp\u003e\u003csmall\u003e240\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"column-4\"\u003e\n\u003cp\u003e\u003csmall\u003e1\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"column-5\"\u003e\n\u003cp\u003e\u003csmall\u003e120\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"row-5 odd\"\u003e\n\u003ctd class=\"column-1\"\u003e\n\u003cp\u003e\u003csmall\u003eIncandescent Lamps\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"column-2\"\u003e\n\u003cp\u003e\u003csmall\u003e60\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"column-3\"\u003e\n\u003cp\u003e\u003csmall\u003e0\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"column-4\"\u003e\n\u003cp\u003e\u003csmall\u003e6\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"column-5\"\u003e\n\u003cp\u003e\u003csmall\u003e360\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e*\u003c\/strong\u003e \u003cem\u003eAdditional Continuous Power is applicable to SMPS based loads that have no Power Factor Correction.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003eTotal Extended Running Power, \u003cstrong\u003eWrt\u003c\/strong\u003e = 200 + 225 + 120 + 360 = \u003cstrong\u003e905\u003c\/strong\u003e Watts\u003c\/p\u003e\n\u003cp\u003eHighest Additional Starting Power, \u003cstrong\u003eWah\u003c\/strong\u003e = \u003cstrong\u003e800\u003c\/strong\u003e Watts\u003c\/p\u003e\n\u003cp\u003eHighest Power for sizing the inverter = Total Running Power, \u003cstrong\u003eWrt\u003c\/strong\u003e(905 W) + Highest Additional Starting Power, \u003cstrong\u003eWah\u003c\/strong\u003e (800 W) = \u003cstrong\u003e1705\u003c\/strong\u003e Watts\u003c\/p\u003e\n\u003ch5 class=\"r-faqs--faq-question j-faqs--question\"\u003eWhat are the electrical standards pertaining to DC-AC inverters?\u003c\/h5\u003e\n\u003cdiv class=\"r-faqs--faq-answer j-faqs--answer open\"\u003e\n\u003cmeta charset=\"utf-8\"\u003e\n\u003cp\u003eThe DC input voltage must conform to that of the electrical system and battery bank. 12 volts is recommended for small, simple systems. 24 and 48 volts are the common standards for higher capacities. A higher voltage system carries less current, which makes the system wiring cheaper and easier.\u003c\/p\u003e\n\u003cp\u003eThe inverter’s AC output must conform to the conventional power in the region to run locally available appliances. The standard for AC utility service in North America is 120 and 240 Volts at a frequency of 60 Hertz (cycles per second). In Europe, South America, and most other places, it is 230 volts at 50 Hertz.\u003c\/p\u003e\n\u003ch5 class=\"r-faqs--faq-question j-faqs--question\"\u003eWhat are \"continuous\" and \"surge\" power capacity ratings for DC-AC inverters?\u003c\/h5\u003e\n\u003cdiv id=\"What-are-continuous-and-surge-power-capacity-ratings-for-DC-AC-inverters\" class=\"r-faqs--faq j-faqs--single\"\u003e\n\u003cdiv class=\"r-faqs--faq-answer j-faqs--answer open\"\u003e\n\u003cp\u003eHow much load can an inverter handle? Its power output is rated in Watts.  There are two levels of power rating -a continuous rating and a surge rating. Continuous means the amount of power the inverter can handle for an indefinite period of hours. When an inverter is rated at a certain number of Watts, that number generally refers to its continuous rating. The “surge power” indicates the power to handle instantaneous overload of a few seconds to provide the higher power required to start certain type of devices and appliances.  Resistive types of loads (like incandescent lamps, toaster, coffee maker, electric range, iron etc) do not require extra power to start. Their starting power is the same as their running power.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cspan class=\"r-faqs--faq-toggle s-read-more j-faqs--toggle\"\u003e\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"r-faqs--faq j-faqs--single\"\u003e\n\u003ch5 class=\"r-faqs--faq-question j-faqs--question\"\u003eHow do \"surge power\" electrical loads affect DC-AC inverter operation?\u003c\/h5\u003e\n\u003cp\u003eIf an inverter cannot efficiently feed the surge power, it may simply shut down instead of starting the device. If the inverter’s surge capacity is marginal, its output voltage will dip during the surge. This can cause a dimming of the lights in the house, and will sometimes crash a computer.\u003c\/p\u003e\n\u003cp\u003eAny weakness in the battery and cabling to the inverter will further limit its ability to start a motor. A battery bank that is undersized, in poor condition, or has corroded connections, can be a weak link in the power chain. The inverter cables and the battery interconnect cables must be sized properly. The spike of DC current through these cables is many hundreds of amps at the instant of a motor starting for example.\u003c\/p\u003e\n\u003ch5 class=\"r-faqs--faq-question j-faqs--question\"\u003eHow should I size my DC-AC inverter for loads that require starting surge?\u003c\/h5\u003e\n\u003cdiv id=\"How-should-I-size-my-DC-AC-inverter-for-loads-that-require-starting-surge\" class=\"r-faqs--faq j-faqs--single\"\u003e\n\u003cdiv class=\"r-faqs--faq-answer j-faqs--answer open\"\u003e\n\u003cp\u003eObserve the following guideline to determine the continuous wattage of the inverter for powering loads that require starting surge. (Multiply the running watts of the device\/appliance by the Surge Factor)\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003e\u003cstrong\u003eNOTE:\u003c\/strong\u003e The surge power rating specified for this inverter is valid for duration of less than 1 second. This very short duration may not be sufficient to start motor based loads which may require up to 5 seconds to complete starting process. Hence, for purposes of sizing the inverter, use only the continuous power rating of this inverter.\u003c\/em\u003e\u003c\/p\u003e\n\u003ctable class=\"tablepress tablepress-id-16 tablepress-responsive\" id=\"tablepress-16\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"row-1 odd\"\u003e\n\u003cth class=\"column-1\"\u003e\n\u003cp\u003e\u003csmall\u003eDevice \/ Appliance\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/th\u003e\n\u003cth class=\"column-2\"\u003e\n\u003cp\u003e\u003csmall\u003eSurge Factor\u003cbr\u003e(No. of times the running power rating of the device\/appliance)\u003c\/small\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody class=\"row-hover\"\u003e\n\u003ctr class=\"row-2 even\"\u003e\n\u003ctd class=\"column-1\"\u003e\n\u003cp\u003e\u003csmall\u003eRefrigerator \/ Freezer\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"column-2\"\u003e\n\u003cp\u003e\u003csmall\u003e5\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"row-3 odd\"\u003e\n\u003ctd class=\"column-1\"\u003e\n\u003cp\u003e\u003csmall\u003eAir Compressors\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"column-2\"\u003e\n\u003cp\u003e\u003csmall\u003e4\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"row-4 even\"\u003e\n\u003ctd class=\"column-1\"\u003e\n\u003cp\u003e\u003csmall\u003eDishwasher\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"column-2\"\u003e\n\u003cp\u003e\u003csmall\u003e3\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"row-5 odd\"\u003e\n\u003ctd class=\"column-1\"\u003e\n\u003cp\u003e\u003csmall\u003eSump pump\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"column-2\"\u003e\n\u003cp\u003e\u003csmall\u003e3\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"row-6 even\"\u003e\n\u003ctd class=\"column-1\"\u003e\n\u003cp\u003e\u003csmall\u003eFurnace fans\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"column-2\"\u003e\n\u003cp\u003e\u003csmall\u003e3\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"row-7 odd\"\u003e\n\u003ctd class=\"column-1\"\u003e\n\u003cp\u003e\u003csmall\u003eIndustrial motors\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"column-2\"\u003e\n\u003cp\u003e\u003csmall\u003e3\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"row-8 even\"\u003e\n\u003ctd class=\"column-1\"\u003e\n\u003cp\u003e\u003csmall\u003eCircular saw\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"column-2\"\u003e\n\u003cp\u003e\u003csmall\u003e3\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"row-9 odd\"\u003e\n\u003ctd class=\"column-1\"\u003e\n\u003cp\u003e\u003csmall\u003eBench Grinder\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"column-2\"\u003e\n\u003cp\u003e\u003csmall\u003e3\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"row-10 even\"\u003e\n\u003ctd class=\"column-1\"\u003e\n\u003cp\u003e\u003csmall\u003ePortable diesel \/ kerosene fuel heater\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"column-2\"\u003e\n\u003cp\u003e\u003csmall\u003e2\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cspan class=\"r-faqs--faq-toggle s-read-more j-faqs--toggle\"\u003e\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"r-faqs--faq j-faqs--single\"\u003e\n\u003cdiv id=\"How-should-I-size-my-DC-AC-inverter-to-operate-a-microwave\" class=\"r-faqs--faq j-faqs--single\"\u003e\n\u003ch5 class=\"r-faqs--faq-question j-faqs--question\"\u003eHow should I size my DC-AC inverter to operate a microwave?\u003c\/h5\u003e\n\u003cspan class=\"r-faqs--faq-toggle s-read-more j-faqs--toggle\"\u003e\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"r-faqs--faq j-faqs--single\"\u003e\n\u003cdiv id=\"How-should-I-size-my-DC-AC-inverter-to-operate-a-microwave\" class=\"r-faqs--faq j-faqs--single\"\u003e\n\u003cdiv class=\"r-faqs--faq-answer j-faqs--answer open\"\u003e\n\u003cp\u003eThe power rating of the microwave generally refers to the cooking power. The electrical power consumed by the microwave will be approximately 2 times the cooking power. The “surge power” of the inverter should be 2 times the electrical power (i.e., 4 times the cooking power). Please note that the surge power of the microwave is not as long as the motor load and hence, the surge power of the inverter can be considered to determine adequacy of meeting the starting surge power.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cspan class=\"r-faqs--faq-toggle s-read-more j-faqs--toggle\"\u003e\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"r-faqs--faq j-faqs--single\"\u003e\n\u003ch5 class=\"r-faqs--faq-question j-faqs--question\"\u003eHow should I size my DC-AC inverter to power a water supply pump?\u003c\/h5\u003e\n\u003cp\u003eA water well or pressure pump often places the greatest demand on the inverter. It warrants special consideration. Most pumps draw a very high surge of current during start up. The inverter must have sufficient surge capacity to handle it while running any other loads that may be on. It is important to size an inverter sufficiently, especially to handle the starting surge (If the exact starting rating is not available, the starting surge can be taken as 3 times the normal running rating of the pump). Oversize it still further if you want it to start the pump without causing lights to dim or blink.\u003c\/p\u003e\n\u003cp\u003eIn North America, most pumps (especially submersibles) run on 240 VAC, while smaller appliances and lights use 120 VAC. To obtain 240 VAC from a 120 VAC inverter, use a 120 VAC to 240 VAC transformer. If you do not already have a pump installed, you can get a 120 volt pump if you don’t need more than 1\/2 HP.\u003c\/p\u003e\n\u003ch5 class=\"r-faqs--faq-question j-faqs--question\"\u003eWhat is \"idle power\" in a DC-AC inverter?\u003c\/h5\u003e\n\u003cdiv id=\"What-is-idle-power-in-a-DC-AC-inverter\" class=\"r-faqs--faq j-faqs--single\"\u003e\n\u003cdiv class=\"r-faqs--faq-answer j-faqs--answer open\"\u003e\n\u003cp\u003eIdle power is the consumption of the inverter when it is on, but no loads are running. It is “wasted” power, so if you expect the inverter to be on for many hours during which there is very little load (as in most residential situations), you want this to be as low as possible.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cspan class=\"r-faqs--faq-toggle s-read-more j-faqs--toggle\"\u003e\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"r-faqs--faq j-faqs--single\"\u003e\n\u003ch5 class=\"r-faqs--faq-question j-faqs--question\"\u003eWhat are Phantom and idling loads?\u003c\/h5\u003e\n\u003cp\u003eMost of the modern gadgets draw some power whenever they are plugged in. Some of them use power to do nothing at all. An example is a TV with a remote control. Its electric eye system is on day and night, watching for your signal to turn the screen on. Every appliance with an external wall-plug transformer uses power even when the appliance is turned off. These little loads are called “phantom loads” because their power draw is unexpected, unseen, and easily forgotten.\u003c\/p\u003e\n\u003cp\u003eA similar concern is “idling loads.” These are devices that must be on all the time in order to function when needed. These include smoke detectors, alarm systems, motion detector lights, fax machines, and answering machines. Central heating systems have a transformer in their thermostat circuit that stays on all the time. Cordless (rechargeable) appliances draw power even after their batteries reach a full charge. If in doubt, feel the device. If it’s warm, that indicates wasted energy.\u003c\/p\u003e\n\u003ch5 class=\"r-faqs--faq-question j-faqs--question\"\u003eCan a standard DC-AC inverter be connected in parallel with another AC source\/ DC-AC inverter \/ electrical utility?\u003c\/h5\u003e\n\u003cdiv id=\"Can-a-standard-DC-AC-inverter-be-connected-in-parallel-with-another-AC-source-DC-AC-inverter-electrical-utility\" class=\"r-faqs--faq j-faqs--single\"\u003e\n\u003cdiv class=\"r-faqs--faq-answer j-faqs--answer open\"\u003e\n\u003cp\u003eThe AC output of standard inverters cannot be synchronised with another AC source and hence, it is not suitable for paralleling. The AC output of the inverter should never be connected directly to an electrical breaker panel \/ load center which is also fed from the utility power \/generator. Such a connection may result in parallel operation of the different power sources and AC power from the utility \/ generator will be fed back into the inverter which will instantly damage the output section of the inverter and may also pose a fire and safety hazard.\u003c\/p\u003e\n\u003cp\u003eIf an electrical breaker panel \/ load center is fed from an inverter and this panel is also required to be powered from additional alternate AC sources, the AC power from all the AC sources like the utility \/ generator \/ inverter should first be fed to a manual selector switch and the output of the selector switch should be connected to the electrical breaker panel \/ load center. To prevent possibility of paralleling and severe damage to the inverter, never use a simple jumper cable with a male plug on both ends to connect the AC output of the inverter to a handy wall receptacle in the home\/RV.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cspan class=\"r-faqs--faq-toggle s-read-more j-faqs--toggle\"\u003e\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"r-faqs--faq j-faqs--single\"\u003e\n\u003ch5 class=\"r-faqs--faq-question j-faqs--question\"\u003eHow can DC-AC inverters be connected to multi-wire branch circuits?\u003c\/h5\u003e\n\u003cdiv id=\"How-can-DC-AC-inverters-be-connected-to-multi-wire-branch-circuits\" class=\"r-faqs--faq j-faqs--single\"\u003e\n\u003cdiv class=\"r-faqs--faq-answer j-faqs--answer open\"\u003e\n\u003cp\u003eDo not directly connect the hot side of the inverter to the two hot legs of the 120 \/ 240 VAC electrical breaker panel \/ load centre where multi-wire ( common neutral ) branch circuit wiring method is used for distribution of AC power. This may lead to overloading\/overheating of the neutral conductor and is a risk of fire.\u003c\/p\u003e\n\u003cp\u003eA split phase transformer (isolated or auto-transformer ) of suitable wattage rating ( 25% more than the wattage rating of the inverter ) with primary of 120 VAC and secondary of 120 \/ 240 VAC ( Two 120 VAC split phases 180 degrees apart) should be used. The hot and neutral of the 120 VAC output of the inverter should be fed to the primary of this transformer and the 2 hot outputs (120 VAC split phases ) and the neutral from the secondary of this transformer should be connected to the electrical breaker panel\/ load centre.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cspan class=\"r-faqs--faq-toggle s-read-more j-faqs--toggle\"\u003e\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv id=\"How-should-I-size-my-DC-AC-inverter-to-supply-computer-or-printer-loads\" class=\"r-faqs--faq j-faqs--single\"\u003e\n\u003ch5 class=\"r-faqs--faq-question j-faqs--question\"\u003eHow should I size my DC-AC inverter to supply computer or printer loads?\u003c\/h5\u003e\n\u003cdiv id=\"How-should-I-size-my-DC-AC-inverter-to-supply-computer-or-printer-loads\" class=\"r-faqs--faq j-faqs--single\"\u003e\n\u003cdiv class=\"r-faqs--faq-answer j-faqs--answer open\"\u003e\n\u003cp\u003eComputers and Printers generally come with in-built switch-mode power supplies (see \u003ca href=\"https:\/\/samlexamerica.com\/resources-support\/application-notes\/\"\u003eapplication notes\u003c\/a\u003e and \u003ca href=\"https:\/\/samlexamerica.com\/resources-support\/faq\/inverters-powering-direct-embedded-smps\/\"\u003eFAQs on switch mode power supplies (SMPS)\u003c\/a\u003e) that have extremely low power factor on account of the extremely peaky and non-linear nature of the current drawn by them from the AC source. Hence for such loads we recommend using inverters with three times the advertised power consumption of the computer or printer loads.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cspan class=\"r-faqs--faq-toggle s-read-more j-faqs--toggle\"\u003e\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"r-faqs--faq j-faqs--single\"\u003e\n\u003ch5 class=\"r-faqs--faq-question j-faqs--question\"\u003eWhat is the difference between a 12V, 24V and 48V inverter?\u003c\/h5\u003e\n\u003cdiv class=\"o-resource-body\"\u003e\n\u003cdiv class=\"r-faqs j-faqs\"\u003e\n\u003cdiv class=\"r-faqs--container\"\u003e\n\u003cdiv class=\"r-faqs--faqs j-faqs--faqs\"\u003e\n\u003cdiv id=\"What-is-the-difference-between-a-12V-24V-and-48V-inverter\" class=\"r-faqs--faq j-faqs--single\"\u003e\n\u003cdiv class=\"r-faqs--faq-answer j-faqs--answer open\"\u003e\n\u003cp\u003eA 12-V can be fed from a 12V battery or DC supply. Similarly 24V and 48V inverters can be fed from 24V and 48V batteries\/DC power supplies, respectively. Cars usually have 12V batteries. Trucks have 24V batteries.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Samlex America","offers":[{"title":"Default Title","offer_id":50359596286235,"sku":"OGL-67246","price":121.6,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0724\/2026\/2171\/files\/67246XL.jpg?v=1749567217"},{"product_id":"samlex-5a-non-isolated-step-down-24vdc-12vdc-converter-sdc-5","title":"Samlex 5A Non-Isolated Step-Down 24VDC-12VDC Converter [SDC-5]","description":"\u003ch2\u003e\u003cspan style=\"text-decoration: underline;\"\u003eSamlex 5A Non-Isolated Step-Down 24VDC-12VDC Converter [SDC-5]\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003eThis high efficiency switch-mode step-down DC-DC converter converts an input voltage of 24 VDC nominal (range 20 VDC to 35 VDC) to a highly regulated output voltage of 12 VDC nominal (13.8 VDC) at 20 Amps. The SDC-23 DC-DC converter is non-isolated (no galvanic isolation between input and output) and meant for use in negative ground systems. Features include overvoltage\/short-circuit protection, temperature compensated current limit, output-side overvoltage protection, input-side overvoltage\/ transient protection and input-side reverse polarity protection. The SDC-23 DC-DC converter is designed for heavy duty applications.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eAdvanced switchmode design\u003c\/li\u003e\n\u003cli\u003eMount in almost any location\u003c\/li\u003e\n\u003cli\u003eCompact and light weight\u003c\/li\u003e\n\u003cli\u003eReverse polarity protection\u003c\/li\u003e\n\u003cli\u003eHigh efficiency\u003c\/li\u003e\n\u003cli\u003eCycle by cycle current limiting circuit\u003c\/li\u003e\n\u003cli\u003eOvervoltage protection\u003c\/li\u003e\n\u003cli\u003eShort circuit protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\n\u003cmeta charset=\"utf-8\"\u003eProduct Specifications\u003c\/h3\u003e\n\u003ch2\u003e\u003cspan style=\"text-decoration: underline;\"\u003eSamlex 5A Non-Isolated Step-Down 24VDC-12VDC Converter [SDC-5] Product Specifications\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eInput: 20-32 VDC\u003c\/li\u003e\n\u003cli\u003eOutput: 13.8 VDC\u003c\/li\u003e\n\u003cli\u003eAmps: 5 Amps\u003c\/li\u003e\n\u003cli\u003eWeight: 0.4 (lbs)\u003c\/li\u003e\n\u003cli\u003eWeight: 0.18 (kg)\u003c\/li\u003e\n\u003cli\u003eDimensions: 3.5 x 2.75 x 1.75 (in)\u003c\/li\u003e\n\u003cli\u003eDimensions: 8.9 x 7 x 4.4 (cm)\u003c\/li\u003e\n\u003cli\u003eWarranty: 2 Year Limited\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eEarth moving equipment\u003c\/li\u003e\n\u003cli\u003eHeavy trucks\u003c\/li\u003e\n\u003cli\u003eBuses\u003c\/li\u003e\n\u003cli\u003eMarine vehicles\u003c\/li\u003e\n\u003cli\u003eCB radios\u003c\/li\u003e\n\u003cli\u003e12 Volt lighting systems\u003c\/li\u003e\n\u003cli\u003eAM\/FM sound systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cimg alt=\"Warning\" src=\"https:\/\/productimageserver.com\/prop65\/6pt.png\"\u003e\u003cstrong\u003eWARNING:\u003c\/strong\u003e This product can expose you to chemicals which are known to the State of California to cause cancer, birth defects or other reproductive harm. For more information go to \u003ca href=\"http:\/\/P65Warnings.ca.gov\"\u003eP65Warnings.ca.gov\u003c\/a\u003e.\u003c\/p\u003e\n\u003c!--- cis2:m2lsnZdp ---\u003e\n\u003ch3\u003e\u003cspan\u003eProduct Manual\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/productimageserver.com\/literature\/ownersManual\/67247OM.pdf\" target=\"_blank\"\u003eOwner's Manual (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/productimageserver.com\/literature\/brochure\/67247BR.pdf\" target=\"_blank\"\u003eBrochure (pdf)\u003c\/a\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eProduct Warranty\u003c\/span\u003e\u003c\/h3\u003e\n\u003ch2 class=\"o-product--description\"\u003e3 Years Limited Warranty\u003c\/h2\u003e\n\u003ch3 class=\"o-product--description\"\u003eProduct FAQs\u003c\/h3\u003e\n\u003ch5 class=\"o-product--description\"\u003eWhat is a Pure Sine Wave Inverter?\u003c\/h5\u003e\n\u003cdiv class=\"o-product--description\"\u003eThe output voltage of a sine wave inverter has a sine wave form like the sine wave form of the mains \/ utility voltage. In a sine wave, the voltage rises and falls smoothly with a smoothly changing phase angle and also changes its polarity instantly when it crosses 0 Volts.\n\u003cdiv class=\"r-faqs--faq-answer j-faqs--answer open\"\u003e\n\u003cdiv id=\"What-are-the-advantages-of-Pure-Sine-Wave-inverters\" class=\"r-faqs--faq j-faqs--single\"\u003e\n\u003ch5 class=\"r-faqs--faq-question j-faqs--question\"\u003eWhat are the advantages of Pure Sine Wave inverters?\u003c\/h5\u003e\n\u003cdiv class=\"r-faqs--faq-answer j-faqs--answer open\"\u003e\n\u003cul\u003e\n\u003cli\u003eThe output wave-form is a sine-wave with\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003every low harmonic distortion\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand clean power like utility supplied electricity\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eInductive loads\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003elike microwaves and motors run faster, quieter and cooler\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eReduces audible and electrical noise\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ein fans, fluorescent lights, audio amplifiers, TV, fax and answering machines\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePrevents crashes\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ein computers, weird print outs and glitches in monitors\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cspan class=\"r-faqs--faq-toggle s-read-more j-faqs--toggle\"\u003e\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"r-faqs--faq j-faqs--single\"\u003e\n\u003cdiv id=\"What-is-a-Modified-Sine-Wave-Inverter\" class=\"r-faqs--faq j-faqs--single\"\u003e\n\u003ch5 class=\"r-faqs--faq-question j-faqs--question\"\u003eWhat is a Modified Sine Wave Inverter?\u003c\/h5\u003e\n\u003cdiv class=\"r-faqs--faq-answer j-faqs--answer open\"\u003e\n\u003cp\u003eIn a modified sine wave, the voltage rises and falls abruptly, the phase angle also changes abruptly and it sits at 0 Volts for some time before changing its polarity.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cspan class=\"r-faqs--faq-toggle s-read-more j-faqs--toggle\"\u003e\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"r-faqs--faq j-faqs--single\"\u003e\n\u003ch5 class=\"r-faqs--faq-question j-faqs--question\"\u003eWhat are the advantages of Pure Sine Wave inverters?\u003c\/h5\u003e\n\u003cdiv class=\"r-faqs--faq-answer j-faqs--answer open\"\u003e\n\u003cul\u003e\n\u003cli\u003eThe output wave-form is a sine-wave with\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003every low harmonic distortion\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand clean power like utility supplied electricity\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eInductive loads\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003elike microwaves and motors run faster, quieter and cooler\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eReduces audible and electrical noise\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ein fans, fluorescent lights, audio amplifiers, TV, fax and answering machines\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePrevents crashes\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ein computers, weird print outs and glitches in monitors\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"o-resource-body\"\u003e\n\u003cdiv class=\"r-faqs j-faqs\"\u003e\n\u003cdiv class=\"r-faqs--container\"\u003e\n\u003cdiv class=\"r-faqs--faqs j-faqs--faqs\"\u003e\n\u003cdiv id=\"Which-devices-will-not-function-properly-from-a-Modified-Sine-Wave-Inverter\" class=\"r-faqs--faq j-faqs--single\"\u003e\n\u003ch5 class=\"r-faqs--faq-question j-faqs--question\"\u003eWhich devices will not function properly from a Modified Sine Wave Inverter?\u003c\/h5\u003e\n\u003cdiv class=\"r-faqs--faq-answer j-faqs--answer open\"\u003e\n\u003cp\u003eAny device that uses a control circuitry that senses the phase (for voltage \/ speed control) or instantaneous zero voltage crossing (for timing control) will not work properly from a voltage that has a modified sine wave-form. Also, as the modified sine wave is a form of square wave, it is comprised of multiple sine waves of odd harmonics (multiples) of the fundamental frequency of the modified sine wave. For example, a 60 Hz. modified sine wave will consist of sine waves with odd harmonic frequencies of 3rd (180 Hz), 5th (300 Hz.), 7th (420 Hz.) and so on. The high frequency harmonic content in a modified sine wave produces enhanced radio interference, higher heating effect in motors \/ microwaves and produces overloading due to lowering of the impedance of low frequency filter capacitors \/ power factor improvement capacitors.\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eSome examples of devices that may not work properly with modified sine wave and may also get damaged are given below\u003c\/em\u003e\u003c\/p\u003e\n\u003cul type=\"circle\"\u003e\n\u003cli\u003eLaser printers, photocopiers, magneto-optical hard drives\u003c\/li\u003e\n\u003cli\u003eThe built-in clocks in devices such as clock radios, alarm clocks, coffee makers, bread-makers, VCR, microwave ovens etc may not keep time correctly\u003c\/li\u003e\n\u003cli\u003eOutput voltage control devices like dimmers, ceiling fan \/ motor speed control may not work properly (dimming \/ speed control may not function)\u003c\/li\u003e\n\u003cli\u003eSewing machines with speed \/ microprocessor control\u003c\/li\u003e\n\u003cli\u003eTransformer-less capacitive input powered devices like (i) Razors, flashlights, night-lights, smoke detectors etc (ii) Re-chargers for battery packs used in hand power tools.\u003cspan\u003e \u003c\/span\u003e\u003cem\u003eThese may get damaged. Please check with the manufacturer of these types of devices for suitability\u003c\/em\u003e\n\u003c\/li\u003e\n\u003cli\u003eDevices that use radio frequency signals carried by the AC distribution wiring\u003c\/li\u003e\n\u003cli\u003eSome new furnaces with microprocessor control \/ Oil burner primary controls\u003c\/li\u003e\n\u003cli\u003eHigh intensity discharge (HID) lamps like Metal Halide lamps.\u003cspan\u003e \u003c\/span\u003e\u003cem\u003eThese may get damaged. Please check with the manufacturer of these types of devices for suitability\u003c\/em\u003e\n\u003c\/li\u003e\n\u003cli\u003eSome fluorescent lamps \/ light fixtures that have power factor correction capacitors.\u003cspan\u003e \u003c\/span\u003e\u003cem\u003eThe inverter may shut down indicating overload\u003c\/em\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5 class=\"r-faqs--faq-question j-faqs--question\"\u003eWhat is a DC-AC inverter?\u003c\/h5\u003e\n\u003cp\u003eWhen you plug anything into the wall in your home you are usually “plugging in” to the power-grid provided as a service by your utility company. Your utility company supplies you with alternating current (AC) electricity. AC electricity flows in alternate directions many times per second. AC is used for utility grid service because it is more practical for long distance transmission.\u003c\/p\u003e\n\u003cp\u003eBatteries provide direct current electricity (DC) electricity which flows in a single direction.  DC power is what is used in many electronics in the home like laptops, solar cells, LED bulbs, and electric vehicles.  They usually have built-in converters to take the AC power received from a plug-in and convert it to DC.\u003c\/p\u003e\n\u003cp\u003eAn inverter (converter) acts as a power adapter as it converts DC to AC,  AC to DC, and can also change the voltage. It allows a battery-based system to run conventional AC appliances directly or through conventional home wiring.\u003c\/p\u003e\n\u003ch5 class=\"r-faqs--faq-question j-faqs--question\"\u003eWhat are the criteria for selecting the right inverter for a particular application?\u003c\/h5\u003e\n\u003cdiv class=\"r-faqs--faq j-faqs--single\" id=\"What-are-the-criteria-for-selecting-the-right-inverter-for-a-particular-application\"\u003e\n\u003cdiv class=\"r-faqs--faq-answer j-faqs--answer open\"\u003e\n\u003cp\u003eTo choose an inverter; you should first define your needs. Where is the inverter to be used? Inverters are available for use in buildings (including homes), for recreational vehicles, boats, and portable applications. Will it be connected to the utility grid in some way? Electrical conventions and safety standards differ for various applications, so don’t improvise.\u003c\/p\u003e\n\u003cp\u003eWhen sizing an inverter, you need to take into consideration both the\u003cstrong\u003e\u003cem\u003e\u003cspan\u003e \u003c\/span\u003erunning power\u003c\/em\u003e\u003c\/strong\u003e \u003cspan\u003e \u003c\/span\u003e\u003cem\u003e\u003cstrong\u003e(continuous)\u003c\/strong\u003e\u003c\/em\u003e\u003cspan\u003e \u003c\/span\u003eand the additional\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e\u003cem\u003estarting surge power\u003c\/em\u003e\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003erequirements of the AC side loads.\u003c\/p\u003e\n\u003cp\u003eSome loads require much higher starting surge power for the first few seconds before settling down at the running power. The inverter should be sized on the basis of the starting surge power of the AC side load. The total starting surge power is equal to the normal running power plus the additional starting power. The following symbols and equation will be used for explanation purposes:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eRunning Power, Watts – \u003cstrong\u003eWr\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eAdditional Starting Power or Additional Continuous Power, Watts – \u003cstrong\u003eWa\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eTotal Starting Surge Power, Watts = Running Power (\u003cstrong\u003eWr\u003c\/strong\u003e) + Additional Starting Power \/ Additional Continuous Power (\u003cstrong\u003eWa\u003c\/strong\u003e)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe specifications of inverters may include a rating termed Surge Power. Normally, the duration of this Surge Power rating is not quantified in the specifications and is assumed to last for less than 1 second. Unless the Surge Power Rating of the inverter is specified to last for \u0026gt; 5 seconds, this Surge Power specification of the inverter should not be considered for purposes of sizing loads with high and prolonged starting surge power.\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eOnly the Continuous Power rating of the inverter should be considered in such cases\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eElectric motor driven compressor\/pump based loads like refrigerators\/freezers, air conditioners, air compressors, sump and well pumps, etc. require a very high Starting Surge Power of around 5 to 7 times the Running Power for the initial start up. This Starting Surge Power may last for 2 to 5 seconds.  The Additional Starting Power\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eWa\u003c\/strong\u003e should be taken as 4 times the Running Power \u003cstrong\u003eWr\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eSwitched Mode Power Supplies (SMPS) that do not have Power Factor correction draw a non linear, pulsing current with a high Crest Factor (Ratio of instantaneous value and the RMS value) that may reach a value of 4. Also, the effective Power Factor of these types of power supplies is very low around 0.6. If the inverter is sized based on the Running Power of these units, the inverter will be continuously overloaded from instant to instant due to the higher peaks of the pulsing current. The inverter for these units should be sized at 3 times the Running Power of the power supply. Alternatively, for sizing purposes, the Additional Continuous Power \u003cstrong\u003eWa\u003c\/strong\u003e should be taken as 2 times the Running Power \u003cstrong\u003eWr\u003c\/strong\u003e. Consumer electronics like computers, TV, VCR, audio\/ video devices, etc. use this type of power supply.\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e(Please note that this sizing is not applicable if the SMPS has Power Factor correction and the Power Factor is around 0.9)\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eMotors used in washing machines have to start under load due to the weight of the clothes, water and the drum. Hence, the Additional Starting Power \u003cstrong\u003eWa\u003c\/strong\u003e should be taken as 2 times the Running Power \u003cstrong\u003eWr\u003c\/strong\u003e. This starting power normally lasts from 2 to 5 seconds.\u003c\/p\u003e\n\u003cp\u003eThe Watt rating of the microwaves normally indicates output cooking power in Watts. As the microwave is not an efficient device, the AC input power in Watts should be taken as 2 times the output cooking power in Watts i.e. the Additional Continuous Power \u003cstrong\u003eWa\u003c\/strong\u003e should be taken as 1 time the Running Power \u003cstrong\u003eWr\u003c\/strong\u003e. Hence, a microwave with 900 Watt cooking power will require an 1800 Watt inverter. \u003cstrong\u003e(If the power rating of the inverter is indicated as the AC input power in Watts, the factor of 2 is not applicable).\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe following symbols and equations are used in the sizing of an inverter example below:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTotal Running Power of the items selected, Watts – \u003cstrong\u003eWrt\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eHighest Additional Starting Power out of the items selected, Watts – \u003cstrong\u003eWah\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e*Highest power for sizing purpose, Watts – \u003cstrong\u003eWrt + Wah\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003e* It is assumed that only one out of the selected items starts at one time\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003eSince the AC loads rarely start at the same time, the load with the highest Additional Starting Power \u003cstrong\u003eWah\u003c\/strong\u003e has been factored in.\u003c\/p\u003e\n\u003cp\u003eExample:\u003cbr\u003e\u003c\/p\u003e\n\u003ctable id=\"tablepress-15\" class=\"tablepress tablepress-id-15 tablepress-responsive\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"row-1 odd\"\u003e\n\u003cth class=\"column-1\"\u003e\n\u003cp\u003e\u003csmall\u003eDevice \/ Appliance\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/th\u003e\n\u003cth class=\"column-2\"\u003e\n\u003cp\u003e\u003csmall\u003eRunning Power, Wr, Watts\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/th\u003e\n\u003cth class=\"column-3\"\u003e\n\u003cp\u003e\u003csmall\u003eAdditional\u003cbr\u003eStarting Power or Additional Continuous Power *, Wa, Watts\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/th\u003e\n\u003cth class=\"column-4\"\u003e\n\u003cp\u003e\u003csmall\u003eQuantity\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/th\u003e\n\u003cth class=\"column-5\"\u003e\n\u003cp\u003e\u003csmall\u003eExtended\u003cbr\u003eRunning Power, Wt, Watts\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody class=\"row-hover\"\u003e\n\u003ctr class=\"row-2 even\"\u003e\n\u003ctd class=\"column-1\"\u003e\n\u003cp\u003e\u003csmall\u003eRefrigerator – Electric Compressor based\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"column-2\"\u003e\n\u003cp\u003e\u003csmall\u003e200\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"column-3\"\u003e\n\u003cp\u003e\u003csmall\u003e800\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"column-4\"\u003e\n\u003cp\u003e\u003csmall\u003e1\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"column-5\"\u003e\n\u003cp\u003e\u003csmall\u003e200\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"row-3 odd\"\u003e\n\u003ctd class=\"column-1\"\u003e\n\u003cp\u003e\u003csmall\u003eColor TV\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"column-2\"\u003e\n\u003cp\u003e\u003csmall\u003e225\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"column-3\"\u003e\n\u003cp\u003e\u003csmall\u003e450\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"column-4\"\u003e\n\u003cp\u003e\u003csmall\u003e1\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"column-5\"\u003e\n\u003cp\u003e\u003csmall\u003e225\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"row-4 even\"\u003e\n\u003ctd class=\"column-1\"\u003e\n\u003cp\u003e\u003csmall\u003eLaptop Adapter\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"column-2\"\u003e\n\u003cp\u003e\u003csmall\u003e120\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"column-3\"\u003e\n\u003cp\u003e\u003csmall\u003e240\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"column-4\"\u003e\n\u003cp\u003e\u003csmall\u003e1\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"column-5\"\u003e\n\u003cp\u003e\u003csmall\u003e120\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"row-5 odd\"\u003e\n\u003ctd class=\"column-1\"\u003e\n\u003cp\u003e\u003csmall\u003eIncandescent Lamps\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"column-2\"\u003e\n\u003cp\u003e\u003csmall\u003e60\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"column-3\"\u003e\n\u003cp\u003e\u003csmall\u003e0\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"column-4\"\u003e\n\u003cp\u003e\u003csmall\u003e6\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"column-5\"\u003e\n\u003cp\u003e\u003csmall\u003e360\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e*\u003c\/strong\u003e \u003cem\u003eAdditional Continuous Power is applicable to SMPS based loads that have no Power Factor Correction.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003eTotal Extended Running Power, \u003cstrong\u003eWrt\u003c\/strong\u003e = 200 + 225 + 120 + 360 = \u003cstrong\u003e905\u003c\/strong\u003e Watts\u003c\/p\u003e\n\u003cp\u003eHighest Additional Starting Power, \u003cstrong\u003eWah\u003c\/strong\u003e = \u003cstrong\u003e800\u003c\/strong\u003e Watts\u003c\/p\u003e\n\u003cp\u003eHighest Power for sizing the inverter = Total Running Power, \u003cstrong\u003eWrt\u003c\/strong\u003e(905 W) + Highest Additional Starting Power, \u003cstrong\u003eWah\u003c\/strong\u003e (800 W) = \u003cstrong\u003e1705\u003c\/strong\u003e Watts\u003c\/p\u003e\n\u003ch5 class=\"r-faqs--faq-question j-faqs--question\"\u003eWhat are the electrical standards pertaining to DC-AC inverters?\u003c\/h5\u003e\n\u003cdiv class=\"r-faqs--faq-answer j-faqs--answer open\"\u003e\n\u003cmeta charset=\"utf-8\"\u003e\n\u003cp\u003eThe DC input voltage must conform to that of the electrical system and battery bank. 12 volts is recommended for small, simple systems. 24 and 48 volts are the common standards for higher capacities. A higher voltage system carries less current, which makes the system wiring cheaper and easier.\u003c\/p\u003e\n\u003cp\u003eThe inverter’s AC output must conform to the conventional power in the region to run locally available appliances. The standard for AC utility service in North America is 120 and 240 Volts at a frequency of 60 Hertz (cycles per second). In Europe, South America, and most other places, it is 230 volts at 50 Hertz.\u003c\/p\u003e\n\u003ch5 class=\"r-faqs--faq-question j-faqs--question\"\u003eWhat are \"continuous\" and \"surge\" power capacity ratings for DC-AC inverters?\u003c\/h5\u003e\n\u003cdiv class=\"r-faqs--faq j-faqs--single\" id=\"What-are-continuous-and-surge-power-capacity-ratings-for-DC-AC-inverters\"\u003e\n\u003cdiv class=\"r-faqs--faq-answer j-faqs--answer open\"\u003e\n\u003cp\u003eHow much load can an inverter handle? Its power output is rated in Watts.  There are two levels of power rating -a continuous rating and a surge rating. Continuous means the amount of power the inverter can handle for an indefinite period of hours. When an inverter is rated at a certain number of Watts, that number generally refers to its continuous rating. The “surge power” indicates the power to handle instantaneous overload of a few seconds to provide the higher power required to start certain type of devices and appliances.  Resistive types of loads (like incandescent lamps, toaster, coffee maker, electric range, iron etc) do not require extra power to start. Their starting power is the same as their running power.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cspan class=\"r-faqs--faq-toggle s-read-more j-faqs--toggle\"\u003e\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"r-faqs--faq j-faqs--single\"\u003e\n\u003ch5 class=\"r-faqs--faq-question j-faqs--question\"\u003eHow do \"surge power\" electrical loads affect DC-AC inverter operation?\u003c\/h5\u003e\n\u003cp\u003eIf an inverter cannot efficiently feed the surge power, it may simply shut down instead of starting the device. If the inverter’s surge capacity is marginal, its output voltage will dip during the surge. This can cause a dimming of the lights in the house, and will sometimes crash a computer.\u003c\/p\u003e\n\u003cp\u003eAny weakness in the battery and cabling to the inverter will further limit its ability to start a motor. A battery bank that is undersized, in poor condition, or has corroded connections, can be a weak link in the power chain. The inverter cables and the battery interconnect cables must be sized properly. The spike of DC current through these cables is many hundreds of amps at the instant of a motor starting for example.\u003c\/p\u003e\n\u003ch5 class=\"r-faqs--faq-question j-faqs--question\"\u003eHow should I size my DC-AC inverter for loads that require starting surge?\u003c\/h5\u003e\n\u003cdiv class=\"r-faqs--faq j-faqs--single\" id=\"How-should-I-size-my-DC-AC-inverter-for-loads-that-require-starting-surge\"\u003e\n\u003cdiv class=\"r-faqs--faq-answer j-faqs--answer open\"\u003e\n\u003cp\u003eObserve the following guideline to determine the continuous wattage of the inverter for powering loads that require starting surge. (Multiply the running watts of the device\/appliance by the Surge Factor)\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003e\u003cstrong\u003eNOTE:\u003c\/strong\u003e The surge power rating specified for this inverter is valid for duration of less than 1 second. This very short duration may not be sufficient to start motor based loads which may require up to 5 seconds to complete starting process. Hence, for purposes of sizing the inverter, use only the continuous power rating of this inverter.\u003c\/em\u003e\u003c\/p\u003e\n\u003ctable id=\"tablepress-16\" class=\"tablepress tablepress-id-16 tablepress-responsive\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"row-1 odd\"\u003e\n\u003cth class=\"column-1\"\u003e\n\u003cp\u003e\u003csmall\u003eDevice \/ Appliance\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/th\u003e\n\u003cth class=\"column-2\"\u003e\n\u003cp\u003e\u003csmall\u003eSurge Factor\u003cbr\u003e(No. of times the running power rating of the device\/appliance)\u003c\/small\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody class=\"row-hover\"\u003e\n\u003ctr class=\"row-2 even\"\u003e\n\u003ctd class=\"column-1\"\u003e\n\u003cp\u003e\u003csmall\u003eRefrigerator \/ Freezer\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"column-2\"\u003e\n\u003cp\u003e\u003csmall\u003e5\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"row-3 odd\"\u003e\n\u003ctd class=\"column-1\"\u003e\n\u003cp\u003e\u003csmall\u003eAir Compressors\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"column-2\"\u003e\n\u003cp\u003e\u003csmall\u003e4\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"row-4 even\"\u003e\n\u003ctd class=\"column-1\"\u003e\n\u003cp\u003e\u003csmall\u003eDishwasher\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"column-2\"\u003e\n\u003cp\u003e\u003csmall\u003e3\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"row-5 odd\"\u003e\n\u003ctd class=\"column-1\"\u003e\n\u003cp\u003e\u003csmall\u003eSump pump\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"column-2\"\u003e\n\u003cp\u003e\u003csmall\u003e3\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"row-6 even\"\u003e\n\u003ctd class=\"column-1\"\u003e\n\u003cp\u003e\u003csmall\u003eFurnace fans\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"column-2\"\u003e\n\u003cp\u003e\u003csmall\u003e3\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"row-7 odd\"\u003e\n\u003ctd class=\"column-1\"\u003e\n\u003cp\u003e\u003csmall\u003eIndustrial motors\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"column-2\"\u003e\n\u003cp\u003e\u003csmall\u003e3\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"row-8 even\"\u003e\n\u003ctd class=\"column-1\"\u003e\n\u003cp\u003e\u003csmall\u003eCircular saw\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"column-2\"\u003e\n\u003cp\u003e\u003csmall\u003e3\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"row-9 odd\"\u003e\n\u003ctd class=\"column-1\"\u003e\n\u003cp\u003e\u003csmall\u003eBench Grinder\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"column-2\"\u003e\n\u003cp\u003e\u003csmall\u003e3\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"row-10 even\"\u003e\n\u003ctd class=\"column-1\"\u003e\n\u003cp\u003e\u003csmall\u003ePortable diesel \/ kerosene fuel heater\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"column-2\"\u003e\n\u003cp\u003e\u003csmall\u003e2\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cspan class=\"r-faqs--faq-toggle s-read-more j-faqs--toggle\"\u003e\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"r-faqs--faq j-faqs--single\"\u003e\n\u003cdiv class=\"r-faqs--faq j-faqs--single\" id=\"How-should-I-size-my-DC-AC-inverter-to-operate-a-microwave\"\u003e\n\u003ch5 class=\"r-faqs--faq-question j-faqs--question\"\u003eHow should I size my DC-AC inverter to operate a microwave?\u003c\/h5\u003e\n\u003cspan class=\"r-faqs--faq-toggle s-read-more j-faqs--toggle\"\u003e\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"r-faqs--faq j-faqs--single\"\u003e\n\u003cdiv class=\"r-faqs--faq j-faqs--single\" id=\"How-should-I-size-my-DC-AC-inverter-to-operate-a-microwave\"\u003e\n\u003cdiv class=\"r-faqs--faq-answer j-faqs--answer open\"\u003e\n\u003cp\u003eThe power rating of the microwave generally refers to the cooking power. The electrical power consumed by the microwave will be approximately 2 times the cooking power. The “surge power” of the inverter should be 2 times the electrical power (i.e., 4 times the cooking power). Please note that the surge power of the microwave is not as long as the motor load and hence, the surge power of the inverter can be considered to determine adequacy of meeting the starting surge power.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cspan class=\"r-faqs--faq-toggle s-read-more j-faqs--toggle\"\u003e\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"r-faqs--faq j-faqs--single\"\u003e\n\u003ch5 class=\"r-faqs--faq-question j-faqs--question\"\u003eHow should I size my DC-AC inverter to power a water supply pump?\u003c\/h5\u003e\n\u003cp\u003eA water well or pressure pump often places the greatest demand on the inverter. It warrants special consideration. Most pumps draw a very high surge of current during start up. The inverter must have sufficient surge capacity to handle it while running any other loads that may be on. It is important to size an inverter sufficiently, especially to handle the starting surge (If the exact starting rating is not available, the starting surge can be taken as 3 times the normal running rating of the pump). Oversize it still further if you want it to start the pump without causing lights to dim or blink.\u003c\/p\u003e\n\u003cp\u003eIn North America, most pumps (especially submersibles) run on 240 VAC, while smaller appliances and lights use 120 VAC. To obtain 240 VAC from a 120 VAC inverter, use a 120 VAC to 240 VAC transformer. If you do not already have a pump installed, you can get a 120 volt pump if you don’t need more than 1\/2 HP.\u003c\/p\u003e\n\u003ch5 class=\"r-faqs--faq-question j-faqs--question\"\u003eWhat is \"idle power\" in a DC-AC inverter?\u003c\/h5\u003e\n\u003cdiv class=\"r-faqs--faq j-faqs--single\" id=\"What-is-idle-power-in-a-DC-AC-inverter\"\u003e\n\u003cdiv class=\"r-faqs--faq-answer j-faqs--answer open\"\u003e\n\u003cp\u003eIdle power is the consumption of the inverter when it is on, but no loads are running. It is “wasted” power, so if you expect the inverter to be on for many hours during which there is very little load (as in most residential situations), you want this to be as low as possible.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cspan class=\"r-faqs--faq-toggle s-read-more j-faqs--toggle\"\u003e\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"r-faqs--faq j-faqs--single\"\u003e\n\u003ch5 class=\"r-faqs--faq-question j-faqs--question\"\u003eWhat are Phantom and idling loads?\u003c\/h5\u003e\n\u003cp\u003eMost of the modern gadgets draw some power whenever they are plugged in. Some of them use power to do nothing at all. An example is a TV with a remote control. Its electric eye system is on day and night, watching for your signal to turn the screen on. Every appliance with an external wall-plug transformer uses power even when the appliance is turned off. These little loads are called “phantom loads” because their power draw is unexpected, unseen, and easily forgotten.\u003c\/p\u003e\n\u003cp\u003eA similar concern is “idling loads.” These are devices that must be on all the time in order to function when needed. These include smoke detectors, alarm systems, motion detector lights, fax machines, and answering machines. Central heating systems have a transformer in their thermostat circuit that stays on all the time. Cordless (rechargeable) appliances draw power even after their batteries reach a full charge. If in doubt, feel the device. If it’s warm, that indicates wasted energy.\u003c\/p\u003e\n\u003ch5 class=\"r-faqs--faq-question j-faqs--question\"\u003eCan a standard DC-AC inverter be connected in parallel with another AC source\/ DC-AC inverter \/ electrical utility?\u003c\/h5\u003e\n\u003cdiv class=\"r-faqs--faq j-faqs--single\" id=\"Can-a-standard-DC-AC-inverter-be-connected-in-parallel-with-another-AC-source-DC-AC-inverter-electrical-utility\"\u003e\n\u003cdiv class=\"r-faqs--faq-answer j-faqs--answer open\"\u003e\n\u003cp\u003eThe AC output of standard inverters cannot be synchronised with another AC source and hence, it is not suitable for paralleling. The AC output of the inverter should never be connected directly to an electrical breaker panel \/ load center which is also fed from the utility power \/generator. Such a connection may result in parallel operation of the different power sources and AC power from the utility \/ generator will be fed back into the inverter which will instantly damage the output section of the inverter and may also pose a fire and safety hazard.\u003c\/p\u003e\n\u003cp\u003eIf an electrical breaker panel \/ load center is fed from an inverter and this panel is also required to be powered from additional alternate AC sources, the AC power from all the AC sources like the utility \/ generator \/ inverter should first be fed to a manual selector switch and the output of the selector switch should be connected to the electrical breaker panel \/ load center. To prevent possibility of paralleling and severe damage to the inverter, never use a simple jumper cable with a male plug on both ends to connect the AC output of the inverter to a handy wall receptacle in the home\/RV.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cspan class=\"r-faqs--faq-toggle s-read-more j-faqs--toggle\"\u003e\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"r-faqs--faq j-faqs--single\"\u003e\n\u003ch5 class=\"r-faqs--faq-question j-faqs--question\"\u003eHow can DC-AC inverters be connected to multi-wire branch circuits?\u003c\/h5\u003e\n\u003cdiv class=\"r-faqs--faq j-faqs--single\" id=\"How-can-DC-AC-inverters-be-connected-to-multi-wire-branch-circuits\"\u003e\n\u003cdiv class=\"r-faqs--faq-answer j-faqs--answer open\"\u003e\n\u003cp\u003eDo not directly connect the hot side of the inverter to the two hot legs of the 120 \/ 240 VAC electrical breaker panel \/ load centre where multi-wire ( common neutral ) branch circuit wiring method is used for distribution of AC power. This may lead to overloading\/overheating of the neutral conductor and is a risk of fire.\u003c\/p\u003e\n\u003cp\u003eA split phase transformer (isolated or auto-transformer ) of suitable wattage rating ( 25% more than the wattage rating of the inverter ) with primary of 120 VAC and secondary of 120 \/ 240 VAC ( Two 120 VAC split phases 180 degrees apart) should be used. The hot and neutral of the 120 VAC output of the inverter should be fed to the primary of this transformer and the 2 hot outputs (120 VAC split phases ) and the neutral from the secondary of this transformer should be connected to the electrical breaker panel\/ load centre.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cspan class=\"r-faqs--faq-toggle s-read-more j-faqs--toggle\"\u003e\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"r-faqs--faq j-faqs--single\" id=\"How-should-I-size-my-DC-AC-inverter-to-supply-computer-or-printer-loads\"\u003e\n\u003ch5 class=\"r-faqs--faq-question j-faqs--question\"\u003eHow should I size my DC-AC inverter to supply computer or printer loads?\u003c\/h5\u003e\n\u003cdiv class=\"r-faqs--faq j-faqs--single\" id=\"How-should-I-size-my-DC-AC-inverter-to-supply-computer-or-printer-loads\"\u003e\n\u003cdiv class=\"r-faqs--faq-answer j-faqs--answer open\"\u003e\n\u003cp\u003eComputers and Printers generally come with in-built switch-mode power supplies (see \u003ca href=\"https:\/\/samlexamerica.com\/resources-support\/application-notes\/\"\u003eapplication notes\u003c\/a\u003e and \u003ca href=\"https:\/\/samlexamerica.com\/resources-support\/faq\/inverters-powering-direct-embedded-smps\/\"\u003eFAQs on switch mode power supplies (SMPS)\u003c\/a\u003e) that have extremely low power factor on account of the extremely peaky and non-linear nature of the current drawn by them from the AC source. Hence for such loads we recommend using inverters with three times the advertised power consumption of the computer or printer loads.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cspan class=\"r-faqs--faq-toggle s-read-more j-faqs--toggle\"\u003e\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"r-faqs--faq j-faqs--single\"\u003e\n\u003ch5 class=\"r-faqs--faq-question j-faqs--question\"\u003eWhat is the difference between a 12V, 24V and 48V inverter?\u003c\/h5\u003e\n\u003cdiv class=\"o-resource-body\"\u003e\n\u003cdiv class=\"r-faqs j-faqs\"\u003e\n\u003cdiv class=\"r-faqs--container\"\u003e\n\u003cdiv class=\"r-faqs--faqs j-faqs--faqs\"\u003e\n\u003cdiv class=\"r-faqs--faq j-faqs--single\" id=\"What-is-the-difference-between-a-12V-24V-and-48V-inverter\"\u003e\n\u003cdiv class=\"r-faqs--faq-answer j-faqs--answer open\"\u003e\n\u003cp\u003eA 12-V can be fed from a 12V battery or DC supply. Similarly 24V and 48V inverters can be fed from 24V and 48V batteries\/DC power supplies, respectively. Cars usually have 12V batteries. Trucks have 24V batteries.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Samlex America","offers":[{"title":"Default Title","offer_id":50359596319003,"sku":"OGL-67247","price":52.5,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0724\/2026\/2171\/files\/67247XL.jpg?v=1749567217"},{"product_id":"samlex-30a-non-isolated-step-down-24vdc-12vdc-converter-sdc-30","title":"Samlex 30A Non-Isolated Step-Down 24VDC-12VDC Converter [SDC-30]","description":"\u003ch2\u003e\u003cspan style=\"text-decoration: underline;\"\u003eSamlex 30A Non-Isolated Step-Down 24VDC-12VDC Converter [SDC-30]\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003eThis high efficiency switch-mode step-down DC-DC converter converts an input voltage of 24 VDC nominal (range 20 VDC to 32 VDC) to a highly regulated output voltage of 12 VDC nominal (13.8 VDC) at 30 Amps. The SDC-30 DC-DC converter is non-isolated (no galvanic isolation between input and output) and meant for use in negative ground systems. Features include overload, over-heating, reverse polarity and over-voltage protection.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eAdvanced switchmode design\u003c\/li\u003e\n\u003cli\u003eMount in almost any location\u003c\/li\u003e\n\u003cli\u003eCompact and light weight\u003c\/li\u003e\n\u003cli\u003eReverse polarity protection\u003c\/li\u003e\n\u003cli\u003eHigh efficiency\u003c\/li\u003e\n\u003cli\u003eCycle by cycle current limiting circuit\u003c\/li\u003e\n\u003cli\u003eOvervoltage protection\u003c\/li\u003e\n\u003cli\u003eShort circuit protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\n\u003cmeta charset=\"utf-8\"\u003eProduct Specifications\u003c\/h3\u003e\n\u003ch2\u003e\u003cspan style=\"text-decoration: underline;\"\u003eSamlex 30A Non-Isolated Step-Down 24VDC-12VDC Converter [SDC-30] Product Specifications\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eInput: 20-32 VDC\u003c\/li\u003e\n\u003cli\u003eOutput: 13.8 VDC\u003c\/li\u003e\n\u003cli\u003eAmps: 30 Amps\u003c\/li\u003e\n\u003cli\u003eWeight: 1.2 (lbs)\u003c\/li\u003e\n\u003cli\u003eWeight: 0.54 (kg)\u003c\/li\u003e\n\u003cli\u003eDimensions: 6 x 3.5 x 1.9 (in)\u003c\/li\u003e\n\u003cli\u003eDimensions: 15.2 x 8.9 x 4.8 (cm)\u003c\/li\u003e\n\u003cli\u003eWarranty: 2 Year Limited\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eEarth moving equipment\u003c\/li\u003e\n\u003cli\u003eHeavy trucks\u003c\/li\u003e\n\u003cli\u003eBuses\u003c\/li\u003e\n\u003cli\u003eMarine vehicles\u003c\/li\u003e\n\u003cli\u003eCB radios\u003c\/li\u003e\n\u003cli\u003e12 Volt lighting systems\u003c\/li\u003e\n\u003cli\u003eAM\/FM sound systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/productimageserver.com\/prop65\/6pt.png\" alt=\"Warning\"\u003e\u003cstrong\u003eWARNING:\u003c\/strong\u003e This product can expose you to chemicals which are known to the State of California to cause cancer, birth defects or other reproductive harm. For more information go to \u003ca href=\"http:\/\/P65Warnings.ca.gov\"\u003eP65Warnings.ca.gov\u003c\/a\u003e.\u003c\/p\u003e\n\u003c!--- cis2:m2lsnZdp ---\u003e\n\u003ch3\u003e\u003cspan\u003eProduct Manual\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/productimageserver.com\/literature\/ownersManual\/67249OM.pdf\" target=\"_blank\"\u003eOwner's Manual (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/productimageserver.com\/literature\/brochure\/67249BR.pdf\" target=\"_blank\"\u003eBrochure (pdf)\u003c\/a\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eProduct Warranty\u003c\/span\u003e\u003c\/h3\u003e\n\u003ch2 class=\"o-product--description\"\u003e3 Years Limited Warranty\u003c\/h2\u003e\n\u003ch3 class=\"o-product--description\"\u003eProduct FAQs\u003c\/h3\u003e\n\u003ch5 class=\"o-product--description\"\u003eWhat is a Pure Sine Wave Inverter?\u003c\/h5\u003e\n\u003cdiv class=\"o-product--description\"\u003eThe output voltage of a sine wave inverter has a sine wave form like the sine wave form of the mains \/ utility voltage. In a sine wave, the voltage rises and falls smoothly with a smoothly changing phase angle and also changes its polarity instantly when it crosses 0 Volts.\n\u003cdiv class=\"r-faqs--faq-answer j-faqs--answer open\"\u003e\n\u003cdiv class=\"r-faqs--faq j-faqs--single\" id=\"What-are-the-advantages-of-Pure-Sine-Wave-inverters\"\u003e\n\u003ch5 class=\"r-faqs--faq-question j-faqs--question\"\u003eWhat are the advantages of Pure Sine Wave inverters?\u003c\/h5\u003e\n\u003cdiv class=\"r-faqs--faq-answer j-faqs--answer open\"\u003e\n\u003cul\u003e\n\u003cli\u003eThe output wave-form is a sine-wave with\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003every low harmonic distortion\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand clean power like utility supplied electricity\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eInductive loads\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003elike microwaves and motors run faster, quieter and cooler\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eReduces audible and electrical noise\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ein fans, fluorescent lights, audio amplifiers, TV, fax and answering machines\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePrevents crashes\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ein computers, weird print outs and glitches in monitors\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cspan class=\"r-faqs--faq-toggle s-read-more j-faqs--toggle\"\u003e\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"r-faqs--faq j-faqs--single\"\u003e\n\u003cdiv class=\"r-faqs--faq j-faqs--single\" id=\"What-is-a-Modified-Sine-Wave-Inverter\"\u003e\n\u003ch5 class=\"r-faqs--faq-question j-faqs--question\"\u003eWhat is a Modified Sine Wave Inverter?\u003c\/h5\u003e\n\u003cdiv class=\"r-faqs--faq-answer j-faqs--answer open\"\u003e\n\u003cp\u003eIn a modified sine wave, the voltage rises and falls abruptly, the phase angle also changes abruptly and it sits at 0 Volts for some time before changing its polarity.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cspan class=\"r-faqs--faq-toggle s-read-more j-faqs--toggle\"\u003e\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"r-faqs--faq j-faqs--single\"\u003e\n\u003ch5 class=\"r-faqs--faq-question j-faqs--question\"\u003eWhat are the advantages of Pure Sine Wave inverters?\u003c\/h5\u003e\n\u003cdiv class=\"r-faqs--faq-answer j-faqs--answer open\"\u003e\n\u003cul\u003e\n\u003cli\u003eThe output wave-form is a sine-wave with\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003every low harmonic distortion\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand clean power like utility supplied electricity\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eInductive loads\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003elike microwaves and motors run faster, quieter and cooler\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eReduces audible and electrical noise\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ein fans, fluorescent lights, audio amplifiers, TV, fax and answering machines\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePrevents crashes\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ein computers, weird print outs and glitches in monitors\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"o-resource-body\"\u003e\n\u003cdiv class=\"r-faqs j-faqs\"\u003e\n\u003cdiv class=\"r-faqs--container\"\u003e\n\u003cdiv class=\"r-faqs--faqs j-faqs--faqs\"\u003e\n\u003cdiv class=\"r-faqs--faq j-faqs--single\" id=\"Which-devices-will-not-function-properly-from-a-Modified-Sine-Wave-Inverter\"\u003e\n\u003ch5 class=\"r-faqs--faq-question j-faqs--question\"\u003eWhich devices will not function properly from a Modified Sine Wave Inverter?\u003c\/h5\u003e\n\u003cdiv class=\"r-faqs--faq-answer j-faqs--answer open\"\u003e\n\u003cp\u003eAny device that uses a control circuitry that senses the phase (for voltage \/ speed control) or instantaneous zero voltage crossing (for timing control) will not work properly from a voltage that has a modified sine wave-form. Also, as the modified sine wave is a form of square wave, it is comprised of multiple sine waves of odd harmonics (multiples) of the fundamental frequency of the modified sine wave. For example, a 60 Hz. modified sine wave will consist of sine waves with odd harmonic frequencies of 3rd (180 Hz), 5th (300 Hz.), 7th (420 Hz.) and so on. The high frequency harmonic content in a modified sine wave produces enhanced radio interference, higher heating effect in motors \/ microwaves and produces overloading due to lowering of the impedance of low frequency filter capacitors \/ power factor improvement capacitors.\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eSome examples of devices that may not work properly with modified sine wave and may also get damaged are given below\u003c\/em\u003e\u003c\/p\u003e\n\u003cul type=\"circle\"\u003e\n\u003cli\u003eLaser printers, photocopiers, magneto-optical hard drives\u003c\/li\u003e\n\u003cli\u003eThe built-in clocks in devices such as clock radios, alarm clocks, coffee makers, bread-makers, VCR, microwave ovens etc may not keep time correctly\u003c\/li\u003e\n\u003cli\u003eOutput voltage control devices like dimmers, ceiling fan \/ motor speed control may not work properly (dimming \/ speed control may not function)\u003c\/li\u003e\n\u003cli\u003eSewing machines with speed \/ microprocessor control\u003c\/li\u003e\n\u003cli\u003eTransformer-less capacitive input powered devices like (i) Razors, flashlights, night-lights, smoke detectors etc (ii) Re-chargers for battery packs used in hand power tools.\u003cspan\u003e \u003c\/span\u003e\u003cem\u003eThese may get damaged. Please check with the manufacturer of these types of devices for suitability\u003c\/em\u003e\n\u003c\/li\u003e\n\u003cli\u003eDevices that use radio frequency signals carried by the AC distribution wiring\u003c\/li\u003e\n\u003cli\u003eSome new furnaces with microprocessor control \/ Oil burner primary controls\u003c\/li\u003e\n\u003cli\u003eHigh intensity discharge (HID) lamps like Metal Halide lamps.\u003cspan\u003e \u003c\/span\u003e\u003cem\u003eThese may get damaged. Please check with the manufacturer of these types of devices for suitability\u003c\/em\u003e\n\u003c\/li\u003e\n\u003cli\u003eSome fluorescent lamps \/ light fixtures that have power factor correction capacitors.\u003cspan\u003e \u003c\/span\u003e\u003cem\u003eThe inverter may shut down indicating overload\u003c\/em\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5 class=\"r-faqs--faq-question j-faqs--question\"\u003eWhat is a DC-AC inverter?\u003c\/h5\u003e\n\u003cp\u003eWhen you plug anything into the wall in your home you are usually “plugging in” to the power-grid provided as a service by your utility company. Your utility company supplies you with alternating current (AC) electricity. AC electricity flows in alternate directions many times per second. AC is used for utility grid service because it is more practical for long distance transmission.\u003c\/p\u003e\n\u003cp\u003eBatteries provide direct current electricity (DC) electricity which flows in a single direction.  DC power is what is used in many electronics in the home like laptops, solar cells, LED bulbs, and electric vehicles.  They usually have built-in converters to take the AC power received from a plug-in and convert it to DC.\u003c\/p\u003e\n\u003cp\u003eAn inverter (converter) acts as a power adapter as it converts DC to AC,  AC to DC, and can also change the voltage. It allows a battery-based system to run conventional AC appliances directly or through conventional home wiring.\u003c\/p\u003e\n\u003ch5 class=\"r-faqs--faq-question j-faqs--question\"\u003eWhat are the criteria for selecting the right inverter for a particular application?\u003c\/h5\u003e\n\u003cdiv id=\"What-are-the-criteria-for-selecting-the-right-inverter-for-a-particular-application\" class=\"r-faqs--faq j-faqs--single\"\u003e\n\u003cdiv class=\"r-faqs--faq-answer j-faqs--answer open\"\u003e\n\u003cp\u003eTo choose an inverter; you should first define your needs. Where is the inverter to be used? Inverters are available for use in buildings (including homes), for recreational vehicles, boats, and portable applications. Will it be connected to the utility grid in some way? Electrical conventions and safety standards differ for various applications, so don’t improvise.\u003c\/p\u003e\n\u003cp\u003eWhen sizing an inverter, you need to take into consideration both the\u003cstrong\u003e\u003cem\u003e\u003cspan\u003e \u003c\/span\u003erunning power\u003c\/em\u003e\u003c\/strong\u003e \u003cspan\u003e \u003c\/span\u003e\u003cem\u003e\u003cstrong\u003e(continuous)\u003c\/strong\u003e\u003c\/em\u003e\u003cspan\u003e \u003c\/span\u003eand the additional\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e\u003cem\u003estarting surge power\u003c\/em\u003e\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003erequirements of the AC side loads.\u003c\/p\u003e\n\u003cp\u003eSome loads require much higher starting surge power for the first few seconds before settling down at the running power. The inverter should be sized on the basis of the starting surge power of the AC side load. The total starting surge power is equal to the normal running power plus the additional starting power. The following symbols and equation will be used for explanation purposes:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eRunning Power, Watts – \u003cstrong\u003eWr\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eAdditional Starting Power or Additional Continuous Power, Watts – \u003cstrong\u003eWa\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eTotal Starting Surge Power, Watts = Running Power (\u003cstrong\u003eWr\u003c\/strong\u003e) + Additional Starting Power \/ Additional Continuous Power (\u003cstrong\u003eWa\u003c\/strong\u003e)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe specifications of inverters may include a rating termed Surge Power. Normally, the duration of this Surge Power rating is not quantified in the specifications and is assumed to last for less than 1 second. Unless the Surge Power Rating of the inverter is specified to last for \u0026gt; 5 seconds, this Surge Power specification of the inverter should not be considered for purposes of sizing loads with high and prolonged starting surge power.\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eOnly the Continuous Power rating of the inverter should be considered in such cases\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eElectric motor driven compressor\/pump based loads like refrigerators\/freezers, air conditioners, air compressors, sump and well pumps, etc. require a very high Starting Surge Power of around 5 to 7 times the Running Power for the initial start up. This Starting Surge Power may last for 2 to 5 seconds.  The Additional Starting Power\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eWa\u003c\/strong\u003e should be taken as 4 times the Running Power \u003cstrong\u003eWr\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eSwitched Mode Power Supplies (SMPS) that do not have Power Factor correction draw a non linear, pulsing current with a high Crest Factor (Ratio of instantaneous value and the RMS value) that may reach a value of 4. Also, the effective Power Factor of these types of power supplies is very low around 0.6. If the inverter is sized based on the Running Power of these units, the inverter will be continuously overloaded from instant to instant due to the higher peaks of the pulsing current. The inverter for these units should be sized at 3 times the Running Power of the power supply. Alternatively, for sizing purposes, the Additional Continuous Power \u003cstrong\u003eWa\u003c\/strong\u003e should be taken as 2 times the Running Power \u003cstrong\u003eWr\u003c\/strong\u003e. Consumer electronics like computers, TV, VCR, audio\/ video devices, etc. use this type of power supply.\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e(Please note that this sizing is not applicable if the SMPS has Power Factor correction and the Power Factor is around 0.9)\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eMotors used in washing machines have to start under load due to the weight of the clothes, water and the drum. Hence, the Additional Starting Power \u003cstrong\u003eWa\u003c\/strong\u003e should be taken as 2 times the Running Power \u003cstrong\u003eWr\u003c\/strong\u003e. This starting power normally lasts from 2 to 5 seconds.\u003c\/p\u003e\n\u003cp\u003eThe Watt rating of the microwaves normally indicates output cooking power in Watts. As the microwave is not an efficient device, the AC input power in Watts should be taken as 2 times the output cooking power in Watts i.e. the Additional Continuous Power \u003cstrong\u003eWa\u003c\/strong\u003e should be taken as 1 time the Running Power \u003cstrong\u003eWr\u003c\/strong\u003e. Hence, a microwave with 900 Watt cooking power will require an 1800 Watt inverter. \u003cstrong\u003e(If the power rating of the inverter is indicated as the AC input power in Watts, the factor of 2 is not applicable).\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe following symbols and equations are used in the sizing of an inverter example below:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTotal Running Power of the items selected, Watts – \u003cstrong\u003eWrt\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eHighest Additional Starting Power out of the items selected, Watts – \u003cstrong\u003eWah\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e*Highest power for sizing purpose, Watts – \u003cstrong\u003eWrt + Wah\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003e* It is assumed that only one out of the selected items starts at one time\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003eSince the AC loads rarely start at the same time, the load with the highest Additional Starting Power \u003cstrong\u003eWah\u003c\/strong\u003e has been factored in.\u003c\/p\u003e\n\u003cp\u003eExample:\u003cbr\u003e\u003c\/p\u003e\n\u003ctable class=\"tablepress tablepress-id-15 tablepress-responsive\" id=\"tablepress-15\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"row-1 odd\"\u003e\n\u003cth class=\"column-1\"\u003e\n\u003cp\u003e\u003csmall\u003eDevice \/ Appliance\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/th\u003e\n\u003cth class=\"column-2\"\u003e\n\u003cp\u003e\u003csmall\u003eRunning Power, Wr, Watts\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/th\u003e\n\u003cth class=\"column-3\"\u003e\n\u003cp\u003e\u003csmall\u003eAdditional\u003cbr\u003eStarting Power or Additional Continuous Power *, Wa, Watts\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/th\u003e\n\u003cth class=\"column-4\"\u003e\n\u003cp\u003e\u003csmall\u003eQuantity\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/th\u003e\n\u003cth class=\"column-5\"\u003e\n\u003cp\u003e\u003csmall\u003eExtended\u003cbr\u003eRunning Power, Wt, Watts\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody class=\"row-hover\"\u003e\n\u003ctr class=\"row-2 even\"\u003e\n\u003ctd class=\"column-1\"\u003e\n\u003cp\u003e\u003csmall\u003eRefrigerator – Electric Compressor based\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"column-2\"\u003e\n\u003cp\u003e\u003csmall\u003e200\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"column-3\"\u003e\n\u003cp\u003e\u003csmall\u003e800\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"column-4\"\u003e\n\u003cp\u003e\u003csmall\u003e1\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"column-5\"\u003e\n\u003cp\u003e\u003csmall\u003e200\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"row-3 odd\"\u003e\n\u003ctd class=\"column-1\"\u003e\n\u003cp\u003e\u003csmall\u003eColor TV\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"column-2\"\u003e\n\u003cp\u003e\u003csmall\u003e225\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"column-3\"\u003e\n\u003cp\u003e\u003csmall\u003e450\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"column-4\"\u003e\n\u003cp\u003e\u003csmall\u003e1\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"column-5\"\u003e\n\u003cp\u003e\u003csmall\u003e225\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"row-4 even\"\u003e\n\u003ctd class=\"column-1\"\u003e\n\u003cp\u003e\u003csmall\u003eLaptop Adapter\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"column-2\"\u003e\n\u003cp\u003e\u003csmall\u003e120\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"column-3\"\u003e\n\u003cp\u003e\u003csmall\u003e240\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"column-4\"\u003e\n\u003cp\u003e\u003csmall\u003e1\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"column-5\"\u003e\n\u003cp\u003e\u003csmall\u003e120\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"row-5 odd\"\u003e\n\u003ctd class=\"column-1\"\u003e\n\u003cp\u003e\u003csmall\u003eIncandescent Lamps\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"column-2\"\u003e\n\u003cp\u003e\u003csmall\u003e60\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"column-3\"\u003e\n\u003cp\u003e\u003csmall\u003e0\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"column-4\"\u003e\n\u003cp\u003e\u003csmall\u003e6\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"column-5\"\u003e\n\u003cp\u003e\u003csmall\u003e360\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e*\u003c\/strong\u003e \u003cem\u003eAdditional Continuous Power is applicable to SMPS based loads that have no Power Factor Correction.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003eTotal Extended Running Power, \u003cstrong\u003eWrt\u003c\/strong\u003e = 200 + 225 + 120 + 360 = \u003cstrong\u003e905\u003c\/strong\u003e Watts\u003c\/p\u003e\n\u003cp\u003eHighest Additional Starting Power, \u003cstrong\u003eWah\u003c\/strong\u003e = \u003cstrong\u003e800\u003c\/strong\u003e Watts\u003c\/p\u003e\n\u003cp\u003eHighest Power for sizing the inverter = Total Running Power, \u003cstrong\u003eWrt\u003c\/strong\u003e(905 W) + Highest Additional Starting Power, \u003cstrong\u003eWah\u003c\/strong\u003e (800 W) = \u003cstrong\u003e1705\u003c\/strong\u003e Watts\u003c\/p\u003e\n\u003ch5 class=\"r-faqs--faq-question j-faqs--question\"\u003eWhat are the electrical standards pertaining to DC-AC inverters?\u003c\/h5\u003e\n\u003cdiv class=\"r-faqs--faq-answer j-faqs--answer open\"\u003e\n\u003cmeta charset=\"utf-8\"\u003e\n\u003cp\u003eThe DC input voltage must conform to that of the electrical system and battery bank. 12 volts is recommended for small, simple systems. 24 and 48 volts are the common standards for higher capacities. A higher voltage system carries less current, which makes the system wiring cheaper and easier.\u003c\/p\u003e\n\u003cp\u003eThe inverter’s AC output must conform to the conventional power in the region to run locally available appliances. The standard for AC utility service in North America is 120 and 240 Volts at a frequency of 60 Hertz (cycles per second). In Europe, South America, and most other places, it is 230 volts at 50 Hertz.\u003c\/p\u003e\n\u003ch5 class=\"r-faqs--faq-question j-faqs--question\"\u003eWhat are \"continuous\" and \"surge\" power capacity ratings for DC-AC inverters?\u003c\/h5\u003e\n\u003cdiv id=\"What-are-continuous-and-surge-power-capacity-ratings-for-DC-AC-inverters\" class=\"r-faqs--faq j-faqs--single\"\u003e\n\u003cdiv class=\"r-faqs--faq-answer j-faqs--answer open\"\u003e\n\u003cp\u003eHow much load can an inverter handle? Its power output is rated in Watts.  There are two levels of power rating -a continuous rating and a surge rating. Continuous means the amount of power the inverter can handle for an indefinite period of hours. When an inverter is rated at a certain number of Watts, that number generally refers to its continuous rating. The “surge power” indicates the power to handle instantaneous overload of a few seconds to provide the higher power required to start certain type of devices and appliances.  Resistive types of loads (like incandescent lamps, toaster, coffee maker, electric range, iron etc) do not require extra power to start. Their starting power is the same as their running power.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cspan class=\"r-faqs--faq-toggle s-read-more j-faqs--toggle\"\u003e\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"r-faqs--faq j-faqs--single\"\u003e\n\u003ch5 class=\"r-faqs--faq-question j-faqs--question\"\u003eHow do \"surge power\" electrical loads affect DC-AC inverter operation?\u003c\/h5\u003e\n\u003cp\u003eIf an inverter cannot efficiently feed the surge power, it may simply shut down instead of starting the device. If the inverter’s surge capacity is marginal, its output voltage will dip during the surge. This can cause a dimming of the lights in the house, and will sometimes crash a computer.\u003c\/p\u003e\n\u003cp\u003eAny weakness in the battery and cabling to the inverter will further limit its ability to start a motor. A battery bank that is undersized, in poor condition, or has corroded connections, can be a weak link in the power chain. The inverter cables and the battery interconnect cables must be sized properly. The spike of DC current through these cables is many hundreds of amps at the instant of a motor starting for example.\u003c\/p\u003e\n\u003ch5 class=\"r-faqs--faq-question j-faqs--question\"\u003eHow should I size my DC-AC inverter for loads that require starting surge?\u003c\/h5\u003e\n\u003cdiv id=\"How-should-I-size-my-DC-AC-inverter-for-loads-that-require-starting-surge\" class=\"r-faqs--faq j-faqs--single\"\u003e\n\u003cdiv class=\"r-faqs--faq-answer j-faqs--answer open\"\u003e\n\u003cp\u003eObserve the following guideline to determine the continuous wattage of the inverter for powering loads that require starting surge. (Multiply the running watts of the device\/appliance by the Surge Factor)\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003e\u003cstrong\u003eNOTE:\u003c\/strong\u003e The surge power rating specified for this inverter is valid for duration of less than 1 second. This very short duration may not be sufficient to start motor based loads which may require up to 5 seconds to complete starting process. Hence, for purposes of sizing the inverter, use only the continuous power rating of this inverter.\u003c\/em\u003e\u003c\/p\u003e\n\u003ctable class=\"tablepress tablepress-id-16 tablepress-responsive\" id=\"tablepress-16\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"row-1 odd\"\u003e\n\u003cth class=\"column-1\"\u003e\n\u003cp\u003e\u003csmall\u003eDevice \/ Appliance\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/th\u003e\n\u003cth class=\"column-2\"\u003e\n\u003cp\u003e\u003csmall\u003eSurge Factor\u003cbr\u003e(No. of times the running power rating of the device\/appliance)\u003c\/small\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody class=\"row-hover\"\u003e\n\u003ctr class=\"row-2 even\"\u003e\n\u003ctd class=\"column-1\"\u003e\n\u003cp\u003e\u003csmall\u003eRefrigerator \/ Freezer\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"column-2\"\u003e\n\u003cp\u003e\u003csmall\u003e5\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"row-3 odd\"\u003e\n\u003ctd class=\"column-1\"\u003e\n\u003cp\u003e\u003csmall\u003eAir Compressors\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"column-2\"\u003e\n\u003cp\u003e\u003csmall\u003e4\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"row-4 even\"\u003e\n\u003ctd class=\"column-1\"\u003e\n\u003cp\u003e\u003csmall\u003eDishwasher\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"column-2\"\u003e\n\u003cp\u003e\u003csmall\u003e3\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"row-5 odd\"\u003e\n\u003ctd class=\"column-1\"\u003e\n\u003cp\u003e\u003csmall\u003eSump pump\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"column-2\"\u003e\n\u003cp\u003e\u003csmall\u003e3\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"row-6 even\"\u003e\n\u003ctd class=\"column-1\"\u003e\n\u003cp\u003e\u003csmall\u003eFurnace fans\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"column-2\"\u003e\n\u003cp\u003e\u003csmall\u003e3\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"row-7 odd\"\u003e\n\u003ctd class=\"column-1\"\u003e\n\u003cp\u003e\u003csmall\u003eIndustrial motors\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"column-2\"\u003e\n\u003cp\u003e\u003csmall\u003e3\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"row-8 even\"\u003e\n\u003ctd class=\"column-1\"\u003e\n\u003cp\u003e\u003csmall\u003eCircular saw\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"column-2\"\u003e\n\u003cp\u003e\u003csmall\u003e3\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"row-9 odd\"\u003e\n\u003ctd class=\"column-1\"\u003e\n\u003cp\u003e\u003csmall\u003eBench Grinder\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"column-2\"\u003e\n\u003cp\u003e\u003csmall\u003e3\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"row-10 even\"\u003e\n\u003ctd class=\"column-1\"\u003e\n\u003cp\u003e\u003csmall\u003ePortable diesel \/ kerosene fuel heater\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"column-2\"\u003e\n\u003cp\u003e\u003csmall\u003e2\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cspan class=\"r-faqs--faq-toggle s-read-more j-faqs--toggle\"\u003e\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"r-faqs--faq j-faqs--single\"\u003e\n\u003cdiv id=\"How-should-I-size-my-DC-AC-inverter-to-operate-a-microwave\" class=\"r-faqs--faq j-faqs--single\"\u003e\n\u003ch5 class=\"r-faqs--faq-question j-faqs--question\"\u003eHow should I size my DC-AC inverter to operate a microwave?\u003c\/h5\u003e\n\u003cspan class=\"r-faqs--faq-toggle s-read-more j-faqs--toggle\"\u003e\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"r-faqs--faq j-faqs--single\"\u003e\n\u003cdiv id=\"How-should-I-size-my-DC-AC-inverter-to-operate-a-microwave\" class=\"r-faqs--faq j-faqs--single\"\u003e\n\u003cdiv class=\"r-faqs--faq-answer j-faqs--answer open\"\u003e\n\u003cp\u003eThe power rating of the microwave generally refers to the cooking power. The electrical power consumed by the microwave will be approximately 2 times the cooking power. The “surge power” of the inverter should be 2 times the electrical power (i.e., 4 times the cooking power). Please note that the surge power of the microwave is not as long as the motor load and hence, the surge power of the inverter can be considered to determine adequacy of meeting the starting surge power.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cspan class=\"r-faqs--faq-toggle s-read-more j-faqs--toggle\"\u003e\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"r-faqs--faq j-faqs--single\"\u003e\n\u003ch5 class=\"r-faqs--faq-question j-faqs--question\"\u003eHow should I size my DC-AC inverter to power a water supply pump?\u003c\/h5\u003e\n\u003cp\u003eA water well or pressure pump often places the greatest demand on the inverter. It warrants special consideration. Most pumps draw a very high surge of current during start up. The inverter must have sufficient surge capacity to handle it while running any other loads that may be on. It is important to size an inverter sufficiently, especially to handle the starting surge (If the exact starting rating is not available, the starting surge can be taken as 3 times the normal running rating of the pump). Oversize it still further if you want it to start the pump without causing lights to dim or blink.\u003c\/p\u003e\n\u003cp\u003eIn North America, most pumps (especially submersibles) run on 240 VAC, while smaller appliances and lights use 120 VAC. To obtain 240 VAC from a 120 VAC inverter, use a 120 VAC to 240 VAC transformer. If you do not already have a pump installed, you can get a 120 volt pump if you don’t need more than 1\/2 HP.\u003c\/p\u003e\n\u003ch5 class=\"r-faqs--faq-question j-faqs--question\"\u003eWhat is \"idle power\" in a DC-AC inverter?\u003c\/h5\u003e\n\u003cdiv id=\"What-is-idle-power-in-a-DC-AC-inverter\" class=\"r-faqs--faq j-faqs--single\"\u003e\n\u003cdiv class=\"r-faqs--faq-answer j-faqs--answer open\"\u003e\n\u003cp\u003eIdle power is the consumption of the inverter when it is on, but no loads are running. It is “wasted” power, so if you expect the inverter to be on for many hours during which there is very little load (as in most residential situations), you want this to be as low as possible.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cspan class=\"r-faqs--faq-toggle s-read-more j-faqs--toggle\"\u003e\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"r-faqs--faq j-faqs--single\"\u003e\n\u003ch5 class=\"r-faqs--faq-question j-faqs--question\"\u003eWhat are Phantom and idling loads?\u003c\/h5\u003e\n\u003cp\u003eMost of the modern gadgets draw some power whenever they are plugged in. Some of them use power to do nothing at all. An example is a TV with a remote control. Its electric eye system is on day and night, watching for your signal to turn the screen on. Every appliance with an external wall-plug transformer uses power even when the appliance is turned off. These little loads are called “phantom loads” because their power draw is unexpected, unseen, and easily forgotten.\u003c\/p\u003e\n\u003cp\u003eA similar concern is “idling loads.” These are devices that must be on all the time in order to function when needed. These include smoke detectors, alarm systems, motion detector lights, fax machines, and answering machines. Central heating systems have a transformer in their thermostat circuit that stays on all the time. Cordless (rechargeable) appliances draw power even after their batteries reach a full charge. If in doubt, feel the device. If it’s warm, that indicates wasted energy.\u003c\/p\u003e\n\u003ch5 class=\"r-faqs--faq-question j-faqs--question\"\u003eCan a standard DC-AC inverter be connected in parallel with another AC source\/ DC-AC inverter \/ electrical utility?\u003c\/h5\u003e\n\u003cdiv id=\"Can-a-standard-DC-AC-inverter-be-connected-in-parallel-with-another-AC-source-DC-AC-inverter-electrical-utility\" class=\"r-faqs--faq j-faqs--single\"\u003e\n\u003cdiv class=\"r-faqs--faq-answer j-faqs--answer open\"\u003e\n\u003cp\u003eThe AC output of standard inverters cannot be synchronised with another AC source and hence, it is not suitable for paralleling. The AC output of the inverter should never be connected directly to an electrical breaker panel \/ load center which is also fed from the utility power \/generator. Such a connection may result in parallel operation of the different power sources and AC power from the utility \/ generator will be fed back into the inverter which will instantly damage the output section of the inverter and may also pose a fire and safety hazard.\u003c\/p\u003e\n\u003cp\u003eIf an electrical breaker panel \/ load center is fed from an inverter and this panel is also required to be powered from additional alternate AC sources, the AC power from all the AC sources like the utility \/ generator \/ inverter should first be fed to a manual selector switch and the output of the selector switch should be connected to the electrical breaker panel \/ load center. To prevent possibility of paralleling and severe damage to the inverter, never use a simple jumper cable with a male plug on both ends to connect the AC output of the inverter to a handy wall receptacle in the home\/RV.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cspan class=\"r-faqs--faq-toggle s-read-more j-faqs--toggle\"\u003e\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"r-faqs--faq j-faqs--single\"\u003e\n\u003ch5 class=\"r-faqs--faq-question j-faqs--question\"\u003eHow can DC-AC inverters be connected to multi-wire branch circuits?\u003c\/h5\u003e\n\u003cdiv id=\"How-can-DC-AC-inverters-be-connected-to-multi-wire-branch-circuits\" class=\"r-faqs--faq j-faqs--single\"\u003e\n\u003cdiv class=\"r-faqs--faq-answer j-faqs--answer open\"\u003e\n\u003cp\u003eDo not directly connect the hot side of the inverter to the two hot legs of the 120 \/ 240 VAC electrical breaker panel \/ load centre where multi-wire ( common neutral ) branch circuit wiring method is used for distribution of AC power. This may lead to overloading\/overheating of the neutral conductor and is a risk of fire.\u003c\/p\u003e\n\u003cp\u003eA split phase transformer (isolated or auto-transformer ) of suitable wattage rating ( 25% more than the wattage rating of the inverter ) with primary of 120 VAC and secondary of 120 \/ 240 VAC ( Two 120 VAC split phases 180 degrees apart) should be used. The hot and neutral of the 120 VAC output of the inverter should be fed to the primary of this transformer and the 2 hot outputs (120 VAC split phases ) and the neutral from the secondary of this transformer should be connected to the electrical breaker panel\/ load centre.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cspan class=\"r-faqs--faq-toggle s-read-more j-faqs--toggle\"\u003e\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv id=\"How-should-I-size-my-DC-AC-inverter-to-supply-computer-or-printer-loads\" class=\"r-faqs--faq j-faqs--single\"\u003e\n\u003ch5 class=\"r-faqs--faq-question j-faqs--question\"\u003eHow should I size my DC-AC inverter to supply computer or printer loads?\u003c\/h5\u003e\n\u003cdiv id=\"How-should-I-size-my-DC-AC-inverter-to-supply-computer-or-printer-loads\" class=\"r-faqs--faq j-faqs--single\"\u003e\n\u003cdiv class=\"r-faqs--faq-answer j-faqs--answer open\"\u003e\n\u003cp\u003eComputers and Printers generally come with in-built switch-mode power supplies (see \u003ca href=\"https:\/\/samlexamerica.com\/resources-support\/application-notes\/\"\u003eapplication notes\u003c\/a\u003e and \u003ca href=\"https:\/\/samlexamerica.com\/resources-support\/faq\/inverters-powering-direct-embedded-smps\/\"\u003eFAQs on switch mode power supplies (SMPS)\u003c\/a\u003e) that have extremely low power factor on account of the extremely peaky and non-linear nature of the current drawn by them from the AC source. Hence for such loads we recommend using inverters with three times the advertised power consumption of the computer or printer loads.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cspan class=\"r-faqs--faq-toggle s-read-more j-faqs--toggle\"\u003e\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"r-faqs--faq j-faqs--single\"\u003e\n\u003ch5 class=\"r-faqs--faq-question j-faqs--question\"\u003eWhat is the difference between a 12V, 24V and 48V inverter?\u003c\/h5\u003e\n\u003cdiv class=\"o-resource-body\"\u003e\n\u003cdiv class=\"r-faqs j-faqs\"\u003e\n\u003cdiv class=\"r-faqs--container\"\u003e\n\u003cdiv class=\"r-faqs--faqs j-faqs--faqs\"\u003e\n\u003cdiv id=\"What-is-the-difference-between-a-12V-24V-and-48V-inverter\" class=\"r-faqs--faq j-faqs--single\"\u003e\n\u003cdiv class=\"r-faqs--faq-answer j-faqs--answer open\"\u003e\n\u003cp\u003eA 12-V can be fed from a 12V battery or DC supply. Similarly 24V and 48V inverters can be fed from 24V and 48V batteries\/DC power supplies, respectively. Cars usually have 12V batteries. Trucks have 24V batteries.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Samlex America","offers":[{"title":"Default Title","offer_id":50359596351771,"sku":"OGL-67249","price":173.7,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0724\/2026\/2171\/files\/67249XL.jpg?v=1749567217"},{"product_id":"samlex-100w-fully-isolated-dc-dc-converter-8a-9-18v-input-12-5v-output-idc-100a-12","title":"Samlex 100W Fully Isolated DC-DC Converter - 8A - 9-18V Input - 12.5V Output [IDC-100A-12]","description":"\u003ch2\u003e\u003cspan style=\"text-decoration: underline;\"\u003eSamlex 100W Fully Isolated DC-DC Converter - 8A - 9-18V Input - 12.5V Output [IDC-100A-12]\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003eIDC-100 series is a complete line of high efficiency 100 Watt isolated DC-DC converters suitable for applications requiring galvanic isolation between the input and the output. IDC-100A-12 isolated DC-DC converter provides a highly regulated output DC voltage of 12.5 Volts for an input DC voltage range of 9-18 Volts and rated output current of 8 Amps (at 18 Volts input). Features of this isolated DC-DC converter include compact housing, fold-back current limiting and protection against short circuit, overheating, overvoltage and reverse polarity connection. The unit comes with 1\/4” push-on flat blade “quick disconnect” connectors. IDC-100A-12 isolated DC-DC converter is EMI\/EMC compliant and conforms to European standards EN50081-1 (for EMI), EN50082-1 (for EMC) and the European Automotive Directive 95\/54\/CE.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eFully Isolated\u003c\/li\u003e\n\u003cli\u003eShort Circuit Protected\u003c\/li\u003e\n\u003cli\u003eCurrent Limited\u003c\/li\u003e\n\u003cli\u003e2 Year Warranty\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\n\u003cmeta charset=\"utf-8\"\u003eProduct Specifications\u003c\/h3\u003e\n\u003ch2\u003e\u003cspan style=\"text-decoration: underline;\"\u003eSamlex 100W Fully Isolated DC-DC Converter - 8A - 9-18V Input - 12.5V Output [IDC-100A-12] Product Specifications\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eInput: 9.2-18 VDC\u003c\/li\u003e\n\u003cli\u003eOutput: 12.5 VDC\u003c\/li\u003e\n\u003cli\u003eAmps: 8 Amps\u003c\/li\u003e\n\u003cli\u003eWeight: 1.2 (lbs)\u003c\/li\u003e\n\u003cli\u003eWeight: 0.54 (kg)\u003c\/li\u003e\n\u003cli\u003eDimensions: 6 x 3.5 x 1.9 (in)\u003c\/li\u003e\n\u003cli\u003eDimensions: 15.2 x 8.9 x 4.8 (cm)\u003c\/li\u003e\n\u003cli\u003eSafety: CE\u003c\/li\u003e\n\u003cli\u003eWarranty: 2 Year Limited\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eEarth moving equipment\u003c\/li\u003e\n\u003cli\u003eHeavy trucks\u003c\/li\u003e\n\u003cli\u003eBuses\u003c\/li\u003e\n\u003cli\u003eMarine vehicles\u003c\/li\u003e\n\u003cli\u003eCB radios\u003c\/li\u003e\n\u003cli\u003e12 Volt lighting systems\u003c\/li\u003e\n\u003cli\u003eAM\/FM sound systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cimg alt=\"Warning\" src=\"https:\/\/productimageserver.com\/prop65\/6pt.png\"\u003e\u003cstrong\u003eWARNING:\u003c\/strong\u003e This product can expose you to chemicals which are known to the State of California to cause cancer, birth defects or other reproductive harm. For more information go to \u003ca href=\"http:\/\/P65Warnings.ca.gov\"\u003eP65Warnings.ca.gov\u003c\/a\u003e.\u003c\/p\u003e\n\u003c!--- cis2:m2lsnZdp ---\u003e\n\u003ch3\u003e\u003cspan\u003eProduct Manual\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/productimageserver.com\/literature\/ownersManual\/67251OM.pdf\" target=\"_blank\"\u003eOwner's Manual (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/productimageserver.com\/literature\/brochure\/67251BR.pdf\" target=\"_blank\"\u003eBrochure (pdf)\u003c\/a\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eProduct Warranty\u003c\/span\u003e\u003c\/h3\u003e\n\u003ch2 class=\"o-product--description\"\u003e3 Years Limited Warranty\u003c\/h2\u003e\n\u003ch3 class=\"o-product--description\"\u003eProduct FAQs\u003c\/h3\u003e\n\u003ch5 class=\"o-product--description\"\u003eWhat is a Pure Sine Wave Inverter?\u003c\/h5\u003e\n\u003cdiv class=\"o-product--description\"\u003eThe output voltage of a sine wave inverter has a sine wave form like the sine wave form of the mains \/ utility voltage. In a sine wave, the voltage rises and falls smoothly with a smoothly changing phase angle and also changes its polarity instantly when it crosses 0 Volts.\n\u003cdiv class=\"r-faqs--faq-answer j-faqs--answer open\"\u003e\n\u003cdiv id=\"What-are-the-advantages-of-Pure-Sine-Wave-inverters\" class=\"r-faqs--faq j-faqs--single\"\u003e\n\u003ch5 class=\"r-faqs--faq-question j-faqs--question\"\u003eWhat are the advantages of Pure Sine Wave inverters?\u003c\/h5\u003e\n\u003cdiv class=\"r-faqs--faq-answer j-faqs--answer open\"\u003e\n\u003cul\u003e\n\u003cli\u003eThe output wave-form is a sine-wave with\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003every low harmonic distortion\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand clean power like utility supplied electricity\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eInductive loads\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003elike microwaves and motors run faster, quieter and cooler\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eReduces audible and electrical noise\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ein fans, fluorescent lights, audio amplifiers, TV, fax and answering machines\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePrevents crashes\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ein computers, weird print outs and glitches in monitors\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cspan class=\"r-faqs--faq-toggle s-read-more j-faqs--toggle\"\u003e\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"r-faqs--faq j-faqs--single\"\u003e\n\u003cdiv id=\"What-is-a-Modified-Sine-Wave-Inverter\" class=\"r-faqs--faq j-faqs--single\"\u003e\n\u003ch5 class=\"r-faqs--faq-question j-faqs--question\"\u003eWhat is a Modified Sine Wave Inverter?\u003c\/h5\u003e\n\u003cdiv class=\"r-faqs--faq-answer j-faqs--answer open\"\u003e\n\u003cp\u003eIn a modified sine wave, the voltage rises and falls abruptly, the phase angle also changes abruptly and it sits at 0 Volts for some time before changing its polarity.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cspan class=\"r-faqs--faq-toggle s-read-more j-faqs--toggle\"\u003e\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"r-faqs--faq j-faqs--single\"\u003e\n\u003ch5 class=\"r-faqs--faq-question j-faqs--question\"\u003eWhat are the advantages of Pure Sine Wave inverters?\u003c\/h5\u003e\n\u003cdiv class=\"r-faqs--faq-answer j-faqs--answer open\"\u003e\n\u003cul\u003e\n\u003cli\u003eThe output wave-form is a sine-wave with\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003every low harmonic distortion\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand clean power like utility supplied electricity\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eInductive loads\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003elike microwaves and motors run faster, quieter and cooler\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eReduces audible and electrical noise\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ein fans, fluorescent lights, audio amplifiers, TV, fax and answering machines\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePrevents crashes\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ein computers, weird print outs and glitches in monitors\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"o-resource-body\"\u003e\n\u003cdiv class=\"r-faqs j-faqs\"\u003e\n\u003cdiv class=\"r-faqs--container\"\u003e\n\u003cdiv class=\"r-faqs--faqs j-faqs--faqs\"\u003e\n\u003cdiv id=\"Which-devices-will-not-function-properly-from-a-Modified-Sine-Wave-Inverter\" class=\"r-faqs--faq j-faqs--single\"\u003e\n\u003ch5 class=\"r-faqs--faq-question j-faqs--question\"\u003eWhich devices will not function properly from a Modified Sine Wave Inverter?\u003c\/h5\u003e\n\u003cdiv class=\"r-faqs--faq-answer j-faqs--answer open\"\u003e\n\u003cp\u003eAny device that uses a control circuitry that senses the phase (for voltage \/ speed control) or instantaneous zero voltage crossing (for timing control) will not work properly from a voltage that has a modified sine wave-form. Also, as the modified sine wave is a form of square wave, it is comprised of multiple sine waves of odd harmonics (multiples) of the fundamental frequency of the modified sine wave. For example, a 60 Hz. modified sine wave will consist of sine waves with odd harmonic frequencies of 3rd (180 Hz), 5th (300 Hz.), 7th (420 Hz.) and so on. The high frequency harmonic content in a modified sine wave produces enhanced radio interference, higher heating effect in motors \/ microwaves and produces overloading due to lowering of the impedance of low frequency filter capacitors \/ power factor improvement capacitors.\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eSome examples of devices that may not work properly with modified sine wave and may also get damaged are given below\u003c\/em\u003e\u003c\/p\u003e\n\u003cul type=\"circle\"\u003e\n\u003cli\u003eLaser printers, photocopiers, magneto-optical hard drives\u003c\/li\u003e\n\u003cli\u003eThe built-in clocks in devices such as clock radios, alarm clocks, coffee makers, bread-makers, VCR, microwave ovens etc may not keep time correctly\u003c\/li\u003e\n\u003cli\u003eOutput voltage control devices like dimmers, ceiling fan \/ motor speed control may not work properly (dimming \/ speed control may not function)\u003c\/li\u003e\n\u003cli\u003eSewing machines with speed \/ microprocessor control\u003c\/li\u003e\n\u003cli\u003eTransformer-less capacitive input powered devices like (i) Razors, flashlights, night-lights, smoke detectors etc (ii) Re-chargers for battery packs used in hand power tools.\u003cspan\u003e \u003c\/span\u003e\u003cem\u003eThese may get damaged. Please check with the manufacturer of these types of devices for suitability\u003c\/em\u003e\n\u003c\/li\u003e\n\u003cli\u003eDevices that use radio frequency signals carried by the AC distribution wiring\u003c\/li\u003e\n\u003cli\u003eSome new furnaces with microprocessor control \/ Oil burner primary controls\u003c\/li\u003e\n\u003cli\u003eHigh intensity discharge (HID) lamps like Metal Halide lamps.\u003cspan\u003e \u003c\/span\u003e\u003cem\u003eThese may get damaged. Please check with the manufacturer of these types of devices for suitability\u003c\/em\u003e\n\u003c\/li\u003e\n\u003cli\u003eSome fluorescent lamps \/ light fixtures that have power factor correction capacitors.\u003cspan\u003e \u003c\/span\u003e\u003cem\u003eThe inverter may shut down indicating overload\u003c\/em\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5 class=\"r-faqs--faq-question j-faqs--question\"\u003eWhat is a DC-AC inverter?\u003c\/h5\u003e\n\u003cp\u003eWhen you plug anything into the wall in your home you are usually “plugging in” to the power-grid provided as a service by your utility company. Your utility company supplies you with alternating current (AC) electricity. AC electricity flows in alternate directions many times per second. AC is used for utility grid service because it is more practical for long distance transmission.\u003c\/p\u003e\n\u003cp\u003eBatteries provide direct current electricity (DC) electricity which flows in a single direction.  DC power is what is used in many electronics in the home like laptops, solar cells, LED bulbs, and electric vehicles.  They usually have built-in converters to take the AC power received from a plug-in and convert it to DC.\u003c\/p\u003e\n\u003cp\u003eAn inverter (converter) acts as a power adapter as it converts DC to AC,  AC to DC, and can also change the voltage. It allows a battery-based system to run conventional AC appliances directly or through conventional home wiring.\u003c\/p\u003e\n\u003ch5 class=\"r-faqs--faq-question j-faqs--question\"\u003eWhat are the criteria for selecting the right inverter for a particular application?\u003c\/h5\u003e\n\u003cdiv class=\"r-faqs--faq j-faqs--single\" id=\"What-are-the-criteria-for-selecting-the-right-inverter-for-a-particular-application\"\u003e\n\u003cdiv class=\"r-faqs--faq-answer j-faqs--answer open\"\u003e\n\u003cp\u003eTo choose an inverter; you should first define your needs. Where is the inverter to be used? Inverters are available for use in buildings (including homes), for recreational vehicles, boats, and portable applications. Will it be connected to the utility grid in some way? Electrical conventions and safety standards differ for various applications, so don’t improvise.\u003c\/p\u003e\n\u003cp\u003eWhen sizing an inverter, you need to take into consideration both the\u003cstrong\u003e\u003cem\u003e\u003cspan\u003e \u003c\/span\u003erunning power\u003c\/em\u003e\u003c\/strong\u003e \u003cspan\u003e \u003c\/span\u003e\u003cem\u003e\u003cstrong\u003e(continuous)\u003c\/strong\u003e\u003c\/em\u003e\u003cspan\u003e \u003c\/span\u003eand the additional\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e\u003cem\u003estarting surge power\u003c\/em\u003e\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003erequirements of the AC side loads.\u003c\/p\u003e\n\u003cp\u003eSome loads require much higher starting surge power for the first few seconds before settling down at the running power. The inverter should be sized on the basis of the starting surge power of the AC side load. The total starting surge power is equal to the normal running power plus the additional starting power. The following symbols and equation will be used for explanation purposes:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eRunning Power, Watts – \u003cstrong\u003eWr\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eAdditional Starting Power or Additional Continuous Power, Watts – \u003cstrong\u003eWa\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eTotal Starting Surge Power, Watts = Running Power (\u003cstrong\u003eWr\u003c\/strong\u003e) + Additional Starting Power \/ Additional Continuous Power (\u003cstrong\u003eWa\u003c\/strong\u003e)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe specifications of inverters may include a rating termed Surge Power. Normally, the duration of this Surge Power rating is not quantified in the specifications and is assumed to last for less than 1 second. Unless the Surge Power Rating of the inverter is specified to last for \u0026gt; 5 seconds, this Surge Power specification of the inverter should not be considered for purposes of sizing loads with high and prolonged starting surge power.\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eOnly the Continuous Power rating of the inverter should be considered in such cases\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eElectric motor driven compressor\/pump based loads like refrigerators\/freezers, air conditioners, air compressors, sump and well pumps, etc. require a very high Starting Surge Power of around 5 to 7 times the Running Power for the initial start up. This Starting Surge Power may last for 2 to 5 seconds.  The Additional Starting Power\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eWa\u003c\/strong\u003e should be taken as 4 times the Running Power \u003cstrong\u003eWr\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eSwitched Mode Power Supplies (SMPS) that do not have Power Factor correction draw a non linear, pulsing current with a high Crest Factor (Ratio of instantaneous value and the RMS value) that may reach a value of 4. Also, the effective Power Factor of these types of power supplies is very low around 0.6. If the inverter is sized based on the Running Power of these units, the inverter will be continuously overloaded from instant to instant due to the higher peaks of the pulsing current. The inverter for these units should be sized at 3 times the Running Power of the power supply. Alternatively, for sizing purposes, the Additional Continuous Power \u003cstrong\u003eWa\u003c\/strong\u003e should be taken as 2 times the Running Power \u003cstrong\u003eWr\u003c\/strong\u003e. Consumer electronics like computers, TV, VCR, audio\/ video devices, etc. use this type of power supply.\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e(Please note that this sizing is not applicable if the SMPS has Power Factor correction and the Power Factor is around 0.9)\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eMotors used in washing machines have to start under load due to the weight of the clothes, water and the drum. Hence, the Additional Starting Power \u003cstrong\u003eWa\u003c\/strong\u003e should be taken as 2 times the Running Power \u003cstrong\u003eWr\u003c\/strong\u003e. This starting power normally lasts from 2 to 5 seconds.\u003c\/p\u003e\n\u003cp\u003eThe Watt rating of the microwaves normally indicates output cooking power in Watts. As the microwave is not an efficient device, the AC input power in Watts should be taken as 2 times the output cooking power in Watts i.e. the Additional Continuous Power \u003cstrong\u003eWa\u003c\/strong\u003e should be taken as 1 time the Running Power \u003cstrong\u003eWr\u003c\/strong\u003e. Hence, a microwave with 900 Watt cooking power will require an 1800 Watt inverter. \u003cstrong\u003e(If the power rating of the inverter is indicated as the AC input power in Watts, the factor of 2 is not applicable).\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe following symbols and equations are used in the sizing of an inverter example below:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTotal Running Power of the items selected, Watts – \u003cstrong\u003eWrt\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eHighest Additional Starting Power out of the items selected, Watts – \u003cstrong\u003eWah\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e*Highest power for sizing purpose, Watts – \u003cstrong\u003eWrt + Wah\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003e* It is assumed that only one out of the selected items starts at one time\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003eSince the AC loads rarely start at the same time, the load with the highest Additional Starting Power \u003cstrong\u003eWah\u003c\/strong\u003e has been factored in.\u003c\/p\u003e\n\u003cp\u003eExample:\u003cbr\u003e\u003c\/p\u003e\n\u003ctable id=\"tablepress-15\" class=\"tablepress tablepress-id-15 tablepress-responsive\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"row-1 odd\"\u003e\n\u003cth class=\"column-1\"\u003e\n\u003cp\u003e\u003csmall\u003eDevice \/ Appliance\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/th\u003e\n\u003cth class=\"column-2\"\u003e\n\u003cp\u003e\u003csmall\u003eRunning Power, Wr, Watts\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/th\u003e\n\u003cth class=\"column-3\"\u003e\n\u003cp\u003e\u003csmall\u003eAdditional\u003cbr\u003eStarting Power or Additional Continuous Power *, Wa, Watts\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/th\u003e\n\u003cth class=\"column-4\"\u003e\n\u003cp\u003e\u003csmall\u003eQuantity\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/th\u003e\n\u003cth class=\"column-5\"\u003e\n\u003cp\u003e\u003csmall\u003eExtended\u003cbr\u003eRunning Power, Wt, Watts\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody class=\"row-hover\"\u003e\n\u003ctr class=\"row-2 even\"\u003e\n\u003ctd class=\"column-1\"\u003e\n\u003cp\u003e\u003csmall\u003eRefrigerator – Electric Compressor based\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"column-2\"\u003e\n\u003cp\u003e\u003csmall\u003e200\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"column-3\"\u003e\n\u003cp\u003e\u003csmall\u003e800\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"column-4\"\u003e\n\u003cp\u003e\u003csmall\u003e1\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"column-5\"\u003e\n\u003cp\u003e\u003csmall\u003e200\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"row-3 odd\"\u003e\n\u003ctd class=\"column-1\"\u003e\n\u003cp\u003e\u003csmall\u003eColor TV\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"column-2\"\u003e\n\u003cp\u003e\u003csmall\u003e225\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"column-3\"\u003e\n\u003cp\u003e\u003csmall\u003e450\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"column-4\"\u003e\n\u003cp\u003e\u003csmall\u003e1\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"column-5\"\u003e\n\u003cp\u003e\u003csmall\u003e225\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"row-4 even\"\u003e\n\u003ctd class=\"column-1\"\u003e\n\u003cp\u003e\u003csmall\u003eLaptop Adapter\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"column-2\"\u003e\n\u003cp\u003e\u003csmall\u003e120\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"column-3\"\u003e\n\u003cp\u003e\u003csmall\u003e240\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"column-4\"\u003e\n\u003cp\u003e\u003csmall\u003e1\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"column-5\"\u003e\n\u003cp\u003e\u003csmall\u003e120\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"row-5 odd\"\u003e\n\u003ctd class=\"column-1\"\u003e\n\u003cp\u003e\u003csmall\u003eIncandescent Lamps\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"column-2\"\u003e\n\u003cp\u003e\u003csmall\u003e60\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"column-3\"\u003e\n\u003cp\u003e\u003csmall\u003e0\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"column-4\"\u003e\n\u003cp\u003e\u003csmall\u003e6\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"column-5\"\u003e\n\u003cp\u003e\u003csmall\u003e360\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e*\u003c\/strong\u003e \u003cem\u003eAdditional Continuous Power is applicable to SMPS based loads that have no Power Factor Correction.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003eTotal Extended Running Power, \u003cstrong\u003eWrt\u003c\/strong\u003e = 200 + 225 + 120 + 360 = \u003cstrong\u003e905\u003c\/strong\u003e Watts\u003c\/p\u003e\n\u003cp\u003eHighest Additional Starting Power, \u003cstrong\u003eWah\u003c\/strong\u003e = \u003cstrong\u003e800\u003c\/strong\u003e Watts\u003c\/p\u003e\n\u003cp\u003eHighest Power for sizing the inverter = Total Running Power, \u003cstrong\u003eWrt\u003c\/strong\u003e(905 W) + Highest Additional Starting Power, \u003cstrong\u003eWah\u003c\/strong\u003e (800 W) = \u003cstrong\u003e1705\u003c\/strong\u003e Watts\u003c\/p\u003e\n\u003ch5 class=\"r-faqs--faq-question j-faqs--question\"\u003eWhat are the electrical standards pertaining to DC-AC inverters?\u003c\/h5\u003e\n\u003cdiv class=\"r-faqs--faq-answer j-faqs--answer open\"\u003e\n\u003cmeta charset=\"utf-8\"\u003e\n\u003cp\u003eThe DC input voltage must conform to that of the electrical system and battery bank. 12 volts is recommended for small, simple systems. 24 and 48 volts are the common standards for higher capacities. A higher voltage system carries less current, which makes the system wiring cheaper and easier.\u003c\/p\u003e\n\u003cp\u003eThe inverter’s AC output must conform to the conventional power in the region to run locally available appliances. The standard for AC utility service in North America is 120 and 240 Volts at a frequency of 60 Hertz (cycles per second). In Europe, South America, and most other places, it is 230 volts at 50 Hertz.\u003c\/p\u003e\n\u003ch5 class=\"r-faqs--faq-question j-faqs--question\"\u003eWhat are \"continuous\" and \"surge\" power capacity ratings for DC-AC inverters?\u003c\/h5\u003e\n\u003cdiv class=\"r-faqs--faq j-faqs--single\" id=\"What-are-continuous-and-surge-power-capacity-ratings-for-DC-AC-inverters\"\u003e\n\u003cdiv class=\"r-faqs--faq-answer j-faqs--answer open\"\u003e\n\u003cp\u003eHow much load can an inverter handle? Its power output is rated in Watts.  There are two levels of power rating -a continuous rating and a surge rating. Continuous means the amount of power the inverter can handle for an indefinite period of hours. When an inverter is rated at a certain number of Watts, that number generally refers to its continuous rating. The “surge power” indicates the power to handle instantaneous overload of a few seconds to provide the higher power required to start certain type of devices and appliances.  Resistive types of loads (like incandescent lamps, toaster, coffee maker, electric range, iron etc) do not require extra power to start. Their starting power is the same as their running power.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cspan class=\"r-faqs--faq-toggle s-read-more j-faqs--toggle\"\u003e\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"r-faqs--faq j-faqs--single\"\u003e\n\u003ch5 class=\"r-faqs--faq-question j-faqs--question\"\u003eHow do \"surge power\" electrical loads affect DC-AC inverter operation?\u003c\/h5\u003e\n\u003cp\u003eIf an inverter cannot efficiently feed the surge power, it may simply shut down instead of starting the device. If the inverter’s surge capacity is marginal, its output voltage will dip during the surge. This can cause a dimming of the lights in the house, and will sometimes crash a computer.\u003c\/p\u003e\n\u003cp\u003eAny weakness in the battery and cabling to the inverter will further limit its ability to start a motor. A battery bank that is undersized, in poor condition, or has corroded connections, can be a weak link in the power chain. The inverter cables and the battery interconnect cables must be sized properly. The spike of DC current through these cables is many hundreds of amps at the instant of a motor starting for example.\u003c\/p\u003e\n\u003ch5 class=\"r-faqs--faq-question j-faqs--question\"\u003eHow should I size my DC-AC inverter for loads that require starting surge?\u003c\/h5\u003e\n\u003cdiv class=\"r-faqs--faq j-faqs--single\" id=\"How-should-I-size-my-DC-AC-inverter-for-loads-that-require-starting-surge\"\u003e\n\u003cdiv class=\"r-faqs--faq-answer j-faqs--answer open\"\u003e\n\u003cp\u003eObserve the following guideline to determine the continuous wattage of the inverter for powering loads that require starting surge. (Multiply the running watts of the device\/appliance by the Surge Factor)\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003e\u003cstrong\u003eNOTE:\u003c\/strong\u003e The surge power rating specified for this inverter is valid for duration of less than 1 second. This very short duration may not be sufficient to start motor based loads which may require up to 5 seconds to complete starting process. Hence, for purposes of sizing the inverter, use only the continuous power rating of this inverter.\u003c\/em\u003e\u003c\/p\u003e\n\u003ctable id=\"tablepress-16\" class=\"tablepress tablepress-id-16 tablepress-responsive\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"row-1 odd\"\u003e\n\u003cth class=\"column-1\"\u003e\n\u003cp\u003e\u003csmall\u003eDevice \/ Appliance\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/th\u003e\n\u003cth class=\"column-2\"\u003e\n\u003cp\u003e\u003csmall\u003eSurge Factor\u003cbr\u003e(No. of times the running power rating of the device\/appliance)\u003c\/small\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody class=\"row-hover\"\u003e\n\u003ctr class=\"row-2 even\"\u003e\n\u003ctd class=\"column-1\"\u003e\n\u003cp\u003e\u003csmall\u003eRefrigerator \/ Freezer\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"column-2\"\u003e\n\u003cp\u003e\u003csmall\u003e5\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"row-3 odd\"\u003e\n\u003ctd class=\"column-1\"\u003e\n\u003cp\u003e\u003csmall\u003eAir Compressors\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"column-2\"\u003e\n\u003cp\u003e\u003csmall\u003e4\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"row-4 even\"\u003e\n\u003ctd class=\"column-1\"\u003e\n\u003cp\u003e\u003csmall\u003eDishwasher\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"column-2\"\u003e\n\u003cp\u003e\u003csmall\u003e3\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"row-5 odd\"\u003e\n\u003ctd class=\"column-1\"\u003e\n\u003cp\u003e\u003csmall\u003eSump pump\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"column-2\"\u003e\n\u003cp\u003e\u003csmall\u003e3\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"row-6 even\"\u003e\n\u003ctd class=\"column-1\"\u003e\n\u003cp\u003e\u003csmall\u003eFurnace fans\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"column-2\"\u003e\n\u003cp\u003e\u003csmall\u003e3\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"row-7 odd\"\u003e\n\u003ctd class=\"column-1\"\u003e\n\u003cp\u003e\u003csmall\u003eIndustrial motors\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"column-2\"\u003e\n\u003cp\u003e\u003csmall\u003e3\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"row-8 even\"\u003e\n\u003ctd class=\"column-1\"\u003e\n\u003cp\u003e\u003csmall\u003eCircular saw\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"column-2\"\u003e\n\u003cp\u003e\u003csmall\u003e3\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"row-9 odd\"\u003e\n\u003ctd class=\"column-1\"\u003e\n\u003cp\u003e\u003csmall\u003eBench Grinder\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"column-2\"\u003e\n\u003cp\u003e\u003csmall\u003e3\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"row-10 even\"\u003e\n\u003ctd class=\"column-1\"\u003e\n\u003cp\u003e\u003csmall\u003ePortable diesel \/ kerosene fuel heater\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"column-2\"\u003e\n\u003cp\u003e\u003csmall\u003e2\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cspan class=\"r-faqs--faq-toggle s-read-more j-faqs--toggle\"\u003e\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"r-faqs--faq j-faqs--single\"\u003e\n\u003cdiv class=\"r-faqs--faq j-faqs--single\" id=\"How-should-I-size-my-DC-AC-inverter-to-operate-a-microwave\"\u003e\n\u003ch5 class=\"r-faqs--faq-question j-faqs--question\"\u003eHow should I size my DC-AC inverter to operate a microwave?\u003c\/h5\u003e\n\u003cspan class=\"r-faqs--faq-toggle s-read-more j-faqs--toggle\"\u003e\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"r-faqs--faq j-faqs--single\"\u003e\n\u003cdiv class=\"r-faqs--faq j-faqs--single\" id=\"How-should-I-size-my-DC-AC-inverter-to-operate-a-microwave\"\u003e\n\u003cdiv class=\"r-faqs--faq-answer j-faqs--answer open\"\u003e\n\u003cp\u003eThe power rating of the microwave generally refers to the cooking power. The electrical power consumed by the microwave will be approximately 2 times the cooking power. The “surge power” of the inverter should be 2 times the electrical power (i.e., 4 times the cooking power). Please note that the surge power of the microwave is not as long as the motor load and hence, the surge power of the inverter can be considered to determine adequacy of meeting the starting surge power.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cspan class=\"r-faqs--faq-toggle s-read-more j-faqs--toggle\"\u003e\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"r-faqs--faq j-faqs--single\"\u003e\n\u003ch5 class=\"r-faqs--faq-question j-faqs--question\"\u003eHow should I size my DC-AC inverter to power a water supply pump?\u003c\/h5\u003e\n\u003cp\u003eA water well or pressure pump often places the greatest demand on the inverter. It warrants special consideration. Most pumps draw a very high surge of current during start up. The inverter must have sufficient surge capacity to handle it while running any other loads that may be on. It is important to size an inverter sufficiently, especially to handle the starting surge (If the exact starting rating is not available, the starting surge can be taken as 3 times the normal running rating of the pump). Oversize it still further if you want it to start the pump without causing lights to dim or blink.\u003c\/p\u003e\n\u003cp\u003eIn North America, most pumps (especially submersibles) run on 240 VAC, while smaller appliances and lights use 120 VAC. To obtain 240 VAC from a 120 VAC inverter, use a 120 VAC to 240 VAC transformer. If you do not already have a pump installed, you can get a 120 volt pump if you don’t need more than 1\/2 HP.\u003c\/p\u003e\n\u003ch5 class=\"r-faqs--faq-question j-faqs--question\"\u003eWhat is \"idle power\" in a DC-AC inverter?\u003c\/h5\u003e\n\u003cdiv class=\"r-faqs--faq j-faqs--single\" id=\"What-is-idle-power-in-a-DC-AC-inverter\"\u003e\n\u003cdiv class=\"r-faqs--faq-answer j-faqs--answer open\"\u003e\n\u003cp\u003eIdle power is the consumption of the inverter when it is on, but no loads are running. It is “wasted” power, so if you expect the inverter to be on for many hours during which there is very little load (as in most residential situations), you want this to be as low as possible.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cspan class=\"r-faqs--faq-toggle s-read-more j-faqs--toggle\"\u003e\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"r-faqs--faq j-faqs--single\"\u003e\n\u003ch5 class=\"r-faqs--faq-question j-faqs--question\"\u003eWhat are Phantom and idling loads?\u003c\/h5\u003e\n\u003cp\u003eMost of the modern gadgets draw some power whenever they are plugged in. Some of them use power to do nothing at all. An example is a TV with a remote control. Its electric eye system is on day and night, watching for your signal to turn the screen on. Every appliance with an external wall-plug transformer uses power even when the appliance is turned off. These little loads are called “phantom loads” because their power draw is unexpected, unseen, and easily forgotten.\u003c\/p\u003e\n\u003cp\u003eA similar concern is “idling loads.” These are devices that must be on all the time in order to function when needed. These include smoke detectors, alarm systems, motion detector lights, fax machines, and answering machines. Central heating systems have a transformer in their thermostat circuit that stays on all the time. Cordless (rechargeable) appliances draw power even after their batteries reach a full charge. If in doubt, feel the device. If it’s warm, that indicates wasted energy.\u003c\/p\u003e\n\u003ch5 class=\"r-faqs--faq-question j-faqs--question\"\u003eCan a standard DC-AC inverter be connected in parallel with another AC source\/ DC-AC inverter \/ electrical utility?\u003c\/h5\u003e\n\u003cdiv class=\"r-faqs--faq j-faqs--single\" id=\"Can-a-standard-DC-AC-inverter-be-connected-in-parallel-with-another-AC-source-DC-AC-inverter-electrical-utility\"\u003e\n\u003cdiv class=\"r-faqs--faq-answer j-faqs--answer open\"\u003e\n\u003cp\u003eThe AC output of standard inverters cannot be synchronised with another AC source and hence, it is not suitable for paralleling. The AC output of the inverter should never be connected directly to an electrical breaker panel \/ load center which is also fed from the utility power \/generator. Such a connection may result in parallel operation of the different power sources and AC power from the utility \/ generator will be fed back into the inverter which will instantly damage the output section of the inverter and may also pose a fire and safety hazard.\u003c\/p\u003e\n\u003cp\u003eIf an electrical breaker panel \/ load center is fed from an inverter and this panel is also required to be powered from additional alternate AC sources, the AC power from all the AC sources like the utility \/ generator \/ inverter should first be fed to a manual selector switch and the output of the selector switch should be connected to the electrical breaker panel \/ load center. To prevent possibility of paralleling and severe damage to the inverter, never use a simple jumper cable with a male plug on both ends to connect the AC output of the inverter to a handy wall receptacle in the home\/RV.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cspan class=\"r-faqs--faq-toggle s-read-more j-faqs--toggle\"\u003e\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"r-faqs--faq j-faqs--single\"\u003e\n\u003ch5 class=\"r-faqs--faq-question j-faqs--question\"\u003eHow can DC-AC inverters be connected to multi-wire branch circuits?\u003c\/h5\u003e\n\u003cdiv class=\"r-faqs--faq j-faqs--single\" id=\"How-can-DC-AC-inverters-be-connected-to-multi-wire-branch-circuits\"\u003e\n\u003cdiv class=\"r-faqs--faq-answer j-faqs--answer open\"\u003e\n\u003cp\u003eDo not directly connect the hot side of the inverter to the two hot legs of the 120 \/ 240 VAC electrical breaker panel \/ load centre where multi-wire ( common neutral ) branch circuit wiring method is used for distribution of AC power. This may lead to overloading\/overheating of the neutral conductor and is a risk of fire.\u003c\/p\u003e\n\u003cp\u003eA split phase transformer (isolated or auto-transformer ) of suitable wattage rating ( 25% more than the wattage rating of the inverter ) with primary of 120 VAC and secondary of 120 \/ 240 VAC ( Two 120 VAC split phases 180 degrees apart) should be used. The hot and neutral of the 120 VAC output of the inverter should be fed to the primary of this transformer and the 2 hot outputs (120 VAC split phases ) and the neutral from the secondary of this transformer should be connected to the electrical breaker panel\/ load centre.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cspan class=\"r-faqs--faq-toggle s-read-more j-faqs--toggle\"\u003e\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"r-faqs--faq j-faqs--single\" id=\"How-should-I-size-my-DC-AC-inverter-to-supply-computer-or-printer-loads\"\u003e\n\u003ch5 class=\"r-faqs--faq-question j-faqs--question\"\u003eHow should I size my DC-AC inverter to supply computer or printer loads?\u003c\/h5\u003e\n\u003cdiv class=\"r-faqs--faq j-faqs--single\" id=\"How-should-I-size-my-DC-AC-inverter-to-supply-computer-or-printer-loads\"\u003e\n\u003cdiv class=\"r-faqs--faq-answer j-faqs--answer open\"\u003e\n\u003cp\u003eComputers and Printers generally come with in-built switch-mode power supplies (see \u003ca href=\"https:\/\/samlexamerica.com\/resources-support\/application-notes\/\"\u003eapplication notes\u003c\/a\u003e and \u003ca href=\"https:\/\/samlexamerica.com\/resources-support\/faq\/inverters-powering-direct-embedded-smps\/\"\u003eFAQs on switch mode power supplies (SMPS)\u003c\/a\u003e) that have extremely low power factor on account of the extremely peaky and non-linear nature of the current drawn by them from the AC source. Hence for such loads we recommend using inverters with three times the advertised power consumption of the computer or printer loads.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cspan class=\"r-faqs--faq-toggle s-read-more j-faqs--toggle\"\u003e\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"r-faqs--faq j-faqs--single\"\u003e\n\u003ch5 class=\"r-faqs--faq-question j-faqs--question\"\u003eWhat is the difference between a 12V, 24V and 48V inverter?\u003c\/h5\u003e\n\u003cdiv class=\"o-resource-body\"\u003e\n\u003cdiv class=\"r-faqs j-faqs\"\u003e\n\u003cdiv class=\"r-faqs--container\"\u003e\n\u003cdiv class=\"r-faqs--faqs j-faqs--faqs\"\u003e\n\u003cdiv class=\"r-faqs--faq j-faqs--single\" id=\"What-is-the-difference-between-a-12V-24V-and-48V-inverter\"\u003e\n\u003cdiv class=\"r-faqs--faq-answer j-faqs--answer open\"\u003e\n\u003cp\u003eA 12-V can be fed from a 12V battery or DC supply. Similarly 24V and 48V inverters can be fed from 24V and 48V batteries\/DC power supplies, respectively. Cars usually have 12V batteries. Trucks have 24V batteries.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Samlex America","offers":[{"title":"Default Title","offer_id":50359596712219,"sku":"OGL-67251","price":178.8,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0724\/2026\/2171\/files\/67251XL.jpg?v=1749567217"},{"product_id":"samlex-100w-fully-isolated-dc-dc-converter-8a-20-35v-input-12-5v-output-idc-100b-12","title":"Samlex 100W Fully Isolated DC-DC Converter - 8A - 20-35V Input - 12.5V Output [IDC-100B-12]","description":"\u003ch2\u003e\u003cspan style=\"text-decoration: underline;\"\u003eSamlex 100W Fully Isolated DC-DC Converter - 8A - 20-35V Input - 12.5V Output [IDC-100B-12]\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003eIDC-100 series is a complete line of high efficiency 100 Watt isolated DC-DC converters suitable for applications requiring galvanic isolation between the input and the output. IDC-100B-12 isolated DC-DC converter provides a highly regulated output DC voltage of 12.5 Volts for an input DC voltage range of 20-35 Volts and rated output current of 8 Amps (at 35 Volts input). Features of this isolated DC-DC converter include compact housing, fold-back current limiting and protection against short circuit, overheating, overvoltage and reverse polarity connection. The unit comes with 1\/4” push-on flat blade “quick disconnect” connectors. IDC-100B-12 isolated DC-DC converter is EMI\/EMC compliant and conforms to European standards EN50081-1 (for EMI), EN50082-1 (for EMC) and the European Automotive Directive 95\/54\/CE.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eFully Isolated\u003c\/li\u003e\n\u003cli\u003eShort Circuit Protected\u003c\/li\u003e\n\u003cli\u003eCurrent Limited\u003c\/li\u003e\n\u003cli\u003e2 Year Warranty\u003c\/li\u003e\n\u003cli\u003eCE Approved\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\n\u003cmeta charset=\"utf-8\"\u003eProduct Specifications\u003c\/h3\u003e\n\u003ch2\u003e\u003cspan style=\"text-decoration: underline;\"\u003eSamlex 100W Fully Isolated DC-DC Converter - 8A - 20-35V Input - 12.5V Output [IDC-100B-12] Product Specifications\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eInput: 20-35 VDC\u003c\/li\u003e\n\u003cli\u003eOutput: 12.5 VDC\u003c\/li\u003e\n\u003cli\u003eAmps: 8 Amps\u003c\/li\u003e\n\u003cli\u003eWeight: 1.2 (lbs)\u003c\/li\u003e\n\u003cli\u003eWeight: 0.54 (kg)\u003c\/li\u003e\n\u003cli\u003eDimensions: 6 x 3.5 x 1.9 (in)\u003c\/li\u003e\n\u003cli\u003eDimensions: 15.2 x 8.9 x 4.8 (cm)\u003c\/li\u003e\n\u003cli\u003eSafety: CE\u003c\/li\u003e\n\u003cli\u003eWarranty: 2 Year Limited\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eEarth moving equipment\u003c\/li\u003e\n\u003cli\u003eHeavy trucks\u003c\/li\u003e\n\u003cli\u003eBuses\u003c\/li\u003e\n\u003cli\u003eMarine vehicles\u003c\/li\u003e\n\u003cli\u003eCB radios\u003c\/li\u003e\n\u003cli\u003e12 Volt lighting systems\u003c\/li\u003e\n\u003cli\u003eAM\/FM sound systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cimg alt=\"Warning\" src=\"https:\/\/productimageserver.com\/prop65\/6pt.png\"\u003e\u003cstrong\u003eWARNING:\u003c\/strong\u003e This product can expose you to chemicals which are known to the State of California to cause cancer, birth defects or other reproductive harm. For more information go to \u003ca href=\"http:\/\/P65Warnings.ca.gov\"\u003eP65Warnings.ca.gov\u003c\/a\u003e.\u003c\/p\u003e\n\u003c!--- cis2:m2lsnZdp ---\u003e\n\u003ch3\u003e\u003cspan\u003eProduct Manual\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/productimageserver.com\/literature\/ownersManual\/67252OM.pdf\" target=\"_blank\"\u003eOwner's Manual (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/productimageserver.com\/literature\/brochure\/67252BR.pdf\" target=\"_blank\"\u003eBrochure (pdf)\u003c\/a\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eProduct Warranty\u003c\/span\u003e\u003c\/h3\u003e\n\u003ch2 class=\"o-product--description\"\u003e3 Years Limited Warranty\u003c\/h2\u003e\n\u003ch3 class=\"o-product--description\"\u003eProduct FAQs\u003c\/h3\u003e\n\u003ch5 class=\"o-product--description\"\u003eWhat is a Pure Sine Wave Inverter?\u003c\/h5\u003e\n\u003cdiv class=\"o-product--description\"\u003eThe output voltage of a sine wave inverter has a sine wave form like the sine wave form of the mains \/ utility voltage. In a sine wave, the voltage rises and falls smoothly with a smoothly changing phase angle and also changes its polarity instantly when it crosses 0 Volts.\n\u003cdiv class=\"r-faqs--faq-answer j-faqs--answer open\"\u003e\n\u003cdiv id=\"What-are-the-advantages-of-Pure-Sine-Wave-inverters\" class=\"r-faqs--faq j-faqs--single\"\u003e\n\u003ch5 class=\"r-faqs--faq-question j-faqs--question\"\u003eWhat are the advantages of Pure Sine Wave inverters?\u003c\/h5\u003e\n\u003cdiv class=\"r-faqs--faq-answer j-faqs--answer open\"\u003e\n\u003cul\u003e\n\u003cli\u003eThe output wave-form is a sine-wave with\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003every low harmonic distortion\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand clean power like utility supplied electricity\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eInductive loads\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003elike microwaves and motors run faster, quieter and cooler\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eReduces audible and electrical noise\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ein fans, fluorescent lights, audio amplifiers, TV, fax and answering machines\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePrevents crashes\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ein computers, weird print outs and glitches in monitors\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cspan class=\"r-faqs--faq-toggle s-read-more j-faqs--toggle\"\u003e\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"r-faqs--faq j-faqs--single\"\u003e\n\u003cdiv id=\"What-is-a-Modified-Sine-Wave-Inverter\" class=\"r-faqs--faq j-faqs--single\"\u003e\n\u003ch5 class=\"r-faqs--faq-question j-faqs--question\"\u003eWhat is a Modified Sine Wave Inverter?\u003c\/h5\u003e\n\u003cdiv class=\"r-faqs--faq-answer j-faqs--answer open\"\u003e\n\u003cp\u003eIn a modified sine wave, the voltage rises and falls abruptly, the phase angle also changes abruptly and it sits at 0 Volts for some time before changing its polarity.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cspan class=\"r-faqs--faq-toggle s-read-more j-faqs--toggle\"\u003e\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"r-faqs--faq j-faqs--single\"\u003e\n\u003ch5 class=\"r-faqs--faq-question j-faqs--question\"\u003eWhat are the advantages of Pure Sine Wave inverters?\u003c\/h5\u003e\n\u003cdiv class=\"r-faqs--faq-answer j-faqs--answer open\"\u003e\n\u003cul\u003e\n\u003cli\u003eThe output wave-form is a sine-wave with\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003every low harmonic distortion\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand clean power like utility supplied electricity\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eInductive loads\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003elike microwaves and motors run faster, quieter and cooler\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eReduces audible and electrical noise\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ein fans, fluorescent lights, audio amplifiers, TV, fax and answering machines\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePrevents crashes\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ein computers, weird print outs and glitches in monitors\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"o-resource-body\"\u003e\n\u003cdiv class=\"r-faqs j-faqs\"\u003e\n\u003cdiv class=\"r-faqs--container\"\u003e\n\u003cdiv class=\"r-faqs--faqs j-faqs--faqs\"\u003e\n\u003cdiv id=\"Which-devices-will-not-function-properly-from-a-Modified-Sine-Wave-Inverter\" class=\"r-faqs--faq j-faqs--single\"\u003e\n\u003ch5 class=\"r-faqs--faq-question j-faqs--question\"\u003eWhich devices will not function properly from a Modified Sine Wave Inverter?\u003c\/h5\u003e\n\u003cdiv class=\"r-faqs--faq-answer j-faqs--answer open\"\u003e\n\u003cp\u003eAny device that uses a control circuitry that senses the phase (for voltage \/ speed control) or instantaneous zero voltage crossing (for timing control) will not work properly from a voltage that has a modified sine wave-form. Also, as the modified sine wave is a form of square wave, it is comprised of multiple sine waves of odd harmonics (multiples) of the fundamental frequency of the modified sine wave. For example, a 60 Hz. modified sine wave will consist of sine waves with odd harmonic frequencies of 3rd (180 Hz), 5th (300 Hz.), 7th (420 Hz.) and so on. The high frequency harmonic content in a modified sine wave produces enhanced radio interference, higher heating effect in motors \/ microwaves and produces overloading due to lowering of the impedance of low frequency filter capacitors \/ power factor improvement capacitors.\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eSome examples of devices that may not work properly with modified sine wave and may also get damaged are given below\u003c\/em\u003e\u003c\/p\u003e\n\u003cul type=\"circle\"\u003e\n\u003cli\u003eLaser printers, photocopiers, magneto-optical hard drives\u003c\/li\u003e\n\u003cli\u003eThe built-in clocks in devices such as clock radios, alarm clocks, coffee makers, bread-makers, VCR, microwave ovens etc may not keep time correctly\u003c\/li\u003e\n\u003cli\u003eOutput voltage control devices like dimmers, ceiling fan \/ motor speed control may not work properly (dimming \/ speed control may not function)\u003c\/li\u003e\n\u003cli\u003eSewing machines with speed \/ microprocessor control\u003c\/li\u003e\n\u003cli\u003eTransformer-less capacitive input powered devices like (i) Razors, flashlights, night-lights, smoke detectors etc (ii) Re-chargers for battery packs used in hand power tools.\u003cspan\u003e \u003c\/span\u003e\u003cem\u003eThese may get damaged. Please check with the manufacturer of these types of devices for suitability\u003c\/em\u003e\n\u003c\/li\u003e\n\u003cli\u003eDevices that use radio frequency signals carried by the AC distribution wiring\u003c\/li\u003e\n\u003cli\u003eSome new furnaces with microprocessor control \/ Oil burner primary controls\u003c\/li\u003e\n\u003cli\u003eHigh intensity discharge (HID) lamps like Metal Halide lamps.\u003cspan\u003e \u003c\/span\u003e\u003cem\u003eThese may get damaged. Please check with the manufacturer of these types of devices for suitability\u003c\/em\u003e\n\u003c\/li\u003e\n\u003cli\u003eSome fluorescent lamps \/ light fixtures that have power factor correction capacitors.\u003cspan\u003e \u003c\/span\u003e\u003cem\u003eThe inverter may shut down indicating overload\u003c\/em\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5 class=\"r-faqs--faq-question j-faqs--question\"\u003eWhat is a DC-AC inverter?\u003c\/h5\u003e\n\u003cp\u003eWhen you plug anything into the wall in your home you are usually “plugging in” to the power-grid provided as a service by your utility company. Your utility company supplies you with alternating current (AC) electricity. AC electricity flows in alternate directions many times per second. AC is used for utility grid service because it is more practical for long distance transmission.\u003c\/p\u003e\n\u003cp\u003eBatteries provide direct current electricity (DC) electricity which flows in a single direction.  DC power is what is used in many electronics in the home like laptops, solar cells, LED bulbs, and electric vehicles.  They usually have built-in converters to take the AC power received from a plug-in and convert it to DC.\u003c\/p\u003e\n\u003cp\u003eAn inverter (converter) acts as a power adapter as it converts DC to AC,  AC to DC, and can also change the voltage. It allows a battery-based system to run conventional AC appliances directly or through conventional home wiring.\u003c\/p\u003e\n\u003ch5 class=\"r-faqs--faq-question j-faqs--question\"\u003eWhat are the criteria for selecting the right inverter for a particular application?\u003c\/h5\u003e\n\u003cdiv class=\"r-faqs--faq j-faqs--single\" id=\"What-are-the-criteria-for-selecting-the-right-inverter-for-a-particular-application\"\u003e\n\u003cdiv class=\"r-faqs--faq-answer j-faqs--answer open\"\u003e\n\u003cp\u003eTo choose an inverter; you should first define your needs. Where is the inverter to be used? Inverters are available for use in buildings (including homes), for recreational vehicles, boats, and portable applications. Will it be connected to the utility grid in some way? Electrical conventions and safety standards differ for various applications, so don’t improvise.\u003c\/p\u003e\n\u003cp\u003eWhen sizing an inverter, you need to take into consideration both the\u003cstrong\u003e\u003cem\u003e\u003cspan\u003e \u003c\/span\u003erunning power\u003c\/em\u003e\u003c\/strong\u003e \u003cspan\u003e \u003c\/span\u003e\u003cem\u003e\u003cstrong\u003e(continuous)\u003c\/strong\u003e\u003c\/em\u003e\u003cspan\u003e \u003c\/span\u003eand the additional\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e\u003cem\u003estarting surge power\u003c\/em\u003e\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003erequirements of the AC side loads.\u003c\/p\u003e\n\u003cp\u003eSome loads require much higher starting surge power for the first few seconds before settling down at the running power. The inverter should be sized on the basis of the starting surge power of the AC side load. The total starting surge power is equal to the normal running power plus the additional starting power. The following symbols and equation will be used for explanation purposes:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eRunning Power, Watts – \u003cstrong\u003eWr\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eAdditional Starting Power or Additional Continuous Power, Watts – \u003cstrong\u003eWa\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eTotal Starting Surge Power, Watts = Running Power (\u003cstrong\u003eWr\u003c\/strong\u003e) + Additional Starting Power \/ Additional Continuous Power (\u003cstrong\u003eWa\u003c\/strong\u003e)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe specifications of inverters may include a rating termed Surge Power. Normally, the duration of this Surge Power rating is not quantified in the specifications and is assumed to last for less than 1 second. Unless the Surge Power Rating of the inverter is specified to last for \u0026gt; 5 seconds, this Surge Power specification of the inverter should not be considered for purposes of sizing loads with high and prolonged starting surge power.\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eOnly the Continuous Power rating of the inverter should be considered in such cases\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eElectric motor driven compressor\/pump based loads like refrigerators\/freezers, air conditioners, air compressors, sump and well pumps, etc. require a very high Starting Surge Power of around 5 to 7 times the Running Power for the initial start up. This Starting Surge Power may last for 2 to 5 seconds.  The Additional Starting Power\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eWa\u003c\/strong\u003e should be taken as 4 times the Running Power \u003cstrong\u003eWr\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eSwitched Mode Power Supplies (SMPS) that do not have Power Factor correction draw a non linear, pulsing current with a high Crest Factor (Ratio of instantaneous value and the RMS value) that may reach a value of 4. Also, the effective Power Factor of these types of power supplies is very low around 0.6. If the inverter is sized based on the Running Power of these units, the inverter will be continuously overloaded from instant to instant due to the higher peaks of the pulsing current. The inverter for these units should be sized at 3 times the Running Power of the power supply. Alternatively, for sizing purposes, the Additional Continuous Power \u003cstrong\u003eWa\u003c\/strong\u003e should be taken as 2 times the Running Power \u003cstrong\u003eWr\u003c\/strong\u003e. Consumer electronics like computers, TV, VCR, audio\/ video devices, etc. use this type of power supply.\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e(Please note that this sizing is not applicable if the SMPS has Power Factor correction and the Power Factor is around 0.9)\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eMotors used in washing machines have to start under load due to the weight of the clothes, water and the drum. Hence, the Additional Starting Power \u003cstrong\u003eWa\u003c\/strong\u003e should be taken as 2 times the Running Power \u003cstrong\u003eWr\u003c\/strong\u003e. This starting power normally lasts from 2 to 5 seconds.\u003c\/p\u003e\n\u003cp\u003eThe Watt rating of the microwaves normally indicates output cooking power in Watts. As the microwave is not an efficient device, the AC input power in Watts should be taken as 2 times the output cooking power in Watts i.e. the Additional Continuous Power \u003cstrong\u003eWa\u003c\/strong\u003e should be taken as 1 time the Running Power \u003cstrong\u003eWr\u003c\/strong\u003e. Hence, a microwave with 900 Watt cooking power will require an 1800 Watt inverter. \u003cstrong\u003e(If the power rating of the inverter is indicated as the AC input power in Watts, the factor of 2 is not applicable).\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe following symbols and equations are used in the sizing of an inverter example below:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTotal Running Power of the items selected, Watts – \u003cstrong\u003eWrt\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eHighest Additional Starting Power out of the items selected, Watts – \u003cstrong\u003eWah\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e*Highest power for sizing purpose, Watts – \u003cstrong\u003eWrt + Wah\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003e* It is assumed that only one out of the selected items starts at one time\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003eSince the AC loads rarely start at the same time, the load with the highest Additional Starting Power \u003cstrong\u003eWah\u003c\/strong\u003e has been factored in.\u003c\/p\u003e\n\u003cp\u003eExample:\u003cbr\u003e\u003c\/p\u003e\n\u003ctable id=\"tablepress-15\" class=\"tablepress tablepress-id-15 tablepress-responsive\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"row-1 odd\"\u003e\n\u003cth class=\"column-1\"\u003e\n\u003cp\u003e\u003csmall\u003eDevice \/ Appliance\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/th\u003e\n\u003cth class=\"column-2\"\u003e\n\u003cp\u003e\u003csmall\u003eRunning Power, Wr, Watts\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/th\u003e\n\u003cth class=\"column-3\"\u003e\n\u003cp\u003e\u003csmall\u003eAdditional\u003cbr\u003eStarting Power or Additional Continuous Power *, Wa, Watts\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/th\u003e\n\u003cth class=\"column-4\"\u003e\n\u003cp\u003e\u003csmall\u003eQuantity\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/th\u003e\n\u003cth class=\"column-5\"\u003e\n\u003cp\u003e\u003csmall\u003eExtended\u003cbr\u003eRunning Power, Wt, Watts\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody class=\"row-hover\"\u003e\n\u003ctr class=\"row-2 even\"\u003e\n\u003ctd class=\"column-1\"\u003e\n\u003cp\u003e\u003csmall\u003eRefrigerator – Electric Compressor based\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"column-2\"\u003e\n\u003cp\u003e\u003csmall\u003e200\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"column-3\"\u003e\n\u003cp\u003e\u003csmall\u003e800\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"column-4\"\u003e\n\u003cp\u003e\u003csmall\u003e1\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"column-5\"\u003e\n\u003cp\u003e\u003csmall\u003e200\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"row-3 odd\"\u003e\n\u003ctd class=\"column-1\"\u003e\n\u003cp\u003e\u003csmall\u003eColor TV\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"column-2\"\u003e\n\u003cp\u003e\u003csmall\u003e225\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"column-3\"\u003e\n\u003cp\u003e\u003csmall\u003e450\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"column-4\"\u003e\n\u003cp\u003e\u003csmall\u003e1\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"column-5\"\u003e\n\u003cp\u003e\u003csmall\u003e225\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"row-4 even\"\u003e\n\u003ctd class=\"column-1\"\u003e\n\u003cp\u003e\u003csmall\u003eLaptop Adapter\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"column-2\"\u003e\n\u003cp\u003e\u003csmall\u003e120\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"column-3\"\u003e\n\u003cp\u003e\u003csmall\u003e240\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"column-4\"\u003e\n\u003cp\u003e\u003csmall\u003e1\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"column-5\"\u003e\n\u003cp\u003e\u003csmall\u003e120\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"row-5 odd\"\u003e\n\u003ctd class=\"column-1\"\u003e\n\u003cp\u003e\u003csmall\u003eIncandescent Lamps\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"column-2\"\u003e\n\u003cp\u003e\u003csmall\u003e60\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"column-3\"\u003e\n\u003cp\u003e\u003csmall\u003e0\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"column-4\"\u003e\n\u003cp\u003e\u003csmall\u003e6\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"column-5\"\u003e\n\u003cp\u003e\u003csmall\u003e360\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e*\u003c\/strong\u003e \u003cem\u003eAdditional Continuous Power is applicable to SMPS based loads that have no Power Factor Correction.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003eTotal Extended Running Power, \u003cstrong\u003eWrt\u003c\/strong\u003e = 200 + 225 + 120 + 360 = \u003cstrong\u003e905\u003c\/strong\u003e Watts\u003c\/p\u003e\n\u003cp\u003eHighest Additional Starting Power, \u003cstrong\u003eWah\u003c\/strong\u003e = \u003cstrong\u003e800\u003c\/strong\u003e Watts\u003c\/p\u003e\n\u003cp\u003eHighest Power for sizing the inverter = Total Running Power, \u003cstrong\u003eWrt\u003c\/strong\u003e(905 W) + Highest Additional Starting Power, \u003cstrong\u003eWah\u003c\/strong\u003e (800 W) = \u003cstrong\u003e1705\u003c\/strong\u003e Watts\u003c\/p\u003e\n\u003ch5 class=\"r-faqs--faq-question j-faqs--question\"\u003eWhat are the electrical standards pertaining to DC-AC inverters?\u003c\/h5\u003e\n\u003cdiv class=\"r-faqs--faq-answer j-faqs--answer open\"\u003e\n\u003cmeta charset=\"utf-8\"\u003e\n\u003cp\u003eThe DC input voltage must conform to that of the electrical system and battery bank. 12 volts is recommended for small, simple systems. 24 and 48 volts are the common standards for higher capacities. A higher voltage system carries less current, which makes the system wiring cheaper and easier.\u003c\/p\u003e\n\u003cp\u003eThe inverter’s AC output must conform to the conventional power in the region to run locally available appliances. The standard for AC utility service in North America is 120 and 240 Volts at a frequency of 60 Hertz (cycles per second). In Europe, South America, and most other places, it is 230 volts at 50 Hertz.\u003c\/p\u003e\n\u003ch5 class=\"r-faqs--faq-question j-faqs--question\"\u003eWhat are \"continuous\" and \"surge\" power capacity ratings for DC-AC inverters?\u003c\/h5\u003e\n\u003cdiv class=\"r-faqs--faq j-faqs--single\" id=\"What-are-continuous-and-surge-power-capacity-ratings-for-DC-AC-inverters\"\u003e\n\u003cdiv class=\"r-faqs--faq-answer j-faqs--answer open\"\u003e\n\u003cp\u003eHow much load can an inverter handle? Its power output is rated in Watts.  There are two levels of power rating -a continuous rating and a surge rating. Continuous means the amount of power the inverter can handle for an indefinite period of hours. When an inverter is rated at a certain number of Watts, that number generally refers to its continuous rating. The “surge power” indicates the power to handle instantaneous overload of a few seconds to provide the higher power required to start certain type of devices and appliances.  Resistive types of loads (like incandescent lamps, toaster, coffee maker, electric range, iron etc) do not require extra power to start. Their starting power is the same as their running power.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cspan class=\"r-faqs--faq-toggle s-read-more j-faqs--toggle\"\u003e\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"r-faqs--faq j-faqs--single\"\u003e\n\u003ch5 class=\"r-faqs--faq-question j-faqs--question\"\u003eHow do \"surge power\" electrical loads affect DC-AC inverter operation?\u003c\/h5\u003e\n\u003cp\u003eIf an inverter cannot efficiently feed the surge power, it may simply shut down instead of starting the device. If the inverter’s surge capacity is marginal, its output voltage will dip during the surge. This can cause a dimming of the lights in the house, and will sometimes crash a computer.\u003c\/p\u003e\n\u003cp\u003eAny weakness in the battery and cabling to the inverter will further limit its ability to start a motor. A battery bank that is undersized, in poor condition, or has corroded connections, can be a weak link in the power chain. The inverter cables and the battery interconnect cables must be sized properly. The spike of DC current through these cables is many hundreds of amps at the instant of a motor starting for example.\u003c\/p\u003e\n\u003ch5 class=\"r-faqs--faq-question j-faqs--question\"\u003eHow should I size my DC-AC inverter for loads that require starting surge?\u003c\/h5\u003e\n\u003cdiv class=\"r-faqs--faq j-faqs--single\" id=\"How-should-I-size-my-DC-AC-inverter-for-loads-that-require-starting-surge\"\u003e\n\u003cdiv class=\"r-faqs--faq-answer j-faqs--answer open\"\u003e\n\u003cp\u003eObserve the following guideline to determine the continuous wattage of the inverter for powering loads that require starting surge. (Multiply the running watts of the device\/appliance by the Surge Factor)\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003e\u003cstrong\u003eNOTE:\u003c\/strong\u003e The surge power rating specified for this inverter is valid for duration of less than 1 second. This very short duration may not be sufficient to start motor based loads which may require up to 5 seconds to complete starting process. Hence, for purposes of sizing the inverter, use only the continuous power rating of this inverter.\u003c\/em\u003e\u003c\/p\u003e\n\u003ctable id=\"tablepress-16\" class=\"tablepress tablepress-id-16 tablepress-responsive\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"row-1 odd\"\u003e\n\u003cth class=\"column-1\"\u003e\n\u003cp\u003e\u003csmall\u003eDevice \/ Appliance\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/th\u003e\n\u003cth class=\"column-2\"\u003e\n\u003cp\u003e\u003csmall\u003eSurge Factor\u003cbr\u003e(No. of times the running power rating of the device\/appliance)\u003c\/small\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody class=\"row-hover\"\u003e\n\u003ctr class=\"row-2 even\"\u003e\n\u003ctd class=\"column-1\"\u003e\n\u003cp\u003e\u003csmall\u003eRefrigerator \/ Freezer\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"column-2\"\u003e\n\u003cp\u003e\u003csmall\u003e5\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"row-3 odd\"\u003e\n\u003ctd class=\"column-1\"\u003e\n\u003cp\u003e\u003csmall\u003eAir Compressors\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"column-2\"\u003e\n\u003cp\u003e\u003csmall\u003e4\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"row-4 even\"\u003e\n\u003ctd class=\"column-1\"\u003e\n\u003cp\u003e\u003csmall\u003eDishwasher\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"column-2\"\u003e\n\u003cp\u003e\u003csmall\u003e3\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"row-5 odd\"\u003e\n\u003ctd class=\"column-1\"\u003e\n\u003cp\u003e\u003csmall\u003eSump pump\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"column-2\"\u003e\n\u003cp\u003e\u003csmall\u003e3\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"row-6 even\"\u003e\n\u003ctd class=\"column-1\"\u003e\n\u003cp\u003e\u003csmall\u003eFurnace fans\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"column-2\"\u003e\n\u003cp\u003e\u003csmall\u003e3\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"row-7 odd\"\u003e\n\u003ctd class=\"column-1\"\u003e\n\u003cp\u003e\u003csmall\u003eIndustrial motors\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"column-2\"\u003e\n\u003cp\u003e\u003csmall\u003e3\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"row-8 even\"\u003e\n\u003ctd class=\"column-1\"\u003e\n\u003cp\u003e\u003csmall\u003eCircular saw\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"column-2\"\u003e\n\u003cp\u003e\u003csmall\u003e3\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"row-9 odd\"\u003e\n\u003ctd class=\"column-1\"\u003e\n\u003cp\u003e\u003csmall\u003eBench Grinder\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"column-2\"\u003e\n\u003cp\u003e\u003csmall\u003e3\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"row-10 even\"\u003e\n\u003ctd class=\"column-1\"\u003e\n\u003cp\u003e\u003csmall\u003ePortable diesel \/ kerosene fuel heater\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"column-2\"\u003e\n\u003cp\u003e\u003csmall\u003e2\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cspan class=\"r-faqs--faq-toggle s-read-more j-faqs--toggle\"\u003e\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"r-faqs--faq j-faqs--single\"\u003e\n\u003cdiv class=\"r-faqs--faq j-faqs--single\" id=\"How-should-I-size-my-DC-AC-inverter-to-operate-a-microwave\"\u003e\n\u003ch5 class=\"r-faqs--faq-question j-faqs--question\"\u003eHow should I size my DC-AC inverter to operate a microwave?\u003c\/h5\u003e\n\u003cspan class=\"r-faqs--faq-toggle s-read-more j-faqs--toggle\"\u003e\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"r-faqs--faq j-faqs--single\"\u003e\n\u003cdiv class=\"r-faqs--faq j-faqs--single\" id=\"How-should-I-size-my-DC-AC-inverter-to-operate-a-microwave\"\u003e\n\u003cdiv class=\"r-faqs--faq-answer j-faqs--answer open\"\u003e\n\u003cp\u003eThe power rating of the microwave generally refers to the cooking power. The electrical power consumed by the microwave will be approximately 2 times the cooking power. The “surge power” of the inverter should be 2 times the electrical power (i.e., 4 times the cooking power). Please note that the surge power of the microwave is not as long as the motor load and hence, the surge power of the inverter can be considered to determine adequacy of meeting the starting surge power.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cspan class=\"r-faqs--faq-toggle s-read-more j-faqs--toggle\"\u003e\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"r-faqs--faq j-faqs--single\"\u003e\n\u003ch5 class=\"r-faqs--faq-question j-faqs--question\"\u003eHow should I size my DC-AC inverter to power a water supply pump?\u003c\/h5\u003e\n\u003cp\u003eA water well or pressure pump often places the greatest demand on the inverter. It warrants special consideration. Most pumps draw a very high surge of current during start up. The inverter must have sufficient surge capacity to handle it while running any other loads that may be on. It is important to size an inverter sufficiently, especially to handle the starting surge (If the exact starting rating is not available, the starting surge can be taken as 3 times the normal running rating of the pump). Oversize it still further if you want it to start the pump without causing lights to dim or blink.\u003c\/p\u003e\n\u003cp\u003eIn North America, most pumps (especially submersibles) run on 240 VAC, while smaller appliances and lights use 120 VAC. To obtain 240 VAC from a 120 VAC inverter, use a 120 VAC to 240 VAC transformer. If you do not already have a pump installed, you can get a 120 volt pump if you don’t need more than 1\/2 HP.\u003c\/p\u003e\n\u003ch5 class=\"r-faqs--faq-question j-faqs--question\"\u003eWhat is \"idle power\" in a DC-AC inverter?\u003c\/h5\u003e\n\u003cdiv class=\"r-faqs--faq j-faqs--single\" id=\"What-is-idle-power-in-a-DC-AC-inverter\"\u003e\n\u003cdiv class=\"r-faqs--faq-answer j-faqs--answer open\"\u003e\n\u003cp\u003eIdle power is the consumption of the inverter when it is on, but no loads are running. It is “wasted” power, so if you expect the inverter to be on for many hours during which there is very little load (as in most residential situations), you want this to be as low as possible.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cspan class=\"r-faqs--faq-toggle s-read-more j-faqs--toggle\"\u003e\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"r-faqs--faq j-faqs--single\"\u003e\n\u003ch5 class=\"r-faqs--faq-question j-faqs--question\"\u003eWhat are Phantom and idling loads?\u003c\/h5\u003e\n\u003cp\u003eMost of the modern gadgets draw some power whenever they are plugged in. Some of them use power to do nothing at all. An example is a TV with a remote control. Its electric eye system is on day and night, watching for your signal to turn the screen on. Every appliance with an external wall-plug transformer uses power even when the appliance is turned off. These little loads are called “phantom loads” because their power draw is unexpected, unseen, and easily forgotten.\u003c\/p\u003e\n\u003cp\u003eA similar concern is “idling loads.” These are devices that must be on all the time in order to function when needed. These include smoke detectors, alarm systems, motion detector lights, fax machines, and answering machines. Central heating systems have a transformer in their thermostat circuit that stays on all the time. Cordless (rechargeable) appliances draw power even after their batteries reach a full charge. If in doubt, feel the device. If it’s warm, that indicates wasted energy.\u003c\/p\u003e\n\u003ch5 class=\"r-faqs--faq-question j-faqs--question\"\u003eCan a standard DC-AC inverter be connected in parallel with another AC source\/ DC-AC inverter \/ electrical utility?\u003c\/h5\u003e\n\u003cdiv class=\"r-faqs--faq j-faqs--single\" id=\"Can-a-standard-DC-AC-inverter-be-connected-in-parallel-with-another-AC-source-DC-AC-inverter-electrical-utility\"\u003e\n\u003cdiv class=\"r-faqs--faq-answer j-faqs--answer open\"\u003e\n\u003cp\u003eThe AC output of standard inverters cannot be synchronised with another AC source and hence, it is not suitable for paralleling. The AC output of the inverter should never be connected directly to an electrical breaker panel \/ load center which is also fed from the utility power \/generator. Such a connection may result in parallel operation of the different power sources and AC power from the utility \/ generator will be fed back into the inverter which will instantly damage the output section of the inverter and may also pose a fire and safety hazard.\u003c\/p\u003e\n\u003cp\u003eIf an electrical breaker panel \/ load center is fed from an inverter and this panel is also required to be powered from additional alternate AC sources, the AC power from all the AC sources like the utility \/ generator \/ inverter should first be fed to a manual selector switch and the output of the selector switch should be connected to the electrical breaker panel \/ load center. To prevent possibility of paralleling and severe damage to the inverter, never use a simple jumper cable with a male plug on both ends to connect the AC output of the inverter to a handy wall receptacle in the home\/RV.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cspan class=\"r-faqs--faq-toggle s-read-more j-faqs--toggle\"\u003e\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"r-faqs--faq j-faqs--single\"\u003e\n\u003ch5 class=\"r-faqs--faq-question j-faqs--question\"\u003eHow can DC-AC inverters be connected to multi-wire branch circuits?\u003c\/h5\u003e\n\u003cdiv class=\"r-faqs--faq j-faqs--single\" id=\"How-can-DC-AC-inverters-be-connected-to-multi-wire-branch-circuits\"\u003e\n\u003cdiv class=\"r-faqs--faq-answer j-faqs--answer open\"\u003e\n\u003cp\u003eDo not directly connect the hot side of the inverter to the two hot legs of the 120 \/ 240 VAC electrical breaker panel \/ load centre where multi-wire ( common neutral ) branch circuit wiring method is used for distribution of AC power. This may lead to overloading\/overheating of the neutral conductor and is a risk of fire.\u003c\/p\u003e\n\u003cp\u003eA split phase transformer (isolated or auto-transformer ) of suitable wattage rating ( 25% more than the wattage rating of the inverter ) with primary of 120 VAC and secondary of 120 \/ 240 VAC ( Two 120 VAC split phases 180 degrees apart) should be used. The hot and neutral of the 120 VAC output of the inverter should be fed to the primary of this transformer and the 2 hot outputs (120 VAC split phases ) and the neutral from the secondary of this transformer should be connected to the electrical breaker panel\/ load centre.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cspan class=\"r-faqs--faq-toggle s-read-more j-faqs--toggle\"\u003e\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"r-faqs--faq j-faqs--single\" id=\"How-should-I-size-my-DC-AC-inverter-to-supply-computer-or-printer-loads\"\u003e\n\u003ch5 class=\"r-faqs--faq-question j-faqs--question\"\u003eHow should I size my DC-AC inverter to supply computer or printer loads?\u003c\/h5\u003e\n\u003cdiv class=\"r-faqs--faq j-faqs--single\" id=\"How-should-I-size-my-DC-AC-inverter-to-supply-computer-or-printer-loads\"\u003e\n\u003cdiv class=\"r-faqs--faq-answer j-faqs--answer open\"\u003e\n\u003cp\u003eComputers and Printers generally come with in-built switch-mode power supplies (see \u003ca href=\"https:\/\/samlexamerica.com\/resources-support\/application-notes\/\"\u003eapplication notes\u003c\/a\u003e and \u003ca href=\"https:\/\/samlexamerica.com\/resources-support\/faq\/inverters-powering-direct-embedded-smps\/\"\u003eFAQs on switch mode power supplies (SMPS)\u003c\/a\u003e) that have extremely low power factor on account of the extremely peaky and non-linear nature of the current drawn by them from the AC source. Hence for such loads we recommend using inverters with three times the advertised power consumption of the computer or printer loads.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cspan class=\"r-faqs--faq-toggle s-read-more j-faqs--toggle\"\u003e\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"r-faqs--faq j-faqs--single\"\u003e\n\u003ch5 class=\"r-faqs--faq-question j-faqs--question\"\u003eWhat is the difference between a 12V, 24V and 48V inverter?\u003c\/h5\u003e\n\u003cdiv class=\"o-resource-body\"\u003e\n\u003cdiv class=\"r-faqs j-faqs\"\u003e\n\u003cdiv class=\"r-faqs--container\"\u003e\n\u003cdiv class=\"r-faqs--faqs j-faqs--faqs\"\u003e\n\u003cdiv class=\"r-faqs--faq j-faqs--single\" id=\"What-is-the-difference-between-a-12V-24V-and-48V-inverter\"\u003e\n\u003cdiv class=\"r-faqs--faq-answer j-faqs--answer open\"\u003e\n\u003cp\u003eA 12-V can be fed from a 12V battery or DC supply. Similarly 24V and 48V inverters can be fed from 24V and 48V batteries\/DC power supplies, respectively. Cars usually have 12V batteries. Trucks have 24V batteries.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Samlex America","offers":[{"title":"Default Title","offer_id":50359596777755,"sku":"OGL-67252","price":178.8,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0724\/2026\/2171\/files\/67252XL.jpg?v=1749567218"},{"product_id":"samlex-100w-fully-isolated-dc-dc-converter-8a-30-60v-input-12-5v-output-idc-100c-12","title":"Samlex 100W Fully Isolated DC-DC Converter - 8A - 30-60V Input - 12.5V Output [IDC-100C-12]","description":"\u003ch2\u003e\u003cspan style=\"text-decoration: underline;\"\u003eSamlex 100W Fully Isolated DC-DC Converter - 8A - 30-60V Input - 12.5V Output [IDC-100C-12]\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003eIDC-100 series is a complete line of high efficiency 100 Watt isolated DC-DC converters suitable for applications requiring galvanic isolation between the input and the output. IDC-100C-12 isolated DC-DC converter provides a highly regulated output DC voltage of 12.5 Volts for an input DC voltage range of 30-60 Volts and rated output current of 8 Amps (at 60 Volts input). Features of this isolated DC-DC converter include compact housing, fold-back current limiting and protection against short circuit, overheating, overvoltage and reverse polarity connection. The unit comes with 1\/4” push-on flat blade “quick disconnect” connectors. IDC-100C-12 isolated DC-DC converter is EMI\/EMC compliant and conforms to European standards EN50081-1 (for EMI) and EN50082-1 (for EMC).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eFully Isolated\u003c\/li\u003e\n\u003cli\u003eShort Circuit Protected\u003c\/li\u003e\n\u003cli\u003eCurrent Limited\u003c\/li\u003e\n\u003cli\u003e2 Year Warranty\u003c\/li\u003e\n\u003cli\u003eCE Approved\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\n\u003cmeta charset=\"utf-8\"\u003eProduct Specifications\u003c\/h3\u003e\n\u003ch2\u003e\u003cspan style=\"text-decoration: underline;\"\u003eSamlex 100W Fully Isolated DC-DC Converter - 8A - 30-60V Input - 12.5V Output [IDC-100C-12] Product Specifications\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eInput: 30-60 VDC\u003c\/li\u003e\n\u003cli\u003eOutput: 12.5 VDC\u003c\/li\u003e\n\u003cli\u003eAmps: 8 Amps\u003c\/li\u003e\n\u003cli\u003eWeight: 1.2 (lbs)\u003c\/li\u003e\n\u003cli\u003eWeight: 0.54 (kg)\u003c\/li\u003e\n\u003cli\u003eDimensions: 6 x 3.5 x 1.9 (in)\u003c\/li\u003e\n\u003cli\u003eDimensions: 15.2 x 8.9 x 4.8 (cm)\u003c\/li\u003e\n\u003cli\u003eSafety: CE\u003c\/li\u003e\n\u003cli\u003eWarranty: 2 Year Limited\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eEarth moving equipment\u003c\/li\u003e\n\u003cli\u003eHeavy trucks\u003c\/li\u003e\n\u003cli\u003eBuses\u003c\/li\u003e\n\u003cli\u003eMarine vehicles\u003c\/li\u003e\n\u003cli\u003eCB radios\u003c\/li\u003e\n\u003cli\u003e12 Volt lighting systems\u003c\/li\u003e\n\u003cli\u003eAM\/FM sound systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cimg alt=\"Warning\" src=\"https:\/\/productimageserver.com\/prop65\/6pt.png\"\u003e\u003cstrong\u003eWARNING:\u003c\/strong\u003e This product can expose you to chemicals which are known to the State of California to cause cancer, birth defects or other reproductive harm. For more information go to \u003ca href=\"http:\/\/P65Warnings.ca.gov\"\u003eP65Warnings.ca.gov\u003c\/a\u003e.\u003c\/p\u003e\n\u003c!--- cis2:m2lsnZdp ---\u003e\n\u003ch3\u003e\u003cspan\u003eProduct Manual\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/productimageserver.com\/literature\/ownersManual\/67253OM.pdf\" target=\"_blank\"\u003eOwner's Manual (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/productimageserver.com\/literature\/brochure\/67253BR.pdf\" target=\"_blank\"\u003eBrochure (pdf)\u003c\/a\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eProduct Warranty\u003c\/span\u003e\u003c\/h3\u003e\n\u003ch2 class=\"o-product--description\"\u003e3 Years Limited Warranty\u003c\/h2\u003e\n\u003ch3 class=\"o-product--description\"\u003eProduct FAQs\u003c\/h3\u003e\n\u003ch5 class=\"o-product--description\"\u003eWhat is a Pure Sine Wave Inverter?\u003c\/h5\u003e\n\u003cdiv class=\"o-product--description\"\u003eThe output voltage of a sine wave inverter has a sine wave form like the sine wave form of the mains \/ utility voltage. In a sine wave, the voltage rises and falls smoothly with a smoothly changing phase angle and also changes its polarity instantly when it crosses 0 Volts.\n\u003cdiv class=\"r-faqs--faq-answer j-faqs--answer open\"\u003e\n\u003cdiv id=\"What-are-the-advantages-of-Pure-Sine-Wave-inverters\" class=\"r-faqs--faq j-faqs--single\"\u003e\n\u003ch5 class=\"r-faqs--faq-question j-faqs--question\"\u003eWhat are the advantages of Pure Sine Wave inverters?\u003c\/h5\u003e\n\u003cdiv class=\"r-faqs--faq-answer j-faqs--answer open\"\u003e\n\u003cul\u003e\n\u003cli\u003eThe output wave-form is a sine-wave with\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003every low harmonic distortion\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand clean power like utility supplied electricity\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eInductive loads\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003elike microwaves and motors run faster, quieter and cooler\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eReduces audible and electrical noise\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ein fans, fluorescent lights, audio amplifiers, TV, fax and answering machines\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePrevents crashes\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ein computers, weird print outs and glitches in monitors\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cspan class=\"r-faqs--faq-toggle s-read-more j-faqs--toggle\"\u003e\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"r-faqs--faq j-faqs--single\"\u003e\n\u003cdiv id=\"What-is-a-Modified-Sine-Wave-Inverter\" class=\"r-faqs--faq j-faqs--single\"\u003e\n\u003ch5 class=\"r-faqs--faq-question j-faqs--question\"\u003eWhat is a Modified Sine Wave Inverter?\u003c\/h5\u003e\n\u003cdiv class=\"r-faqs--faq-answer j-faqs--answer open\"\u003e\n\u003cp\u003eIn a modified sine wave, the voltage rises and falls abruptly, the phase angle also changes abruptly and it sits at 0 Volts for some time before changing its polarity.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cspan class=\"r-faqs--faq-toggle s-read-more j-faqs--toggle\"\u003e\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"r-faqs--faq j-faqs--single\"\u003e\n\u003ch5 class=\"r-faqs--faq-question j-faqs--question\"\u003eWhat are the advantages of Pure Sine Wave inverters?\u003c\/h5\u003e\n\u003cdiv class=\"r-faqs--faq-answer j-faqs--answer open\"\u003e\n\u003cul\u003e\n\u003cli\u003eThe output wave-form is a sine-wave with\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003every low harmonic distortion\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand clean power like utility supplied electricity\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eInductive loads\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003elike microwaves and motors run faster, quieter and cooler\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eReduces audible and electrical noise\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ein fans, fluorescent lights, audio amplifiers, TV, fax and answering machines\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePrevents crashes\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ein computers, weird print outs and glitches in monitors\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"o-resource-body\"\u003e\n\u003cdiv class=\"r-faqs j-faqs\"\u003e\n\u003cdiv class=\"r-faqs--container\"\u003e\n\u003cdiv class=\"r-faqs--faqs j-faqs--faqs\"\u003e\n\u003cdiv id=\"Which-devices-will-not-function-properly-from-a-Modified-Sine-Wave-Inverter\" class=\"r-faqs--faq j-faqs--single\"\u003e\n\u003ch5 class=\"r-faqs--faq-question j-faqs--question\"\u003eWhich devices will not function properly from a Modified Sine Wave Inverter?\u003c\/h5\u003e\n\u003cdiv class=\"r-faqs--faq-answer j-faqs--answer open\"\u003e\n\u003cp\u003eAny device that uses a control circuitry that senses the phase (for voltage \/ speed control) or instantaneous zero voltage crossing (for timing control) will not work properly from a voltage that has a modified sine wave-form. Also, as the modified sine wave is a form of square wave, it is comprised of multiple sine waves of odd harmonics (multiples) of the fundamental frequency of the modified sine wave. For example, a 60 Hz. modified sine wave will consist of sine waves with odd harmonic frequencies of 3rd (180 Hz), 5th (300 Hz.), 7th (420 Hz.) and so on. The high frequency harmonic content in a modified sine wave produces enhanced radio interference, higher heating effect in motors \/ microwaves and produces overloading due to lowering of the impedance of low frequency filter capacitors \/ power factor improvement capacitors.\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eSome examples of devices that may not work properly with modified sine wave and may also get damaged are given below\u003c\/em\u003e\u003c\/p\u003e\n\u003cul type=\"circle\"\u003e\n\u003cli\u003eLaser printers, photocopiers, magneto-optical hard drives\u003c\/li\u003e\n\u003cli\u003eThe built-in clocks in devices such as clock radios, alarm clocks, coffee makers, bread-makers, VCR, microwave ovens etc may not keep time correctly\u003c\/li\u003e\n\u003cli\u003eOutput voltage control devices like dimmers, ceiling fan \/ motor speed control may not work properly (dimming \/ speed control may not function)\u003c\/li\u003e\n\u003cli\u003eSewing machines with speed \/ microprocessor control\u003c\/li\u003e\n\u003cli\u003eTransformer-less capacitive input powered devices like (i) Razors, flashlights, night-lights, smoke detectors etc (ii) Re-chargers for battery packs used in hand power tools.\u003cspan\u003e \u003c\/span\u003e\u003cem\u003eThese may get damaged. Please check with the manufacturer of these types of devices for suitability\u003c\/em\u003e\n\u003c\/li\u003e\n\u003cli\u003eDevices that use radio frequency signals carried by the AC distribution wiring\u003c\/li\u003e\n\u003cli\u003eSome new furnaces with microprocessor control \/ Oil burner primary controls\u003c\/li\u003e\n\u003cli\u003eHigh intensity discharge (HID) lamps like Metal Halide lamps.\u003cspan\u003e \u003c\/span\u003e\u003cem\u003eThese may get damaged. Please check with the manufacturer of these types of devices for suitability\u003c\/em\u003e\n\u003c\/li\u003e\n\u003cli\u003eSome fluorescent lamps \/ light fixtures that have power factor correction capacitors.\u003cspan\u003e \u003c\/span\u003e\u003cem\u003eThe inverter may shut down indicating overload\u003c\/em\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5 class=\"r-faqs--faq-question j-faqs--question\"\u003eWhat is a DC-AC inverter?\u003c\/h5\u003e\n\u003cp\u003eWhen you plug anything into the wall in your home you are usually “plugging in” to the power-grid provided as a service by your utility company. Your utility company supplies you with alternating current (AC) electricity. AC electricity flows in alternate directions many times per second. AC is used for utility grid service because it is more practical for long distance transmission.\u003c\/p\u003e\n\u003cp\u003eBatteries provide direct current electricity (DC) electricity which flows in a single direction.  DC power is what is used in many electronics in the home like laptops, solar cells, LED bulbs, and electric vehicles.  They usually have built-in converters to take the AC power received from a plug-in and convert it to DC.\u003c\/p\u003e\n\u003cp\u003eAn inverter (converter) acts as a power adapter as it converts DC to AC,  AC to DC, and can also change the voltage. It allows a battery-based system to run conventional AC appliances directly or through conventional home wiring.\u003c\/p\u003e\n\u003ch5 class=\"r-faqs--faq-question j-faqs--question\"\u003eWhat are the criteria for selecting the right inverter for a particular application?\u003c\/h5\u003e\n\u003cdiv class=\"r-faqs--faq j-faqs--single\" id=\"What-are-the-criteria-for-selecting-the-right-inverter-for-a-particular-application\"\u003e\n\u003cdiv class=\"r-faqs--faq-answer j-faqs--answer open\"\u003e\n\u003cp\u003eTo choose an inverter; you should first define your needs. Where is the inverter to be used? Inverters are available for use in buildings (including homes), for recreational vehicles, boats, and portable applications. Will it be connected to the utility grid in some way? Electrical conventions and safety standards differ for various applications, so don’t improvise.\u003c\/p\u003e\n\u003cp\u003eWhen sizing an inverter, you need to take into consideration both the\u003cstrong\u003e\u003cem\u003e\u003cspan\u003e \u003c\/span\u003erunning power\u003c\/em\u003e\u003c\/strong\u003e \u003cspan\u003e \u003c\/span\u003e\u003cem\u003e\u003cstrong\u003e(continuous)\u003c\/strong\u003e\u003c\/em\u003e\u003cspan\u003e \u003c\/span\u003eand the additional\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e\u003cem\u003estarting surge power\u003c\/em\u003e\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003erequirements of the AC side loads.\u003c\/p\u003e\n\u003cp\u003eSome loads require much higher starting surge power for the first few seconds before settling down at the running power. The inverter should be sized on the basis of the starting surge power of the AC side load. The total starting surge power is equal to the normal running power plus the additional starting power. The following symbols and equation will be used for explanation purposes:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eRunning Power, Watts – \u003cstrong\u003eWr\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eAdditional Starting Power or Additional Continuous Power, Watts – \u003cstrong\u003eWa\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eTotal Starting Surge Power, Watts = Running Power (\u003cstrong\u003eWr\u003c\/strong\u003e) + Additional Starting Power \/ Additional Continuous Power (\u003cstrong\u003eWa\u003c\/strong\u003e)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe specifications of inverters may include a rating termed Surge Power. Normally, the duration of this Surge Power rating is not quantified in the specifications and is assumed to last for less than 1 second. Unless the Surge Power Rating of the inverter is specified to last for \u0026gt; 5 seconds, this Surge Power specification of the inverter should not be considered for purposes of sizing loads with high and prolonged starting surge power.\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eOnly the Continuous Power rating of the inverter should be considered in such cases\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eElectric motor driven compressor\/pump based loads like refrigerators\/freezers, air conditioners, air compressors, sump and well pumps, etc. require a very high Starting Surge Power of around 5 to 7 times the Running Power for the initial start up. This Starting Surge Power may last for 2 to 5 seconds.  The Additional Starting Power\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eWa\u003c\/strong\u003e should be taken as 4 times the Running Power \u003cstrong\u003eWr\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eSwitched Mode Power Supplies (SMPS) that do not have Power Factor correction draw a non linear, pulsing current with a high Crest Factor (Ratio of instantaneous value and the RMS value) that may reach a value of 4. Also, the effective Power Factor of these types of power supplies is very low around 0.6. If the inverter is sized based on the Running Power of these units, the inverter will be continuously overloaded from instant to instant due to the higher peaks of the pulsing current. The inverter for these units should be sized at 3 times the Running Power of the power supply. Alternatively, for sizing purposes, the Additional Continuous Power \u003cstrong\u003eWa\u003c\/strong\u003e should be taken as 2 times the Running Power \u003cstrong\u003eWr\u003c\/strong\u003e. Consumer electronics like computers, TV, VCR, audio\/ video devices, etc. use this type of power supply.\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e(Please note that this sizing is not applicable if the SMPS has Power Factor correction and the Power Factor is around 0.9)\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eMotors used in washing machines have to start under load due to the weight of the clothes, water and the drum. Hence, the Additional Starting Power \u003cstrong\u003eWa\u003c\/strong\u003e should be taken as 2 times the Running Power \u003cstrong\u003eWr\u003c\/strong\u003e. This starting power normally lasts from 2 to 5 seconds.\u003c\/p\u003e\n\u003cp\u003eThe Watt rating of the microwaves normally indicates output cooking power in Watts. As the microwave is not an efficient device, the AC input power in Watts should be taken as 2 times the output cooking power in Watts i.e. the Additional Continuous Power \u003cstrong\u003eWa\u003c\/strong\u003e should be taken as 1 time the Running Power \u003cstrong\u003eWr\u003c\/strong\u003e. Hence, a microwave with 900 Watt cooking power will require an 1800 Watt inverter. \u003cstrong\u003e(If the power rating of the inverter is indicated as the AC input power in Watts, the factor of 2 is not applicable).\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe following symbols and equations are used in the sizing of an inverter example below:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTotal Running Power of the items selected, Watts – \u003cstrong\u003eWrt\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eHighest Additional Starting Power out of the items selected, Watts – \u003cstrong\u003eWah\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e*Highest power for sizing purpose, Watts – \u003cstrong\u003eWrt + Wah\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003e* It is assumed that only one out of the selected items starts at one time\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003eSince the AC loads rarely start at the same time, the load with the highest Additional Starting Power \u003cstrong\u003eWah\u003c\/strong\u003e has been factored in.\u003c\/p\u003e\n\u003cp\u003eExample:\u003cbr\u003e\u003c\/p\u003e\n\u003ctable id=\"tablepress-15\" class=\"tablepress tablepress-id-15 tablepress-responsive\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"row-1 odd\"\u003e\n\u003cth class=\"column-1\"\u003e\n\u003cp\u003e\u003csmall\u003eDevice \/ Appliance\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/th\u003e\n\u003cth class=\"column-2\"\u003e\n\u003cp\u003e\u003csmall\u003eRunning Power, Wr, Watts\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/th\u003e\n\u003cth class=\"column-3\"\u003e\n\u003cp\u003e\u003csmall\u003eAdditional\u003cbr\u003eStarting Power or Additional Continuous Power *, Wa, Watts\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/th\u003e\n\u003cth class=\"column-4\"\u003e\n\u003cp\u003e\u003csmall\u003eQuantity\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/th\u003e\n\u003cth class=\"column-5\"\u003e\n\u003cp\u003e\u003csmall\u003eExtended\u003cbr\u003eRunning Power, Wt, Watts\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody class=\"row-hover\"\u003e\n\u003ctr class=\"row-2 even\"\u003e\n\u003ctd class=\"column-1\"\u003e\n\u003cp\u003e\u003csmall\u003eRefrigerator – Electric Compressor based\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"column-2\"\u003e\n\u003cp\u003e\u003csmall\u003e200\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"column-3\"\u003e\n\u003cp\u003e\u003csmall\u003e800\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"column-4\"\u003e\n\u003cp\u003e\u003csmall\u003e1\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"column-5\"\u003e\n\u003cp\u003e\u003csmall\u003e200\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"row-3 odd\"\u003e\n\u003ctd class=\"column-1\"\u003e\n\u003cp\u003e\u003csmall\u003eColor TV\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"column-2\"\u003e\n\u003cp\u003e\u003csmall\u003e225\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"column-3\"\u003e\n\u003cp\u003e\u003csmall\u003e450\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"column-4\"\u003e\n\u003cp\u003e\u003csmall\u003e1\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"column-5\"\u003e\n\u003cp\u003e\u003csmall\u003e225\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"row-4 even\"\u003e\n\u003ctd class=\"column-1\"\u003e\n\u003cp\u003e\u003csmall\u003eLaptop Adapter\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"column-2\"\u003e\n\u003cp\u003e\u003csmall\u003e120\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"column-3\"\u003e\n\u003cp\u003e\u003csmall\u003e240\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"column-4\"\u003e\n\u003cp\u003e\u003csmall\u003e1\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"column-5\"\u003e\n\u003cp\u003e\u003csmall\u003e120\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"row-5 odd\"\u003e\n\u003ctd class=\"column-1\"\u003e\n\u003cp\u003e\u003csmall\u003eIncandescent Lamps\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"column-2\"\u003e\n\u003cp\u003e\u003csmall\u003e60\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"column-3\"\u003e\n\u003cp\u003e\u003csmall\u003e0\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"column-4\"\u003e\n\u003cp\u003e\u003csmall\u003e6\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"column-5\"\u003e\n\u003cp\u003e\u003csmall\u003e360\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e*\u003c\/strong\u003e \u003cem\u003eAdditional Continuous Power is applicable to SMPS based loads that have no Power Factor Correction.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003eTotal Extended Running Power, \u003cstrong\u003eWrt\u003c\/strong\u003e = 200 + 225 + 120 + 360 = \u003cstrong\u003e905\u003c\/strong\u003e Watts\u003c\/p\u003e\n\u003cp\u003eHighest Additional Starting Power, \u003cstrong\u003eWah\u003c\/strong\u003e = \u003cstrong\u003e800\u003c\/strong\u003e Watts\u003c\/p\u003e\n\u003cp\u003eHighest Power for sizing the inverter = Total Running Power, \u003cstrong\u003eWrt\u003c\/strong\u003e(905 W) + Highest Additional Starting Power, \u003cstrong\u003eWah\u003c\/strong\u003e (800 W) = \u003cstrong\u003e1705\u003c\/strong\u003e Watts\u003c\/p\u003e\n\u003ch5 class=\"r-faqs--faq-question j-faqs--question\"\u003eWhat are the electrical standards pertaining to DC-AC inverters?\u003c\/h5\u003e\n\u003cdiv class=\"r-faqs--faq-answer j-faqs--answer open\"\u003e\n\u003cmeta charset=\"utf-8\"\u003e\n\u003cp\u003eThe DC input voltage must conform to that of the electrical system and battery bank. 12 volts is recommended for small, simple systems. 24 and 48 volts are the common standards for higher capacities. A higher voltage system carries less current, which makes the system wiring cheaper and easier.\u003c\/p\u003e\n\u003cp\u003eThe inverter’s AC output must conform to the conventional power in the region to run locally available appliances. The standard for AC utility service in North America is 120 and 240 Volts at a frequency of 60 Hertz (cycles per second). In Europe, South America, and most other places, it is 230 volts at 50 Hertz.\u003c\/p\u003e\n\u003ch5 class=\"r-faqs--faq-question j-faqs--question\"\u003eWhat are \"continuous\" and \"surge\" power capacity ratings for DC-AC inverters?\u003c\/h5\u003e\n\u003cdiv class=\"r-faqs--faq j-faqs--single\" id=\"What-are-continuous-and-surge-power-capacity-ratings-for-DC-AC-inverters\"\u003e\n\u003cdiv class=\"r-faqs--faq-answer j-faqs--answer open\"\u003e\n\u003cp\u003eHow much load can an inverter handle? Its power output is rated in Watts.  There are two levels of power rating -a continuous rating and a surge rating. Continuous means the amount of power the inverter can handle for an indefinite period of hours. When an inverter is rated at a certain number of Watts, that number generally refers to its continuous rating. The “surge power” indicates the power to handle instantaneous overload of a few seconds to provide the higher power required to start certain type of devices and appliances.  Resistive types of loads (like incandescent lamps, toaster, coffee maker, electric range, iron etc) do not require extra power to start. Their starting power is the same as their running power.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cspan class=\"r-faqs--faq-toggle s-read-more j-faqs--toggle\"\u003e\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"r-faqs--faq j-faqs--single\"\u003e\n\u003ch5 class=\"r-faqs--faq-question j-faqs--question\"\u003eHow do \"surge power\" electrical loads affect DC-AC inverter operation?\u003c\/h5\u003e\n\u003cp\u003eIf an inverter cannot efficiently feed the surge power, it may simply shut down instead of starting the device. If the inverter’s surge capacity is marginal, its output voltage will dip during the surge. This can cause a dimming of the lights in the house, and will sometimes crash a computer.\u003c\/p\u003e\n\u003cp\u003eAny weakness in the battery and cabling to the inverter will further limit its ability to start a motor. A battery bank that is undersized, in poor condition, or has corroded connections, can be a weak link in the power chain. The inverter cables and the battery interconnect cables must be sized properly. The spike of DC current through these cables is many hundreds of amps at the instant of a motor starting for example.\u003c\/p\u003e\n\u003ch5 class=\"r-faqs--faq-question j-faqs--question\"\u003eHow should I size my DC-AC inverter for loads that require starting surge?\u003c\/h5\u003e\n\u003cdiv class=\"r-faqs--faq j-faqs--single\" id=\"How-should-I-size-my-DC-AC-inverter-for-loads-that-require-starting-surge\"\u003e\n\u003cdiv class=\"r-faqs--faq-answer j-faqs--answer open\"\u003e\n\u003cp\u003eObserve the following guideline to determine the continuous wattage of the inverter for powering loads that require starting surge. (Multiply the running watts of the device\/appliance by the Surge Factor)\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003e\u003cstrong\u003eNOTE:\u003c\/strong\u003e The surge power rating specified for this inverter is valid for duration of less than 1 second. This very short duration may not be sufficient to start motor based loads which may require up to 5 seconds to complete starting process. Hence, for purposes of sizing the inverter, use only the continuous power rating of this inverter.\u003c\/em\u003e\u003c\/p\u003e\n\u003ctable id=\"tablepress-16\" class=\"tablepress tablepress-id-16 tablepress-responsive\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"row-1 odd\"\u003e\n\u003cth class=\"column-1\"\u003e\n\u003cp\u003e\u003csmall\u003eDevice \/ Appliance\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/th\u003e\n\u003cth class=\"column-2\"\u003e\n\u003cp\u003e\u003csmall\u003eSurge Factor\u003cbr\u003e(No. of times the running power rating of the device\/appliance)\u003c\/small\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody class=\"row-hover\"\u003e\n\u003ctr class=\"row-2 even\"\u003e\n\u003ctd class=\"column-1\"\u003e\n\u003cp\u003e\u003csmall\u003eRefrigerator \/ Freezer\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"column-2\"\u003e\n\u003cp\u003e\u003csmall\u003e5\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"row-3 odd\"\u003e\n\u003ctd class=\"column-1\"\u003e\n\u003cp\u003e\u003csmall\u003eAir Compressors\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"column-2\"\u003e\n\u003cp\u003e\u003csmall\u003e4\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"row-4 even\"\u003e\n\u003ctd class=\"column-1\"\u003e\n\u003cp\u003e\u003csmall\u003eDishwasher\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"column-2\"\u003e\n\u003cp\u003e\u003csmall\u003e3\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"row-5 odd\"\u003e\n\u003ctd class=\"column-1\"\u003e\n\u003cp\u003e\u003csmall\u003eSump pump\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"column-2\"\u003e\n\u003cp\u003e\u003csmall\u003e3\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"row-6 even\"\u003e\n\u003ctd class=\"column-1\"\u003e\n\u003cp\u003e\u003csmall\u003eFurnace fans\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"column-2\"\u003e\n\u003cp\u003e\u003csmall\u003e3\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"row-7 odd\"\u003e\n\u003ctd class=\"column-1\"\u003e\n\u003cp\u003e\u003csmall\u003eIndustrial motors\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"column-2\"\u003e\n\u003cp\u003e\u003csmall\u003e3\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"row-8 even\"\u003e\n\u003ctd class=\"column-1\"\u003e\n\u003cp\u003e\u003csmall\u003eCircular saw\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"column-2\"\u003e\n\u003cp\u003e\u003csmall\u003e3\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"row-9 odd\"\u003e\n\u003ctd class=\"column-1\"\u003e\n\u003cp\u003e\u003csmall\u003eBench Grinder\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"column-2\"\u003e\n\u003cp\u003e\u003csmall\u003e3\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"row-10 even\"\u003e\n\u003ctd class=\"column-1\"\u003e\n\u003cp\u003e\u003csmall\u003ePortable diesel \/ kerosene fuel heater\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"column-2\"\u003e\n\u003cp\u003e\u003csmall\u003e2\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cspan class=\"r-faqs--faq-toggle s-read-more j-faqs--toggle\"\u003e\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"r-faqs--faq j-faqs--single\"\u003e\n\u003cdiv class=\"r-faqs--faq j-faqs--single\" id=\"How-should-I-size-my-DC-AC-inverter-to-operate-a-microwave\"\u003e\n\u003ch5 class=\"r-faqs--faq-question j-faqs--question\"\u003eHow should I size my DC-AC inverter to operate a microwave?\u003c\/h5\u003e\n\u003cspan class=\"r-faqs--faq-toggle s-read-more j-faqs--toggle\"\u003e\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"r-faqs--faq j-faqs--single\"\u003e\n\u003cdiv class=\"r-faqs--faq j-faqs--single\" id=\"How-should-I-size-my-DC-AC-inverter-to-operate-a-microwave\"\u003e\n\u003cdiv class=\"r-faqs--faq-answer j-faqs--answer open\"\u003e\n\u003cp\u003eThe power rating of the microwave generally refers to the cooking power. The electrical power consumed by the microwave will be approximately 2 times the cooking power. The “surge power” of the inverter should be 2 times the electrical power (i.e., 4 times the cooking power). Please note that the surge power of the microwave is not as long as the motor load and hence, the surge power of the inverter can be considered to determine adequacy of meeting the starting surge power.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cspan class=\"r-faqs--faq-toggle s-read-more j-faqs--toggle\"\u003e\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"r-faqs--faq j-faqs--single\"\u003e\n\u003ch5 class=\"r-faqs--faq-question j-faqs--question\"\u003eHow should I size my DC-AC inverter to power a water supply pump?\u003c\/h5\u003e\n\u003cp\u003eA water well or pressure pump often places the greatest demand on the inverter. It warrants special consideration. Most pumps draw a very high surge of current during start up. The inverter must have sufficient surge capacity to handle it while running any other loads that may be on. It is important to size an inverter sufficiently, especially to handle the starting surge (If the exact starting rating is not available, the starting surge can be taken as 3 times the normal running rating of the pump). Oversize it still further if you want it to start the pump without causing lights to dim or blink.\u003c\/p\u003e\n\u003cp\u003eIn North America, most pumps (especially submersibles) run on 240 VAC, while smaller appliances and lights use 120 VAC. To obtain 240 VAC from a 120 VAC inverter, use a 120 VAC to 240 VAC transformer. If you do not already have a pump installed, you can get a 120 volt pump if you don’t need more than 1\/2 HP.\u003c\/p\u003e\n\u003ch5 class=\"r-faqs--faq-question j-faqs--question\"\u003eWhat is \"idle power\" in a DC-AC inverter?\u003c\/h5\u003e\n\u003cdiv class=\"r-faqs--faq j-faqs--single\" id=\"What-is-idle-power-in-a-DC-AC-inverter\"\u003e\n\u003cdiv class=\"r-faqs--faq-answer j-faqs--answer open\"\u003e\n\u003cp\u003eIdle power is the consumption of the inverter when it is on, but no loads are running. It is “wasted” power, so if you expect the inverter to be on for many hours during which there is very little load (as in most residential situations), you want this to be as low as possible.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cspan class=\"r-faqs--faq-toggle s-read-more j-faqs--toggle\"\u003e\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"r-faqs--faq j-faqs--single\"\u003e\n\u003ch5 class=\"r-faqs--faq-question j-faqs--question\"\u003eWhat are Phantom and idling loads?\u003c\/h5\u003e\n\u003cp\u003eMost of the modern gadgets draw some power whenever they are plugged in. Some of them use power to do nothing at all. An example is a TV with a remote control. Its electric eye system is on day and night, watching for your signal to turn the screen on. Every appliance with an external wall-plug transformer uses power even when the appliance is turned off. These little loads are called “phantom loads” because their power draw is unexpected, unseen, and easily forgotten.\u003c\/p\u003e\n\u003cp\u003eA similar concern is “idling loads.” These are devices that must be on all the time in order to function when needed. These include smoke detectors, alarm systems, motion detector lights, fax machines, and answering machines. Central heating systems have a transformer in their thermostat circuit that stays on all the time. Cordless (rechargeable) appliances draw power even after their batteries reach a full charge. If in doubt, feel the device. If it’s warm, that indicates wasted energy.\u003c\/p\u003e\n\u003ch5 class=\"r-faqs--faq-question j-faqs--question\"\u003eCan a standard DC-AC inverter be connected in parallel with another AC source\/ DC-AC inverter \/ electrical utility?\u003c\/h5\u003e\n\u003cdiv class=\"r-faqs--faq j-faqs--single\" id=\"Can-a-standard-DC-AC-inverter-be-connected-in-parallel-with-another-AC-source-DC-AC-inverter-electrical-utility\"\u003e\n\u003cdiv class=\"r-faqs--faq-answer j-faqs--answer open\"\u003e\n\u003cp\u003eThe AC output of standard inverters cannot be synchronised with another AC source and hence, it is not suitable for paralleling. The AC output of the inverter should never be connected directly to an electrical breaker panel \/ load center which is also fed from the utility power \/generator. Such a connection may result in parallel operation of the different power sources and AC power from the utility \/ generator will be fed back into the inverter which will instantly damage the output section of the inverter and may also pose a fire and safety hazard.\u003c\/p\u003e\n\u003cp\u003eIf an electrical breaker panel \/ load center is fed from an inverter and this panel is also required to be powered from additional alternate AC sources, the AC power from all the AC sources like the utility \/ generator \/ inverter should first be fed to a manual selector switch and the output of the selector switch should be connected to the electrical breaker panel \/ load center. To prevent possibility of paralleling and severe damage to the inverter, never use a simple jumper cable with a male plug on both ends to connect the AC output of the inverter to a handy wall receptacle in the home\/RV.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cspan class=\"r-faqs--faq-toggle s-read-more j-faqs--toggle\"\u003e\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"r-faqs--faq j-faqs--single\"\u003e\n\u003ch5 class=\"r-faqs--faq-question j-faqs--question\"\u003eHow can DC-AC inverters be connected to multi-wire branch circuits?\u003c\/h5\u003e\n\u003cdiv class=\"r-faqs--faq j-faqs--single\" id=\"How-can-DC-AC-inverters-be-connected-to-multi-wire-branch-circuits\"\u003e\n\u003cdiv class=\"r-faqs--faq-answer j-faqs--answer open\"\u003e\n\u003cp\u003eDo not directly connect the hot side of the inverter to the two hot legs of the 120 \/ 240 VAC electrical breaker panel \/ load centre where multi-wire ( common neutral ) branch circuit wiring method is used for distribution of AC power. This may lead to overloading\/overheating of the neutral conductor and is a risk of fire.\u003c\/p\u003e\n\u003cp\u003eA split phase transformer (isolated or auto-transformer ) of suitable wattage rating ( 25% more than the wattage rating of the inverter ) with primary of 120 VAC and secondary of 120 \/ 240 VAC ( Two 120 VAC split phases 180 degrees apart) should be used. The hot and neutral of the 120 VAC output of the inverter should be fed to the primary of this transformer and the 2 hot outputs (120 VAC split phases ) and the neutral from the secondary of this transformer should be connected to the electrical breaker panel\/ load centre.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cspan class=\"r-faqs--faq-toggle s-read-more j-faqs--toggle\"\u003e\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"r-faqs--faq j-faqs--single\" id=\"How-should-I-size-my-DC-AC-inverter-to-supply-computer-or-printer-loads\"\u003e\n\u003ch5 class=\"r-faqs--faq-question j-faqs--question\"\u003eHow should I size my DC-AC inverter to supply computer or printer loads?\u003c\/h5\u003e\n\u003cdiv class=\"r-faqs--faq j-faqs--single\" id=\"How-should-I-size-my-DC-AC-inverter-to-supply-computer-or-printer-loads\"\u003e\n\u003cdiv class=\"r-faqs--faq-answer j-faqs--answer open\"\u003e\n\u003cp\u003eComputers and Printers generally come with in-built switch-mode power supplies (see \u003ca href=\"https:\/\/samlexamerica.com\/resources-support\/application-notes\/\"\u003eapplication notes\u003c\/a\u003e and \u003ca href=\"https:\/\/samlexamerica.com\/resources-support\/faq\/inverters-powering-direct-embedded-smps\/\"\u003eFAQs on switch mode power supplies (SMPS)\u003c\/a\u003e) that have extremely low power factor on account of the extremely peaky and non-linear nature of the current drawn by them from the AC source. Hence for such loads we recommend using inverters with three times the advertised power consumption of the computer or printer loads.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cspan class=\"r-faqs--faq-toggle s-read-more j-faqs--toggle\"\u003e\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"r-faqs--faq j-faqs--single\"\u003e\n\u003ch5 class=\"r-faqs--faq-question j-faqs--question\"\u003eWhat is the difference between a 12V, 24V and 48V inverter?\u003c\/h5\u003e\n\u003cdiv class=\"o-resource-body\"\u003e\n\u003cdiv class=\"r-faqs j-faqs\"\u003e\n\u003cdiv class=\"r-faqs--container\"\u003e\n\u003cdiv class=\"r-faqs--faqs j-faqs--faqs\"\u003e\n\u003cdiv class=\"r-faqs--faq j-faqs--single\" id=\"What-is-the-difference-between-a-12V-24V-and-48V-inverter\"\u003e\n\u003cdiv class=\"r-faqs--faq-answer j-faqs--answer open\"\u003e\n\u003cp\u003eA 12-V can be fed from a 12V battery or DC supply. Similarly 24V and 48V inverters can be fed from 24V and 48V batteries\/DC power supplies, respectively. Cars usually have 12V batteries. Trucks have 24V batteries.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Samlex America","offers":[{"title":"Default Title","offer_id":50359596810523,"sku":"OGL-67253","price":178.8,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0724\/2026\/2171\/files\/67253XL.jpg?v=1749567218"},{"product_id":"samlex-100w-fully-isolated-dc-dc-converter-4a-9-18v-input-24v-output-idc-100a-24","title":"Samlex 100W Fully Isolated DC-DC Converter - 4A - 9-18V Input - 24V Output [IDC-100A-24]","description":"\u003ch2\u003e\u003cspan style=\"text-decoration: underline;\"\u003eSamlex 100W Fully Isolated DC-DC Converter - 4A - 9-18V Input - 24V Output [IDC-100A-24]\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003eIDC-100 series is a complete line of high efficiency 100 Watt isolated DC-DC converters suitable for applications requiring galvanic isolation between the input and the output. IDC-100A-24 isolated DC-DC converter provides a highly regulated output DC voltage of 24.5 Volts for an input DC voltage range of 9-18 Volts and rated output current of 4 Amps (at 18 Volts input). Features of this isolated DC-DC converter include compact housing, fold-back current limiting and protection against short circuit, overheating, overvoltage and reverse polarity connection. The unit comes with 1\/4” push-on flat blade “quick disconnect” connectors. IDC-100A-24 isolated DC-DC converter is EMI\/EMC compliant and conforms to European standards EN50081-1 (for EMI), EN50082-1 (for EMC) and the European Automotive Directive 95\/54\/CE.\u0026amp;nbsp;\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eFully Isolated\u003c\/li\u003e\n\u003cli\u003eShort Circuit Protected\u003c\/li\u003e\n\u003cli\u003eCurrent Limited\u003c\/li\u003e\n\u003cli\u003eCE Approved\u003c\/li\u003e\n\u003cli\u003e2 Year Warranty\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eProduct Specifications\u003c\/h3\u003e\n\u003ch2\u003e\u003cspan style=\"text-decoration: underline;\"\u003eSamlex 100W Fully Isolated DC-DC Converter - 4A - 9-18V Input - 24V Output [IDC-100A-24] Product Specifications\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eInput: 9.2-18 VDC\u003c\/li\u003e\n\u003cli\u003eOutput: 24 VDC\u003c\/li\u003e\n\u003cli\u003eWatts: 100\u003c\/li\u003e\n\u003cli\u003eAmps: 4 Amps\u003c\/li\u003e\n\u003cli\u003eWeight: 1.2 (lbs)\u003c\/li\u003e\n\u003cli\u003eWeight: 0.54 (kg)\u003c\/li\u003e\n\u003cli\u003eDimensions: 6 x 3.5 x 1.9 (in)\u003c\/li\u003e\n\u003cli\u003eDimensions: 15.2 x 8.9 x 4.8 (cm)\u003c\/li\u003e\n\u003cli\u003eSafety: CE\u003c\/li\u003e\n\u003cli\u003eWarranty: 2 Year Limited\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eEarth moving equipment\u003c\/li\u003e\n\u003cli\u003eHeavy trucks\u003c\/li\u003e\n\u003cli\u003eBuses\u003c\/li\u003e\n\u003cli\u003eMarine vehicles\u003c\/li\u003e\n\u003cli\u003eCB radios\u003c\/li\u003e\n\u003cli\u003e24 Volt lighting systems\u003c\/li\u003e\n\u003cli\u003eAM\/FM sound systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/productimageserver.com\/prop65\/6pt.png\" alt=\"Warning\"\u003e\u003cstrong\u003eWARNING:\u003c\/strong\u003e This product can expose you to chemicals which are known to the State of California to cause cancer, birth defects or other reproductive harm. For more information go to \u003ca href=\"http:\/\/P65Warnings.ca.gov\"\u003eP65Warnings.ca.gov\u003c\/a\u003e.\u003c\/p\u003e\n\u003c!--- cis2:m2lsnZdp ---\u003e\n\u003ch3\u003e\u003cspan\u003eProduct Manual\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/productimageserver.com\/literature\/ownersManual\/67255OM.pdf\" target=\"_blank\"\u003eOwner's Manual (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/productimageserver.com\/literature\/brochure\/67255BR.pdf\" target=\"_blank\"\u003eBrochure (pdf)\u003c\/a\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eProduct Warranty\u003c\/span\u003e\u003c\/h3\u003e\n\u003ch2 class=\"o-product--description\"\u003e3 Years Limited Warranty\u003c\/h2\u003e\n\u003ch3 class=\"o-product--description\"\u003eProduct FAQs\u003c\/h3\u003e\n\u003ch5 class=\"o-product--description\"\u003eWhat is a Pure Sine Wave Inverter?\u003c\/h5\u003e\n\u003cdiv class=\"o-product--description\"\u003eThe output voltage of a sine wave inverter has a sine wave form like the sine wave form of the mains \/ utility voltage. In a sine wave, the voltage rises and falls smoothly with a smoothly changing phase angle and also changes its polarity instantly when it crosses 0 Volts.\n\u003cdiv class=\"r-faqs--faq-answer j-faqs--answer open\"\u003e\n\u003cdiv class=\"r-faqs--faq j-faqs--single\" id=\"What-are-the-advantages-of-Pure-Sine-Wave-inverters\"\u003e\n\u003ch5 class=\"r-faqs--faq-question j-faqs--question\"\u003eWhat are the advantages of Pure Sine Wave inverters?\u003c\/h5\u003e\n\u003cdiv class=\"r-faqs--faq-answer j-faqs--answer open\"\u003e\n\u003cul\u003e\n\u003cli\u003eThe output wave-form is a sine-wave with\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003every low harmonic distortion\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand clean power like utility supplied electricity\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eInductive loads\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003elike microwaves and motors run faster, quieter and cooler\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eReduces audible and electrical noise\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ein fans, fluorescent lights, audio amplifiers, TV, fax and answering machines\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePrevents crashes\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ein computers, weird print outs and glitches in monitors\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cspan class=\"r-faqs--faq-toggle s-read-more j-faqs--toggle\"\u003e\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"r-faqs--faq j-faqs--single\"\u003e\n\u003cdiv class=\"r-faqs--faq j-faqs--single\" id=\"What-is-a-Modified-Sine-Wave-Inverter\"\u003e\n\u003ch5 class=\"r-faqs--faq-question j-faqs--question\"\u003eWhat is a Modified Sine Wave Inverter?\u003c\/h5\u003e\n\u003cdiv class=\"r-faqs--faq-answer j-faqs--answer open\"\u003e\n\u003cp\u003eIn a modified sine wave, the voltage rises and falls abruptly, the phase angle also changes abruptly and it sits at 0 Volts for some time before changing its polarity.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cspan class=\"r-faqs--faq-toggle s-read-more j-faqs--toggle\"\u003e\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"r-faqs--faq j-faqs--single\"\u003e\n\u003ch5 class=\"r-faqs--faq-question j-faqs--question\"\u003eWhat are the advantages of Pure Sine Wave inverters?\u003c\/h5\u003e\n\u003cdiv class=\"r-faqs--faq-answer j-faqs--answer open\"\u003e\n\u003cul\u003e\n\u003cli\u003eThe output wave-form is a sine-wave with\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003every low harmonic distortion\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand clean power like utility supplied electricity\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eInductive loads\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003elike microwaves and motors run faster, quieter and cooler\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eReduces audible and electrical noise\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ein fans, fluorescent lights, audio amplifiers, TV, fax and answering machines\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePrevents crashes\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ein computers, weird print outs and glitches in monitors\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"o-resource-body\"\u003e\n\u003cdiv class=\"r-faqs j-faqs\"\u003e\n\u003cdiv class=\"r-faqs--container\"\u003e\n\u003cdiv class=\"r-faqs--faqs j-faqs--faqs\"\u003e\n\u003cdiv class=\"r-faqs--faq j-faqs--single\" id=\"Which-devices-will-not-function-properly-from-a-Modified-Sine-Wave-Inverter\"\u003e\n\u003ch5 class=\"r-faqs--faq-question j-faqs--question\"\u003eWhich devices will not function properly from a Modified Sine Wave Inverter?\u003c\/h5\u003e\n\u003cdiv class=\"r-faqs--faq-answer j-faqs--answer open\"\u003e\n\u003cp\u003eAny device that uses a control circuitry that senses the phase (for voltage \/ speed control) or instantaneous zero voltage crossing (for timing control) will not work properly from a voltage that has a modified sine wave-form. Also, as the modified sine wave is a form of square wave, it is comprised of multiple sine waves of odd harmonics (multiples) of the fundamental frequency of the modified sine wave. For example, a 60 Hz. modified sine wave will consist of sine waves with odd harmonic frequencies of 3rd (180 Hz), 5th (300 Hz.), 7th (420 Hz.) and so on. The high frequency harmonic content in a modified sine wave produces enhanced radio interference, higher heating effect in motors \/ microwaves and produces overloading due to lowering of the impedance of low frequency filter capacitors \/ power factor improvement capacitors.\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eSome examples of devices that may not work properly with modified sine wave and may also get damaged are given below\u003c\/em\u003e\u003c\/p\u003e\n\u003cul type=\"circle\"\u003e\n\u003cli\u003eLaser printers, photocopiers, magneto-optical hard drives\u003c\/li\u003e\n\u003cli\u003eThe built-in clocks in devices such as clock radios, alarm clocks, coffee makers, bread-makers, VCR, microwave ovens etc may not keep time correctly\u003c\/li\u003e\n\u003cli\u003eOutput voltage control devices like dimmers, ceiling fan \/ motor speed control may not work properly (dimming \/ speed control may not function)\u003c\/li\u003e\n\u003cli\u003eSewing machines with speed \/ microprocessor control\u003c\/li\u003e\n\u003cli\u003eTransformer-less capacitive input powered devices like (i) Razors, flashlights, night-lights, smoke detectors etc (ii) Re-chargers for battery packs used in hand power tools.\u003cspan\u003e \u003c\/span\u003e\u003cem\u003eThese may get damaged. Please check with the manufacturer of these types of devices for suitability\u003c\/em\u003e\n\u003c\/li\u003e\n\u003cli\u003eDevices that use radio frequency signals carried by the AC distribution wiring\u003c\/li\u003e\n\u003cli\u003eSome new furnaces with microprocessor control \/ Oil burner primary controls\u003c\/li\u003e\n\u003cli\u003eHigh intensity discharge (HID) lamps like Metal Halide lamps.\u003cspan\u003e \u003c\/span\u003e\u003cem\u003eThese may get damaged. Please check with the manufacturer of these types of devices for suitability\u003c\/em\u003e\n\u003c\/li\u003e\n\u003cli\u003eSome fluorescent lamps \/ light fixtures that have power factor correction capacitors.\u003cspan\u003e \u003c\/span\u003e\u003cem\u003eThe inverter may shut down indicating overload\u003c\/em\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5 class=\"r-faqs--faq-question j-faqs--question\"\u003eWhat is a DC-AC inverter?\u003c\/h5\u003e\n\u003cp\u003eWhen you plug anything into the wall in your home you are usually “plugging in” to the power-grid provided as a service by your utility company. Your utility company supplies you with alternating current (AC) electricity. AC electricity flows in alternate directions many times per second. AC is used for utility grid service because it is more practical for long distance transmission.\u003c\/p\u003e\n\u003cp\u003eBatteries provide direct current electricity (DC) electricity which flows in a single direction.  DC power is what is used in many electronics in the home like laptops, solar cells, LED bulbs, and electric vehicles.  They usually have built-in converters to take the AC power received from a plug-in and convert it to DC.\u003c\/p\u003e\n\u003cp\u003eAn inverter (converter) acts as a power adapter as it converts DC to AC,  AC to DC, and can also change the voltage. It allows a battery-based system to run conventional AC appliances directly or through conventional home wiring.\u003c\/p\u003e\n\u003ch5 class=\"r-faqs--faq-question j-faqs--question\"\u003eWhat are the criteria for selecting the right inverter for a particular application?\u003c\/h5\u003e\n\u003cdiv id=\"What-are-the-criteria-for-selecting-the-right-inverter-for-a-particular-application\" class=\"r-faqs--faq j-faqs--single\"\u003e\n\u003cdiv class=\"r-faqs--faq-answer j-faqs--answer open\"\u003e\n\u003cp\u003eTo choose an inverter; you should first define your needs. Where is the inverter to be used? Inverters are available for use in buildings (including homes), for recreational vehicles, boats, and portable applications. Will it be connected to the utility grid in some way? Electrical conventions and safety standards differ for various applications, so don’t improvise.\u003c\/p\u003e\n\u003cp\u003eWhen sizing an inverter, you need to take into consideration both the\u003cstrong\u003e\u003cem\u003e\u003cspan\u003e \u003c\/span\u003erunning power\u003c\/em\u003e\u003c\/strong\u003e \u003cspan\u003e \u003c\/span\u003e\u003cem\u003e\u003cstrong\u003e(continuous)\u003c\/strong\u003e\u003c\/em\u003e\u003cspan\u003e \u003c\/span\u003eand the additional\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e\u003cem\u003estarting surge power\u003c\/em\u003e\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003erequirements of the AC side loads.\u003c\/p\u003e\n\u003cp\u003eSome loads require much higher starting surge power for the first few seconds before settling down at the running power. The inverter should be sized on the basis of the starting surge power of the AC side load. The total starting surge power is equal to the normal running power plus the additional starting power. The following symbols and equation will be used for explanation purposes:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eRunning Power, Watts – \u003cstrong\u003eWr\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eAdditional Starting Power or Additional Continuous Power, Watts – \u003cstrong\u003eWa\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eTotal Starting Surge Power, Watts = Running Power (\u003cstrong\u003eWr\u003c\/strong\u003e) + Additional Starting Power \/ Additional Continuous Power (\u003cstrong\u003eWa\u003c\/strong\u003e)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe specifications of inverters may include a rating termed Surge Power. Normally, the duration of this Surge Power rating is not quantified in the specifications and is assumed to last for less than 1 second. Unless the Surge Power Rating of the inverter is specified to last for \u0026gt; 5 seconds, this Surge Power specification of the inverter should not be considered for purposes of sizing loads with high and prolonged starting surge power.\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eOnly the Continuous Power rating of the inverter should be considered in such cases\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eElectric motor driven compressor\/pump based loads like refrigerators\/freezers, air conditioners, air compressors, sump and well pumps, etc. require a very high Starting Surge Power of around 5 to 7 times the Running Power for the initial start up. This Starting Surge Power may last for 2 to 5 seconds.  The Additional Starting Power\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eWa\u003c\/strong\u003e should be taken as 4 times the Running Power \u003cstrong\u003eWr\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eSwitched Mode Power Supplies (SMPS) that do not have Power Factor correction draw a non linear, pulsing current with a high Crest Factor (Ratio of instantaneous value and the RMS value) that may reach a value of 4. Also, the effective Power Factor of these types of power supplies is very low around 0.6. If the inverter is sized based on the Running Power of these units, the inverter will be continuously overloaded from instant to instant due to the higher peaks of the pulsing current. The inverter for these units should be sized at 3 times the Running Power of the power supply. Alternatively, for sizing purposes, the Additional Continuous Power \u003cstrong\u003eWa\u003c\/strong\u003e should be taken as 2 times the Running Power \u003cstrong\u003eWr\u003c\/strong\u003e. Consumer electronics like computers, TV, VCR, audio\/ video devices, etc. use this type of power supply.\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e(Please note that this sizing is not applicable if the SMPS has Power Factor correction and the Power Factor is around 0.9)\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eMotors used in washing machines have to start under load due to the weight of the clothes, water and the drum. Hence, the Additional Starting Power \u003cstrong\u003eWa\u003c\/strong\u003e should be taken as 2 times the Running Power \u003cstrong\u003eWr\u003c\/strong\u003e. This starting power normally lasts from 2 to 5 seconds.\u003c\/p\u003e\n\u003cp\u003eThe Watt rating of the microwaves normally indicates output cooking power in Watts. As the microwave is not an efficient device, the AC input power in Watts should be taken as 2 times the output cooking power in Watts i.e. the Additional Continuous Power \u003cstrong\u003eWa\u003c\/strong\u003e should be taken as 1 time the Running Power \u003cstrong\u003eWr\u003c\/strong\u003e. Hence, a microwave with 900 Watt cooking power will require an 1800 Watt inverter. \u003cstrong\u003e(If the power rating of the inverter is indicated as the AC input power in Watts, the factor of 2 is not applicable).\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe following symbols and equations are used in the sizing of an inverter example below:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTotal Running Power of the items selected, Watts – \u003cstrong\u003eWrt\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eHighest Additional Starting Power out of the items selected, Watts – \u003cstrong\u003eWah\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e*Highest power for sizing purpose, Watts – \u003cstrong\u003eWrt + Wah\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003e* It is assumed that only one out of the selected items starts at one time\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003eSince the AC loads rarely start at the same time, the load with the highest Additional Starting Power \u003cstrong\u003eWah\u003c\/strong\u003e has been factored in.\u003c\/p\u003e\n\u003cp\u003eExample:\u003cbr\u003e\u003c\/p\u003e\n\u003ctable class=\"tablepress tablepress-id-15 tablepress-responsive\" id=\"tablepress-15\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"row-1 odd\"\u003e\n\u003cth class=\"column-1\"\u003e\n\u003cp\u003e\u003csmall\u003eDevice \/ Appliance\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/th\u003e\n\u003cth class=\"column-2\"\u003e\n\u003cp\u003e\u003csmall\u003eRunning Power, Wr, Watts\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/th\u003e\n\u003cth class=\"column-3\"\u003e\n\u003cp\u003e\u003csmall\u003eAdditional\u003cbr\u003eStarting Power or Additional Continuous Power *, Wa, Watts\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/th\u003e\n\u003cth class=\"column-4\"\u003e\n\u003cp\u003e\u003csmall\u003eQuantity\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/th\u003e\n\u003cth class=\"column-5\"\u003e\n\u003cp\u003e\u003csmall\u003eExtended\u003cbr\u003eRunning Power, Wt, Watts\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody class=\"row-hover\"\u003e\n\u003ctr class=\"row-2 even\"\u003e\n\u003ctd class=\"column-1\"\u003e\n\u003cp\u003e\u003csmall\u003eRefrigerator – Electric Compressor based\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"column-2\"\u003e\n\u003cp\u003e\u003csmall\u003e200\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"column-3\"\u003e\n\u003cp\u003e\u003csmall\u003e800\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"column-4\"\u003e\n\u003cp\u003e\u003csmall\u003e1\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"column-5\"\u003e\n\u003cp\u003e\u003csmall\u003e200\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"row-3 odd\"\u003e\n\u003ctd class=\"column-1\"\u003e\n\u003cp\u003e\u003csmall\u003eColor TV\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"column-2\"\u003e\n\u003cp\u003e\u003csmall\u003e225\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"column-3\"\u003e\n\u003cp\u003e\u003csmall\u003e450\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"column-4\"\u003e\n\u003cp\u003e\u003csmall\u003e1\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"column-5\"\u003e\n\u003cp\u003e\u003csmall\u003e225\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"row-4 even\"\u003e\n\u003ctd class=\"column-1\"\u003e\n\u003cp\u003e\u003csmall\u003eLaptop Adapter\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"column-2\"\u003e\n\u003cp\u003e\u003csmall\u003e120\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"column-3\"\u003e\n\u003cp\u003e\u003csmall\u003e240\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"column-4\"\u003e\n\u003cp\u003e\u003csmall\u003e1\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"column-5\"\u003e\n\u003cp\u003e\u003csmall\u003e120\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"row-5 odd\"\u003e\n\u003ctd class=\"column-1\"\u003e\n\u003cp\u003e\u003csmall\u003eIncandescent Lamps\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"column-2\"\u003e\n\u003cp\u003e\u003csmall\u003e60\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"column-3\"\u003e\n\u003cp\u003e\u003csmall\u003e0\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"column-4\"\u003e\n\u003cp\u003e\u003csmall\u003e6\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"column-5\"\u003e\n\u003cp\u003e\u003csmall\u003e360\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e*\u003c\/strong\u003e \u003cem\u003eAdditional Continuous Power is applicable to SMPS based loads that have no Power Factor Correction.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003eTotal Extended Running Power, \u003cstrong\u003eWrt\u003c\/strong\u003e = 200 + 225 + 120 + 360 = \u003cstrong\u003e905\u003c\/strong\u003e Watts\u003c\/p\u003e\n\u003cp\u003eHighest Additional Starting Power, \u003cstrong\u003eWah\u003c\/strong\u003e = \u003cstrong\u003e800\u003c\/strong\u003e Watts\u003c\/p\u003e\n\u003cp\u003eHighest Power for sizing the inverter = Total Running Power, \u003cstrong\u003eWrt\u003c\/strong\u003e(905 W) + Highest Additional Starting Power, \u003cstrong\u003eWah\u003c\/strong\u003e (800 W) = \u003cstrong\u003e1705\u003c\/strong\u003e Watts\u003c\/p\u003e\n\u003ch5 class=\"r-faqs--faq-question j-faqs--question\"\u003eWhat are the electrical standards pertaining to DC-AC inverters?\u003c\/h5\u003e\n\u003cdiv class=\"r-faqs--faq-answer j-faqs--answer open\"\u003e\n\u003cmeta charset=\"utf-8\"\u003e\n\u003cp\u003eThe DC input voltage must conform to that of the electrical system and battery bank. 12 volts is recommended for small, simple systems. 24 and 48 volts are the common standards for higher capacities. A higher voltage system carries less current, which makes the system wiring cheaper and easier.\u003c\/p\u003e\n\u003cp\u003eThe inverter’s AC output must conform to the conventional power in the region to run locally available appliances. The standard for AC utility service in North America is 120 and 240 Volts at a frequency of 60 Hertz (cycles per second). In Europe, South America, and most other places, it is 230 volts at 50 Hertz.\u003c\/p\u003e\n\u003ch5 class=\"r-faqs--faq-question j-faqs--question\"\u003eWhat are \"continuous\" and \"surge\" power capacity ratings for DC-AC inverters?\u003c\/h5\u003e\n\u003cdiv id=\"What-are-continuous-and-surge-power-capacity-ratings-for-DC-AC-inverters\" class=\"r-faqs--faq j-faqs--single\"\u003e\n\u003cdiv class=\"r-faqs--faq-answer j-faqs--answer open\"\u003e\n\u003cp\u003eHow much load can an inverter handle? Its power output is rated in Watts.  There are two levels of power rating -a continuous rating and a surge rating. Continuous means the amount of power the inverter can handle for an indefinite period of hours. When an inverter is rated at a certain number of Watts, that number generally refers to its continuous rating. The “surge power” indicates the power to handle instantaneous overload of a few seconds to provide the higher power required to start certain type of devices and appliances.  Resistive types of loads (like incandescent lamps, toaster, coffee maker, electric range, iron etc) do not require extra power to start. Their starting power is the same as their running power.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cspan class=\"r-faqs--faq-toggle s-read-more j-faqs--toggle\"\u003e\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"r-faqs--faq j-faqs--single\"\u003e\n\u003ch5 class=\"r-faqs--faq-question j-faqs--question\"\u003eHow do \"surge power\" electrical loads affect DC-AC inverter operation?\u003c\/h5\u003e\n\u003cp\u003eIf an inverter cannot efficiently feed the surge power, it may simply shut down instead of starting the device. If the inverter’s surge capacity is marginal, its output voltage will dip during the surge. This can cause a dimming of the lights in the house, and will sometimes crash a computer.\u003c\/p\u003e\n\u003cp\u003eAny weakness in the battery and cabling to the inverter will further limit its ability to start a motor. A battery bank that is undersized, in poor condition, or has corroded connections, can be a weak link in the power chain. The inverter cables and the battery interconnect cables must be sized properly. The spike of DC current through these cables is many hundreds of amps at the instant of a motor starting for example.\u003c\/p\u003e\n\u003ch5 class=\"r-faqs--faq-question j-faqs--question\"\u003eHow should I size my DC-AC inverter for loads that require starting surge?\u003c\/h5\u003e\n\u003cdiv id=\"How-should-I-size-my-DC-AC-inverter-for-loads-that-require-starting-surge\" class=\"r-faqs--faq j-faqs--single\"\u003e\n\u003cdiv class=\"r-faqs--faq-answer j-faqs--answer open\"\u003e\n\u003cp\u003eObserve the following guideline to determine the continuous wattage of the inverter for powering loads that require starting surge. (Multiply the running watts of the device\/appliance by the Surge Factor)\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003e\u003cstrong\u003eNOTE:\u003c\/strong\u003e The surge power rating specified for this inverter is valid for duration of less than 1 second. This very short duration may not be sufficient to start motor based loads which may require up to 5 seconds to complete starting process. Hence, for purposes of sizing the inverter, use only the continuous power rating of this inverter.\u003c\/em\u003e\u003c\/p\u003e\n\u003ctable class=\"tablepress tablepress-id-16 tablepress-responsive\" id=\"tablepress-16\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"row-1 odd\"\u003e\n\u003cth class=\"column-1\"\u003e\n\u003cp\u003e\u003csmall\u003eDevice \/ Appliance\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/th\u003e\n\u003cth class=\"column-2\"\u003e\n\u003cp\u003e\u003csmall\u003eSurge Factor\u003cbr\u003e(No. of times the running power rating of the device\/appliance)\u003c\/small\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody class=\"row-hover\"\u003e\n\u003ctr class=\"row-2 even\"\u003e\n\u003ctd class=\"column-1\"\u003e\n\u003cp\u003e\u003csmall\u003eRefrigerator \/ Freezer\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"column-2\"\u003e\n\u003cp\u003e\u003csmall\u003e5\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"row-3 odd\"\u003e\n\u003ctd class=\"column-1\"\u003e\n\u003cp\u003e\u003csmall\u003eAir Compressors\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"column-2\"\u003e\n\u003cp\u003e\u003csmall\u003e4\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"row-4 even\"\u003e\n\u003ctd class=\"column-1\"\u003e\n\u003cp\u003e\u003csmall\u003eDishwasher\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"column-2\"\u003e\n\u003cp\u003e\u003csmall\u003e3\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"row-5 odd\"\u003e\n\u003ctd class=\"column-1\"\u003e\n\u003cp\u003e\u003csmall\u003eSump pump\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"column-2\"\u003e\n\u003cp\u003e\u003csmall\u003e3\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"row-6 even\"\u003e\n\u003ctd class=\"column-1\"\u003e\n\u003cp\u003e\u003csmall\u003eFurnace fans\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"column-2\"\u003e\n\u003cp\u003e\u003csmall\u003e3\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"row-7 odd\"\u003e\n\u003ctd class=\"column-1\"\u003e\n\u003cp\u003e\u003csmall\u003eIndustrial motors\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"column-2\"\u003e\n\u003cp\u003e\u003csmall\u003e3\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"row-8 even\"\u003e\n\u003ctd class=\"column-1\"\u003e\n\u003cp\u003e\u003csmall\u003eCircular saw\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"column-2\"\u003e\n\u003cp\u003e\u003csmall\u003e3\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"row-9 odd\"\u003e\n\u003ctd class=\"column-1\"\u003e\n\u003cp\u003e\u003csmall\u003eBench Grinder\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"column-2\"\u003e\n\u003cp\u003e\u003csmall\u003e3\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"row-10 even\"\u003e\n\u003ctd class=\"column-1\"\u003e\n\u003cp\u003e\u003csmall\u003ePortable diesel \/ kerosene fuel heater\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"column-2\"\u003e\n\u003cp\u003e\u003csmall\u003e2\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cspan class=\"r-faqs--faq-toggle s-read-more j-faqs--toggle\"\u003e\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"r-faqs--faq j-faqs--single\"\u003e\n\u003cdiv id=\"How-should-I-size-my-DC-AC-inverter-to-operate-a-microwave\" class=\"r-faqs--faq j-faqs--single\"\u003e\n\u003ch5 class=\"r-faqs--faq-question j-faqs--question\"\u003eHow should I size my DC-AC inverter to operate a microwave?\u003c\/h5\u003e\n\u003cspan class=\"r-faqs--faq-toggle s-read-more j-faqs--toggle\"\u003e\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"r-faqs--faq j-faqs--single\"\u003e\n\u003cdiv id=\"How-should-I-size-my-DC-AC-inverter-to-operate-a-microwave\" class=\"r-faqs--faq j-faqs--single\"\u003e\n\u003cdiv class=\"r-faqs--faq-answer j-faqs--answer open\"\u003e\n\u003cp\u003eThe power rating of the microwave generally refers to the cooking power. The electrical power consumed by the microwave will be approximately 2 times the cooking power. The “surge power” of the inverter should be 2 times the electrical power (i.e., 4 times the cooking power). Please note that the surge power of the microwave is not as long as the motor load and hence, the surge power of the inverter can be considered to determine adequacy of meeting the starting surge power.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cspan class=\"r-faqs--faq-toggle s-read-more j-faqs--toggle\"\u003e\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"r-faqs--faq j-faqs--single\"\u003e\n\u003ch5 class=\"r-faqs--faq-question j-faqs--question\"\u003eHow should I size my DC-AC inverter to power a water supply pump?\u003c\/h5\u003e\n\u003cp\u003eA water well or pressure pump often places the greatest demand on the inverter. It warrants special consideration. Most pumps draw a very high surge of current during start up. The inverter must have sufficient surge capacity to handle it while running any other loads that may be on. It is important to size an inverter sufficiently, especially to handle the starting surge (If the exact starting rating is not available, the starting surge can be taken as 3 times the normal running rating of the pump). Oversize it still further if you want it to start the pump without causing lights to dim or blink.\u003c\/p\u003e\n\u003cp\u003eIn North America, most pumps (especially submersibles) run on 240 VAC, while smaller appliances and lights use 120 VAC. To obtain 240 VAC from a 120 VAC inverter, use a 120 VAC to 240 VAC transformer. If you do not already have a pump installed, you can get a 120 volt pump if you don’t need more than 1\/2 HP.\u003c\/p\u003e\n\u003ch5 class=\"r-faqs--faq-question j-faqs--question\"\u003eWhat is \"idle power\" in a DC-AC inverter?\u003c\/h5\u003e\n\u003cdiv id=\"What-is-idle-power-in-a-DC-AC-inverter\" class=\"r-faqs--faq j-faqs--single\"\u003e\n\u003cdiv class=\"r-faqs--faq-answer j-faqs--answer open\"\u003e\n\u003cp\u003eIdle power is the consumption of the inverter when it is on, but no loads are running. It is “wasted” power, so if you expect the inverter to be on for many hours during which there is very little load (as in most residential situations), you want this to be as low as possible.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cspan class=\"r-faqs--faq-toggle s-read-more j-faqs--toggle\"\u003e\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"r-faqs--faq j-faqs--single\"\u003e\n\u003ch5 class=\"r-faqs--faq-question j-faqs--question\"\u003eWhat are Phantom and idling loads?\u003c\/h5\u003e\n\u003cp\u003eMost of the modern gadgets draw some power whenever they are plugged in. Some of them use power to do nothing at all. An example is a TV with a remote control. Its electric eye system is on day and night, watching for your signal to turn the screen on. Every appliance with an external wall-plug transformer uses power even when the appliance is turned off. These little loads are called “phantom loads” because their power draw is unexpected, unseen, and easily forgotten.\u003c\/p\u003e\n\u003cp\u003eA similar concern is “idling loads.” These are devices that must be on all the time in order to function when needed. These include smoke detectors, alarm systems, motion detector lights, fax machines, and answering machines. Central heating systems have a transformer in their thermostat circuit that stays on all the time. Cordless (rechargeable) appliances draw power even after their batteries reach a full charge. If in doubt, feel the device. If it’s warm, that indicates wasted energy.\u003c\/p\u003e\n\u003ch5 class=\"r-faqs--faq-question j-faqs--question\"\u003eCan a standard DC-AC inverter be connected in parallel with another AC source\/ DC-AC inverter \/ electrical utility?\u003c\/h5\u003e\n\u003cdiv id=\"Can-a-standard-DC-AC-inverter-be-connected-in-parallel-with-another-AC-source-DC-AC-inverter-electrical-utility\" class=\"r-faqs--faq j-faqs--single\"\u003e\n\u003cdiv class=\"r-faqs--faq-answer j-faqs--answer open\"\u003e\n\u003cp\u003eThe AC output of standard inverters cannot be synchronised with another AC source and hence, it is not suitable for paralleling. The AC output of the inverter should never be connected directly to an electrical breaker panel \/ load center which is also fed from the utility power \/generator. Such a connection may result in parallel operation of the different power sources and AC power from the utility \/ generator will be fed back into the inverter which will instantly damage the output section of the inverter and may also pose a fire and safety hazard.\u003c\/p\u003e\n\u003cp\u003eIf an electrical breaker panel \/ load center is fed from an inverter and this panel is also required to be powered from additional alternate AC sources, the AC power from all the AC sources like the utility \/ generator \/ inverter should first be fed to a manual selector switch and the output of the selector switch should be connected to the electrical breaker panel \/ load center. To prevent possibility of paralleling and severe damage to the inverter, never use a simple jumper cable with a male plug on both ends to connect the AC output of the inverter to a handy wall receptacle in the home\/RV.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cspan class=\"r-faqs--faq-toggle s-read-more j-faqs--toggle\"\u003e\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"r-faqs--faq j-faqs--single\"\u003e\n\u003ch5 class=\"r-faqs--faq-question j-faqs--question\"\u003eHow can DC-AC inverters be connected to multi-wire branch circuits?\u003c\/h5\u003e\n\u003cdiv id=\"How-can-DC-AC-inverters-be-connected-to-multi-wire-branch-circuits\" class=\"r-faqs--faq j-faqs--single\"\u003e\n\u003cdiv class=\"r-faqs--faq-answer j-faqs--answer open\"\u003e\n\u003cp\u003eDo not directly connect the hot side of the inverter to the two hot legs of the 120 \/ 240 VAC electrical breaker panel \/ load centre where multi-wire ( common neutral ) branch circuit wiring method is used for distribution of AC power. This may lead to overloading\/overheating of the neutral conductor and is a risk of fire.\u003c\/p\u003e\n\u003cp\u003eA split phase transformer (isolated or auto-transformer ) of suitable wattage rating ( 25% more than the wattage rating of the inverter ) with primary of 120 VAC and secondary of 120 \/ 240 VAC ( Two 120 VAC split phases 180 degrees apart) should be used. The hot and neutral of the 120 VAC output of the inverter should be fed to the primary of this transformer and the 2 hot outputs (120 VAC split phases ) and the neutral from the secondary of this transformer should be connected to the electrical breaker panel\/ load centre.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cspan class=\"r-faqs--faq-toggle s-read-more j-faqs--toggle\"\u003e\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv id=\"How-should-I-size-my-DC-AC-inverter-to-supply-computer-or-printer-loads\" class=\"r-faqs--faq j-faqs--single\"\u003e\n\u003ch5 class=\"r-faqs--faq-question j-faqs--question\"\u003eHow should I size my DC-AC inverter to supply computer or printer loads?\u003c\/h5\u003e\n\u003cdiv id=\"How-should-I-size-my-DC-AC-inverter-to-supply-computer-or-printer-loads\" class=\"r-faqs--faq j-faqs--single\"\u003e\n\u003cdiv class=\"r-faqs--faq-answer j-faqs--answer open\"\u003e\n\u003cp\u003eComputers and Printers generally come with in-built switch-mode power supplies (see \u003ca href=\"https:\/\/samlexamerica.com\/resources-support\/application-notes\/\"\u003eapplication notes\u003c\/a\u003e and \u003ca href=\"https:\/\/samlexamerica.com\/resources-support\/faq\/inverters-powering-direct-embedded-smps\/\"\u003eFAQs on switch mode power supplies (SMPS)\u003c\/a\u003e) that have extremely low power factor on account of the extremely peaky and non-linear nature of the current drawn by them from the AC source. Hence for such loads we recommend using inverters with three times the advertised power consumption of the computer or printer loads.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cspan class=\"r-faqs--faq-toggle s-read-more j-faqs--toggle\"\u003e\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"r-faqs--faq j-faqs--single\"\u003e\n\u003ch5 class=\"r-faqs--faq-question j-faqs--question\"\u003eWhat is the difference between a 12V, 24V and 48V inverter?\u003c\/h5\u003e\n\u003cdiv class=\"o-resource-body\"\u003e\n\u003cdiv class=\"r-faqs j-faqs\"\u003e\n\u003cdiv class=\"r-faqs--container\"\u003e\n\u003cdiv class=\"r-faqs--faqs j-faqs--faqs\"\u003e\n\u003cdiv id=\"What-is-the-difference-between-a-12V-24V-and-48V-inverter\" class=\"r-faqs--faq j-faqs--single\"\u003e\n\u003cdiv class=\"r-faqs--faq-answer j-faqs--answer open\"\u003e\n\u003cp\u003eA 12-V can be fed from a 12V battery or DC supply. Similarly 24V and 48V inverters can be fed from 24V and 48V batteries\/DC power supplies, respectively. Cars usually have 12V batteries. Trucks have 24V batteries.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Samlex America","offers":[{"title":"Default Title","offer_id":50359596843291,"sku":"OGL-67255","price":178.8,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0724\/2026\/2171\/files\/67255XL.jpg?v=1749567218"},{"product_id":"samlex-step-up-dc-dc-converter-7a-9-18v-input-24v-output-step7","title":"Samlex Step-Up DC-DC Converter - 7A - 9-18V Input - 24V Output [STEP7]","description":"\u003ch2\u003e\u003cspan style=\"text-decoration: underline;\"\u003eSamlex Step-Up DC-DC Converter - 7A - 9-18V Input - 24V Output [STEP7]\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eStep up from 12VDC to 24VDC at 7 Amps DC\u003c\/li\u003e\n\u003cli\u003eSwitch Mode design\u003c\/li\u003e\n\u003cli\u003eCE approved\u003c\/li\u003e\n\u003cli\u003eHigh Efficiency\u003c\/li\u003e\n\u003cli\u003eOver-current protection\u003c\/li\u003e\n\u003cli\u003eOver-voltage, Reverse Polarity protection\u003c\/li\u003e\n\u003cli\u003e6.3 mm push-on flat pin connectors\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eProduct Specifications\u003c\/h3\u003e\n\u003ch2\u003e\u003cspan style=\"text-decoration: underline;\"\u003eSamlex Step-Up DC-DC Converter - 7A - 9-18V Input - 24V Output [STEP7] Product Specifications\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eInput: 9-18 VDC\u003c\/li\u003e\n\u003cli\u003eOutput: 24 VDC\u003c\/li\u003e\n\u003cli\u003eAmps: 7 Amps\u003c\/li\u003e\n\u003cli\u003eWeight: 0.8 (lbs)\u003c\/li\u003e\n\u003cli\u003eWeight: 0.36 (kg)\u003c\/li\u003e\n\u003cli\u003eDimensions: 5 x 3.5 x 2 (in)\u003c\/li\u003e\n\u003cli\u003eDimensions: 12.7 x 8.9 x 5.1 (cm)\u003c\/li\u003e\n\u003cli\u003eSafety: CE\u003c\/li\u003e\n\u003cli\u003eWarranty: 2 Year Limited\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eIndustrial\u003c\/li\u003e\n\u003cli\u003eCommercial\u003c\/li\u003e\n\u003cli\u003eOEM\u003c\/li\u003e\n\u003cli\u003eRecreational\u003c\/li\u003e\n\u003cli\u003eMarine\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cimg alt=\"Warning\" src=\"https:\/\/productimageserver.com\/prop65\/6pt.png\"\u003e\u003cstrong\u003eWARNING:\u003c\/strong\u003e This product can expose you to chemicals which are known to the State of California to cause cancer, birth defects or other reproductive harm. For more information go to \u003ca href=\"http:\/\/P65Warnings.ca.gov\"\u003eP65Warnings.ca.gov\u003c\/a\u003e.\u003c\/p\u003e\n\u003c!--- cis2:m2lsnZdp ---\u003e\n\u003ch3\u003e\u003cspan\u003eProduct Manual\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/productimageserver.com\/literature\/ownersManual\/67271OM.pdf\" target=\"_blank\"\u003eOwner's Manual (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/productimageserver.com\/literature\/brochure\/67271BR.pdf\" target=\"_blank\"\u003eBrochure (pdf)\u003c\/a\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eProduct Warranty\u003c\/span\u003e\u003c\/h3\u003e\n\u003ch2 class=\"o-product--description\"\u003e3 Years Limited Warranty\u003c\/h2\u003e\n\u003ch3 class=\"o-product--description\"\u003eProduct FAQs\u003c\/h3\u003e\n\u003ch5 class=\"o-product--description\"\u003eWhat is a Pure Sine Wave Inverter?\u003c\/h5\u003e\n\u003cdiv class=\"o-product--description\"\u003eThe output voltage of a sine wave inverter has a sine wave form like the sine wave form of the mains \/ utility voltage. In a sine wave, the voltage rises and falls smoothly with a smoothly changing phase angle and also changes its polarity instantly when it crosses 0 Volts.\n\u003cdiv class=\"r-faqs--faq-answer j-faqs--answer open\"\u003e\n\u003cdiv class=\"r-faqs--faq j-faqs--single\" id=\"What-are-the-advantages-of-Pure-Sine-Wave-inverters\"\u003e\n\u003ch5 class=\"r-faqs--faq-question j-faqs--question\"\u003eWhat are the advantages of Pure Sine Wave inverters?\u003c\/h5\u003e\n\u003cdiv class=\"r-faqs--faq-answer j-faqs--answer open\"\u003e\n\u003cul\u003e\n\u003cli\u003eThe output wave-form is a sine-wave with\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003every low harmonic distortion\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand clean power like utility supplied electricity\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eInductive loads\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003elike microwaves and motors run faster, quieter and cooler\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eReduces audible and electrical noise\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ein fans, fluorescent lights, audio amplifiers, TV, fax and answering machines\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePrevents crashes\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ein computers, weird print outs and glitches in monitors\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cspan class=\"r-faqs--faq-toggle s-read-more j-faqs--toggle\"\u003e\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"r-faqs--faq j-faqs--single\"\u003e\n\u003cdiv class=\"r-faqs--faq j-faqs--single\" id=\"What-is-a-Modified-Sine-Wave-Inverter\"\u003e\n\u003ch5 class=\"r-faqs--faq-question j-faqs--question\"\u003eWhat is a Modified Sine Wave Inverter?\u003c\/h5\u003e\n\u003cdiv class=\"r-faqs--faq-answer j-faqs--answer open\"\u003e\n\u003cp\u003eIn a modified sine wave, the voltage rises and falls abruptly, the phase angle also changes abruptly and it sits at 0 Volts for some time before changing its polarity.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cspan class=\"r-faqs--faq-toggle s-read-more j-faqs--toggle\"\u003e\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"r-faqs--faq j-faqs--single\"\u003e\n\u003ch5 class=\"r-faqs--faq-question j-faqs--question\"\u003eWhat are the advantages of Pure Sine Wave inverters?\u003c\/h5\u003e\n\u003cdiv class=\"r-faqs--faq-answer j-faqs--answer open\"\u003e\n\u003cul\u003e\n\u003cli\u003eThe output wave-form is a sine-wave with\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003every low harmonic distortion\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand clean power like utility supplied electricity\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eInductive loads\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003elike microwaves and motors run faster, quieter and cooler\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eReduces audible and electrical noise\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ein fans, fluorescent lights, audio amplifiers, TV, fax and answering machines\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePrevents crashes\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ein computers, weird print outs and glitches in monitors\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"o-resource-body\"\u003e\n\u003cdiv class=\"r-faqs j-faqs\"\u003e\n\u003cdiv class=\"r-faqs--container\"\u003e\n\u003cdiv class=\"r-faqs--faqs j-faqs--faqs\"\u003e\n\u003cdiv class=\"r-faqs--faq j-faqs--single\" id=\"Which-devices-will-not-function-properly-from-a-Modified-Sine-Wave-Inverter\"\u003e\n\u003ch5 class=\"r-faqs--faq-question j-faqs--question\"\u003eWhich devices will not function properly from a Modified Sine Wave Inverter?\u003c\/h5\u003e\n\u003cdiv class=\"r-faqs--faq-answer j-faqs--answer open\"\u003e\n\u003cp\u003eAny device that uses a control circuitry that senses the phase (for voltage \/ speed control) or instantaneous zero voltage crossing (for timing control) will not work properly from a voltage that has a modified sine wave-form. Also, as the modified sine wave is a form of square wave, it is comprised of multiple sine waves of odd harmonics (multiples) of the fundamental frequency of the modified sine wave. For example, a 60 Hz. modified sine wave will consist of sine waves with odd harmonic frequencies of 3rd (180 Hz), 5th (300 Hz.), 7th (420 Hz.) and so on. The high frequency harmonic content in a modified sine wave produces enhanced radio interference, higher heating effect in motors \/ microwaves and produces overloading due to lowering of the impedance of low frequency filter capacitors \/ power factor improvement capacitors.\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eSome examples of devices that may not work properly with modified sine wave and may also get damaged are given below\u003c\/em\u003e\u003c\/p\u003e\n\u003cul type=\"circle\"\u003e\n\u003cli\u003eLaser printers, photocopiers, magneto-optical hard drives\u003c\/li\u003e\n\u003cli\u003eThe built-in clocks in devices such as clock radios, alarm clocks, coffee makers, bread-makers, VCR, microwave ovens etc may not keep time correctly\u003c\/li\u003e\n\u003cli\u003eOutput voltage control devices like dimmers, ceiling fan \/ motor speed control may not work properly (dimming \/ speed control may not function)\u003c\/li\u003e\n\u003cli\u003eSewing machines with speed \/ microprocessor control\u003c\/li\u003e\n\u003cli\u003eTransformer-less capacitive input powered devices like (i) Razors, flashlights, night-lights, smoke detectors etc (ii) Re-chargers for battery packs used in hand power tools.\u003cspan\u003e \u003c\/span\u003e\u003cem\u003eThese may get damaged. Please check with the manufacturer of these types of devices for suitability\u003c\/em\u003e\n\u003c\/li\u003e\n\u003cli\u003eDevices that use radio frequency signals carried by the AC distribution wiring\u003c\/li\u003e\n\u003cli\u003eSome new furnaces with microprocessor control \/ Oil burner primary controls\u003c\/li\u003e\n\u003cli\u003eHigh intensity discharge (HID) lamps like Metal Halide lamps.\u003cspan\u003e \u003c\/span\u003e\u003cem\u003eThese may get damaged. Please check with the manufacturer of these types of devices for suitability\u003c\/em\u003e\n\u003c\/li\u003e\n\u003cli\u003eSome fluorescent lamps \/ light fixtures that have power factor correction capacitors.\u003cspan\u003e \u003c\/span\u003e\u003cem\u003eThe inverter may shut down indicating overload\u003c\/em\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5 class=\"r-faqs--faq-question j-faqs--question\"\u003eWhat is a DC-AC inverter?\u003c\/h5\u003e\n\u003cp\u003eWhen you plug anything into the wall in your home you are usually “plugging in” to the power-grid provided as a service by your utility company. Your utility company supplies you with alternating current (AC) electricity. AC electricity flows in alternate directions many times per second. AC is used for utility grid service because it is more practical for long distance transmission.\u003c\/p\u003e\n\u003cp\u003eBatteries provide direct current electricity (DC) electricity which flows in a single direction.  DC power is what is used in many electronics in the home like laptops, solar cells, LED bulbs, and electric vehicles.  They usually have built-in converters to take the AC power received from a plug-in and convert it to DC.\u003c\/p\u003e\n\u003cp\u003eAn inverter (converter) acts as a power adapter as it converts DC to AC,  AC to DC, and can also change the voltage. It allows a battery-based system to run conventional AC appliances directly or through conventional home wiring.\u003c\/p\u003e\n\u003ch5 class=\"r-faqs--faq-question j-faqs--question\"\u003eWhat are the criteria for selecting the right inverter for a particular application?\u003c\/h5\u003e\n\u003cdiv id=\"What-are-the-criteria-for-selecting-the-right-inverter-for-a-particular-application\" class=\"r-faqs--faq j-faqs--single\"\u003e\n\u003cdiv class=\"r-faqs--faq-answer j-faqs--answer open\"\u003e\n\u003cp\u003eTo choose an inverter; you should first define your needs. Where is the inverter to be used? Inverters are available for use in buildings (including homes), for recreational vehicles, boats, and portable applications. Will it be connected to the utility grid in some way? Electrical conventions and safety standards differ for various applications, so don’t improvise.\u003c\/p\u003e\n\u003cp\u003eWhen sizing an inverter, you need to take into consideration both the\u003cstrong\u003e\u003cem\u003e\u003cspan\u003e \u003c\/span\u003erunning power\u003c\/em\u003e\u003c\/strong\u003e \u003cspan\u003e \u003c\/span\u003e\u003cem\u003e\u003cstrong\u003e(continuous)\u003c\/strong\u003e\u003c\/em\u003e\u003cspan\u003e \u003c\/span\u003eand the additional\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e\u003cem\u003estarting surge power\u003c\/em\u003e\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003erequirements of the AC side loads.\u003c\/p\u003e\n\u003cp\u003eSome loads require much higher starting surge power for the first few seconds before settling down at the running power. The inverter should be sized on the basis of the starting surge power of the AC side load. The total starting surge power is equal to the normal running power plus the additional starting power. The following symbols and equation will be used for explanation purposes:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eRunning Power, Watts – \u003cstrong\u003eWr\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eAdditional Starting Power or Additional Continuous Power, Watts – \u003cstrong\u003eWa\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eTotal Starting Surge Power, Watts = Running Power (\u003cstrong\u003eWr\u003c\/strong\u003e) + Additional Starting Power \/ Additional Continuous Power (\u003cstrong\u003eWa\u003c\/strong\u003e)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe specifications of inverters may include a rating termed Surge Power. Normally, the duration of this Surge Power rating is not quantified in the specifications and is assumed to last for less than 1 second. Unless the Surge Power Rating of the inverter is specified to last for \u0026gt; 5 seconds, this Surge Power specification of the inverter should not be considered for purposes of sizing loads with high and prolonged starting surge power.\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eOnly the Continuous Power rating of the inverter should be considered in such cases\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eElectric motor driven compressor\/pump based loads like refrigerators\/freezers, air conditioners, air compressors, sump and well pumps, etc. require a very high Starting Surge Power of around 5 to 7 times the Running Power for the initial start up. This Starting Surge Power may last for 2 to 5 seconds.  The Additional Starting Power\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eWa\u003c\/strong\u003e should be taken as 4 times the Running Power \u003cstrong\u003eWr\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eSwitched Mode Power Supplies (SMPS) that do not have Power Factor correction draw a non linear, pulsing current with a high Crest Factor (Ratio of instantaneous value and the RMS value) that may reach a value of 4. Also, the effective Power Factor of these types of power supplies is very low around 0.6. If the inverter is sized based on the Running Power of these units, the inverter will be continuously overloaded from instant to instant due to the higher peaks of the pulsing current. The inverter for these units should be sized at 3 times the Running Power of the power supply. Alternatively, for sizing purposes, the Additional Continuous Power \u003cstrong\u003eWa\u003c\/strong\u003e should be taken as 2 times the Running Power \u003cstrong\u003eWr\u003c\/strong\u003e. Consumer electronics like computers, TV, VCR, audio\/ video devices, etc. use this type of power supply.\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e(Please note that this sizing is not applicable if the SMPS has Power Factor correction and the Power Factor is around 0.9)\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eMotors used in washing machines have to start under load due to the weight of the clothes, water and the drum. Hence, the Additional Starting Power \u003cstrong\u003eWa\u003c\/strong\u003e should be taken as 2 times the Running Power \u003cstrong\u003eWr\u003c\/strong\u003e. This starting power normally lasts from 2 to 5 seconds.\u003c\/p\u003e\n\u003cp\u003eThe Watt rating of the microwaves normally indicates output cooking power in Watts. As the microwave is not an efficient device, the AC input power in Watts should be taken as 2 times the output cooking power in Watts i.e. the Additional Continuous Power \u003cstrong\u003eWa\u003c\/strong\u003e should be taken as 1 time the Running Power \u003cstrong\u003eWr\u003c\/strong\u003e. Hence, a microwave with 900 Watt cooking power will require an 1800 Watt inverter. \u003cstrong\u003e(If the power rating of the inverter is indicated as the AC input power in Watts, the factor of 2 is not applicable).\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe following symbols and equations are used in the sizing of an inverter example below:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTotal Running Power of the items selected, Watts – \u003cstrong\u003eWrt\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eHighest Additional Starting Power out of the items selected, Watts – \u003cstrong\u003eWah\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e*Highest power for sizing purpose, Watts – \u003cstrong\u003eWrt + Wah\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003e* It is assumed that only one out of the selected items starts at one time\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003eSince the AC loads rarely start at the same time, the load with the highest Additional Starting Power \u003cstrong\u003eWah\u003c\/strong\u003e has been factored in.\u003c\/p\u003e\n\u003cp\u003eExample:\u003cbr\u003e\u003c\/p\u003e\n\u003ctable class=\"tablepress tablepress-id-15 tablepress-responsive\" id=\"tablepress-15\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"row-1 odd\"\u003e\n\u003cth class=\"column-1\"\u003e\n\u003cp\u003e\u003csmall\u003eDevice \/ Appliance\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/th\u003e\n\u003cth class=\"column-2\"\u003e\n\u003cp\u003e\u003csmall\u003eRunning Power, Wr, Watts\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/th\u003e\n\u003cth class=\"column-3\"\u003e\n\u003cp\u003e\u003csmall\u003eAdditional\u003cbr\u003eStarting Power or Additional Continuous Power *, Wa, Watts\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/th\u003e\n\u003cth class=\"column-4\"\u003e\n\u003cp\u003e\u003csmall\u003eQuantity\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/th\u003e\n\u003cth class=\"column-5\"\u003e\n\u003cp\u003e\u003csmall\u003eExtended\u003cbr\u003eRunning Power, Wt, Watts\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody class=\"row-hover\"\u003e\n\u003ctr class=\"row-2 even\"\u003e\n\u003ctd class=\"column-1\"\u003e\n\u003cp\u003e\u003csmall\u003eRefrigerator – Electric Compressor based\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"column-2\"\u003e\n\u003cp\u003e\u003csmall\u003e200\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"column-3\"\u003e\n\u003cp\u003e\u003csmall\u003e800\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"column-4\"\u003e\n\u003cp\u003e\u003csmall\u003e1\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"column-5\"\u003e\n\u003cp\u003e\u003csmall\u003e200\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"row-3 odd\"\u003e\n\u003ctd class=\"column-1\"\u003e\n\u003cp\u003e\u003csmall\u003eColor TV\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"column-2\"\u003e\n\u003cp\u003e\u003csmall\u003e225\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"column-3\"\u003e\n\u003cp\u003e\u003csmall\u003e450\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"column-4\"\u003e\n\u003cp\u003e\u003csmall\u003e1\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"column-5\"\u003e\n\u003cp\u003e\u003csmall\u003e225\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"row-4 even\"\u003e\n\u003ctd class=\"column-1\"\u003e\n\u003cp\u003e\u003csmall\u003eLaptop Adapter\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"column-2\"\u003e\n\u003cp\u003e\u003csmall\u003e120\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"column-3\"\u003e\n\u003cp\u003e\u003csmall\u003e240\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"column-4\"\u003e\n\u003cp\u003e\u003csmall\u003e1\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"column-5\"\u003e\n\u003cp\u003e\u003csmall\u003e120\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"row-5 odd\"\u003e\n\u003ctd class=\"column-1\"\u003e\n\u003cp\u003e\u003csmall\u003eIncandescent Lamps\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"column-2\"\u003e\n\u003cp\u003e\u003csmall\u003e60\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"column-3\"\u003e\n\u003cp\u003e\u003csmall\u003e0\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"column-4\"\u003e\n\u003cp\u003e\u003csmall\u003e6\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"column-5\"\u003e\n\u003cp\u003e\u003csmall\u003e360\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e*\u003c\/strong\u003e \u003cem\u003eAdditional Continuous Power is applicable to SMPS based loads that have no Power Factor Correction.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003eTotal Extended Running Power, \u003cstrong\u003eWrt\u003c\/strong\u003e = 200 + 225 + 120 + 360 = \u003cstrong\u003e905\u003c\/strong\u003e Watts\u003c\/p\u003e\n\u003cp\u003eHighest Additional Starting Power, \u003cstrong\u003eWah\u003c\/strong\u003e = \u003cstrong\u003e800\u003c\/strong\u003e Watts\u003c\/p\u003e\n\u003cp\u003eHighest Power for sizing the inverter = Total Running Power, \u003cstrong\u003eWrt\u003c\/strong\u003e(905 W) + Highest Additional Starting Power, \u003cstrong\u003eWah\u003c\/strong\u003e (800 W) = \u003cstrong\u003e1705\u003c\/strong\u003e Watts\u003c\/p\u003e\n\u003ch5 class=\"r-faqs--faq-question j-faqs--question\"\u003eWhat are the electrical standards pertaining to DC-AC inverters?\u003c\/h5\u003e\n\u003cdiv class=\"r-faqs--faq-answer j-faqs--answer open\"\u003e\n\u003cmeta charset=\"utf-8\"\u003e\n\u003cp\u003eThe DC input voltage must conform to that of the electrical system and battery bank. 12 volts is recommended for small, simple systems. 24 and 48 volts are the common standards for higher capacities. A higher voltage system carries less current, which makes the system wiring cheaper and easier.\u003c\/p\u003e\n\u003cp\u003eThe inverter’s AC output must conform to the conventional power in the region to run locally available appliances. The standard for AC utility service in North America is 120 and 240 Volts at a frequency of 60 Hertz (cycles per second). In Europe, South America, and most other places, it is 230 volts at 50 Hertz.\u003c\/p\u003e\n\u003ch5 class=\"r-faqs--faq-question j-faqs--question\"\u003eWhat are \"continuous\" and \"surge\" power capacity ratings for DC-AC inverters?\u003c\/h5\u003e\n\u003cdiv id=\"What-are-continuous-and-surge-power-capacity-ratings-for-DC-AC-inverters\" class=\"r-faqs--faq j-faqs--single\"\u003e\n\u003cdiv class=\"r-faqs--faq-answer j-faqs--answer open\"\u003e\n\u003cp\u003eHow much load can an inverter handle? Its power output is rated in Watts.  There are two levels of power rating -a continuous rating and a surge rating. Continuous means the amount of power the inverter can handle for an indefinite period of hours. When an inverter is rated at a certain number of Watts, that number generally refers to its continuous rating. The “surge power” indicates the power to handle instantaneous overload of a few seconds to provide the higher power required to start certain type of devices and appliances.  Resistive types of loads (like incandescent lamps, toaster, coffee maker, electric range, iron etc) do not require extra power to start. Their starting power is the same as their running power.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cspan class=\"r-faqs--faq-toggle s-read-more j-faqs--toggle\"\u003e\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"r-faqs--faq j-faqs--single\"\u003e\n\u003ch5 class=\"r-faqs--faq-question j-faqs--question\"\u003eHow do \"surge power\" electrical loads affect DC-AC inverter operation?\u003c\/h5\u003e\n\u003cp\u003eIf an inverter cannot efficiently feed the surge power, it may simply shut down instead of starting the device. If the inverter’s surge capacity is marginal, its output voltage will dip during the surge. This can cause a dimming of the lights in the house, and will sometimes crash a computer.\u003c\/p\u003e\n\u003cp\u003eAny weakness in the battery and cabling to the inverter will further limit its ability to start a motor. A battery bank that is undersized, in poor condition, or has corroded connections, can be a weak link in the power chain. The inverter cables and the battery interconnect cables must be sized properly. The spike of DC current through these cables is many hundreds of amps at the instant of a motor starting for example.\u003c\/p\u003e\n\u003ch5 class=\"r-faqs--faq-question j-faqs--question\"\u003eHow should I size my DC-AC inverter for loads that require starting surge?\u003c\/h5\u003e\n\u003cdiv id=\"How-should-I-size-my-DC-AC-inverter-for-loads-that-require-starting-surge\" class=\"r-faqs--faq j-faqs--single\"\u003e\n\u003cdiv class=\"r-faqs--faq-answer j-faqs--answer open\"\u003e\n\u003cp\u003eObserve the following guideline to determine the continuous wattage of the inverter for powering loads that require starting surge. (Multiply the running watts of the device\/appliance by the Surge Factor)\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003e\u003cstrong\u003eNOTE:\u003c\/strong\u003e The surge power rating specified for this inverter is valid for duration of less than 1 second. This very short duration may not be sufficient to start motor based loads which may require up to 5 seconds to complete starting process. Hence, for purposes of sizing the inverter, use only the continuous power rating of this inverter.\u003c\/em\u003e\u003c\/p\u003e\n\u003ctable class=\"tablepress tablepress-id-16 tablepress-responsive\" id=\"tablepress-16\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"row-1 odd\"\u003e\n\u003cth class=\"column-1\"\u003e\n\u003cp\u003e\u003csmall\u003eDevice \/ Appliance\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/th\u003e\n\u003cth class=\"column-2\"\u003e\n\u003cp\u003e\u003csmall\u003eSurge Factor\u003cbr\u003e(No. of times the running power rating of the device\/appliance)\u003c\/small\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody class=\"row-hover\"\u003e\n\u003ctr class=\"row-2 even\"\u003e\n\u003ctd class=\"column-1\"\u003e\n\u003cp\u003e\u003csmall\u003eRefrigerator \/ Freezer\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"column-2\"\u003e\n\u003cp\u003e\u003csmall\u003e5\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"row-3 odd\"\u003e\n\u003ctd class=\"column-1\"\u003e\n\u003cp\u003e\u003csmall\u003eAir Compressors\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"column-2\"\u003e\n\u003cp\u003e\u003csmall\u003e4\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"row-4 even\"\u003e\n\u003ctd class=\"column-1\"\u003e\n\u003cp\u003e\u003csmall\u003eDishwasher\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"column-2\"\u003e\n\u003cp\u003e\u003csmall\u003e3\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"row-5 odd\"\u003e\n\u003ctd class=\"column-1\"\u003e\n\u003cp\u003e\u003csmall\u003eSump pump\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"column-2\"\u003e\n\u003cp\u003e\u003csmall\u003e3\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"row-6 even\"\u003e\n\u003ctd class=\"column-1\"\u003e\n\u003cp\u003e\u003csmall\u003eFurnace fans\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"column-2\"\u003e\n\u003cp\u003e\u003csmall\u003e3\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"row-7 odd\"\u003e\n\u003ctd class=\"column-1\"\u003e\n\u003cp\u003e\u003csmall\u003eIndustrial motors\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"column-2\"\u003e\n\u003cp\u003e\u003csmall\u003e3\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"row-8 even\"\u003e\n\u003ctd class=\"column-1\"\u003e\n\u003cp\u003e\u003csmall\u003eCircular saw\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"column-2\"\u003e\n\u003cp\u003e\u003csmall\u003e3\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"row-9 odd\"\u003e\n\u003ctd class=\"column-1\"\u003e\n\u003cp\u003e\u003csmall\u003eBench Grinder\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"column-2\"\u003e\n\u003cp\u003e\u003csmall\u003e3\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"row-10 even\"\u003e\n\u003ctd class=\"column-1\"\u003e\n\u003cp\u003e\u003csmall\u003ePortable diesel \/ kerosene fuel heater\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"column-2\"\u003e\n\u003cp\u003e\u003csmall\u003e2\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cspan class=\"r-faqs--faq-toggle s-read-more j-faqs--toggle\"\u003e\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"r-faqs--faq j-faqs--single\"\u003e\n\u003cdiv id=\"How-should-I-size-my-DC-AC-inverter-to-operate-a-microwave\" class=\"r-faqs--faq j-faqs--single\"\u003e\n\u003ch5 class=\"r-faqs--faq-question j-faqs--question\"\u003eHow should I size my DC-AC inverter to operate a microwave?\u003c\/h5\u003e\n\u003cspan class=\"r-faqs--faq-toggle s-read-more j-faqs--toggle\"\u003e\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"r-faqs--faq j-faqs--single\"\u003e\n\u003cdiv id=\"How-should-I-size-my-DC-AC-inverter-to-operate-a-microwave\" class=\"r-faqs--faq j-faqs--single\"\u003e\n\u003cdiv class=\"r-faqs--faq-answer j-faqs--answer open\"\u003e\n\u003cp\u003eThe power rating of the microwave generally refers to the cooking power. The electrical power consumed by the microwave will be approximately 2 times the cooking power. The “surge power” of the inverter should be 2 times the electrical power (i.e., 4 times the cooking power). Please note that the surge power of the microwave is not as long as the motor load and hence, the surge power of the inverter can be considered to determine adequacy of meeting the starting surge power.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cspan class=\"r-faqs--faq-toggle s-read-more j-faqs--toggle\"\u003e\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"r-faqs--faq j-faqs--single\"\u003e\n\u003ch5 class=\"r-faqs--faq-question j-faqs--question\"\u003eHow should I size my DC-AC inverter to power a water supply pump?\u003c\/h5\u003e\n\u003cp\u003eA water well or pressure pump often places the greatest demand on the inverter. It warrants special consideration. Most pumps draw a very high surge of current during start up. The inverter must have sufficient surge capacity to handle it while running any other loads that may be on. It is important to size an inverter sufficiently, especially to handle the starting surge (If the exact starting rating is not available, the starting surge can be taken as 3 times the normal running rating of the pump). Oversize it still further if you want it to start the pump without causing lights to dim or blink.\u003c\/p\u003e\n\u003cp\u003eIn North America, most pumps (especially submersibles) run on 240 VAC, while smaller appliances and lights use 120 VAC. To obtain 240 VAC from a 120 VAC inverter, use a 120 VAC to 240 VAC transformer. If you do not already have a pump installed, you can get a 120 volt pump if you don’t need more than 1\/2 HP.\u003c\/p\u003e\n\u003ch5 class=\"r-faqs--faq-question j-faqs--question\"\u003eWhat is \"idle power\" in a DC-AC inverter?\u003c\/h5\u003e\n\u003cdiv id=\"What-is-idle-power-in-a-DC-AC-inverter\" class=\"r-faqs--faq j-faqs--single\"\u003e\n\u003cdiv class=\"r-faqs--faq-answer j-faqs--answer open\"\u003e\n\u003cp\u003eIdle power is the consumption of the inverter when it is on, but no loads are running. It is “wasted” power, so if you expect the inverter to be on for many hours during which there is very little load (as in most residential situations), you want this to be as low as possible.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cspan class=\"r-faqs--faq-toggle s-read-more j-faqs--toggle\"\u003e\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"r-faqs--faq j-faqs--single\"\u003e\n\u003ch5 class=\"r-faqs--faq-question j-faqs--question\"\u003eWhat are Phantom and idling loads?\u003c\/h5\u003e\n\u003cp\u003eMost of the modern gadgets draw some power whenever they are plugged in. Some of them use power to do nothing at all. An example is a TV with a remote control. Its electric eye system is on day and night, watching for your signal to turn the screen on. Every appliance with an external wall-plug transformer uses power even when the appliance is turned off. These little loads are called “phantom loads” because their power draw is unexpected, unseen, and easily forgotten.\u003c\/p\u003e\n\u003cp\u003eA similar concern is “idling loads.” These are devices that must be on all the time in order to function when needed. These include smoke detectors, alarm systems, motion detector lights, fax machines, and answering machines. Central heating systems have a transformer in their thermostat circuit that stays on all the time. Cordless (rechargeable) appliances draw power even after their batteries reach a full charge. If in doubt, feel the device. If it’s warm, that indicates wasted energy.\u003c\/p\u003e\n\u003ch5 class=\"r-faqs--faq-question j-faqs--question\"\u003eCan a standard DC-AC inverter be connected in parallel with another AC source\/ DC-AC inverter \/ electrical utility?\u003c\/h5\u003e\n\u003cdiv id=\"Can-a-standard-DC-AC-inverter-be-connected-in-parallel-with-another-AC-source-DC-AC-inverter-electrical-utility\" class=\"r-faqs--faq j-faqs--single\"\u003e\n\u003cdiv class=\"r-faqs--faq-answer j-faqs--answer open\"\u003e\n\u003cp\u003eThe AC output of standard inverters cannot be synchronised with another AC source and hence, it is not suitable for paralleling. The AC output of the inverter should never be connected directly to an electrical breaker panel \/ load center which is also fed from the utility power \/generator. Such a connection may result in parallel operation of the different power sources and AC power from the utility \/ generator will be fed back into the inverter which will instantly damage the output section of the inverter and may also pose a fire and safety hazard.\u003c\/p\u003e\n\u003cp\u003eIf an electrical breaker panel \/ load center is fed from an inverter and this panel is also required to be powered from additional alternate AC sources, the AC power from all the AC sources like the utility \/ generator \/ inverter should first be fed to a manual selector switch and the output of the selector switch should be connected to the electrical breaker panel \/ load center. To prevent possibility of paralleling and severe damage to the inverter, never use a simple jumper cable with a male plug on both ends to connect the AC output of the inverter to a handy wall receptacle in the home\/RV.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cspan class=\"r-faqs--faq-toggle s-read-more j-faqs--toggle\"\u003e\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"r-faqs--faq j-faqs--single\"\u003e\n\u003ch5 class=\"r-faqs--faq-question j-faqs--question\"\u003eHow can DC-AC inverters be connected to multi-wire branch circuits?\u003c\/h5\u003e\n\u003cdiv id=\"How-can-DC-AC-inverters-be-connected-to-multi-wire-branch-circuits\" class=\"r-faqs--faq j-faqs--single\"\u003e\n\u003cdiv class=\"r-faqs--faq-answer j-faqs--answer open\"\u003e\n\u003cp\u003eDo not directly connect the hot side of the inverter to the two hot legs of the 120 \/ 240 VAC electrical breaker panel \/ load centre where multi-wire ( common neutral ) branch circuit wiring method is used for distribution of AC power. This may lead to overloading\/overheating of the neutral conductor and is a risk of fire.\u003c\/p\u003e\n\u003cp\u003eA split phase transformer (isolated or auto-transformer ) of suitable wattage rating ( 25% more than the wattage rating of the inverter ) with primary of 120 VAC and secondary of 120 \/ 240 VAC ( Two 120 VAC split phases 180 degrees apart) should be used. The hot and neutral of the 120 VAC output of the inverter should be fed to the primary of this transformer and the 2 hot outputs (120 VAC split phases ) and the neutral from the secondary of this transformer should be connected to the electrical breaker panel\/ load centre.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cspan class=\"r-faqs--faq-toggle s-read-more j-faqs--toggle\"\u003e\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv id=\"How-should-I-size-my-DC-AC-inverter-to-supply-computer-or-printer-loads\" class=\"r-faqs--faq j-faqs--single\"\u003e\n\u003ch5 class=\"r-faqs--faq-question j-faqs--question\"\u003eHow should I size my DC-AC inverter to supply computer or printer loads?\u003c\/h5\u003e\n\u003cdiv id=\"How-should-I-size-my-DC-AC-inverter-to-supply-computer-or-printer-loads\" class=\"r-faqs--faq j-faqs--single\"\u003e\n\u003cdiv class=\"r-faqs--faq-answer j-faqs--answer open\"\u003e\n\u003cp\u003eComputers and Printers generally come with in-built switch-mode power supplies (see \u003ca href=\"https:\/\/samlexamerica.com\/resources-support\/application-notes\/\"\u003eapplication notes\u003c\/a\u003e and \u003ca href=\"https:\/\/samlexamerica.com\/resources-support\/faq\/inverters-powering-direct-embedded-smps\/\"\u003eFAQs on switch mode power supplies (SMPS)\u003c\/a\u003e) that have extremely low power factor on account of the extremely peaky and non-linear nature of the current drawn by them from the AC source. Hence for such loads we recommend using inverters with three times the advertised power consumption of the computer or printer loads.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cspan class=\"r-faqs--faq-toggle s-read-more j-faqs--toggle\"\u003e\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"r-faqs--faq j-faqs--single\"\u003e\n\u003ch5 class=\"r-faqs--faq-question j-faqs--question\"\u003eWhat is the difference between a 12V, 24V and 48V inverter?\u003c\/h5\u003e\n\u003cdiv class=\"o-resource-body\"\u003e\n\u003cdiv class=\"r-faqs j-faqs\"\u003e\n\u003cdiv class=\"r-faqs--container\"\u003e\n\u003cdiv class=\"r-faqs--faqs j-faqs--faqs\"\u003e\n\u003cdiv id=\"What-is-the-difference-between-a-12V-24V-and-48V-inverter\" class=\"r-faqs--faq j-faqs--single\"\u003e\n\u003cdiv class=\"r-faqs--faq-answer j-faqs--answer open\"\u003e\n\u003cp\u003eA 12-V can be fed from a 12V battery or DC supply. Similarly 24V and 48V inverters can be fed from 24V and 48V batteries\/DC power supplies, respectively. Cars usually have 12V batteries. Trucks have 24V batteries.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Samlex America","offers":[{"title":"Default Title","offer_id":50359596876059,"sku":"OGL-67271","price":132.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0724\/2026\/2171\/files\/67271XL.jpg?v=1749567219"},{"product_id":"victron-orion-ip67-dc-dc-converter-24-vdc-to-12-vdc-100amp-ori241221226","title":"Victron Energy Orion IP67 DC-DC Converter - 24 VDC to 12 VDC - 100AMP [ORI241221226]","description":"\u003ch2\u003e\u003cspan style=\"text-decoration: underline;\"\u003eVictron Energy Orion IP67 DC-DC Converter - 24 VDC to 12 VDC - 100AMP [ORI241221226]\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eCompletely encapsulated: waterproof, shockproof and ignition protected Water, oil or dirt will not damage the Orion IP67 DC-DC Converter. The casing is made of cast aluminium and the electronics are moulded in resin. \u003c\/li\u003e\n\u003cli\u003eExtra-long input and output cables Thanks to the cables of 1.8 meters in length, intermediate cable interconnections to increase length even more will in most cases not be needed. This is an important reliability increasing feature in an area were IP67 protection grade is needed. \u003c\/li\u003e\n\u003cli\u003eWide input voltage range With 15 to 40 Volts input range, a stable output is ensured during surges or sags due to other equipment connected to same battery. \u003c\/li\u003e\n\u003cli\u003eProtected against overheating It can be used in a hot environment such as a machine room.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.victronenergy.com\/upload\/documents\/20150209_Warranty_final_en.pdf\" rel=\"noopener noreferrer\" target=\"_blank\"\u003eWarranty Info\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/productimageserver.com\/prop65\/6pt.png\" alt=\"Warning\"\u003e\u003cstrong\u003eWARNING:\u003c\/strong\u003e This product can expose you to chemicals which are known to the State of California to cause cancer, birth defects or other reproductive harm. For more information go to \u003ca href=\"http:\/\/P65Warnings.ca.gov\"\u003eP65Warnings.ca.gov\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cmeta charset=\"utf-8\"\u003e\u003cstrong\u003eOnce purchased and in use, this product is non-returnable.\u003c\/strong\u003e\u003c\/p\u003e\n\u003c!--- cis2:m2lsnZdp ---\u003e\n\u003ch3\u003eProduct Specifications\u003c\/h3\u003e\n\u003ch2\u003e\n\u003cspan style=\"text-decoration: underline;\"\u003eVictron Energy Orion IP67 DC-DC Converter - 24 VDC to 12 VDC - 100AMP [ORI241221226] \u003cmeta charset=\"utf-8\"\u003e\u003c\/span\u003e\u003cspan style=\"text-decoration: underline;\"\u003eProduct Specifications\u003c\/span\u003e\n\u003c\/h2\u003e\n\u003cp data-start=\"555\" data-end=\"588\"\u003e\u003cstrong data-start=\"559\" data-end=\"588\"\u003eElectrical Specifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"589\" data-end=\"796\"\u003e\n\u003cli data-start=\"589\" data-end=\"628\"\u003e\n\u003cp data-start=\"591\" data-end=\"628\"\u003e\u003cstrong data-start=\"591\" data-end=\"615\"\u003eInput Voltage Range:\u003c\/strong\u003e 18–35 V DC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"629\" data-end=\"664\"\u003e\n\u003cp data-start=\"631\" data-end=\"664\"\u003e\u003cstrong data-start=\"631\" data-end=\"650\"\u003eOutput Voltage:\u003c\/strong\u003e 12 V DC ±3%\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"665\" data-end=\"705\"\u003e\n\u003cp data-start=\"667\" data-end=\"705\"\u003e\u003cstrong data-start=\"667\" data-end=\"686\"\u003eOutput Current:\u003c\/strong\u003e 100 A continuous\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"706\" data-end=\"734\"\u003e\n\u003cp data-start=\"708\" data-end=\"734\"\u003e\u003cstrong data-start=\"708\" data-end=\"725\"\u003eOutput Power:\u003c\/strong\u003e 1200 W\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"735\" data-end=\"796\"\u003e\n\u003cp data-start=\"737\" data-end=\"796\"\u003e\u003cstrong data-start=\"737\" data-end=\"752\"\u003eEfficiency:\u003c\/strong\u003e ~96% at full load; up to 97% at half load\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"803\" data-end=\"835\"\u003e\u003cstrong data-start=\"807\" data-end=\"835\"\u003eProtection \u0026amp; Performance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"836\" data-end=\"1088\"\u003e\n\u003cli data-start=\"836\" data-end=\"888\"\u003e\n\u003cp data-start=\"838\" data-end=\"888\"\u003eShort-circuit protection with automatic recovery\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"889\" data-end=\"945\"\u003e\n\u003cp data-start=\"891\" data-end=\"945\"\u003eOperates from –40 °C to +70 °C (derates above 40 °C)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"946\" data-end=\"1023\"\u003e\n\u003cp data-start=\"948\" data-end=\"1023\"\u003eSurge and sag resistance ensures stable output under voltage fluctuations\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1024\" data-end=\"1088\"\u003e\n\u003cp data-start=\"1026\" data-end=\"1088\"\u003eNon-isolated design (common ground between input and output)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1095\" data-end=\"1127\"\u003e\u003cstrong data-start=\"1099\" data-end=\"1127\"\u003ePhysical \u0026amp; Environmental\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1128\" data-end=\"1494\"\u003e\n\u003cli data-start=\"1128\" data-end=\"1189\"\u003e\n\u003cp data-start=\"1130\" data-end=\"1189\"\u003e\u003cstrong data-start=\"1130\" data-end=\"1144\"\u003eEnclosure:\u003c\/strong\u003e Die-cast aluminum with resin encapsulation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1190\" data-end=\"1250\"\u003e\n\u003cp data-start=\"1192\" data-end=\"1250\"\u003e\u003cstrong data-start=\"1192\" data-end=\"1215\"\u003eIngress Protection:\u003c\/strong\u003e IP67 (dust-tight and waterproof)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1251\" data-end=\"1336\"\u003e\n\u003cp data-start=\"1253\" data-end=\"1336\"\u003e\u003cstrong data-start=\"1253\" data-end=\"1266\"\u003eMounting:\u003c\/strong\u003e Surface mount, suitable for vehicles, boats, and harsh environments\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1337\" data-end=\"1396\"\u003e\n\u003cp data-start=\"1339\" data-end=\"1396\"\u003e\u003cstrong data-start=\"1339\" data-end=\"1354\"\u003eDimensions:\u003c\/strong\u003e 265 × 127 × 63 mm (10.4″ × 5.0″ × 2.5″)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1397\" data-end=\"1438\"\u003e\n\u003cp data-start=\"1399\" data-end=\"1438\"\u003e\u003cstrong data-start=\"1399\" data-end=\"1410\"\u003eWeight:\u003c\/strong\u003e Approx. 4.74 lb (2.15 kg)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1439\" data-end=\"1494\"\u003e\n\u003cp data-start=\"1441\" data-end=\"1494\"\u003e\u003cstrong data-start=\"1441\" data-end=\"1453\"\u003eCabling:\u003c\/strong\u003e Includes 1.8 m input and output cables\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1501\" data-end=\"1524\"\u003e\u003cstrong data-start=\"1505\" data-end=\"1524\"\u003eProduct Details\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1525\" data-end=\"1612\"\u003e\n\u003cli data-start=\"1525\" data-end=\"1559\"\u003e\n\u003cp data-start=\"1527\" data-end=\"1559\"\u003e\u003cstrong data-start=\"1527\" data-end=\"1544\"\u003eModel Number:\u003c\/strong\u003e ORI241221226\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1560\" data-end=\"1586\"\u003e\n\u003cp data-start=\"1562\" data-end=\"1586\"\u003e\u003cstrong data-start=\"1562\" data-end=\"1570\"\u003eUPC:\u003c\/strong\u003e 8719076048541\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1587\" data-end=\"1612\"\u003e\n\u003cp data-start=\"1589\" data-end=\"1612\"\u003e\u003cstrong data-start=\"1589\" data-end=\"1602\"\u003eWarranty:\u003c\/strong\u003e 5 years\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eProduct Manual\u003c\/h3\u003e\n\u003ch4\u003e\n\u003ca href=\"https:\/\/productimageserver.com\/literature\/quickGuide\/82861QG.pdf\" target=\"_blank\"\u003eQuick Guide (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/productimageserver.com\/literature\/brochure\/82861BR.pdf\" target=\"_blank\"\u003eBrochure (pdf)\u003c\/a\u003e\n\u003c\/h4\u003e\n\u003ch3\u003eProduct Warranty\u003c\/h3\u003e\n\u003ch2\u003e\u003cspan style=\"text-decoration: underline;\"\u003eVictron Energy Product Warranty\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cmeta charset=\"utf-8\"\u003eVictron Energy warrants its products to be free from defects in workmanship and materials for a period of 5 years from the date of purchase by the end-user, with a maximum of 66 months from the Victron Energy invoice date. Exceptions on this are: lead-acid batteries; 2 years from date of purchase by the end-user, with a maximum of 30 months from the Victron Energy invoice date, Lithium batteries; 3 years from date of purchase by the end-user. In addition to this, proof of correct battery usage is required when making a battery warranty claim.\u003c\/p\u003e\n\u003cp\u003eFor a 10% surcharge on the net price for products that came with a 5-year warranty, an additional 5 years of warranty can be purchased, bringing the total warranty to 10 years. Warranty extensions need to be applied for ultimately one year before expiration of the original term.\u003c\/p\u003e\n\u003cp\u003eDuring the warranty period, Victron Energy will, at its discretion, repair, replace or credit the defective product free of charge. The warranty does not include performing or reimbursing de‐installation, transportation, and re‐installation. This warranty will be considered void if the unit has suffered any physical damage or alteration, either internally or externally, and does not cover damages arising from improper use like:\u003c\/p\u003e\n\u003cp\u003e• Reverse of battery polarity.\u003c\/p\u003e\n\u003cp\u003e• Inadequate connection.\u003c\/p\u003e\n\u003cp\u003e• Mechanical shock or deformation.\u003c\/p\u003e\n\u003cp\u003e• Contact with liquid or oxidation by condensation.\u003c\/p\u003e\n\u003cp\u003e• Use in an inappropriate environment(dust, corrosive vapor, humidity, high temperature, biological infestation...). \u003c\/p\u003e\n\u003cp\u003e• Breakage or damage due to lightning.\u003c\/p\u003e\n\u003cp\u003e• Connection terminals and screws destroyed or other damages, like overheat, due to insufficient tightening.\u003c\/p\u003e\n\u003cp\u003e• For any electronic breakage except due to lightning (reverse polarity, over‐voltage due to external cause), the state of the internal control diode and\/or the input\/output X and Y capacitors determine the warranty.\u003c\/p\u003e\n\u003cp\u003eThis warranty will not apply where the product has been misused, neglected, improperly installed, or repaired by anyone else than Victron Energy or one of its authorized Repair Centres. In order to qualify for the warranty, the product must not be disassembled or modified.\u003c\/p\u003e\n\u003cp\u003eRepair, replacement or credit are our sole remedies and Victron Energy shall not be liable for damages, whether direct, incidental, special, or consequential, even caused by negligence or fault.\u003c\/p\u003e\n\u003cp\u003eVictron Energy owns all parts removed from repaired products. Victron Energy uses new or reconditioned parts made by various manufacturers when performing warranty repairs or building replacement products. If Victron Energy repairs or replaces a part of a product, its warranty term is not extended.\u003c\/p\u003e\n\u003cp\u003eAll remedies and the measure for damages are limited to the above.\u003c\/p\u003e\n\u003cp\u003eVictron Energy shall in no event be liable for consequential, incidental, contingent or special damages, even if having been advised of the probability of such damages. Any and all other warranties expressed or implied arising by law, course of dealing, course of performance, usage of trade or otherwise, including but not limited to implied warranties of merchantability and fitness for a particular purpose, are limited in duration to a period of five (5) years from the date of purchase, with the exception of batteries. For lead acid batteries a two (2) year period applies and for lithium batteries a three (3) year period applies.\u003c\/p\u003e\n\u003ch3\u003eProduct FAQs\u003c\/h3\u003e\n\u003cp\u003eN\/A\u003c\/p\u003e","brand":"Victron Energy","offers":[{"title":"Default Title","offer_id":50359611719963,"sku":"OGL-82861","price":295.8,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0724\/2026\/2171\/files\/82861XL.jpg?v=1749567453"},{"product_id":"victron-orion-tr-dc-dc-converter-12-vdc-to-12-vdc-18amp-isolated-ori121222110","title":"Victron Energy Orion-TR DC-DC Converter - 12 VDC to 12 VDC - 18AMP Isolated [ORI121222110]","description":"\u003ch2\u003e\u003cspan style=\"text-decoration: underline;\"\u003eVictron Energy Orion-TR DC-DC Converter - 12 VDC to 12 VDC - 18AMP Isolated [ORI121222110]\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eRemote On\/Off Terminal\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe remote on\/off terminal eliminates the need for a high current switch in the input wiring. The remote on\/off can be operated with a low power switch or for example the engine run\/stop switch. \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAll Models Are Short Circuit Proof and Can Be Paralleled to Increase Output Current\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAn unlimited number of units can be connected in parallel.  \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHigh Temperature Protected \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe output current will reduce at high ambient temperatures.  \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIP43 Protection \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWhen installed with the screw terminals oriented downward.  \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eScrew Terminals \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo special tools are needed for installation.  \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInput Fuse (not replaceable) \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eOn 12 V and 24 V input models only.  \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAdjustable Output Voltage \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNot intended for battery charging (consider using an Orion-Tr Smart for battery charging).\u003c\/p\u003e\n\u003ch3\u003eProduct Specifications\u003c\/h3\u003e\n\u003ch2\u003e\n\u003cspan style=\"text-decoration: underline;\"\u003eVictron Energy Orion-TR DC-DC Converter - 12 VDC to 12 VDC - 18AMP Isolated [ORI121222110] \u003cmeta charset=\"utf-8\"\u003e\u003c\/span\u003e\u003cspan style=\"text-decoration: underline;\"\u003eProduct Specifications\u003c\/span\u003e\n\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eInput Voltage Range: 8-17 V\u003c\/li\u003e\n\u003cli\u003eUnder Voltage Shut Down: 7 V\u003c\/li\u003e\n\u003cli\u003eUnder Voltage Restart: 7.5 V\u003c\/li\u003e\n\u003cli\u003eNominal Output Voltage: 12.2 V\u003c\/li\u003e\n\u003cli\u003eOutput Voltage Adjust Range: 10-15 V\u003c\/li\u003e\n\u003cli\u003eOutput Voltage Tolerance: +\/- 0,2 V\u003c\/li\u003e\n\u003cli\u003eOutput Noise: 2 mV rms\u003c\/li\u003e\n\u003cli\u003eCont. Output Current at Nominal Output Voltage and 40 Degrees C: 18 A\u003c\/li\u003e\n\u003cli\u003eMaximum Output Current (10 S) at Nominal Output Voltage: 25 A\u003c\/li\u003e\n\u003cli\u003eShort Circuit Output Current: 40 A\u003c\/li\u003e\n\u003cli\u003eCont. Output Power at 25 Degrees C: 280 W\u003c\/li\u003e\n\u003cli\u003eCont. Output Power at 40 Degrees C: 220 W\u003c\/li\u003e\n\u003cli\u003eEfficiency: 87 %\u003c\/li\u003e\n\u003cli\u003eNo Load Input Current (2): \u0026lt; 80 mA \u003c\/li\u003e\n\u003cli\u003eCurrent Consumption: \u0026lt; 200uA when disabled via its remote port\u003c\/li\u003e\n\u003cli\u003eGalvanic Isolation: 200 VDC between input, output, and case\u003c\/li\u003e\n\u003cli\u003eOperating Temperature Range: -20 to +55 Degrees C (derate 3 % per °C above 40 °C)\u003c\/li\u003e\n\u003cli\u003eHumidity: Max. 95 % non-condensing\u003c\/li\u003e\n\u003cli\u003eDC Connection: Screw terminals\u003c\/li\u003e\n\u003cli\u003eMaximum Cable Cross-Section: 16 mm² AWG6\u003c\/li\u003e\n\u003cli\u003eWeight: 1.3 kg (3 lb)\u003c\/li\u003e\n\u003cli\u003eDimensions (H x W x D): 130 x 186 x 70 mm (5.1 x 7.3 x 2.8 inch)\u003c\/li\u003e\n\u003cli\u003eSafety Standards: EN 60950\u003c\/li\u003e\n\u003cli\u003eImmunity Standards: EN 61000-6-3, EN 61000-6-1, EN 55014-2\u003c\/li\u003e\n\u003cli\u003eAutomotive Directive Standards: ECE R10-5\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cimg alt=\"Warning\" src=\"https:\/\/productimageserver.com\/prop65\/6pt.png\"\u003e\u003cstrong\u003eWARNING:\u003c\/strong\u003e This product can expose you to chemicals which are known to the State of California to cause cancer, birth defects or other reproductive harm. For more information go to \u003ca href=\"http:\/\/P65Warnings.ca.gov\"\u003eP65Warnings.ca.gov\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cmeta charset=\"utf-8\"\u003e\u003cstrong\u003eOnce purchased and in use, this product is non-returnable.\u003c\/strong\u003e\u003c\/p\u003e\n\u003c!--- cis2:m2lsnZdp ---\u003e\n\u003cp\u003e\u003cb\u003eSpecifications:\u003c\/b\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eCharger Input - Voltage: 12v\u003c\/li\u003e\n\u003cli\u003eCharger Output - Amps: 18a\u003c\/li\u003e\n\u003cli\u003eCharger Output Voltage: 12v\u003c\/li\u003e\n\u003cli\u003eBox Dimensions: 4\"H x 6\"W x 8\"L WT: 2.8 lbs\u003c\/li\u003e\n\u003cli\u003eUPC: 8719076035237\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eProduct Manual\u003c\/h3\u003e\n\u003ch4\u003e\n\u003ca href=\"https:\/\/productimageserver.com\/literature\/quickGuide\/82868QG.pdf\" target=\"_blank\"\u003eQuick Guide (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/productimageserver.com\/literature\/ownersManual\/82868OM.pdf\" target=\"_blank\"\u003eOwner's Manual (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/productimageserver.com\/literature\/brochure\/82868BR.pdf\" target=\"_blank\"\u003eBrochure (pdf)\u003c\/a\u003e\n\u003c\/h4\u003e\n\u003ch3\u003eProduct Warranty\u003c\/h3\u003e\n\u003ch2\u003e\u003cspan style=\"text-decoration: underline;\"\u003eVictron Energy Product Warranty\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cmeta charset=\"utf-8\"\u003eVictron Energy warrants its products to be free from defects in workmanship and materials for a period of 5 years from the date of purchase by the end-user, with a maximum of 66 months from the Victron Energy invoice date. Exceptions on this are: lead-acid batteries; 2 years from date of purchase by the end-user, with a maximum of 30 months from the Victron Energy invoice date, Lithium batteries; 3 years from date of purchase by the end-user. In addition to this, proof of correct battery usage is required when making a battery warranty claim.\u003c\/p\u003e\n\u003cp\u003eFor a 10% surcharge on the net price for products that came with a 5-year warranty, an additional 5 years of warranty can be purchased, bringing the total warranty to 10 years. Warranty extensions need to be applied for ultimately one year before expiration of the original term.\u003c\/p\u003e\n\u003cp\u003eDuring the warranty period, Victron Energy will, at its discretion, repair, replace or credit the defective product free of charge. The warranty does not include performing or reimbursing de‐installation, transportation, and re‐installation. This warranty will be considered void if the unit has suffered any physical damage or alteration, either internally or externally, and does not cover damages arising from improper use like:\u003c\/p\u003e\n\u003cp\u003e• Reverse of battery polarity.\u003c\/p\u003e\n\u003cp\u003e• Inadequate connection.\u003c\/p\u003e\n\u003cp\u003e• Mechanical shock or deformation.\u003c\/p\u003e\n\u003cp\u003e• Contact with liquid or oxidation by condensation.\u003c\/p\u003e\n\u003cp\u003e• Use in an inappropriate environment(dust, corrosive vapor, humidity, high temperature, biological infestation...). \u003c\/p\u003e\n\u003cp\u003e• Breakage or damage due to lightning.\u003c\/p\u003e\n\u003cp\u003e• Connection terminals and screws destroyed or other damages, like overheat, due to insufficient tightening.\u003c\/p\u003e\n\u003cp\u003e• For any electronic breakage except due to lightning (reverse polarity, over‐voltage due to external cause), the state of the internal control diode and\/or the input\/output X and Y capacitors determine the warranty.\u003c\/p\u003e\n\u003cp\u003eThis warranty will not apply where the product has been misused, neglected, improperly installed, or repaired by anyone else than Victron Energy or one of its authorized Repair Centres. In order to qualify for the warranty, the product must not be disassembled or modified.\u003c\/p\u003e\n\u003cp\u003eRepair, replacement or credit are our sole remedies and Victron Energy shall not be liable for damages, whether direct, incidental, special, or consequential, even caused by negligence or fault.\u003c\/p\u003e\n\u003cp\u003eVictron Energy owns all parts removed from repaired products. Victron Energy uses new or reconditioned parts made by various manufacturers when performing warranty repairs or building replacement products. If Victron Energy repairs or replaces a part of a product, its warranty term is not extended.\u003c\/p\u003e\n\u003cp\u003eAll remedies and the measure for damages are limited to the above.\u003c\/p\u003e\n\u003cp\u003eVictron Energy shall in no event be liable for consequential, incidental, contingent or special damages, even if having been advised of the probability of such damages. Any and all other warranties expressed or implied arising by law, course of dealing, course of performance, usage of trade or otherwise, including but not limited to implied warranties of merchantability and fitness for a particular purpose, are limited in duration to a period of five (5) years from the date of purchase, with the exception of batteries. For lead acid batteries a two (2) year period applies and for lithium batteries a three (3) year period applies.\u003c\/p\u003e\n\u003ch3\u003eProduct FAQs\u003c\/h3\u003e\n\u003cp\u003eN\/A\u003c\/p\u003e","brand":"Victron Energy","offers":[{"title":"Default Title","offer_id":50359611785499,"sku":"OGL-82868","price":113.9,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0724\/2026\/2171\/files\/82868XL.jpg?v=1749567454"},{"product_id":"victron-orion-tr-dc-dc-converter-12-vdc-to-12-vdc-30amp-isolated-ori121240110","title":"Victron Energy Orion-TR DC-DC Converter - 12 VDC to 12 VDC - 30AMP Isolated [ORI121240110]","description":"\u003ch2\u003e\u003cspan style=\"text-decoration: underline;\"\u003eVictron Energy Orion-TR DC-DC Converter - 12 VDC to 12 VDC - 30AMP Isolated [ORI121240110]\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eRemote On\/Off Terminal\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe remote on\/off terminal eliminates the need for a high current switch in the input wiring. The remote on\/off can be operated with a low power switch or for example the engine run\/stop switch. \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAll Models Are Short Circuit Proof and Can Be Paralleled to Increase Output Current\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAn unlimited number of units can be connected in parallel.  \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHigh Temperature Protected \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe output current will reduce at high ambient temperatures.  \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIP43 Protection \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWhen installed with the screw terminals oriented downward.  \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eScrew Terminals \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo special tools are needed for installation.  \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInput Fuse (not replaceable) \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eOn 12 V and 24 V input models only.  \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAdjustable Output Voltage \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNot intended for battery charging (consider using an Orion-Tr Smart for battery charging).\u003c\/p\u003e\n\u003ch3\u003eProduct Specifications\u003c\/h3\u003e\n\u003ch2\u003e\n\u003cspan style=\"text-decoration: underline;\"\u003eVictron Energy Orion-TR DC-DC Converter - 12 VDC to 12 VDC - 30AMP Isolated [ORI121240110] \u003cmeta charset=\"utf-8\"\u003e\u003c\/span\u003e\u003cspan style=\"text-decoration: underline;\"\u003eProduct Specifications\u003c\/span\u003e\n\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eInput Voltage Range: 10-17 V\u003c\/li\u003e\n\u003cli\u003eUnder Voltage Shut Down: 7 V\u003c\/li\u003e\n\u003cli\u003eUnder Voltage Restart: 7.5 V\u003c\/li\u003e\n\u003cli\u003eNominal Output Voltage: 12.2 V\u003c\/li\u003e\n\u003cli\u003eOutput Voltage Adjust Range: 10-15 V\u003c\/li\u003e\n\u003cli\u003eOutput Voltage Tolerance: +\/- 0,2 V\u003c\/li\u003e\n\u003cli\u003eOutput Noise: 2 mV rms\u003c\/li\u003e\n\u003cli\u003eCont. Output Current at Nominal Output Voltage and 40 Degrees C: 30 A\u003c\/li\u003e\n\u003cli\u003eMaximum output current (10 s) at nominal output voltage minus 20%: 40 A\u003c\/li\u003e\n\u003cli\u003eShort Circuit Output Current: 60 A\u003c\/li\u003e\n\u003cli\u003eCont. Output Power at 25 Degrees C: 430 W\u003c\/li\u003e\n\u003cli\u003eCont. Output Power at 40 Degrees C: 360 W\u003c\/li\u003e\n\u003cli\u003eEfficiency: 87 %\u003c\/li\u003e\n\u003cli\u003eNo Load Input Current (2): \u0026lt; 80 mA \u003c\/li\u003e\n\u003cli\u003eCurrent Consumption: \u0026lt; 200uA when disabled via its remote port\u003c\/li\u003e\n\u003cli\u003eGalvanic Isolation: 200 VDC between input, output, and case\u003c\/li\u003e\n\u003cli\u003eOperating Temperature Range: -20 to +55 Degrees C (derate 3 % per °C above 40 °C)\u003c\/li\u003e\n\u003cli\u003eHumidity: Max. 95 % non-condensing\u003c\/li\u003e\n\u003cli\u003eDC Connection: Screw terminals\u003c\/li\u003e\n\u003cli\u003eMaximum Cable Cross-Section: 16 mm² AWG6\u003c\/li\u003e\n\u003cli\u003eWeight: 1.8 kg (4 lb)\u003c\/li\u003e\n\u003cli\u003eDimensions (H x W x D): 130 x 186 x 80 mm (5.1 x 7.3 x 3.2 inch)\u003c\/li\u003e\n\u003cli\u003eSafety Standards: EN 60950\u003c\/li\u003e\n\u003cli\u003eImmunity Standards: EN 61000-6-2, EN 61000-6-1, EN 55014-2\u003c\/li\u003e\n\u003cli\u003eAutomotive Directive Standards: ECE R10-5\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cimg alt=\"Warning\" src=\"https:\/\/productimageserver.com\/prop65\/6pt.png\"\u003e\u003cstrong\u003eWARNING:\u003c\/strong\u003e This product can expose you to chemicals which are known to the State of California to cause cancer, birth defects or other reproductive harm. For more information go to \u003ca href=\"http:\/\/P65Warnings.ca.gov\"\u003eP65Warnings.ca.gov\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cmeta charset=\"utf-8\"\u003e\u003cstrong\u003eOnce purchased and in use, this product is non-returnable.\u003c\/strong\u003e\u003c\/p\u003e\n\u003c!--- cis2:m2lsnZdp ---\u003e\n\u003cp\u003e\u003cb\u003eSpecifications:\u003c\/b\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eCharger Input - Voltage: 12v\u003c\/li\u003e\n\u003cli\u003eCharger Output - Amps: 30a\u003c\/li\u003e\n\u003cli\u003eCharger Output Voltage: 12v\u003c\/li\u003e\n\u003cli\u003eBox Dimensions: 4\"H x 6\"W x 8\"L WT: 4.2 lbs\u003c\/li\u003e\n\u003cli\u003eUPC: 8719076038825\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eProduct Manual\u003c\/h3\u003e\n\u003ch4\u003e\n\u003ca href=\"https:\/\/productimageserver.com\/literature\/quickGuide\/82870QG.pdf\" target=\"_blank\"\u003eQuick Guide (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/productimageserver.com\/literature\/ownersManual\/82870OM.pdf\" target=\"_blank\"\u003eOwner's Manual (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/productimageserver.com\/literature\/brochure\/82870BR.pdf\" target=\"_blank\"\u003eBrochure (pdf)\u003c\/a\u003e\n\u003c\/h4\u003e\n\u003ch3\u003eProduct Warranty\u003c\/h3\u003e\n\u003ch2\u003e\u003cspan style=\"text-decoration: underline;\"\u003eVictron Energy Product Warranty\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cmeta charset=\"utf-8\"\u003eVictron Energy warrants its products to be free from defects in workmanship and materials for a period of 5 years from the date of purchase by the end-user, with a maximum of 66 months from the Victron Energy invoice date. Exceptions on this are: lead-acid batteries; 2 years from date of purchase by the end-user, with a maximum of 30 months from the Victron Energy invoice date, Lithium batteries; 3 years from date of purchase by the end-user. In addition to this, proof of correct battery usage is required when making a battery warranty claim.\u003c\/p\u003e\n\u003cp\u003eFor a 10% surcharge on the net price for products that came with a 5-year warranty, an additional 5 years of warranty can be purchased, bringing the total warranty to 10 years. Warranty extensions need to be applied for ultimately one year before expiration of the original term.\u003c\/p\u003e\n\u003cp\u003eDuring the warranty period, Victron Energy will, at its discretion, repair, replace or credit the defective product free of charge. The warranty does not include performing or reimbursing de‐installation, transportation, and re‐installation. This warranty will be considered void if the unit has suffered any physical damage or alteration, either internally or externally, and does not cover damages arising from improper use like:\u003c\/p\u003e\n\u003cp\u003e• Reverse of battery polarity.\u003c\/p\u003e\n\u003cp\u003e• Inadequate connection.\u003c\/p\u003e\n\u003cp\u003e• Mechanical shock or deformation.\u003c\/p\u003e\n\u003cp\u003e• Contact with liquid or oxidation by condensation.\u003c\/p\u003e\n\u003cp\u003e• Use in an inappropriate environment(dust, corrosive vapor, humidity, high temperature, biological infestation...). \u003c\/p\u003e\n\u003cp\u003e• Breakage or damage due to lightning.\u003c\/p\u003e\n\u003cp\u003e• Connection terminals and screws destroyed or other damages, like overheat, due to insufficient tightening.\u003c\/p\u003e\n\u003cp\u003e• For any electronic breakage except due to lightning (reverse polarity, over‐voltage due to external cause), the state of the internal control diode and\/or the input\/output X and Y capacitors determine the warranty.\u003c\/p\u003e\n\u003cp\u003eThis warranty will not apply where the product has been misused, neglected, improperly installed, or repaired by anyone else than Victron Energy or one of its authorized Repair Centres. In order to qualify for the warranty, the product must not be disassembled or modified.\u003c\/p\u003e\n\u003cp\u003eRepair, replacement or credit are our sole remedies and Victron Energy shall not be liable for damages, whether direct, incidental, special, or consequential, even caused by negligence or fault.\u003c\/p\u003e\n\u003cp\u003eVictron Energy owns all parts removed from repaired products. Victron Energy uses new or reconditioned parts made by various manufacturers when performing warranty repairs or building replacement products. If Victron Energy repairs or replaces a part of a product, its warranty term is not extended.\u003c\/p\u003e\n\u003cp\u003eAll remedies and the measure for damages are limited to the above.\u003c\/p\u003e\n\u003cp\u003eVictron Energy shall in no event be liable for consequential, incidental, contingent or special damages, even if having been advised of the probability of such damages. Any and all other warranties expressed or implied arising by law, course of dealing, course of performance, usage of trade or otherwise, including but not limited to implied warranties of merchantability and fitness for a particular purpose, are limited in duration to a period of five (5) years from the date of purchase, with the exception of batteries. For lead acid batteries a two (2) year period applies and for lithium batteries a three (3) year period applies.\u003c\/p\u003e\n\u003ch3\u003eProduct FAQs\u003c\/h3\u003e\n\u003cp\u003eN\/A\u003c\/p\u003e","brand":"Victron Energy","offers":[{"title":"Default Title","offer_id":50359611818267,"sku":"OGL-82870","price":201.45,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0724\/2026\/2171\/files\/82870XL.jpg?v=1749567453"},{"product_id":"victron-orion-tr-dc-dc-converter-24-vdc-to-12-vdc-20amp-isolated-ori241224110","title":"Victron Energy Orion-TR DC-DC Converter - 24 VDC to 12 VDC - 20AMP Isolated [ORI241224110]","description":"\u003ch2\u003e\u003cspan style=\"text-decoration: underline;\"\u003eVictron Energy Orion-TR DC-DC Converter - 24 VDC to 12 VDC - 20AMP Isolated [ORI241224110]\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eIsolated Model - separate in and out (-) leads \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRemote On\/Off Terminal\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe remote on\/off terminal eliminates the need for a high current switch in the input wiring. The remote on\/off can be operated with a low power switch or for example the engine run\/stop switch. \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAll Models Are Short Circuit Proof and Can Be Paralleled to Increase Output Current\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAn unlimited number of units can be connected in parallel.  \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHigh Temperature Protected \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe output current will reduce at high ambient temperatures.  \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIP43 Protection \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWhen installed with the screw terminals oriented downward.  \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eScrew Terminals \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo special tools are needed for installation.  \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInput Fuse (not replaceable) \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eOn 12 V and 24 V input models only.  \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAdjustable Output Voltage \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNot intended for battery charging (consider using an Orion-Tr Smart for battery charging).\u003c\/p\u003e\n\u003ch3\u003eProduct Specifications\u003c\/h3\u003e\n\u003ch2\u003e\n\u003cspan style=\"text-decoration: underline;\"\u003eVictron Energy Orion-TR DC-DC Converter - 24 VDC to 12 VDC - 20AMP Isolated [ORI241224110] \u003cmeta charset=\"utf-8\"\u003e\u003c\/span\u003e\u003cspan style=\"text-decoration: underline;\"\u003eProduct Specifications\u003c\/span\u003e\n\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eInput Voltage Range: 16-35 V\u003c\/li\u003e\n\u003cli\u003eUnder Voltage Shut Down: 14 V\u003c\/li\u003e\n\u003cli\u003eUnder Voltage Restart: 15 V\u003c\/li\u003e\n\u003cli\u003eNominal Output Voltage: 12.2 V\u003c\/li\u003e\n\u003cli\u003eOutput Voltage Adjust Range: 10-15 V\u003c\/li\u003e\n\u003cli\u003eOutput Voltage Tolerance: +\/- 0,2 V\u003c\/li\u003e\n\u003cli\u003eOutput Noise: 2 mV rms\u003c\/li\u003e\n\u003cli\u003eCont. Output Current at Nominal Output Voltage and 40 Degrees C: 20 A\u003c\/li\u003e\n\u003cli\u003eMaximum Output Current (10 S) at Nominal Output Voltage: 25 A\u003c\/li\u003e\n\u003cli\u003eShort Circuit Output Current: 50 A\u003c\/li\u003e\n\u003cli\u003eCont. Output Power at 25 Degrees C: 300 W\u003c\/li\u003e\n\u003cli\u003eCont. Output Power at 40 Degrees C: 240 W\u003c\/li\u003e\n\u003cli\u003eEfficiency: 88 %\u003c\/li\u003e\n\u003cli\u003eNo Load Input Current (2): \u0026lt; 100 mA \u003c\/li\u003e\n\u003cli\u003eCurrent Consumption: \u0026lt; 200uA when disabled via its remote port\u003c\/li\u003e\n\u003cli\u003eGalvanic Isolation: 200 VDC between input, output, and case\u003c\/li\u003e\n\u003cli\u003eOperating Temperature Range: -20 to +55 Degrees C (derate 3 % per °C above 40 °C)\u003c\/li\u003e\n\u003cli\u003eHumidity: Max. 95 % non-condensing\u003c\/li\u003e\n\u003cli\u003eDC Connection: Screw terminals\u003c\/li\u003e\n\u003cli\u003eMaximum Cable Cross-Section: 16 mm² AWG6\u003c\/li\u003e\n\u003cli\u003eWeight: 1.3 kg (3 lb)\u003c\/li\u003e\n\u003cli\u003eDimensions (H x W x D): 130 x 186 x 70 mm (5.1 x 7.3 x 2.8 inch)\u003c\/li\u003e\n\u003cli\u003eSafety Standards: EN 60950\u003c\/li\u003e\n\u003cli\u003eImmunity Standards: EN 61000-6-2, EN 61000-6-1, EN 55014-2\u003c\/li\u003e\n\u003cli\u003eAutomotive Directive Standards: ECE R10-5\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cimg alt=\"Warning\" src=\"https:\/\/productimageserver.com\/prop65\/6pt.png\"\u003e\u003cstrong\u003eWARNING:\u003c\/strong\u003e This product can expose you to chemicals which are known to the State of California to cause cancer, birth defects or other reproductive harm. For more information go to \u003ca href=\"http:\/\/P65Warnings.ca.gov\"\u003eP65Warnings.ca.gov\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cmeta charset=\"utf-8\"\u003e\u003cstrong\u003eOnce purchased and in use, this product is non-returnable.\u003c\/strong\u003e\u003c\/p\u003e\n\u003c!--- cis2:m2lsnZdp ---\u003e\n\u003cp\u003e\u003cb\u003eSpecifications:\u003c\/b\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eCharger Input - Voltage: 24v\u003c\/li\u003e\n\u003cli\u003eCharger Output - Amps: 20a\u003c\/li\u003e\n\u003cli\u003eCharger Output Voltage: 12v\u003c\/li\u003e\n\u003cli\u003eBox Dimensions: 4\"H x 6\"W x 8\"L WT: 2.9 lbs\u003c\/li\u003e\n\u003cli\u003eUPC: 8719076035251\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eProduct Manual\u003c\/h3\u003e\n\u003ch4\u003e\n\u003ca href=\"https:\/\/productimageserver.com\/literature\/quickGuide\/82876QG.pdf\" target=\"_blank\"\u003eQuick Guide (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/productimageserver.com\/literature\/ownersManual\/82876OM.pdf\" target=\"_blank\"\u003eOwner's Manual (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/productimageserver.com\/literature\/brochure\/82876BR.pdf\" target=\"_blank\"\u003eBrochure (pdf)\u003c\/a\u003e\n\u003c\/h4\u003e\n\u003ch3\u003eProduct Warranty\u003c\/h3\u003e\n\u003ch2\u003e\u003cspan style=\"text-decoration: underline;\"\u003eVictron Energy Product Warranty\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cmeta charset=\"utf-8\"\u003eVictron Energy warrants its products to be free from defects in workmanship and materials for a period of 5 years from the date of purchase by the end-user, with a maximum of 66 months from the Victron Energy invoice date. Exceptions on this are: lead-acid batteries; 2 years from date of purchase by the end-user, with a maximum of 30 months from the Victron Energy invoice date, Lithium batteries; 3 years from date of purchase by the end-user. In addition to this, proof of correct battery usage is required when making a battery warranty claim.\u003c\/p\u003e\n\u003cp\u003eFor a 10% surcharge on the net price for products that came with a 5-year warranty, an additional 5 years of warranty can be purchased, bringing the total warranty to 10 years. Warranty extensions need to be applied for ultimately one year before expiration of the original term.\u003c\/p\u003e\n\u003cp\u003eDuring the warranty period, Victron Energy will, at its discretion, repair, replace or credit the defective product free of charge. The warranty does not include performing or reimbursing de‐installation, transportation, and re‐installation. This warranty will be considered void if the unit has suffered any physical damage or alteration, either internally or externally, and does not cover damages arising from improper use like:\u003c\/p\u003e\n\u003cp\u003e• Reverse of battery polarity.\u003c\/p\u003e\n\u003cp\u003e• Inadequate connection.\u003c\/p\u003e\n\u003cp\u003e• Mechanical shock or deformation.\u003c\/p\u003e\n\u003cp\u003e• Contact with liquid or oxidation by condensation.\u003c\/p\u003e\n\u003cp\u003e• Use in an inappropriate environment(dust, corrosive vapor, humidity, high temperature, biological infestation...). \u003c\/p\u003e\n\u003cp\u003e• Breakage or damage due to lightning.\u003c\/p\u003e\n\u003cp\u003e• Connection terminals and screws destroyed or other damages, like overheat, due to insufficient tightening.\u003c\/p\u003e\n\u003cp\u003e• For any electronic breakage except due to lightning (reverse polarity, over‐voltage due to external cause), the state of the internal control diode and\/or the input\/output X and Y capacitors determine the warranty.\u003c\/p\u003e\n\u003cp\u003eThis warranty will not apply where the product has been misused, neglected, improperly installed, or repaired by anyone else than Victron Energy or one of its authorized Repair Centres. In order to qualify for the warranty, the product must not be disassembled or modified.\u003c\/p\u003e\n\u003cp\u003eRepair, replacement or credit are our sole remedies and Victron Energy shall not be liable for damages, whether direct, incidental, special, or consequential, even caused by negligence or fault.\u003c\/p\u003e\n\u003cp\u003eVictron Energy owns all parts removed from repaired products. Victron Energy uses new or reconditioned parts made by various manufacturers when performing warranty repairs or building replacement products. If Victron Energy repairs or replaces a part of a product, its warranty term is not extended.\u003c\/p\u003e\n\u003cp\u003eAll remedies and the measure for damages are limited to the above.\u003c\/p\u003e\n\u003cp\u003eVictron Energy shall in no event be liable for consequential, incidental, contingent or special damages, even if having been advised of the probability of such damages. Any and all other warranties expressed or implied arising by law, course of dealing, course of performance, usage of trade or otherwise, including but not limited to implied warranties of merchantability and fitness for a particular purpose, are limited in duration to a period of five (5) years from the date of purchase, with the exception of batteries. For lead acid batteries a two (2) year period applies and for lithium batteries a three (3) year period applies.\u003c\/p\u003e\n\u003ch3\u003eProduct FAQs\u003c\/h3\u003e\n\u003cp\u003eN\/A\u003c\/p\u003e","brand":"Victron Energy","offers":[{"title":"Default Title","offer_id":50359611851035,"sku":"OGL-82876","price":113.9,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0724\/2026\/2171\/files\/82876XL.jpg?v=1749567454"},{"product_id":"victron-orion-tr-dc-dc-converter-24-vdc-to-12-vdc-30amp-isolated-ori241240110","title":"Victron Energy Orion-TR DC-DC Converter - 24 VDC to 12 VDC - 30AMP Isolated [ORI241240110]","description":"\u003ch2\u003e\u003cspan style=\"text-decoration: underline;\"\u003eVictron Energy Orion-TR DC-DC Converter - 24 VDC to 12 VDC - 30AMP Isolated [ORI241240110]\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eIsolated Model - separate in and out (-) leads \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRemote On\/Off Terminal\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe remote on\/off terminal eliminates the need for a high current switch in the input wiring. The remote on\/off can be operated with a low power switch or for example the engine run\/stop switch. \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAll Models Are Short Circuit Proof and Can Be Paralleled to Increase Output Current\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAn unlimited number of units can be connected in parallel.  \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHigh Temperature Protected \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe output current will reduce at high ambient temperatures.  \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIP43 Protection \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWhen installed with the screw terminals oriented downward.  \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eScrew Terminals \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo special tools are needed for installation.  \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInput Fuse (not replaceable) \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eOn 12 V and 24 V input models only.  \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAdjustable Output Voltage \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNot intended for battery charging (consider using an Orion-Tr Smart for battery charging).\u003c\/p\u003e\n\u003ch3\u003eProduct Specifications\u003c\/h3\u003e\n\u003ch2\u003e\n\u003cspan style=\"text-decoration: underline;\"\u003eVictron Energy Orion-TR DC-DC Converter - 24 VDC to 12 VDC - 30AMP Isolated [ORI241240110] \u003cmeta charset=\"utf-8\"\u003e\u003c\/span\u003e\u003cspan style=\"text-decoration: underline;\"\u003eProduct Specifications\u003c\/span\u003e\n\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eInput Voltage Range: 20-35 V\u003c\/li\u003e\n\u003cli\u003eUnder Voltage Shut Down: 14 V\u003c\/li\u003e\n\u003cli\u003eUnder Voltage Restart: 15 V\u003c\/li\u003e\n\u003cli\u003eNominal Output Voltage: 12.2 V\u003c\/li\u003e\n\u003cli\u003eOutput Voltage Adjust Range: 10-15 V\u003c\/li\u003e\n\u003cli\u003eOutput Voltage Tolerance: +\/- 0,2 V\u003c\/li\u003e\n\u003cli\u003eOutput Noise: 2 mV rms\u003c\/li\u003e\n\u003cli\u003eCont. Output Current at Nominal Output Voltage and 40 Degrees C: 30 A\u003c\/li\u003e\n\u003cli\u003eMaximum Output Current (10 S) at Nominal Output Voltage: 45 A\u003c\/li\u003e\n\u003cli\u003eShort Circuit Output Current: 60 A\u003c\/li\u003e\n\u003cli\u003eCont. Output Power at 25 Degrees C: 430 W\u003c\/li\u003e\n\u003cli\u003eCont. Output Power at 40 Degrees C: 360 W\u003c\/li\u003e\n\u003cli\u003eEfficiency: 88 %\u003c\/li\u003e\n\u003cli\u003eNo Load Input Current (2): \u0026lt; 100 mA \u003c\/li\u003e\n\u003cli\u003eCurrent Consumption: \u0026lt; 200uA when disabled via its remote port\u003c\/li\u003e\n\u003cli\u003eGalvanic Isolation: 200 VDC between input, output, and case\u003c\/li\u003e\n\u003cli\u003eOperating Temperature Range: -20 to +55 Degrees C (derate 3 % per °C above 40 °C)\u003c\/li\u003e\n\u003cli\u003eHumidity: Max. 95 % non-condensing\u003c\/li\u003e\n\u003cli\u003eDC Connection: Screw terminals\u003c\/li\u003e\n\u003cli\u003eMaximum Cable Cross-Section: 16 mm² AWG6\u003c\/li\u003e\n\u003cli\u003eWeight: 1.3 kg (3 lb)\u003c\/li\u003e\n\u003cli\u003eDimensions (H x W x D): 130 x 186 x 70 mm (5.1 x 7.3 x 2.8 inch)\u003c\/li\u003e\n\u003cli\u003eSafety Standards: EN 60950\u003c\/li\u003e\n\u003cli\u003eImmunity Standards: EN 61000-6-2, EN 61000-6-1, EN 55014-2\u003c\/li\u003e\n\u003cli\u003eAutomotive Directive Standards: ECE R10-5\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cimg alt=\"Warning\" src=\"https:\/\/productimageserver.com\/prop65\/6pt.png\"\u003e\u003cstrong\u003eWARNING:\u003c\/strong\u003e This product can expose you to chemicals which are known to the State of California to cause cancer, birth defects or other reproductive harm. For more information go to \u003ca href=\"http:\/\/P65Warnings.ca.gov\"\u003eP65Warnings.ca.gov\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cmeta charset=\"utf-8\"\u003e\u003cstrong\u003eOnce purchased and in use, this product is non-returnable.\u003c\/strong\u003e\u003c\/p\u003e\n\u003c!--- cis2:m2lsnZdp ---\u003e\n\u003cp\u003e\u003cb\u003eSpecifications:\u003c\/b\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eCharger Input - Voltage: 24v\u003c\/li\u003e\n\u003cli\u003eCharger Output - Amps: 30a\u003c\/li\u003e\n\u003cli\u003eCharger Output Voltage: 12v\u003c\/li\u003e\n\u003cli\u003eBox Dimensions: 4\"H x 6\"W x 8\"L WT: 4.1 lbs\u003c\/li\u003e\n\u003cli\u003eUPC: 8719076038849\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eProduct Manual\u003c\/h3\u003e\n\u003ch4\u003e\n\u003ca href=\"https:\/\/productimageserver.com\/literature\/quickGuide\/82877QG.pdf\" target=\"_blank\"\u003eQuick Guide (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/productimageserver.com\/literature\/ownersManual\/82877OM.pdf\" target=\"_blank\"\u003eOwner's Manual (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/productimageserver.com\/literature\/brochure\/82877BR.pdf\" target=\"_blank\"\u003eBrochure (pdf)\u003c\/a\u003e\n\u003c\/h4\u003e\n\u003ch3\u003eProduct Warranty\u003c\/h3\u003e\n\u003ch2\u003e\u003cspan style=\"text-decoration: underline;\"\u003eVictron Energy Product Warranty\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cmeta charset=\"utf-8\"\u003eVictron Energy warrants its products to be free from defects in workmanship and materials for a period of 5 years from the date of purchase by the end-user, with a maximum of 66 months from the Victron Energy invoice date. Exceptions on this are: lead-acid batteries; 2 years from date of purchase by the end-user, with a maximum of 30 months from the Victron Energy invoice date, Lithium batteries; 3 years from date of purchase by the end-user. In addition to this, proof of correct battery usage is required when making a battery warranty claim.\u003c\/p\u003e\n\u003cp\u003eFor a 10% surcharge on the net price for products that came with a 5-year warranty, an additional 5 years of warranty can be purchased, bringing the total warranty to 10 years. Warranty extensions need to be applied for ultimately one year before expiration of the original term.\u003c\/p\u003e\n\u003cp\u003eDuring the warranty period, Victron Energy will, at its discretion, repair, replace or credit the defective product free of charge. The warranty does not include performing or reimbursing de‐installation, transportation, and re‐installation. This warranty will be considered void if the unit has suffered any physical damage or alteration, either internally or externally, and does not cover damages arising from improper use like:\u003c\/p\u003e\n\u003cp\u003e• Reverse of battery polarity.\u003c\/p\u003e\n\u003cp\u003e• Inadequate connection.\u003c\/p\u003e\n\u003cp\u003e• Mechanical shock or deformation.\u003c\/p\u003e\n\u003cp\u003e• Contact with liquid or oxidation by condensation.\u003c\/p\u003e\n\u003cp\u003e• Use in an inappropriate environment(dust, corrosive vapor, humidity, high temperature, biological infestation...). \u003c\/p\u003e\n\u003cp\u003e• Breakage or damage due to lightning.\u003c\/p\u003e\n\u003cp\u003e• Connection terminals and screws destroyed or other damages, like overheat, due to insufficient tightening.\u003c\/p\u003e\n\u003cp\u003e• For any electronic breakage except due to lightning (reverse polarity, over‐voltage due to external cause), the state of the internal control diode and\/or the input\/output X and Y capacitors determine the warranty.\u003c\/p\u003e\n\u003cp\u003eThis warranty will not apply where the product has been misused, neglected, improperly installed, or repaired by anyone else than Victron Energy or one of its authorized Repair Centres. In order to qualify for the warranty, the product must not be disassembled or modified.\u003c\/p\u003e\n\u003cp\u003eRepair, replacement or credit are our sole remedies and Victron Energy shall not be liable for damages, whether direct, incidental, special, or consequential, even caused by negligence or fault.\u003c\/p\u003e\n\u003cp\u003eVictron Energy owns all parts removed from repaired products. Victron Energy uses new or reconditioned parts made by various manufacturers when performing warranty repairs or building replacement products. If Victron Energy repairs or replaces a part of a product, its warranty term is not extended.\u003c\/p\u003e\n\u003cp\u003eAll remedies and the measure for damages are limited to the above.\u003c\/p\u003e\n\u003cp\u003eVictron Energy shall in no event be liable for consequential, incidental, contingent or special damages, even if having been advised of the probability of such damages. Any and all other warranties expressed or implied arising by law, course of dealing, course of performance, usage of trade or otherwise, including but not limited to implied warranties of merchantability and fitness for a particular purpose, are limited in duration to a period of five (5) years from the date of purchase, with the exception of batteries. For lead acid batteries a two (2) year period applies and for lithium batteries a three (3) year period applies.\u003c\/p\u003e\n\u003ch3\u003eProduct FAQs\u003c\/h3\u003e\n\u003cp\u003eN\/A\u003c\/p\u003e","brand":"Victron Energy","offers":[{"title":"Default Title","offer_id":50359611883803,"sku":"OGL-82877","price":201.45,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0724\/2026\/2171\/files\/82877XL.jpg?v=1749567453"},{"product_id":"victron-orion-tr-dc-dc-converter-48-vdc-to-12-vdc-30amp-isolated-ori481240110","title":"Victron Energy Orion-TR DC-DC Converter - 48 VDC to 12 VDC - 30AMP Isolated [ORI481240110]","description":"\u003ch2\u003e\u003cspan style=\"text-decoration: underline;\"\u003eVictron Energy Orion-TR DC-DC Converter - 48 VDC to 12 VDC - 30AMP Isolated [ORI481240110]\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eIsolated Model - separate in and out (-) leads \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRemote On\/Off Terminal\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe remote on\/off terminal eliminates the need for a high current switch in the input wiring. The remote on\/off can be operated with a low power switch or for example the engine run\/stop switch. \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAll Models Are Short Circuit Proof and Can Be Paralleled to Increase Output Current\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAn unlimited number of units can be connected in parallel.  \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHigh Temperature Protected \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe output current will reduce at high ambient temperatures.  \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIP43 Protection \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWhen installed with the screw terminals oriented downward.  \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eScrew Terminals \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo special tools are needed for installation.  \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInput Fuse (not replaceable) \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eOn 12 V and 24 V input models only.  \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAdjustable Output Voltage \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNot intended for battery charging (consider using an Orion-Tr Smart for battery charging).\u003c\/p\u003e\n\u003ch3\u003eProduct Specifications\u003c\/h3\u003e\n\u003ch2\u003e\n\u003cspan style=\"text-decoration: underline;\"\u003eVictron Energy Orion-TR DC-DC Converter - 48 VDC to 12 VDC - 30AMP Isolated [ORI481240110] \u003cmeta charset=\"utf-8\"\u003e\u003c\/span\u003e\u003cspan style=\"text-decoration: underline;\"\u003eProduct Specifications\u003c\/span\u003e\n\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eInput Voltage Range: 40-70 V\u003c\/li\u003e\n\u003cli\u003eUnder Voltage Shut Down: 28 V\u003c\/li\u003e\n\u003cli\u003eUnder Voltage Restart: 30 V\u003c\/li\u003e\n\u003cli\u003eNominal Output Voltage: 12.2 V\u003c\/li\u003e\n\u003cli\u003eOutput Voltage Adjust Range: 10-15 V\u003c\/li\u003e\n\u003cli\u003eOutput Voltage Tolerance: +\/- 0,2 V\u003c\/li\u003e\n\u003cli\u003eOutput Noise: 2 mV rms\u003c\/li\u003e\n\u003cli\u003eCont. Output Current at Nominal Output Voltage and 40 Degrees C: 30 A\u003c\/li\u003e\n\u003cli\u003eMaximum Output Current (10 S) at Nominal Output Voltage: 40 A\u003c\/li\u003e\n\u003cli\u003eShort Circuit Output Current: 60 A\u003c\/li\u003e\n\u003cli\u003eCont. Output Power at 25 Degrees C: 430 W\u003c\/li\u003e\n\u003cli\u003eCont. Output Power at 40 Degrees C: 360 W\u003c\/li\u003e\n\u003cli\u003eEfficiency: 87 %\u003c\/li\u003e\n\u003cli\u003eNo Load Input Current (2): \u0026lt; 80 mA \u003c\/li\u003e\n\u003cli\u003eGalvanic Isolation: 200 VDC between input, output, and case\u003c\/li\u003e\n\u003cli\u003eOperating Temperature Range: -20 to +55 Degrees C (derate 3 % per °C above 40 °C)\u003c\/li\u003e\n\u003cli\u003eHumidity: Max. 95 % non-condensing\u003c\/li\u003e\n\u003cli\u003eDC Connection: Screw terminals\u003c\/li\u003e\n\u003cli\u003eMaximum Cable Cross-Section: 16 mm² AWG6\u003c\/li\u003e\n\u003cli\u003eWeight: 1.6 kg (3.5 lb)\u003c\/li\u003e\n\u003cli\u003eDimensions (H x W x D): 130 x 186 x 70 mm (5.1 x 7.3 x 2.8 inch)\u003c\/li\u003e\n\u003cli\u003eSafety Standards: EN 60950\u003c\/li\u003e\n\u003cli\u003eImmunity Standards: EN 61000-6-3, EN 61000-6-1, EN 55014-2\u003c\/li\u003e\n\u003cli\u003eAutomotive Directive Standards: ECE R10-5\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cimg alt=\"Warning\" src=\"https:\/\/productimageserver.com\/prop65\/6pt.png\"\u003e\u003cstrong\u003eWARNING:\u003c\/strong\u003e This product can expose you to chemicals which are known to the State of California to cause cancer, birth defects or other reproductive harm. For more information go to \u003ca href=\"http:\/\/P65Warnings.ca.gov\"\u003eP65Warnings.ca.gov\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cmeta charset=\"utf-8\"\u003e\u003cstrong\u003eOnce purchased and in use, this product is non-returnable.\u003c\/strong\u003e\u003c\/p\u003e\n\u003c!--- cis2:m2lsnZdp ---\u003e\n\u003ch3\u003eProduct Manual\u003c\/h3\u003e\n\u003ch4\u003e\n\u003ca href=\"https:\/\/productimageserver.com\/literature\/quickGuide\/82878QG.pdf\" target=\"_blank\"\u003eQuick Guide (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/productimageserver.com\/literature\/ownersManual\/82878OM.pdf\" target=\"_blank\"\u003eOwner's Manual (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/productimageserver.com\/literature\/brochure\/82878BR.pdf\" target=\"_blank\"\u003eBrochure (pdf)\u003c\/a\u003e\n\u003c\/h4\u003e\n\u003ch3\u003eProduct Warranty\u003c\/h3\u003e\n\u003ch2\u003e\u003cspan style=\"text-decoration: underline;\"\u003eVictron Energy Product Warranty\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cmeta charset=\"utf-8\"\u003eVictron Energy warrants its products to be free from defects in workmanship and materials for a period of 5 years from the date of purchase by the end-user, with a maximum of 66 months from the Victron Energy invoice date. Exceptions on this are: lead-acid batteries; 2 years from date of purchase by the end-user, with a maximum of 30 months from the Victron Energy invoice date, Lithium batteries; 3 years from date of purchase by the end-user. In addition to this, proof of correct battery usage is required when making a battery warranty claim.\u003c\/p\u003e\n\u003cp\u003eFor a 10% surcharge on the net price for products that came with a 5-year warranty, an additional 5 years of warranty can be purchased, bringing the total warranty to 10 years. Warranty extensions need to be applied for ultimately one year before expiration of the original term.\u003c\/p\u003e\n\u003cp\u003eDuring the warranty period, Victron Energy will, at its discretion, repair, replace or credit the defective product free of charge. The warranty does not include performing or reimbursing de‐installation, transportation, and re‐installation. This warranty will be considered void if the unit has suffered any physical damage or alteration, either internally or externally, and does not cover damages arising from improper use like:\u003c\/p\u003e\n\u003cp\u003e• Reverse of battery polarity.\u003c\/p\u003e\n\u003cp\u003e• Inadequate connection.\u003c\/p\u003e\n\u003cp\u003e• Mechanical shock or deformation.\u003c\/p\u003e\n\u003cp\u003e• Contact with liquid or oxidation by condensation.\u003c\/p\u003e\n\u003cp\u003e• Use in an inappropriate environment(dust, corrosive vapor, humidity, high temperature, biological infestation...). \u003c\/p\u003e\n\u003cp\u003e• Breakage or damage due to lightning.\u003c\/p\u003e\n\u003cp\u003e• Connection terminals and screws destroyed or other damages, like overheat, due to insufficient tightening.\u003c\/p\u003e\n\u003cp\u003e• For any electronic breakage except due to lightning (reverse polarity, over‐voltage due to external cause), the state of the internal control diode and\/or the input\/output X and Y capacitors determine the warranty.\u003c\/p\u003e\n\u003cp\u003eThis warranty will not apply where the product has been misused, neglected, improperly installed, or repaired by anyone else than Victron Energy or one of its authorized Repair Centres. In order to qualify for the warranty, the product must not be disassembled or modified.\u003c\/p\u003e\n\u003cp\u003eRepair, replacement or credit are our sole remedies and Victron Energy shall not be liable for damages, whether direct, incidental, special, or consequential, even caused by negligence or fault.\u003c\/p\u003e\n\u003cp\u003eVictron Energy owns all parts removed from repaired products. Victron Energy uses new or reconditioned parts made by various manufacturers when performing warranty repairs or building replacement products. If Victron Energy repairs or replaces a part of a product, its warranty term is not extended.\u003c\/p\u003e\n\u003cp\u003eAll remedies and the measure for damages are limited to the above.\u003c\/p\u003e\n\u003cp\u003eVictron Energy shall in no event be liable for consequential, incidental, contingent or special damages, even if having been advised of the probability of such damages. Any and all other warranties expressed or implied arising by law, course of dealing, course of performance, usage of trade or otherwise, including but not limited to implied warranties of merchantability and fitness for a particular purpose, are limited in duration to a period of five (5) years from the date of purchase, with the exception of batteries. For lead acid batteries a two (2) year period applies and for lithium batteries a three (3) year period applies.\u003c\/p\u003e\n\u003ch3\u003eProduct FAQs\u003c\/h3\u003e\n\u003cp\u003eN\/A\u003c\/p\u003e","brand":"Victron Energy","offers":[{"title":"Default Title","offer_id":50359611916571,"sku":"OGL-82878","price":201.45,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0724\/2026\/2171\/files\/82878XL.jpg?v=1749567454"},{"product_id":"victron-energy-orion-tr-smart-24-12-30-30a-360w-isolated-dc-dc-charger-or-power-supply-ori241236120","title":"Victron Energy Orion-TR Smart 24\/12-30 30A (360W) Isolated DC-DC Charger or Power Supply [ORI241236120]","description":"\u003ch2\u003e\u003cspan style=\"text-decoration: underline;\"\u003eVictron Energy Orion-TR Smart 24\/12-30 30A (360W) Isolated DC-DC Charger or Power Supply [ORI241236120]\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003eThe Orion-Tr Smart isolated DC-DC charger serves as a DC-DC battery charger or a power supply (also designed for use as a constant voltage source), offering a wide input and output voltage range. This is especially significant in the case of vehicles with a Euro 5 or Euro 6 smart alternator, which often supplies too low charging voltage even when the engine is running or when extended cable lengths, as is often the case in boats and RVs, lead to voltage drops. In such scenarios, precise and controlled charging is imperative to fully charge the service battery while protecting the starter\/input battery from discharge.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBluetooth Smart Enabled\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eAny Bluetooth-enabled smartphone, tablet, or other device can be used to monitor, change settings, and update the charger when new software features become available\u003c\/li\u003e\n\u003cli\u003eInstant Readout: The VictronConnect App can display key data, including warnings and alarms, on the device list page without the need to connect to the product\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eFully programmable\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eBattery charge algorithm (configurable) or fixed output. \u003c\/li\u003e\n\u003cli\u003eSmart Alternator Compatibility: engine running detection mechanism\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eAdaptive 3-Stage Charge Algorithm: Bulk – Absorption – Float\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eFor lead-acid batteries, it is important that during shallow discharges the absorption time is kept short to prevent overcharging of the battery. After a deep discharge, the absorption time is automatically increased to make sure that the battery is completely recharged\u003c\/li\u003e\n\u003cli\u003eFor lithium batteries, the absorption time is fixed; the default is 2 hours\u003c\/li\u003e\n\u003cli\u003eAlternatively, a fixed output voltage can be chosen\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSuitable for Use in Vehicles with a Smart Alternator (Euro 5 and Euro 6 Engines)\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe built-in engine shutdown detection will stop the converter when the engine is not running. This prevents unwanted discharge of the starter battery (see manual for details).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRemote On\/Off\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA remote on\/off switch or relay contact can be connected to a two-pole connector. Alternatively, the H terminal (right) of the two-pole connector can be switched to battery plus, or the L terminal (left) of the two-pole connector can be switched to battery minus (or the chassis of a vehicle, for example).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAll Models Are Short Circuit Proof and Can Be Paralleled to Increase Output Current\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAn unlimited number of units can be connected in parallel.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHigh Temperature Protected\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe output current will reduce at high ambient temperatures.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIP43 Protection\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWhen installed with the screw terminals oriented downward.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eScrew Terminals\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo special tools are needed for installation. Input fuse (not replaceable) \u003c\/p\u003e\n\u003cp\u003e*Input fuse (not replaceable) \u003c\/p\u003e\n\u003ch3\u003eProduct Specifications\u003c\/h3\u003e\n\u003ch2\u003e\n\u003cspan style=\"text-decoration: underline;\"\u003eVictron Energy Orion-TR Smart 24\/12-30 30A (360W) Isolated DC-DC Charger or Power Supply [ORI241236120] \u003c\/span\u003e\u003cspan style=\"text-decoration: underline;\"\u003eProduct Specifications\u003c\/span\u003e\n\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eInput Voltage Range: 20-35 V\u003c\/li\u003e\n\u003cli\u003eUnder Voltage Shut Down: 14 V\u003c\/li\u003e\n\u003cli\u003eUnder Voltage Restart: 15 V\u003c\/li\u003e\n\u003cli\u003eNominal Output Voltage: 12.2 V\u003c\/li\u003e\n\u003cli\u003eOutput Voltage Adjust Range: 10-15 V\u003c\/li\u003e\n\u003cli\u003eOutput Voltage Tolerance: +\/- 0,2 V\u003c\/li\u003e\n\u003cli\u003eOutput Noise: 2 mV rms\u003c\/li\u003e\n\u003cli\u003eCont. Output Current at Nominal Output Voltage and 40 Degrees C: 30 A\u003c\/li\u003e\n\u003cli\u003eMaximum Output Current (10 S) at Nominal Output Voltage minus 20%: 45 A\u003c\/li\u003e\n\u003cli\u003eShort Circuit Output Current: 60 A\u003c\/li\u003e\n\u003cli\u003eCont. Output Power at 25 Degrees C: 430 W\u003c\/li\u003e\n\u003cli\u003eCont. Output Power at 40 Degrees C: 360 W\u003c\/li\u003e\n\u003cli\u003eEfficiency: 88 %\u003c\/li\u003e\n\u003cli\u003eNo Load Input Current (2): \u0026lt; 100 mA \u003c\/li\u003e\n\u003cli\u003eStandby Current: Less than 1A\u003c\/li\u003e\n\u003cli\u003eCan Be Used as Power Supply: Yes, output voltage can be set with Bluetooth \u003c\/li\u003e\n\u003cli\u003eGalvanic Isolation: 200 VDC between input, output, and case \u003c\/li\u003e\n\u003cli\u003eOperating Temperature Range -20 to +55 °C (derate 3 % per °C above 40 °C) \u003c\/li\u003e\n\u003cli\u003eHumidity: Max. 95 % non-condensing \u003c\/li\u003e\n\u003cli\u003eDC Connection: Screw terminals \u003c\/li\u003e\n\u003cli\u003eMaximum Cable Cross-Section: 16 mm²  AWG6 \u003c\/li\u003e\n\u003cli\u003eWeight: 1,6 kg (3.5 lb) \u003c\/li\u003e\n\u003cli\u003eDimensions (H x W x D):130 x 186 x 70 mm  (5.1 x 7.3 x 2.8 inch) \u003c\/li\u003e\n\u003cli\u003eProtection Category IP43 (electronic components), IP22 (connection area) \u003c\/li\u003e\n\u003cli\u003eSafety Standards: EN 60950\u003c\/li\u003e\n\u003cli\u003eEmission\/Immunity Standards: EN 61000-6-3, EN 55014-1 \/ EN 61000-6-2, EN 61000-6-1, EN 55014-2\u003c\/li\u003e\n\u003cli\u003eAutomotive Directive Standards: ECE R10-5\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cimg alt=\"Warning\" src=\"https:\/\/productimageserver.com\/prop65\/6pt.png\"\u003e\u003cstrong\u003eWARNING:\u003c\/strong\u003e This product can expose you to chemicals which are known to the State of California to cause cancer, birth defects or other reproductive harm. For more information go to \u003ca href=\"http:\/\/P65Warnings.ca.gov\"\u003eP65Warnings.ca.gov\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cmeta charset=\"utf-8\"\u003e\u003cstrong\u003eOnce purchased and in use, this product is non-returnable.\u003c\/strong\u003e\u003c\/p\u003e\n\u003c!--- cis2:m2lsnZdp ---\u003e\n\u003cp\u003e\u003cb\u003eSpecifications:\u003c\/b\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eCharger Input - Voltage: 24v\u003c\/li\u003e\n\u003cli\u003eCharger Output - Amps: 30a\u003c\/li\u003e\n\u003cli\u003eCharger Output Voltage: 12v\u003c\/li\u003e\n\u003cli\u003eBox Dimensions: 4\"H x 6\"W x 9\"L WT: 4.4 lbs\u003c\/li\u003e\n\u003cli\u003eUPC: 8719076047711\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eProduct Manual\u003c\/h3\u003e\n\u003ch4\u003e\u003ca href=\"https:\/\/productimageserver.com\/literature\/quickGuide\/84225QG.pdf\" target=\"_blank\"\u003eQuick Guide (pdf)\u003c\/a\u003e\u003c\/h4\u003e\n\u003ch3\u003eProduct Warranty\u003c\/h3\u003e\n\u003ch2\u003e\u003cspan style=\"text-decoration: underline;\"\u003eVictron Energy Product Warranty\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cmeta charset=\"utf-8\"\u003eVictron Energy warrants its products to be free from defects in workmanship and materials for a period of 5 years from the date of purchase by the end-user, with a maximum of 66 months from the Victron Energy invoice date. Exceptions on this are: lead-acid batteries; 2 years from date of purchase by the end-user, with a maximum of 30 months from the Victron Energy invoice date, Lithium batteries; 3 years from date of purchase by the end-user. In addition to this, proof of correct battery usage is required when making a battery warranty claim.\u003c\/p\u003e\n\u003cp\u003eFor a 10% surcharge on the net price for products that came with a 5-year warranty, an additional 5 years of warranty can be purchased, bringing the total warranty to 10 years. Warranty extensions need to be applied for ultimately one year before expiration of the original term.\u003c\/p\u003e\n\u003cp\u003eDuring the warranty period, Victron Energy will, at its discretion, repair, replace or credit the defective product free of charge. The warranty does not include performing or reimbursing de‐installation, transportation, and re‐installation. This warranty will be considered void if the unit has suffered any physical damage or alteration, either internally or externally, and does not cover damages arising from improper use like:\u003c\/p\u003e\n\u003cp\u003e• Reverse of battery polarity.\u003c\/p\u003e\n\u003cp\u003e• Inadequate connection.\u003c\/p\u003e\n\u003cp\u003e• Mechanical shock or deformation.\u003c\/p\u003e\n\u003cp\u003e• Contact with liquid or oxidation by condensation.\u003c\/p\u003e\n\u003cp\u003e• Use in an inappropriate environment(dust, corrosive vapor, humidity, high temperature, biological infestation...). \u003c\/p\u003e\n\u003cp\u003e• Breakage or damage due to lightning.\u003c\/p\u003e\n\u003cp\u003e• Connection terminals and screws destroyed or other damages, like overheat, due to insufficient tightening.\u003c\/p\u003e\n\u003cp\u003e• For any electronic breakage except due to lightning (reverse polarity, over‐voltage due to external cause), the state of the internal control diode and\/or the input\/output X and Y capacitors determine the warranty.\u003c\/p\u003e\n\u003cp\u003eThis warranty will not apply where the product has been misused, neglected, improperly installed, or repaired by anyone else than Victron Energy or one of its authorized Repair Centres. In order to qualify for the warranty, the product must not be disassembled or modified.\u003c\/p\u003e\n\u003cp\u003eRepair, replacement or credit are our sole remedies and Victron Energy shall not be liable for damages, whether direct, incidental, special, or consequential, even caused by negligence or fault.\u003c\/p\u003e\n\u003cp\u003eVictron Energy owns all parts removed from repaired products. Victron Energy uses new or reconditioned parts made by various manufacturers when performing warranty repairs or building replacement products. If Victron Energy repairs or replaces a part of a product, its warranty term is not extended.\u003c\/p\u003e\n\u003cp\u003eAll remedies and the measure for damages are limited to the above.\u003c\/p\u003e\n\u003cp\u003eVictron Energy shall in no event be liable for consequential, incidental, contingent or special damages, even if having been advised of the probability of such damages. Any and all other warranties expressed or implied arising by law, course of dealing, course of performance, usage of trade or otherwise, including but not limited to implied warranties of merchantability and fitness for a particular purpose, are limited in duration to a period of five (5) years from the date of purchase, with the exception of batteries. For lead acid batteries a two (2) year period applies and for lithium batteries a three (3) year period applies.\u003c\/p\u003e\n\u003ch3\u003eProduct FAQs\u003c\/h3\u003e\n\u003cp\u003eN\/A\u003c\/p\u003e","brand":"Victron Energy","offers":[{"title":"Default Title","offer_id":50359620403483,"sku":"OGL-84225","price":243.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0724\/2026\/2171\/files\/84225XL.jpg?v=1749567715"},{"product_id":"victron-orion-tr-smart-24-12-30-30a-360w-non-isolated-dc-dc-charger-or-power-supply-ori241236140","title":"Victron Energy Orion-TR Smart 24\/12-30 30A (360W) Non-Isolated DC-DC Charger or Power Supply [ORI241236140]","description":"\u003ch2\u003e\u003cspan style=\"text-decoration: underline;\"\u003eVictron Energy Orion-TR Smart 24\/12-30 30A (360W) Non-Isolated DC-DC Charger or Power Supply [ORI241236140]\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003eThe Orion-Tr Smart DC-DC charger is a professional DC to DC adaptive 3-stage charger with built-in Bluetooth.\u003c\/p\u003e\n\u003cp\u003eFor use in dual battery systems in vehicles or on boats where the alternator and the start battery are used to charge the service battery. The unit can be monitored and programmed via Bluetooth and can be remotely controlled via a remote on\/off switch.\u003c\/p\u003e\n\u003cp\u003eThe Orion Tr-Smart charger can be used in 12V or 24V systems and is suitable for both lead acid and lithium batteries. Models are available up to 400W and unlimited multiple units can be connected in parallel to increase output power.\u003c\/p\u003e\n\u003cp\u003eSuitable for high temperatures up to 55°C with a full rated output up to 40°C.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eVictronConnect\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eVictronConnect lets you get live status information and configure any Victron products which either have Bluetooth built-in, or are connected to a VE.Direct Bluetooth Smart Dongle. \u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.victronenergy.com\/upload\/documents\/20150209_Warranty_final_en.pdf\" rel=\"noopener noreferrer\" target=\"_blank\"\u003eWarranty Info\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/productimageserver.com\/prop65\/6pt.png\" alt=\"Warning\"\u003e\u003cstrong\u003eWARNING:\u003c\/strong\u003e This product can expose you to chemicals which are known to the State of California to cause cancer, birth defects or other reproductive harm. For more information go to \u003ca href=\"http:\/\/P65Warnings.ca.gov\"\u003eP65Warnings.ca.gov\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cmeta charset=\"utf-8\"\u003e\u003cstrong\u003eOnce purchased and in use, this product is non-returnable.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003eProduct Specifications\u003c\/h3\u003e\n\u003ch2\u003e\n\u003cspan style=\"text-decoration: underline;\"\u003eVictron Energy Orion-TR Smart 24\/12-30 30A (360W) Non-Isolated DC-DC Charger or Power Supply [ORI241236140] \u003c\/span\u003e\u003cspan style=\"text-decoration: underline;\"\u003eProduct Specifications\u003c\/span\u003e\n\u003c\/h2\u003e\n\u003c!--- cis2:m2lsnZdp ---\u003e\n\u003cp data-start=\"645\" data-end=\"678\"\u003e\u003cstrong data-start=\"649\" data-end=\"678\"\u003eElectrical Specifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"679\" data-end=\"1023\"\u003e\n\u003cli data-start=\"679\" data-end=\"724\"\u003e\n\u003cp data-start=\"681\" data-end=\"724\"\u003eCharger Input Voltage: 24V (range 16–35V)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"725\" data-end=\"768\"\u003e\n\u003cp data-start=\"727\" data-end=\"768\"\u003eOutput Voltage: 12V (adjustable 10–15V)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"769\" data-end=\"824\"\u003e\n\u003cp data-start=\"771\" data-end=\"824\"\u003eContinuous Output Current: 30A (up to 360W at 40°C)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"825\" data-end=\"866\"\u003e\n\u003cp data-start=\"827\" data-end=\"866\"\u003ePeak Output Current (10 seconds): 45A\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"867\" data-end=\"897\"\u003e\n\u003cp data-start=\"869\" data-end=\"897\"\u003eShort-Circuit Current: 60A\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"898\" data-end=\"918\"\u003e\n\u003cp data-start=\"900\" data-end=\"918\"\u003eEfficiency: ~88%\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"919\" data-end=\"940\"\u003e\n\u003cp data-start=\"921\" data-end=\"940\"\u003eCharging Banks: 1\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"941\" data-end=\"957\"\u003e\n\u003cp data-start=\"943\" data-end=\"957\"\u003ePortable: No\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"958\" data-end=\"1023\"\u003e\n\u003cp data-start=\"960\" data-end=\"1023\"\u003eBattery Compatibility: Lead-acid (AGM, GEL, Flooded), Lithium\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1030\" data-end=\"1050\"\u003e\u003cstrong data-start=\"1034\" data-end=\"1050\"\u003eKey Features\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1051\" data-end=\"1404\"\u003e\n\u003cli data-start=\"1051\" data-end=\"1106\"\u003e\n\u003cp data-start=\"1053\" data-end=\"1106\"\u003eAdaptive 3-stage charging (Bulk, Absorption, Float)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1107\" data-end=\"1168\"\u003e\n\u003cp data-start=\"1109\" data-end=\"1168\"\u003eBluetooth Smart built-in for monitoring and configuration\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1169\" data-end=\"1224\"\u003e\n\u003cp data-start=\"1171\" data-end=\"1224\"\u003eSupports remote on\/off switch or ignition detection\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1225\" data-end=\"1278\"\u003e\n\u003cp data-start=\"1227\" data-end=\"1278\"\u003eCan be connected in parallel for increased output\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1279\" data-end=\"1345\"\u003e\n\u003cp data-start=\"1281\" data-end=\"1345\"\u003eFull protection: short circuit, overload, and over-temperature\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1346\" data-end=\"1404\"\u003e\n\u003cp data-start=\"1348\" data-end=\"1404\"\u003eTemperature-compensated charging (via external sensor)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1411\" data-end=\"1449\"\u003e\u003cstrong data-start=\"1415\" data-end=\"1449\"\u003ePhysical \u0026amp; Environmental Specs\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1450\" data-end=\"1790\"\u003e\n\u003cli data-start=\"1450\" data-end=\"1489\"\u003e\n\u003cp data-start=\"1452\" data-end=\"1489\"\u003eCooling: Fanless natural convection\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1490\" data-end=\"1554\"\u003e\n\u003cp data-start=\"1492\" data-end=\"1554\"\u003eEnclosure Rating: IP43 (electronics), IP22 (connection area)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1555\" data-end=\"1617\"\u003e\n\u003cp data-start=\"1557\" data-end=\"1617\"\u003eOperating Temperature: –20°C to +55°C (derates above 40°C)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1618\" data-end=\"1666\"\u003e\n\u003cp data-start=\"1620\" data-end=\"1666\"\u003eMounting Orientation: Horizontal or vertical\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1667\" data-end=\"1729\"\u003e\n\u003cp data-start=\"1669\" data-end=\"1729\"\u003eDimensions: 4\" H × 6\" W × 8\" L (approx. 130 × 186 × 80 mm)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1730\" data-end=\"1767\"\u003e\n\u003cp data-start=\"1732\" data-end=\"1767\"\u003eWeight: Approx. 4.25 lbs (1.6 kg)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1768\" data-end=\"1790\"\u003e\n\u003cp data-start=\"1770\" data-end=\"1790\"\u003eUPC: 8719076048978\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eProduct Manual\u003c\/h3\u003e\n\u003ch4\u003e\n\u003ca href=\"https:\/\/productimageserver.com\/literature\/quickGuide\/84228QG.pdf\" target=\"_blank\"\u003eQuick Guide (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/productimageserver.com\/literature\/brochure\/84228BR.pdf\" target=\"_blank\"\u003eBrochure (pdf)\u003c\/a\u003e\n\u003c\/h4\u003e\n\u003ch3\u003eProduct Warranty\u003c\/h3\u003e\n\u003ch2\u003e\u003cspan style=\"text-decoration: underline;\"\u003eVictron Energy Product Warranty\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cmeta charset=\"utf-8\"\u003eVictron Energy warrants its products to be free from defects in workmanship and materials for a period of 5 years from the date of purchase by the end-user, with a maximum of 66 months from the Victron Energy invoice date. Exceptions on this are: lead-acid batteries; 2 years from date of purchase by the end-user, with a maximum of 30 months from the Victron Energy invoice date, Lithium batteries; 3 years from date of purchase by the end-user. In addition to this, proof of correct battery usage is required when making a battery warranty claim.\u003c\/p\u003e\n\u003cp\u003eFor a 10% surcharge on the net price for products that came with a 5-year warranty, an additional 5 years of warranty can be purchased, bringing the total warranty to 10 years. Warranty extensions need to be applied for ultimately one year before expiration of the original term.\u003c\/p\u003e\n\u003cp\u003eDuring the warranty period, Victron Energy will, at its discretion, repair, replace or credit the defective product free of charge. The warranty does not include performing or reimbursing de‐installation, transportation, and re‐installation. This warranty will be considered void if the unit has suffered any physical damage or alteration, either internally or externally, and does not cover damages arising from improper use like:\u003c\/p\u003e\n\u003cp\u003e• Reverse of battery polarity.\u003c\/p\u003e\n\u003cp\u003e• Inadequate connection.\u003c\/p\u003e\n\u003cp\u003e• Mechanical shock or deformation.\u003c\/p\u003e\n\u003cp\u003e• Contact with liquid or oxidation by condensation.\u003c\/p\u003e\n\u003cp\u003e• Use in an inappropriate environment(dust, corrosive vapor, humidity, high temperature, biological infestation...). \u003c\/p\u003e\n\u003cp\u003e• Breakage or damage due to lightning.\u003c\/p\u003e\n\u003cp\u003e• Connection terminals and screws destroyed or other damages, like overheat, due to insufficient tightening.\u003c\/p\u003e\n\u003cp\u003e• For any electronic breakage except due to lightning (reverse polarity, over‐voltage due to external cause), the state of the internal control diode and\/or the input\/output X and Y capacitors determine the warranty.\u003c\/p\u003e\n\u003cp\u003eThis warranty will not apply where the product has been misused, neglected, improperly installed, or repaired by anyone else than Victron Energy or one of its authorized Repair Centres. In order to qualify for the warranty, the product must not be disassembled or modified.\u003c\/p\u003e\n\u003cp\u003eRepair, replacement or credit are our sole remedies and Victron Energy shall not be liable for damages, whether direct, incidental, special, or consequential, even caused by negligence or fault.\u003c\/p\u003e\n\u003cp\u003eVictron Energy owns all parts removed from repaired products. Victron Energy uses new or reconditioned parts made by various manufacturers when performing warranty repairs or building replacement products. If Victron Energy repairs or replaces a part of a product, its warranty term is not extended.\u003c\/p\u003e\n\u003cp\u003eAll remedies and the measure for damages are limited to the above.\u003c\/p\u003e\n\u003cp\u003eVictron Energy shall in no event be liable for consequential, incidental, contingent or special damages, even if having been advised of the probability of such damages. Any and all other warranties expressed or implied arising by law, course of dealing, course of performance, usage of trade or otherwise, including but not limited to implied warranties of merchantability and fitness for a particular purpose, are limited in duration to a period of five (5) years from the date of purchase, with the exception of batteries. For lead acid batteries a two (2) year period applies and for lithium batteries a three (3) year period applies.\u003c\/p\u003e\n\u003ch3\u003eProduct FAQs\u003c\/h3\u003e\n\u003cp\u003eN\/A\u003c\/p\u003e","brand":"Victron Energy","offers":[{"title":"Default Title","offer_id":50359620501787,"sku":"OGL-84228","price":215.05,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0724\/2026\/2171\/files\/84228XL.jpg?v=1749567716"},{"product_id":"victron-orion-tr-dc-dc-converter-24-vdc-to-24-vdc-280w-12amp-isolated-ori242428110","title":"Victron Energy Orion-TR DC-DC Converter - 24 VDC to 24 VDC - 280W - 12AMP Isolated [ORI242428110]","description":"\u003ch2\u003e\u003cspan style=\"text-decoration: underline;\"\u003eVictron Energy Orion-TR DC-DC Converter - 24 VDC to 24 VDC - 280W - 12AMP Isolated [ORI242428110]\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eIsolated Model - separate in and out (-) leads \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRemote On\/Off Terminal\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe remote on\/off terminal eliminates the need for a high current switch in the input wiring. The remote on\/off can be operated with a low power switch or for example the engine run\/stop switch. \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAll Models Are Short Circuit Proof and Can Be Paralleled to Increase Output Current\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAn unlimited number of units can be connected in parallel.  \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHigh Temperature Protected \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe output current will reduce at high ambient temperatures.  \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIP43 Protection \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWhen installed with the screw terminals oriented downward.  \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eScrew Terminals \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo special tools are needed for installation.  \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInput Fuse (not replaceable) \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eOn 12 V and 24 V input models only.  \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAdjustable Output Voltage \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNot intended for battery charging (consider using an Orion-Tr Smart for battery charging).\u003ca href=\"https:\/\/productimageserver.com\/literature\/brochure\/85368BR.pdf\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cstyle\u003e.embed-container { position: relative; padding-bottom: 56.25%; height: 0; overflow: hidden; max-width: 100%; } .embed-container iframe, .embed-container object, .embed-container embed { position: absolute; top: 0; left: 0; width: 100%; height: 100%; }\u003c\/style\u003e\n\u003cdiv class=\"embed-container\"\u003e\u003ciframe src=\"https:\/\/www.youtube.com\/embed\/naSy08ZhGZE?si=xIdF2WfgfIpkE212\"\u003e\u003c\/iframe\u003e\u003c\/div\u003e\n\u003ch3\u003eProduct Specifications\u003c\/h3\u003e\n\u003ch2\u003e\n\u003cspan style=\"text-decoration: underline;\"\u003eVictron Energy Orion-TR DC-DC Converter - 24 VDC to 24 VDC - 280W - 12AMP Isolated [ORI242428110] \u003cmeta charset=\"utf-8\"\u003e\u003c\/span\u003e\u003cspan style=\"text-decoration: underline;\"\u003eProduct Specifications\u003c\/span\u003e\n\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eInput Voltage Range: 16-35 V\u003c\/li\u003e\n\u003cli\u003eUnder Voltage Shut Down: 14 V\u003c\/li\u003e\n\u003cli\u003eUnder Voltage Restart: 15 V\u003c\/li\u003e\n\u003cli\u003eNominal Output Voltage: 24.2 V\u003c\/li\u003e\n\u003cli\u003eOutput Voltage Adjust Range: 20-30 V\u003c\/li\u003e\n\u003cli\u003eOutput Voltage Tolerance: +\/- 0,2 V\u003c\/li\u003e\n\u003cli\u003eOutput Noise: 2 mV rms\u003c\/li\u003e\n\u003cli\u003eCont. Output Current at Nominal Output Voltage and 40 Degrees C: 12 A\u003c\/li\u003e\n\u003cli\u003eMaximum Output Current (10 S) at Nominal Output Voltage: 15 A\u003c\/li\u003e\n\u003cli\u003eShort Circuit Output Current: 30 A\u003c\/li\u003e\n\u003cli\u003eCont. Output Power at 25 Degrees C: 320 W\u003c\/li\u003e\n\u003cli\u003eCont. Output Power at 40 Degrees C: 280 W\u003c\/li\u003e\n\u003cli\u003eEfficiency: 89 %\u003c\/li\u003e\n\u003cli\u003eNo Load Input Current (2): \u0026lt; 80 mA \u003c\/li\u003e\n\u003cli\u003eGalvanic Isolation: 200 VDC between input, output, and case\u003c\/li\u003e\n\u003cli\u003eOperating Temperature Range: -20 to +55 Degrees C (derate 3 % per °C above 40 °C)\u003c\/li\u003e\n\u003cli\u003eHumidity: Max. 95 % non-condensing\u003c\/li\u003e\n\u003cli\u003eDC Connection: Screw terminals\u003c\/li\u003e\n\u003cli\u003eMaximum Cable Cross-Section: 16 mm² AWG6\u003c\/li\u003e\n\u003cli\u003eWeight: 1.3 kg (3 lb)\u003c\/li\u003e\n\u003cli\u003eDimensions (H x W x D): 130 x 186 x 70 mm (5.1 x 7.3 x 2.8 inch)\u003c\/li\u003e\n\u003cli\u003eSafety Standards: EN 60950\u003c\/li\u003e\n\u003cli\u003eImmunity Standards: EN 61000-6-3, EN 61000-6-1, EN 55014-2\u003c\/li\u003e\n\u003cli\u003eAutomotive Directive Standards: ECE R10-5\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cmeta charset=\"utf-8\"\u003e\u003cstrong\u003eOnce purchased and in use, this product is non-returnable.\u003c\/strong\u003e\u003c\/p\u003e\n\u003c!--- cis2:m2lsnZdp ---\u003e\n\u003ch3\u003eProduct Manual\u003c\/h3\u003e\n\u003ch4\u003e\n\u003ca href=\"https:\/\/productimageserver.com\/literature\/quickGuide\/85368QG.pdf\" target=\"_blank\"\u003eQuick Guide (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/productimageserver.com\/literature\/ownersManual\/85368OM.pdf\" target=\"_blank\"\u003eOwner's Manual (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/productimageserver.com\/literature\/brochure\/85368BR.pdf\" target=\"_blank\"\u003eBrochure (pdf)\u003c\/a\u003e\n\u003c\/h4\u003e\n\u003ch3\u003eProduct Warranty\u003c\/h3\u003e\n\u003ch2\u003e\u003cspan style=\"text-decoration: underline;\"\u003eVictron Energy Product Warranty\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cmeta charset=\"utf-8\"\u003eVictron Energy warrants its products to be free from defects in workmanship and materials for a period of 5 years from the date of purchase by the end-user, with a maximum of 66 months from the Victron Energy invoice date. Exceptions on this are: lead-acid batteries; 2 years from date of purchase by the end-user, with a maximum of 30 months from the Victron Energy invoice date, Lithium batteries; 3 years from date of purchase by the end-user. In addition to this, proof of correct battery usage is required when making a battery warranty claim.\u003c\/p\u003e\n\u003cp\u003eFor a 10% surcharge on the net price for products that came with a 5-year warranty, an additional 5 years of warranty can be purchased, bringing the total warranty to 10 years. Warranty extensions need to be applied for ultimately one year before expiration of the original term.\u003c\/p\u003e\n\u003cp\u003eDuring the warranty period, Victron Energy will, at its discretion, repair, replace or credit the defective product free of charge. The warranty does not include performing or reimbursing de‐installation, transportation, and re‐installation. This warranty will be considered void if the unit has suffered any physical damage or alteration, either internally or externally, and does not cover damages arising from improper use like:\u003c\/p\u003e\n\u003cp\u003e• Reverse of battery polarity.\u003c\/p\u003e\n\u003cp\u003e• Inadequate connection.\u003c\/p\u003e\n\u003cp\u003e• Mechanical shock or deformation.\u003c\/p\u003e\n\u003cp\u003e• Contact with liquid or oxidation by condensation.\u003c\/p\u003e\n\u003cp\u003e• Use in an inappropriate environment(dust, corrosive vapor, humidity, high temperature, biological infestation...). \u003c\/p\u003e\n\u003cp\u003e• Breakage or damage due to lightning.\u003c\/p\u003e\n\u003cp\u003e• Connection terminals and screws destroyed or other damages, like overheat, due to insufficient tightening.\u003c\/p\u003e\n\u003cp\u003e• For any electronic breakage except due to lightning (reverse polarity, over‐voltage due to external cause), the state of the internal control diode and\/or the input\/output X and Y capacitors determine the warranty.\u003c\/p\u003e\n\u003cp\u003eThis warranty will not apply where the product has been misused, neglected, improperly installed, or repaired by anyone else than Victron Energy or one of its authorized Repair Centres. In order to qualify for the warranty, the product must not be disassembled or modified.\u003c\/p\u003e\n\u003cp\u003eRepair, replacement or credit are our sole remedies and Victron Energy shall not be liable for damages, whether direct, incidental, special, or consequential, even caused by negligence or fault.\u003c\/p\u003e\n\u003cp\u003eVictron Energy owns all parts removed from repaired products. Victron Energy uses new or reconditioned parts made by various manufacturers when performing warranty repairs or building replacement products. If Victron Energy repairs or replaces a part of a product, its warranty term is not extended.\u003c\/p\u003e\n\u003cp\u003eAll remedies and the measure for damages are limited to the above.\u003c\/p\u003e\n\u003cp\u003eVictron Energy shall in no event be liable for consequential, incidental, contingent or special damages, even if having been advised of the probability of such damages. Any and all other warranties expressed or implied arising by law, course of dealing, course of performance, usage of trade or otherwise, including but not limited to implied warranties of merchantability and fitness for a particular purpose, are limited in duration to a period of five (5) years from the date of purchase, with the exception of batteries. For lead acid batteries a two (2) year period applies and for lithium batteries a three (3) year period applies.\u003c\/p\u003e\n\u003ch3\u003eProduct FAQs\u003c\/h3\u003e\n\u003cp\u003eN\/A\u003c\/p\u003e","brand":"Victron Energy","offers":[{"title":"Default Title","offer_id":50359622205723,"sku":"OGL-85368","price":113.9,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0724\/2026\/2171\/files\/85368XL.jpg?v=1749567734"},{"product_id":"victron-orion-24-12-70-dc-dc-converter-ip20-ori241270020","title":"Victron Energy Orion 24\/12-70 DC-DC Converter IP20 [ORI241270020]","description":"\u003ch2\u003e\u003cspan style=\"text-decoration: underline;\"\u003eVictron Energy Orion 24\/12-70 DC-DC Converter IP20 [ORI241270020]\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eRemote on\/off the connector\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe remote on\/off eliminates the need for a high current switch in the input wiring. The remote on-off can be operated with a low power switch or by the engine run\/stop switch (see manual).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAll models with adjustable output can also be used as a battery charger\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eFor example to charge a 12 Volt starter or accessory battery in an otherwise 24V system.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAll models with adjustable output can be paralleled to increase output current\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eUp to five units can be connected in parallel.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eEasy to Install\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eDelivery includes four Insulated Fastons Female Crimp 6.3mm (eight Fastons in case of the Orion 24\/12-40).\u003c\/p\u003e\n\u003ch3\u003eProduct Specifications\u003c\/h3\u003e\n\u003ch2\u003e\n\u003cspan style=\"text-decoration: underline;\"\u003eVictron Energy Orion 24\/12-70 DC-DC Converter IP20 [ORI241270020] \u003cmeta charset=\"utf-8\"\u003e\u003c\/span\u003e\u003cspan style=\"text-decoration: underline;\"\u003eProduct Specifications\u003c\/span\u003e\n\u003c\/h2\u003e\n\u003cp data-end=\"166\" data-start=\"148\"\u003e\u003cstrong\u003ePower \u0026amp; Output\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-end=\"520\" data-start=\"167\"\u003e\n\u003cli data-end=\"206\" data-start=\"167\"\u003e\n\u003cp data-end=\"206\" data-start=\"169\"\u003e\u003cstrong data-end=\"193\" data-start=\"169\"\u003eInput Voltage Range:\u003c\/strong\u003e 18–35 V DC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"246\" data-start=\"207\"\u003e\n\u003cp data-end=\"246\" data-start=\"209\"\u003e\u003cstrong data-end=\"236\" data-start=\"209\"\u003eUnder-Voltage Shutdown:\u003c\/strong\u003e 14 V DC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"285\" data-start=\"247\"\u003e\n\u003cp data-end=\"285\" data-start=\"249\"\u003e\u003cstrong data-end=\"275\" data-start=\"249\"\u003eUnder-Voltage Restart:\u003c\/strong\u003e 18 V DC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"357\" data-start=\"286\"\u003e\n\u003cp data-end=\"357\" data-start=\"288\"\u003e\u003cstrong data-end=\"307\" data-start=\"288\"\u003eOutput Voltage:\u003c\/strong\u003e Adjustable from 10–15 V (factory set to 13.2 V)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"397\" data-start=\"358\"\u003e\n\u003cp data-end=\"397\" data-start=\"360\"\u003e\u003cstrong data-end=\"390\" data-start=\"360\"\u003eContinuous Output Current:\u003c\/strong\u003e 70 A\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"458\" data-start=\"398\"\u003e\n\u003cp data-end=\"458\" data-start=\"400\"\u003e\u003cstrong data-end=\"434\" data-start=\"400\"\u003eMaximum Output Current (Peak):\u003c\/strong\u003e 85 A (for 10 seconds)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"482\" data-start=\"459\"\u003e\n\u003cp data-end=\"482\" data-start=\"461\"\u003e\u003cstrong data-end=\"476\" data-start=\"461\"\u003eEfficiency:\u003c\/strong\u003e 92%\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"520\" data-start=\"483\"\u003e\n\u003cp data-end=\"520\" data-start=\"485\"\u003e\u003cstrong data-end=\"510\" data-start=\"485\"\u003eNo-Load Current Draw:\u003c\/strong\u003e \u0026lt; 20 mA\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-end=\"553\" data-start=\"527\"\u003e\u003cstrong\u003eFeatures \u0026amp; Protections\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-end=\"869\" data-start=\"554\"\u003e\n\u003cli data-end=\"627\" data-start=\"554\"\u003e\n\u003cp data-end=\"627\" data-start=\"556\"\u003e\u003cstrong data-end=\"574\" data-start=\"556\"\u003eRemote On\/Off:\u003c\/strong\u003e Yes, via connector (no high-current switch needed)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"690\" data-start=\"628\"\u003e\n\u003cp data-end=\"690\" data-start=\"630\"\u003e\u003cstrong data-end=\"653\" data-start=\"630\"\u003eParallel Operation:\u003c\/strong\u003e Up to five units can be paralleled\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"734\" data-start=\"691\"\u003e\n\u003cp data-end=\"734\" data-start=\"693\"\u003e\u003cstrong data-end=\"705\" data-start=\"693\"\u003eCooling:\u003c\/strong\u003e Temperature-controlled fan\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"786\" data-start=\"735\"\u003e\n\u003cp data-end=\"786\" data-start=\"737\"\u003e\u003cstrong data-end=\"760\" data-start=\"737\"\u003eGalvanic Isolation:\u003c\/strong\u003e No (non-isolated model)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"869\" data-start=\"787\"\u003e\n\u003cp data-end=\"869\" data-start=\"789\"\u003e\u003cstrong data-end=\"805\" data-start=\"789\"\u003eProtections:\u003c\/strong\u003e Over-temperature, short-circuit, input under-voltage shutdown\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-end=\"904\" data-start=\"876\"\u003e\u003cstrong\u003ePhysical \u0026amp; Environmental\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-end=\"1092\" data-start=\"905\"\u003e\n\u003cli data-end=\"964\" data-start=\"905\"\u003e\n\u003cp data-end=\"964\" data-start=\"907\"\u003e\u003cstrong data-end=\"926\" data-start=\"907\"\u003eCooling Method:\u003c\/strong\u003e Fan-assisted, temperature-regulated\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1010\" data-start=\"965\"\u003e\n\u003cp data-end=\"1010\" data-start=\"967\"\u003e\u003cstrong data-end=\"987\" data-start=\"967\"\u003eConnection Type:\u003c\/strong\u003e Faston tabs (6.3 mm)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"1092\" data-start=\"1011\"\u003e\n\u003cp data-end=\"1092\" data-start=\"1013\"\u003e\u003cstrong data-end=\"1045\" data-start=\"1013\"\u003eOperating Temperature Range:\u003c\/strong\u003e –20 °C to +55 °C (with derating above 40 °C)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cmeta charset=\"utf-8\"\u003e\u003cstrong\u003eOnce purchased and in use, this product is non-returnable.\u003c\/strong\u003e\u003c\/p\u003e\n\u003c!--- cis2:m2lsnZdp ---\u003e\n\u003ch3\u003eProduct Manual\u003c\/h3\u003e\n\u003ch4\u003e\n\u003ca href=\"https:\/\/productimageserver.com\/literature\/quickGuide\/88340QG.pdf\" target=\"_blank\"\u003eQuick Guide (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/productimageserver.com\/literature\/brochure\/88340BR.pdf\" target=\"_blank\"\u003eBrochure (pdf)\u003c\/a\u003e\n\u003c\/h4\u003e\n\u003ch3\u003eProduct Warranty\u003c\/h3\u003e\n\u003ch2\u003e\u003cspan style=\"text-decoration: underline;\"\u003eVictron Energy Product Warranty\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cmeta charset=\"utf-8\"\u003eVictron Energy warrants its products to be free from defects in workmanship and materials for a period of 5 years from the date of purchase by the end-user, with a maximum of 66 months from the Victron Energy invoice date. Exceptions on this are: lead-acid batteries; 2 years from date of purchase by the end-user, with a maximum of 30 months from the Victron Energy invoice date, Lithium batteries; 3 years from date of purchase by the end-user. In addition to this, proof of correct battery usage is required when making a battery warranty claim.\u003c\/p\u003e\n\u003cp\u003eFor a 10% surcharge on the net price for products that came with a 5-year warranty, an additional 5 years of warranty can be purchased, bringing the total warranty to 10 years. Warranty extensions need to be applied for ultimately one year before expiration of the original term.\u003c\/p\u003e\n\u003cp\u003eDuring the warranty period, Victron Energy will, at its discretion, repair, replace or credit the defective product free of charge. The warranty does not include performing or reimbursing de‐installation, transportation, and re‐installation. This warranty will be considered void if the unit has suffered any physical damage or alteration, either internally or externally, and does not cover damages arising from improper use like:\u003c\/p\u003e\n\u003cp\u003e• Reverse of battery polarity.\u003c\/p\u003e\n\u003cp\u003e• Inadequate connection.\u003c\/p\u003e\n\u003cp\u003e• Mechanical shock or deformation.\u003c\/p\u003e\n\u003cp\u003e• Contact with liquid or oxidation by condensation.\u003c\/p\u003e\n\u003cp\u003e• Use in an inappropriate environment(dust, corrosive vapor, humidity, high temperature, biological infestation...). \u003c\/p\u003e\n\u003cp\u003e• Breakage or damage due to lightning.\u003c\/p\u003e\n\u003cp\u003e• Connection terminals and screws destroyed or other damages, like overheat, due to insufficient tightening.\u003c\/p\u003e\n\u003cp\u003e• For any electronic breakage except due to lightning (reverse polarity, over‐voltage due to external cause), the state of the internal control diode and\/or the input\/output X and Y capacitors determine the warranty.\u003c\/p\u003e\n\u003cp\u003eThis warranty will not apply where the product has been misused, neglected, improperly installed, or repaired by anyone else than Victron Energy or one of its authorized Repair Centres. In order to qualify for the warranty, the product must not be disassembled or modified.\u003c\/p\u003e\n\u003cp\u003eRepair, replacement or credit are our sole remedies and Victron Energy shall not be liable for damages, whether direct, incidental, special, or consequential, even caused by negligence or fault.\u003c\/p\u003e\n\u003cp\u003eVictron Energy owns all parts removed from repaired products. Victron Energy uses new or reconditioned parts made by various manufacturers when performing warranty repairs or building replacement products. If Victron Energy repairs or replaces a part of a product, its warranty term is not extended.\u003c\/p\u003e\n\u003cp\u003eAll remedies and the measure for damages are limited to the above.\u003c\/p\u003e\n\u003cp\u003eVictron Energy shall in no event be liable for consequential, incidental, contingent or special damages, even if having been advised of the probability of such damages. Any and all other warranties expressed or implied arising by law, course of dealing, course of performance, usage of trade or otherwise, including but not limited to implied warranties of merchantability and fitness for a particular purpose, are limited in duration to a period of five (5) years from the date of purchase, with the exception of batteries. For lead acid batteries a two (2) year period applies and for lithium batteries a three (3) year period applies.\u003c\/p\u003e\n\u003ch3\u003eProduct FAQs\u003c\/h3\u003e\n\u003cp\u003eN\/A\u003c\/p\u003e","brand":"Victron Energy","offers":[{"title":"Default Title","offer_id":50359634100507,"sku":"OGL-88340","price":118.15,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0724\/2026\/2171\/files\/88340XL.jpg?v=1749567959"},{"product_id":"victron-buck-boost-dc-dc-converter-50a-ori303050000","title":"Victron Energy Buck-Boost DC-DC Converter - 50A [ORI303050000]","description":"\u003ch2\u003e\u003cspan style=\"text-decoration: underline;\"\u003eVictron Energy Buck-Boost DC-DC Converter - 50A [ORI303050000]\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003eDC-DC Converter for charging a 12\/24V service battery in vehicles with an intelligent dynamo. \u003c\/p\u003e\n\u003cp\u003eThe Buck-Boost DC-DC Converter is a DC-DC converter for charging a 12\/24V service battery in vehicles with an intelligent dynamo. Since, when the engine is running, these dynamos (powered by the on-board electronics of Euro 5 and 6 engines) do not always emit the correct charging current, a DC-DC converter is essential for charging the service battery properly.\u003c\/p\u003e\n\u003cp\u003e\u003cmeta charset=\"utf-8\"\u003e\u003cstrong\u003eOnce purchased and in use, this product is non-returnable.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003eProduct Specifications\u003c\/h3\u003e\n\u003c!--- cis2:m2lsnZdp ---\u003e\n\u003ch2\u003e\n\u003cspan style=\"text-decoration: underline;\"\u003eVictron Energy Buck-Boost DC-DC Converter - 50A [ORI303050000] \u003cmeta charset=\"utf-8\"\u003e\u003c\/span\u003e\u003cspan style=\"text-decoration: underline;\"\u003eProduct Specifications\u003c\/span\u003e\n\u003c\/h2\u003e\n\u003cp data-start=\"154\" data-end=\"172\"\u003e\u003cstrong data-start=\"154\" data-end=\"172\"\u003ePower \u0026amp; Output\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"174\" data-end=\"499\"\u003e\n\u003cli data-start=\"174\" data-end=\"222\"\u003e\n\u003cp data-start=\"176\" data-end=\"222\"\u003eInput Voltage Range: 10 – 30 V DC (max 30 V)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"223\" data-end=\"277\"\u003e\n\u003cp data-start=\"225\" data-end=\"277\"\u003eOutput Voltage Range: 10 – 30 V DC (matches input)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"278\" data-end=\"357\"\u003e\n\u003cp data-start=\"280\" data-end=\"305\"\u003eMaximum Charge Current:\u003c\/p\u003e\n\u003cul data-start=\"308\" data-end=\"357\"\u003e\n\u003cli data-start=\"308\" data-end=\"331\"\u003e\n\u003cp data-start=\"310\" data-end=\"331\"\u003e50 A (12 V systems)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"334\" data-end=\"357\"\u003e\n\u003cp data-start=\"336\" data-end=\"357\"\u003e25 A (24 V systems)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"358\" data-end=\"436\"\u003e\n\u003cp data-start=\"360\" data-end=\"436\"\u003ePower Settings: Fully programmable output current and input current limits\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"437\" data-end=\"499\"\u003e\n\u003cp data-start=\"439\" data-end=\"499\"\u003eEfficiency\/Conversion: High-efficiency buck-boost topology\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"501\" data-end=\"527\"\u003e\u003cstrong data-start=\"501\" data-end=\"527\"\u003eFeatures \u0026amp; Protections\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"529\" data-end=\"905\"\u003e\n\u003cli data-start=\"529\" data-end=\"623\"\u003e\n\u003cp data-start=\"531\" data-end=\"623\"\u003eEngine‑Running Detection: Built-in sensor activates converter only when vehicle is running\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"624\" data-end=\"719\"\u003e\n\u003cp data-start=\"626\" data-end=\"719\"\u003eFully Programmable: Set charge voltage, current limits, activation conditions via USB cable\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"720\" data-end=\"801\"\u003e\n\u003cp data-start=\"722\" data-end=\"801\"\u003eLED Indicators: Input\/output status and engine detection via multi-color LEDs\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"802\" data-end=\"905\"\u003e\n\u003cp data-start=\"804\" data-end=\"905\"\u003eProtections: Over-temperature shutdown, smart alternator support, and input undervoltage protection\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"907\" data-end=\"935\"\u003e\u003cstrong data-start=\"907\" data-end=\"935\"\u003ePhysical \u0026amp; Environmental\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"937\" data-end=\"1046\"\u003e\n\u003cli data-start=\"937\" data-end=\"970\"\u003e\n\u003cp data-start=\"939\" data-end=\"970\"\u003eDimensions: 213 × 120 × 30 mm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"971\" data-end=\"989\"\u003e\n\u003cp data-start=\"973\" data-end=\"989\"\u003eWeight: 1.4 kg\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"990\" data-end=\"1046\"\u003e\n\u003cp data-start=\"992\" data-end=\"1046\"\u003eEnclosure: Compact design, wall or surface mountable\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1048\" data-end=\"1068\"\u003e\u003cstrong data-start=\"1048\" data-end=\"1068\"\u003eUse Case Summary\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1070\" data-end=\"1360\"\u003e\n\u003cli data-start=\"1070\" data-end=\"1216\"\u003e\n\u003cp data-start=\"1072\" data-end=\"1216\"\u003eDesigned for 12 V or 24 V service battery charging from 12\/24 V alternators—especially with smart alternators (Euro 5\/6, regenerative braking)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1217\" data-end=\"1282\"\u003e\n\u003cp data-start=\"1219\" data-end=\"1282\"\u003ePrevents overvoltage or undervoltage to the auxiliary battery\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1283\" data-end=\"1360\"\u003e\n\u003cp data-start=\"1285\" data-end=\"1360\"\u003eOffers adjustable current limiting to protect both alternator and battery\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eProduct Manual\u003c\/h3\u003e\n\u003ch4\u003e\n\u003ca href=\"https:\/\/productimageserver.com\/literature\/quickGuide\/88489QG.pdf\" target=\"_blank\"\u003eQuick Guide (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/productimageserver.com\/literature\/ownersManual\/88489OM.pdf\" target=\"_blank\"\u003eOwner's Manual (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/productimageserver.com\/literature\/brochure\/88489BR.pdf\" target=\"_blank\"\u003eBrochure (pdf)\u003c\/a\u003e\n\u003c\/h4\u003e\n\u003ch3\u003eProduct Warranty\u003c\/h3\u003e\n\u003ch2\u003e\u003cspan style=\"text-decoration: underline;\"\u003eVictron Energy Product Warranty\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cmeta charset=\"utf-8\"\u003eVictron Energy warrants its products to be free from defects in workmanship and materials for a period of 5 years from the date of purchase by the end-user, with a maximum of 66 months from the Victron Energy invoice date. Exceptions on this are: lead-acid batteries; 2 years from date of purchase by the end-user, with a maximum of 30 months from the Victron Energy invoice date, Lithium batteries; 3 years from date of purchase by the end-user. In addition to this, proof of correct battery usage is required when making a battery warranty claim.\u003c\/p\u003e\n\u003cp\u003eFor a 10% surcharge on the net price for products that came with a 5-year warranty, an additional 5 years of warranty can be purchased, bringing the total warranty to 10 years. Warranty extensions need to be applied for ultimately one year before expiration of the original term.\u003c\/p\u003e\n\u003cp\u003eDuring the warranty period, Victron Energy will, at its discretion, repair, replace or credit the defective product free of charge. The warranty does not include performing or reimbursing de‐installation, transportation, and re‐installation. This warranty will be considered void if the unit has suffered any physical damage or alteration, either internally or externally, and does not cover damages arising from improper use like:\u003c\/p\u003e\n\u003cp\u003e• Reverse of battery polarity.\u003c\/p\u003e\n\u003cp\u003e• Inadequate connection.\u003c\/p\u003e\n\u003cp\u003e• Mechanical shock or deformation.\u003c\/p\u003e\n\u003cp\u003e• Contact with liquid or oxidation by condensation.\u003c\/p\u003e\n\u003cp\u003e• Use in an inappropriate environment(dust, corrosive vapor, humidity, high temperature, biological infestation...). \u003c\/p\u003e\n\u003cp\u003e• Breakage or damage due to lightning.\u003c\/p\u003e\n\u003cp\u003e• Connection terminals and screws destroyed or other damages, like overheat, due to insufficient tightening.\u003c\/p\u003e\n\u003cp\u003e• For any electronic breakage except due to lightning (reverse polarity, over‐voltage due to external cause), the state of the internal control diode and\/or the input\/output X and Y capacitors determine the warranty.\u003c\/p\u003e\n\u003cp\u003eThis warranty will not apply where the product has been misused, neglected, improperly installed, or repaired by anyone else than Victron Energy or one of its authorized Repair Centres. In order to qualify for the warranty, the product must not be disassembled or modified.\u003c\/p\u003e\n\u003cp\u003eRepair, replacement or credit are our sole remedies and Victron Energy shall not be liable for damages, whether direct, incidental, special, or consequential, even caused by negligence or fault.\u003c\/p\u003e\n\u003cp\u003eVictron Energy owns all parts removed from repaired products. Victron Energy uses new or reconditioned parts made by various manufacturers when performing warranty repairs or building replacement products. If Victron Energy repairs or replaces a part of a product, its warranty term is not extended.\u003c\/p\u003e\n\u003cp\u003eAll remedies and the measure for damages are limited to the above.\u003c\/p\u003e\n\u003cp\u003eVictron Energy shall in no event be liable for consequential, incidental, contingent or special damages, even if having been advised of the probability of such damages. Any and all other warranties expressed or implied arising by law, course of dealing, course of performance, usage of trade or otherwise, including but not limited to implied warranties of merchantability and fitness for a particular purpose, are limited in duration to a period of five (5) years from the date of purchase, with the exception of batteries. For lead acid batteries a two (2) year period applies and for lithium batteries a three (3) year period applies.\u003c\/p\u003e\n\u003ch3\u003eProduct FAQs\u003c\/h3\u003e\n\u003cp\u003eN\/A\u003c\/p\u003e","brand":"Victron Energy","offers":[{"title":"Default Title","offer_id":50359634428187,"sku":"OGL-88489","price":851.7,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0724\/2026\/2171\/files\/88489XL.jpg?v=1749567961"},{"product_id":"victron-orion-ip67-dc-dc-converter-12-24-50a-1200w-ori122421226","title":"Victron Energy Orion IP67 DC-DC Converter 12\/24-50A - 1200W [ORI122421226]","description":"\u003ch2\u003e\u003cspan style=\"text-decoration: underline;\"\u003eVictron Energy Orion IP67 DC-DC Converter 12\/24-50A - 1200W [ORI122421226]\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003eCompletely encapsulated: waterproof, shockproof, and ignition-protected. Water, oil, or dirt will not damage the Orion IP67 DC-DC Converter. The casing is made of cast aluminum and the electronics are molded in resin.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompletely encapsulated: waterproof, shockproof, and ignition protected \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWater, oil, or dirt will not damage the Orion IP67 DC-DC Converter. The casing is made of cast aluminum and the electronics are molded in resin. \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eExtra-long input and output cables \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThanks to the cables of 1.8 meters in length, intermediate cable interconnections to increase length even more will in most cases not be needed. This is an important reliability-increasing feature in an area where an IP67 protection grade is needed. \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWide input voltage range \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWith a 15 to 40 Volts input range, a stable output is ensured during surges or sags due to other equipment connected to the same battery. \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProtected against overheating \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIt can be used in a hot environment such as a machine room.\u003c\/p\u003e\n\u003cp\u003e\u003cmeta charset=\"utf-8\"\u003e\u003cstrong\u003eOnce purchased and in use, this product is non-returnable.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003eProduct Specifications \u003c\/h3\u003e\n\u003c!--- cis2:m2lsnZdp ---\u003e\n\u003ch2\u003e\n\u003cspan style=\"text-decoration: underline;\"\u003eVictron Energy Orion IP67 DC-DC Converter 12\/24-50A - 1200W [ORI122421226] \u003cmeta charset=\"utf-8\"\u003e\u003c\/span\u003e\u003cspan style=\"text-decoration: underline;\"\u003eProduct Specifications\u003c\/span\u003e\n\u003c\/h2\u003e\n\u003cp data-end=\"158\" data-start=\"133\"\u003e\u003cstrong\u003ePower Specifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-end=\"379\" data-start=\"159\"\u003e\n\u003cli data-end=\"195\" data-start=\"159\"\u003e\n\u003cp data-end=\"195\" data-start=\"161\"\u003eInput Voltage Range: 10 – 17 VDC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"230\" data-start=\"196\"\u003e\n\u003cp data-end=\"230\" data-start=\"198\"\u003eOutput Voltage: 24.2 VDC fixed\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"255\" data-start=\"231\"\u003e\n\u003cp data-end=\"255\" data-start=\"233\"\u003eOutput Current: 50 A\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"280\" data-start=\"256\"\u003e\n\u003cp data-end=\"280\" data-start=\"258\"\u003eOutput Power: 1200 W\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"300\" data-start=\"281\"\u003e\n\u003cp data-end=\"300\" data-start=\"283\"\u003eEfficiency: 95%\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"339\" data-start=\"301\"\u003e\n\u003cp data-end=\"339\" data-start=\"303\"\u003eNo-load Power Consumption: \u0026lt; 80 mA\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"379\" data-start=\"340\"\u003e\n\u003cp data-end=\"379\" data-start=\"342\"\u003eGalvanic Isolation: No (non-isolated)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-end=\"412\" data-start=\"386\"\u003e\u003cstrong\u003eEnvironmental Ratings:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-end=\"574\" data-start=\"413\"\u003e\n\u003cli data-end=\"478\" data-start=\"413\"\u003e\n\u003cp data-end=\"478\" data-start=\"415\"\u003eOperating Temperature: -40 °C to +60 °C (derating from 40 °C)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"517\" data-start=\"479\"\u003e\n\u003cp data-end=\"517\" data-start=\"481\"\u003eHumidity: Max 95% (non-condensing)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"574\" data-start=\"518\"\u003e\n\u003cp data-end=\"574\" data-start=\"520\"\u003eIngress Protection: IP67 (fully waterproof, dustproof)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-end=\"609\" data-start=\"581\"\u003e\u003cstrong\u003ePhysical Specifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-end=\"736\" data-start=\"610\"\u003e\n\u003cli data-end=\"655\" data-start=\"610\"\u003e\n\u003cp data-end=\"655\" data-start=\"612\"\u003eDimensions (h x w x d): 178 x 126 x 65 mm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"674\" data-start=\"656\"\u003e\n\u003cp data-end=\"674\" data-start=\"658\"\u003eWeight: 1.8 kg\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"736\" data-start=\"675\"\u003e\n\u003cp data-end=\"736\" data-start=\"677\"\u003eEnclosure Material: Cast aluminum with epoxy powder coating\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-end=\"756\" data-start=\"743\"\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-end=\"926\" data-start=\"757\"\u003e\n\u003cli data-end=\"841\" data-start=\"757\"\u003e\n\u003cp data-end=\"841\" data-start=\"759\"\u003eRugged, sealed design suitable for marine, automotive, and off-grid environments\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"873\" data-start=\"842\"\u003e\n\u003cp data-end=\"873\" data-start=\"844\"\u003eOver-temperature protection\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"897\" data-start=\"874\"\u003e\n\u003cp data-end=\"897\" data-start=\"876\"\u003eShort circuit proof\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"926\" data-start=\"898\"\u003e\n\u003cp data-end=\"926\" data-start=\"900\"\u003eRemote on\/off capability\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eProduct Manual\u003c\/h3\u003e\n\u003ch4\u003e\u003ca href=\"https:\/\/productimageserver.com\/literature\/brochure\/89759BR.pdf\" target=\"_blank\"\u003eBrochure (pdf)\u003c\/a\u003e\u003c\/h4\u003e\n\u003ch3\u003eProduct Warranty\u003c\/h3\u003e\n\u003ch2\u003e\u003cspan style=\"text-decoration: underline;\"\u003eVictron Energy Product Warranty\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cmeta charset=\"utf-8\"\u003eVictron Energy warrants its products to be free from defects in workmanship and materials for a period of 5 years from the date of purchase by the end-user, with a maximum of 66 months from the Victron Energy invoice date. Exceptions on this are: lead-acid batteries; 2 years from date of purchase by the end-user, with a maximum of 30 months from the Victron Energy invoice date, Lithium batteries; 3 years from date of purchase by the end-user. In addition to this, proof of correct battery usage is required when making a battery warranty claim.\u003c\/p\u003e\n\u003cp\u003eFor a 10% surcharge on the net price for products that came with a 5-year warranty, an additional 5 years of warranty can be purchased, bringing the total warranty to 10 years. Warranty extensions need to be applied for ultimately one year before expiration of the original term.\u003c\/p\u003e\n\u003cp\u003eDuring the warranty period, Victron Energy will, at its discretion, repair, replace or credit the defective product free of charge. The warranty does not include performing or reimbursing de‐installation, transportation, and re‐installation. This warranty will be considered void if the unit has suffered any physical damage or alteration, either internally or externally, and does not cover damages arising from improper use like:\u003c\/p\u003e\n\u003cp\u003e• Reverse of battery polarity.\u003c\/p\u003e\n\u003cp\u003e• Inadequate connection.\u003c\/p\u003e\n\u003cp\u003e• Mechanical shock or deformation.\u003c\/p\u003e\n\u003cp\u003e• Contact with liquid or oxidation by condensation.\u003c\/p\u003e\n\u003cp\u003e• Use in an inappropriate environment(dust, corrosive vapor, humidity, high temperature, biological infestation...). \u003c\/p\u003e\n\u003cp\u003e• Breakage or damage due to lightning.\u003c\/p\u003e\n\u003cp\u003e• Connection terminals and screws destroyed or other damages, like overheat, due to insufficient tightening.\u003c\/p\u003e\n\u003cp\u003e• For any electronic breakage except due to lightning (reverse polarity, over‐voltage due to external cause), the state of the internal control diode and\/or the input\/output X and Y capacitors determine the warranty.\u003c\/p\u003e\n\u003cp\u003eThis warranty will not apply where the product has been misused, neglected, improperly installed, or repaired by anyone else than Victron Energy or one of its authorized Repair Centres. In order to qualify for the warranty, the product must not be disassembled or modified.\u003c\/p\u003e\n\u003cp\u003eRepair, replacement or credit are our sole remedies and Victron Energy shall not be liable for damages, whether direct, incidental, special, or consequential, even caused by negligence or fault.\u003c\/p\u003e\n\u003cp\u003eVictron Energy owns all parts removed from repaired products. Victron Energy uses new or reconditioned parts made by various manufacturers when performing warranty repairs or building replacement products. If Victron Energy repairs or replaces a part of a product, its warranty term is not extended.\u003c\/p\u003e\n\u003cp\u003eAll remedies and the measure for damages are limited to the above.\u003c\/p\u003e\n\u003cp\u003eVictron Energy shall in no event be liable for consequential, incidental, contingent or special damages, even if having been advised of the probability of such damages. Any and all other warranties expressed or implied arising by law, course of dealing, course of performance, usage of trade or otherwise, including but not limited to implied warranties of merchantability and fitness for a particular purpose, are limited in duration to a period of five (5) years from the date of purchase, with the exception of batteries. For lead acid batteries a two (2) year period applies and for lithium batteries a three (3) year period applies.\u003c\/p\u003e\n\u003ch3\u003eProduct FAQs\u003c\/h3\u003e\n\u003cp\u003eN\/A\u003c\/p\u003e","brand":"Victron Energy","offers":[{"title":"Default Title","offer_id":50359634952475,"sku":"OGL-89759","price":355.3,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0724\/2026\/2171\/files\/89759XL.jpg?v=1749567965"},{"product_id":"victron-orion-tr-dc-dc-converter-12-vdc-to-24-vdc-10a-isolated-ori122424110","title":"Victron Energy Orion-TR DC-DC Converter - 12 VDC TO 24 VDC - 10A Isolated [ORI122424110]","description":"\u003ch2\u003e\u003cspan style=\"text-decoration: underline;\"\u003eVictron Energy Orion-TR DC-DC Converter - 12 VDC TO 24 VDC - 10A Isolated [ORI122424110]\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eIsolated Model - separate in and out (-) leads \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRemote On\/Off Terminal\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe remote on\/off terminal eliminates the need for a high current switch in the input wiring. The remote on\/off can be operated with a low power switch or for example the engine run\/stop switch. \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAll Models Are Short Circuit Proof and Can Be Paralleled to Increase Output Current\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAn unlimited number of units can be connected in parallel.  \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHigh Temperature Protected \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe output current will reduce at high ambient temperatures.  \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIP43 Protection \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWhen installed with the screw terminals oriented downward.  \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eScrew Terminals \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo special tools are needed for installation.  \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInput Fuse (not replaceable) \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eOn 12 V and 24 V input models only.  \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAdjustable Output Voltage \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNot intended for battery charging (consider using an Orion-Tr Smart for battery charging).\u003c\/p\u003e\n\u003ch3\u003eProduct Specifications\u003c\/h3\u003e\n\u003ch2\u003e\n\u003cspan style=\"text-decoration: underline;\"\u003eVictron Energy Orion-TR DC-DC Converter - 12 VDC TO 24 VDC - 10A Isolated [ORI122424110] \u003cmeta charset=\"utf-8\"\u003e\u003c\/span\u003e\u003cspan style=\"text-decoration: underline;\"\u003eProduct Specifications\u003c\/span\u003e\n\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eInput Voltage Range: 8-17 V\u003c\/li\u003e\n\u003cli\u003eUnder Voltage Shut Down: 7 V\u003c\/li\u003e\n\u003cli\u003eUnder Voltage Restart: 7.5 V\u003c\/li\u003e\n\u003cli\u003eNominal Output Voltage: 12.2 V\u003c\/li\u003e\n\u003cli\u003eOutput Voltage Adjust Range: 10-15 V\u003c\/li\u003e\n\u003cli\u003eOutput Voltage Tolerance: +\/- 0,2 V\u003c\/li\u003e\n\u003cli\u003eOutput Noise: 2 mV rms\u003c\/li\u003e\n\u003cli\u003eCont. Output Current at Nominal Output Voltage and 40 Degrees C: 10 A\u003c\/li\u003e\n\u003cli\u003eMaximum Output Current (10 S) at Nominal Output Voltage: 15 A\u003c\/li\u003e\n\u003cli\u003eShort Circuit Output Current: 25 A\u003c\/li\u003e\n\u003cli\u003eCont. Output Power at 25 Degrees C: 280 W\u003c\/li\u003e\n\u003cli\u003eCont. Output Power at 40 Degrees C: 240 W\u003c\/li\u003e\n\u003cli\u003eEfficiency: 88 %\u003c\/li\u003e\n\u003cli\u003eNo Load Input Current (2): \u0026lt; 100 mA \u003c\/li\u003e\n\u003cli\u003eCurrent Consumption: \u0026lt; 200uA when disabled via its remote port\u003c\/li\u003e\n\u003cli\u003eGalvanic Isolation: 200 VDC between input, output, and case\u003c\/li\u003e\n\u003cli\u003eOperating Temperature Range: -20 to +55 Degrees C (derate 3 % per °C above 40 °C)\u003c\/li\u003e\n\u003cli\u003eHumidity: Max. 95 % non-condensing\u003c\/li\u003e\n\u003cli\u003eDC Connection: Screw terminals\u003c\/li\u003e\n\u003cli\u003eMaximum Cable Cross-Section: 16 mm² AWG6\u003c\/li\u003e\n\u003cli\u003eWeight: 1.3 kg (3 lb)\u003c\/li\u003e\n\u003cli\u003eDimensions (H x W x D): 130 x 186 x 70 mm (5.1 x 7.3 x 2.8 inch)\u003c\/li\u003e\n\u003cli\u003eSafety Standards: EN 60950\u003c\/li\u003e\n\u003cli\u003eEmission: EN 61000-6-3, EN 55014-1\u003c\/li\u003e\n\u003cli\u003eImmunity Standards: EN 61000-6-2, EN 61000-6-1, EN 55014-2\u003c\/li\u003e\n\u003cli\u003eAutomotive Directive Standards: ECE R10-5\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cmeta charset=\"utf-8\"\u003e\u003cstrong\u003eOnce purchased and in use, this product is non-returnable.\u003c\/strong\u003e\u003c\/p\u003e\n\u003c!--- cis2:m2lsnZdp ---\u003e\n\u003ch3\u003eProduct Manual\u003c\/h3\u003e\n\u003ch4\u003e\n\u003ca href=\"https:\/\/productimageserver.com\/literature\/quickGuide\/92885QG.pdf\" target=\"_blank\"\u003eQuick Guide (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/productimageserver.com\/literature\/ownersManual\/92885OM.pdf\" target=\"_blank\"\u003eOwner's Manual (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/productimageserver.com\/literature\/brochure\/92885BR.pdf\" target=\"_blank\"\u003eBrochure (pdf)\u003c\/a\u003e\n\u003c\/h4\u003e\n\u003ch3\u003eProduct Warranty\u003c\/h3\u003e\n\u003ch2\u003e\u003cspan style=\"text-decoration: underline;\"\u003eVictron Energy Product Warranty\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cmeta charset=\"utf-8\"\u003eVictron Energy warrants its products to be free from defects in workmanship and materials for a period of 5 years from the date of purchase by the end-user, with a maximum of 66 months from the Victron Energy invoice date. Exceptions on this are: lead-acid batteries; 2 years from date of purchase by the end-user, with a maximum of 30 months from the Victron Energy invoice date, Lithium batteries; 3 years from date of purchase by the end-user. In addition to this, proof of correct battery usage is required when making a battery warranty claim.\u003c\/p\u003e\n\u003cp\u003eFor a 10% surcharge on the net price for products that came with a 5-year warranty, an additional 5 years of warranty can be purchased, bringing the total warranty to 10 years. Warranty extensions need to be applied for ultimately one year before expiration of the original term.\u003c\/p\u003e\n\u003cp\u003eDuring the warranty period, Victron Energy will, at its discretion, repair, replace or credit the defective product free of charge. The warranty does not include performing or reimbursing de‐installation, transportation, and re‐installation. This warranty will be considered void if the unit has suffered any physical damage or alteration, either internally or externally, and does not cover damages arising from improper use like:\u003c\/p\u003e\n\u003cp\u003e• Reverse of battery polarity.\u003c\/p\u003e\n\u003cp\u003e• Inadequate connection.\u003c\/p\u003e\n\u003cp\u003e• Mechanical shock or deformation.\u003c\/p\u003e\n\u003cp\u003e• Contact with liquid or oxidation by condensation.\u003c\/p\u003e\n\u003cp\u003e• Use in an inappropriate environment(dust, corrosive vapor, humidity, high temperature, biological infestation...). \u003c\/p\u003e\n\u003cp\u003e• Breakage or damage due to lightning.\u003c\/p\u003e\n\u003cp\u003e• Connection terminals and screws destroyed or other damages, like overheat, due to insufficient tightening.\u003c\/p\u003e\n\u003cp\u003e• For any electronic breakage except due to lightning (reverse polarity, over‐voltage due to external cause), the state of the internal control diode and\/or the input\/output X and Y capacitors determine the warranty.\u003c\/p\u003e\n\u003cp\u003eThis warranty will not apply where the product has been misused, neglected, improperly installed, or repaired by anyone else than Victron Energy or one of its authorized Repair Centres. In order to qualify for the warranty, the product must not be disassembled or modified.\u003c\/p\u003e\n\u003cp\u003eRepair, replacement or credit are our sole remedies and Victron Energy shall not be liable for damages, whether direct, incidental, special, or consequential, even caused by negligence or fault.\u003c\/p\u003e\n\u003cp\u003eVictron Energy owns all parts removed from repaired products. Victron Energy uses new or reconditioned parts made by various manufacturers when performing warranty repairs or building replacement products. If Victron Energy repairs or replaces a part of a product, its warranty term is not extended.\u003c\/p\u003e\n\u003cp\u003eAll remedies and the measure for damages are limited to the above.\u003c\/p\u003e\n\u003cp\u003eVictron Energy shall in no event be liable for consequential, incidental, contingent or special damages, even if having been advised of the probability of such damages. Any and all other warranties expressed or implied arising by law, course of dealing, course of performance, usage of trade or otherwise, including but not limited to implied warranties of merchantability and fitness for a particular purpose, are limited in duration to a period of five (5) years from the date of purchase, with the exception of batteries. For lead acid batteries a two (2) year period applies and for lithium batteries a three (3) year period applies.\u003c\/p\u003e\n\u003ch3\u003eProduct FAQs\u003c\/h3\u003e\n\u003cp\u003eN\/A\u003c\/p\u003e","brand":"Victron Energy","offers":[{"title":"Default Title","offer_id":50359647535387,"sku":"OGL-92885","price":113.9,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0724\/2026\/2171\/files\/92885XL.jpg?v=1749568215"},{"product_id":"victron-orion-tr-isolated-dc-dc-converter-24-vdc-to-24-vdc-400w-17amp-ori242441110","title":"Victron Energy Orion-TR Isolated DC-DC Converter - 24 VDC to 24 VDC - 400W - 17AMP [ORI242441110]","description":"\u003ch2\u003e\u003cspan style=\"text-decoration: underline;\"\u003eVictron Energy Orion-TR Isolated DC-DC Converter - 24 VDC to 24 VDC - 400W - 17AMP [ORI242441110]\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eIsolated Model - separate in and out (-) leads \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRemote On\/Off Terminal\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe remote on\/off terminal eliminates the need for a high current switch in the input wiring. The remote on\/off can be operated with a low power switch or for example the engine run\/stop switch. \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAll Models Are Short Circuit Proof and Can Be Paralleled to Increase Output Current\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAn unlimited number of units can be connected in parallel.  \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHigh Temperature Protected \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe output current will reduce at high ambient temperatures.  \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIP43 Protection \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWhen installed with the screw terminals oriented downward.  \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eScrew Terminals \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo special tools are needed for installation.  \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInput Fuse (not replaceable) \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eOn 12 V and 24 V input models only.  \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAdjustable Output Voltage \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNot intended for battery charging (consider using an Orion-Tr Smart for battery charging).\u003c\/p\u003e\n\u003ch3\u003eProduct Specifications\u003c\/h3\u003e\n\u003ch2\u003e\n\u003cspan style=\"text-decoration: underline;\"\u003eVictron Energy Orion-TR Isolated DC-DC Converter - 24 VDC to 24 VDC - 400W - 17AMP [ORI242441110] \u003cmeta charset=\"utf-8\"\u003e\u003c\/span\u003e\u003cspan style=\"text-decoration: underline;\"\u003eProduct Specifications\u003c\/span\u003e\n\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eInput Voltage Range: 20-35 V\u003c\/li\u003e\n\u003cli\u003eUnder Voltage Shut Down: 14 V\u003c\/li\u003e\n\u003cli\u003eUnder Voltage Restart: 15 V\u003c\/li\u003e\n\u003cli\u003eNominal Output Voltage: 24.2 V\u003c\/li\u003e\n\u003cli\u003eOutput Voltage Adjust Range: 20-30 V\u003c\/li\u003e\n\u003cli\u003eOutput Voltage Tolerance: +\/- 0,2 V\u003c\/li\u003e\n\u003cli\u003eOutput Noise: 2 mV rms\u003c\/li\u003e\n\u003cli\u003eCont. Output Current at Nominal Output Voltage and 40 Degrees C: 17 A\u003c\/li\u003e\n\u003cli\u003eMaximum Output Current (10 S) at Nominal Output Voltage: 25 A\u003c\/li\u003e\n\u003cli\u003eShort Circuit Output Current: 40 A\u003c\/li\u003e\n\u003cli\u003eCont. Output Power at 25 Degrees C: 480 W\u003c\/li\u003e\n\u003cli\u003eCont. Output Power at 40 Degrees C: 400 W\u003c\/li\u003e\n\u003cli\u003eEfficiency: 89 %\u003c\/li\u003e\n\u003cli\u003eNo Load Input Current (2): \u0026lt; 80 mA \u003c\/li\u003e\n\u003cli\u003eGalvanic Isolation: 200 VDC between input, output, and case\u003c\/li\u003e\n\u003cli\u003eOperating Temperature Range: -20 to +55 Degrees C (derate 3 % per °C above 40 °C)\u003c\/li\u003e\n\u003cli\u003eHumidity: Max. 95 % non-condensing\u003c\/li\u003e\n\u003cli\u003eDC Connection: Screw terminals\u003c\/li\u003e\n\u003cli\u003eMaximum Cable Cross-Section: 16 mm² AWG6\u003c\/li\u003e\n\u003cli\u003eWeight: 1.6 kg (3.5 lb)\u003c\/li\u003e\n\u003cli\u003eDimensions (H x W x D): 130 x 186 x 70 mm (5.1 x 7.3 x 2.8 inch)\u003c\/li\u003e\n\u003cli\u003eSafety Standards: EN 60950\u003c\/li\u003e\n\u003cli\u003eEmission Standards: EN 61000-6-3, EN 55014-1\u003c\/li\u003e\n\u003cli\u003eImmunity Standards: EN 61000-6-2, EN 61000-6-1, EN 55014-2\u003c\/li\u003e\n\u003cli\u003eAutomotive Directive Standards: ECE R10-5\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!--- cis2:m2lsnZdp ---\u003e\n\u003cp\u003e\u003cb\u003eSpecifications:\u003c\/b\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eCharger Input - Voltage: 24v\u003c\/li\u003e\n\u003cli\u003eCharger Output - Amps: 17a\u003c\/li\u003e\n\u003cli\u003eCharger Output Voltage: 24v\u003c\/li\u003e\n\u003cli\u003eBox Dimensions: 3\"H x 5\"W x 9\"L WT: 2.9 lbs\u003c\/li\u003e\n\u003cli\u003eUPC: 8719076038856\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eProduct Manual\u003c\/h3\u003e\n\u003ch4\u003e\n\u003ca href=\"https:\/\/productimageserver.com\/literature\/quickGuide\/92890QG.pdf\" target=\"_blank\"\u003eQuick Guide (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/productimageserver.com\/literature\/ownersManual\/92890OM.pdf\" target=\"_blank\"\u003eOwner's Manual (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/productimageserver.com\/literature\/brochure\/92890BR.pdf\" target=\"_blank\"\u003eBrochure (pdf)\u003c\/a\u003e\n\u003c\/h4\u003e\n\u003ch3\u003eProduct Warranty\u003c\/h3\u003e\n\u003ch2\u003e\u003cspan style=\"text-decoration: underline;\"\u003eVictron Energy Product Warranty\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cmeta charset=\"utf-8\"\u003eVictron Energy warrants its products to be free from defects in workmanship and materials for a period of 5 years from the date of purchase by the end-user, with a maximum of 66 months from the Victron Energy invoice date. Exceptions on this are: lead-acid batteries; 2 years from date of purchase by the end-user, with a maximum of 30 months from the Victron Energy invoice date, Lithium batteries; 3 years from date of purchase by the end-user. In addition to this, proof of correct battery usage is required when making a battery warranty claim.\u003c\/p\u003e\n\u003cp\u003eFor a 10% surcharge on the net price for products that came with a 5-year warranty, an additional 5 years of warranty can be purchased, bringing the total warranty to 10 years. Warranty extensions need to be applied for ultimately one year before expiration of the original term.\u003c\/p\u003e\n\u003cp\u003eDuring the warranty period, Victron Energy will, at its discretion, repair, replace or credit the defective product free of charge. The warranty does not include performing or reimbursing de‐installation, transportation, and re‐installation. This warranty will be considered void if the unit has suffered any physical damage or alteration, either internally or externally, and does not cover damages arising from improper use like:\u003c\/p\u003e\n\u003cp\u003e• Reverse of battery polarity.\u003c\/p\u003e\n\u003cp\u003e• Inadequate connection.\u003c\/p\u003e\n\u003cp\u003e• Mechanical shock or deformation.\u003c\/p\u003e\n\u003cp\u003e• Contact with liquid or oxidation by condensation.\u003c\/p\u003e\n\u003cp\u003e• Use in an inappropriate environment(dust, corrosive vapor, humidity, high temperature, biological infestation...). \u003c\/p\u003e\n\u003cp\u003e• Breakage or damage due to lightning.\u003c\/p\u003e\n\u003cp\u003e• Connection terminals and screws destroyed or other damages, like overheat, due to insufficient tightening.\u003c\/p\u003e\n\u003cp\u003e• For any electronic breakage except due to lightning (reverse polarity, over‐voltage due to external cause), the state of the internal control diode and\/or the input\/output X and Y capacitors determine the warranty.\u003c\/p\u003e\n\u003cp\u003eThis warranty will not apply where the product has been misused, neglected, improperly installed, or repaired by anyone else than Victron Energy or one of its authorized Repair Centres. In order to qualify for the warranty, the product must not be disassembled or modified.\u003c\/p\u003e\n\u003cp\u003eRepair, replacement or credit are our sole remedies and Victron Energy shall not be liable for damages, whether direct, incidental, special, or consequential, even caused by negligence or fault.\u003c\/p\u003e\n\u003cp\u003eVictron Energy owns all parts removed from repaired products. Victron Energy uses new or reconditioned parts made by various manufacturers when performing warranty repairs or building replacement products. If Victron Energy repairs or replaces a part of a product, its warranty term is not extended.\u003c\/p\u003e\n\u003cp\u003eAll remedies and the measure for damages are limited to the above.\u003c\/p\u003e\n\u003cp\u003eVictron Energy shall in no event be liable for consequential, incidental, contingent or special damages, even if having been advised of the probability of such damages. Any and all other warranties expressed or implied arising by law, course of dealing, course of performance, usage of trade or otherwise, including but not limited to implied warranties of merchantability and fitness for a particular purpose, are limited in duration to a period of five (5) years from the date of purchase, with the exception of batteries. For lead acid batteries a two (2) year period applies and for lithium batteries a three (3) year period applies.\u003c\/p\u003e\n\u003ch3\u003eProduct FAQs\u003c\/h3\u003e\n\u003cp\u003eN\/A\u003c\/p\u003e","brand":"Victron Energy","offers":[{"title":"Default Title","offer_id":50359647568155,"sku":"OGL-92890","price":201.45,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0724\/2026\/2171\/files\/92890XL.jpg?v=1749568215"},{"product_id":"victron-orion-24-12-70a-dc-dc-converter-w-binding-posts-ip20-ori241270030","title":"Victron Energy Orion 24\/12-70A DC-DC Converter w\/Binding Posts - IP20 [ORI241270030]","description":"\u003ch2\u003e\u003cspan style=\"text-decoration: underline;\"\u003eVictron Energy Orion 24\/12-70A DC-DC Converter w\/Binding Posts - IP20 [ORI241270030]\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eRemote On-Off Connector\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe remote on-off eliminates the need for a high-current switch in the input wiring. The remote on-off can be.\u003c\/p\u003e\n\u003cp\u003eoperated with a low-power switch or by the engine run\/stop switch (see manual).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAll Models with Adjustable Output Can Also Be Used as a Battery Charger\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eFor example, charge a 12 Volt starter or accessory battery in an otherwise 24V system.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAll Models with Adjustable Output Can Be Paralleled to Increase Output Current\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eUp to five units can be connected in parallel.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eEasy to Install\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eDelivery includes four Insulated Fastons Female Crimp 6.3mm.\u003c\/p\u003e\n\u003ch3\u003eProduct Specifications\u003c\/h3\u003e\n\u003ch2\u003e\u003cspan style=\"text-decoration: underline;\"\u003eVictron Energy Orion 24\/12-70A DC-DC Converter w\/Binding Posts - IP20 [ORI241270030] Product Specifications\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eInput Voltage Range (V): 18-35\u003c\/li\u003e\n\u003cli\u003eUnder Voltage Shutdown (V): 14\u003c\/li\u003e\n\u003cli\u003eUnder Voltage Restart (V): 18\u003c\/li\u003e\n\u003cli\u003eOutput Voltage Adjustable with Potentiometer: Yes\u003c\/li\u003e\n\u003cli\u003eOutput Voltage (V): Adjustable, 10–15V, F set 13,2V\u003c\/li\u003e\n\u003cli\u003eEfficiency (%): 92\u003c\/li\u003e\n\u003cli\u003eSuitable to Buffer-Charge a Battery: Yes\u003c\/li\u003e\n\u003cli\u003eCan Be Connected in Parallel: Yes\u003c\/li\u003e\n\u003cli\u003eContinuous Output Current (A): 70\u003c\/li\u003e\n\u003cli\u003eMax. Output Current (A): 85\u003c\/li\u003e\n\u003cli\u003eFan-Assisted Cooling (Temp. Controlled): Yes\u003c\/li\u003e\n\u003cli\u003eGalvanic Isolation: No\u003c\/li\u003e\n\u003cli\u003eOff Load Current: \u0026lt; 20mA\u003c\/li\u003e\n\u003cli\u003eRemote On-off: Yes \u003c\/li\u003e\n\u003cli\u003eOperating Temperature Range (Derate 3% Per °C above 40°C): -20 to +55°C\u003c\/li\u003e\n\u003cli\u003eDC Connection: M6 bolts\u003c\/li\u003e\n\u003cli\u003eWeight: 0,9 kg \/ 2.0 lbs\u003c\/li\u003e\n\u003cli\u003eDimensions (H x W x D): (mm) 65 x 88 x 195 \/ (inch) 2.6” x 3.5” x 7.7”\u003c\/li\u003e\n\u003cli\u003e Safety Standards: EN 60950\u003c\/li\u003e\n\u003cli\u003e Emission Standards: EN 61000-6-3, EN 55014-1\u003c\/li\u003e\n\u003cli\u003e Immunity Standards: EN 61000-6-2, EN 61000-6-1, EN 55014-2\u003c\/li\u003e\n\u003cli\u003e Automotive Directive Standards: ECE R10-4\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eOnce purchased and in use, this product is non-returnable.\u003c\/strong\u003e\u003c\/p\u003e\n\u003c!--- cis2:m2lsnZdp ---\u003e\n\u003ch3\u003eProduct Manual\u003c\/h3\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/productimageserver.com\/literature\/quickGuide\/99868QG.pdf\" target=\"_blank\"\u003eQuick Guide (pdf)\u003c\/a\u003e\u003c\/p\u003e\n\u003ch3\u003eProduct Warranty\u003c\/h3\u003e\n\u003ch2\u003e\u003cspan style=\"text-decoration: underline;\"\u003eVictron Energy Product Warranty\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cmeta charset=\"utf-8\"\u003eVictron Energy warrants its products to be free from defects in workmanship and materials for a period of 5 years from the date of purchase by the end-user, with a maximum of 66 months from the Victron Energy invoice date. Exceptions on this are: lead-acid batteries; 2 years from date of purchase by the end-user, with a maximum of 30 months from the Victron Energy invoice date, Lithium batteries; 3 years from date of purchase by the end-user. In addition to this, proof of correct battery usage is required when making a battery warranty claim.\u003c\/p\u003e\n\u003cp\u003eFor a 10% surcharge on the net price for products that came with a 5-year warranty, an additional 5 years of warranty can be purchased, bringing the total warranty to 10 years. Warranty extensions need to be applied for ultimately one year before expiration of the original term.\u003c\/p\u003e\n\u003cp\u003eDuring the warranty period, Victron Energy will, at its discretion, repair, replace or credit the defective product free of charge. The warranty does not include performing or reimbursing de‐installation, transportation, and re‐installation. This warranty will be considered void if the unit has suffered any physical damage or alteration, either internally or externally, and does not cover damages arising from improper use like:\u003c\/p\u003e\n\u003cp\u003e• Reverse of battery polarity.\u003c\/p\u003e\n\u003cp\u003e• Inadequate connection.\u003c\/p\u003e\n\u003cp\u003e• Mechanical shock or deformation.\u003c\/p\u003e\n\u003cp\u003e• Contact with liquid or oxidation by condensation.\u003c\/p\u003e\n\u003cp\u003e• Use in an inappropriate environment(dust, corrosive vapor, humidity, high temperature, biological infestation...). \u003c\/p\u003e\n\u003cp\u003e• Breakage or damage due to lightning.\u003c\/p\u003e\n\u003cp\u003e• Connection terminals and screws destroyed or other damages, like overheat, due to insufficient tightening.\u003c\/p\u003e\n\u003cp\u003e• For any electronic breakage except due to lightning (reverse polarity, over‐voltage due to external cause), the state of the internal control diode and\/or the input\/output X and Y capacitors determine the warranty.\u003c\/p\u003e\n\u003cp\u003eThis warranty will not apply where the product has been misused, neglected, improperly installed, or repaired by anyone else than Victron Energy or one of its authorized Repair Centres. In order to qualify for the warranty, the product must not be disassembled or modified.\u003c\/p\u003e\n\u003cp\u003eRepair, replacement or credit are our sole remedies and Victron Energy shall not be liable for damages, whether direct, incidental, special, or consequential, even caused by negligence or fault.\u003c\/p\u003e\n\u003cp\u003eVictron Energy owns all parts removed from repaired products. Victron Energy uses new or reconditioned parts made by various manufacturers when performing warranty repairs or building replacement products. If Victron Energy repairs or replaces a part of a product, its warranty term is not extended.\u003c\/p\u003e\n\u003cp\u003eAll remedies and the measure for damages are limited to the above.\u003c\/p\u003e\n\u003cp\u003eVictron Energy shall in no event be liable for consequential, incidental, contingent or special damages, even if having been advised of the probability of such damages. Any and all other warranties expressed or implied arising by law, course of dealing, course of performance, usage of trade or otherwise, including but not limited to implied warranties of merchantability and fitness for a particular purpose, are limited in duration to a period of five (5) years from the date of purchase, with the exception of batteries. For lead acid batteries a two (2) year period applies and for lithium batteries a three (3) year period applies.\u003c\/p\u003e\n\u003ch3\u003eProduct FAQs\u003c\/h3\u003e\n\u003cp\u003eN\/A\u003c\/p\u003e","brand":"Victron Energy","offers":[{"title":"Default Title","offer_id":50359671030043,"sku":"OGL-99868","price":118.15,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0724\/2026\/2171\/files\/99868XL.jpg?v=1749568790"},{"product_id":"victron-orion-tr-12-48-8a-380w-isolated-dc-dc-converter-ori124838110","title":"Victron Energy Orion-TR 12\/48-8A (380W) Isolated DC-DC Converter [ORI124838110]","description":"\u003ch2\u003e\u003cspan style=\"text-decoration: underline;\"\u003eVictron Energy Orion-TR 12\/48-8A (380W) Isolated DC-DC Converter [ORI124838110]\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eRemote On\/Off Terminal\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe remote on\/off terminal eliminates the need for a high current switch in the input wiring. The remote on\/off can be operated with a low power switch or for example the engine run\/stop switch. \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAll Models Are Short Circuit Proof and Can Be Paralleled to Increase Output Current\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAn unlimited number of units can be connected in parallel.  \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHigh Temperature Protected \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe output current will reduce at high ambient temperatures.  \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIP43 Protection \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWhen installed with the screw terminals oriented downward.  \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eScrew Terminals \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo special tools are needed for installation.  \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInput Fuse (not replaceable) \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eOn 12 V and 24 V input models only.  \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAdjustable Output Voltage \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNot intended for battery charging (consider using an Orion-Tr Smart for battery charging).\u003c\/p\u003e\n\u003ch3\u003eProduct Specifications\u003c\/h3\u003e\n\u003ch2\u003e\u003cspan style=\"text-decoration: underline;\"\u003eVictron Energy Orion-TR 12\/48-8A (380W) Isolated DC-DC Converter [ORI124838110] Product Specifications\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eInput Voltage Range: 10-17 V\u003c\/li\u003e\n\u003cli\u003eUnder Voltage Shut Down: 7 V\u003c\/li\u003e\n\u003cli\u003eUnder Voltage Restart: 7.5 V\u003c\/li\u003e\n\u003cli\u003eNominal Output Voltage: 48.2 V\u003c\/li\u003e\n\u003cli\u003eOutput Voltage Adjust Range: 40-60 V\u003c\/li\u003e\n\u003cli\u003eOutput Voltage Tolerance: +\/- 0,2 V\u003c\/li\u003e\n\u003cli\u003eOutput Noise: 2 mV rms\u003c\/li\u003e\n\u003cli\u003eCont. Output Current at Nominal Output Voltage and 40 Degrees C: 8 A\u003c\/li\u003e\n\u003cli\u003eMaximum Output Current (10 S) at Nominal Output Voltage minus 20%: 15 A\u003c\/li\u003e\n\u003cli\u003eShort Circuit Output Current: 25 A\u003c\/li\u003e\n\u003cli\u003eCont. Output Power at 25 Degrees C: 430 W\u003c\/li\u003e\n\u003cli\u003eCont. Output Power at 40 Degrees C: 380 W\u003c\/li\u003e\n\u003cli\u003eEfficiency: 89 %\u003c\/li\u003e\n\u003cli\u003eNo Load Input Current (2): \u0026lt; 220 mA \u003c\/li\u003e\n\u003cli\u003eCurrent Consumption: \u0026lt; 200uA when disabled via its remote port\u003c\/li\u003e\n\u003cli\u003eGalvanic Isolation: 200 VDC between input, output, and case\u003c\/li\u003e\n\u003cli\u003eOperating Temperature Range: -20 to +55 Degrees C (derate 3 % per °C above 40 °C)\u003c\/li\u003e\n\u003cli\u003eHumidity: Max. 95 % non-condensing\u003c\/li\u003e\n\u003cli\u003eDC Connection: Screw terminals\u003c\/li\u003e\n\u003cli\u003eMaximum Cable Cross-Section: 16 mm² AWG6\u003c\/li\u003e\n\u003cli\u003eWeight: 1.8 kg (4 lb)\u003c\/li\u003e\n\u003cli\u003eDimensions (H x W x D): 130 x 186 x 80 mm (5.1 x 7.3 x 3.2 inch)\u003c\/li\u003e\n\u003cli\u003eSafety Standards: EN 60950\u003c\/li\u003e\n\u003cli\u003eImmunity Standards: EN 61000-6-2, EN 61000-6-1, EN 55014-2\u003c\/li\u003e\n\u003cli\u003eAutomotive Directive Standards: ECE R10-5\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cmeta charset=\"utf-8\"\u003e\u003cstrong\u003eOnce purchased and in use, this product is non-returnable.\u003c\/strong\u003e\u003c\/p\u003e\n\u003c!--- cis2:m2lsnZdp ---\u003e\n\u003cp\u003e\u003cb\u003eSpecifications:\u003c\/b\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eCharger Input - Voltage: 12v\u003c\/li\u003e\n\u003cli\u003eCharger Output - Amps: 8a\u003c\/li\u003e\n\u003cli\u003eCharger Output Voltage: 48v\u003c\/li\u003e\n\u003cli\u003eBox Dimensions: 4\"H x 6\"W x 9\"L WT: 3.5 lbs\u003c\/li\u003e\n\u003cli\u003eUPC: 8719076063650\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eProduct Manual\u003c\/h3\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/productimageserver.com\/literature\/quickGuide\/103414QG.pdf\" target=\"_blank\"\u003eQuick Guide (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/productimageserver.com\/literature\/ownersManual\/103414OM.pdf\" target=\"_blank\"\u003eOwner's Manual (pdf)\u003c\/a\u003e\u003c\/p\u003e\n\u003ch3\u003eProduct Warranty\u003c\/h3\u003e\n\u003ch2\u003e\u003cspan style=\"text-decoration: underline;\"\u003eVictron Energy Product Warranty\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cmeta charset=\"utf-8\"\u003eVictron Energy warrants its products to be free from defects in workmanship and materials for a period of 5 years from the date of purchase by the end-user, with a maximum of 66 months from the Victron Energy invoice date. Exceptions on this are: lead-acid batteries; 2 years from date of purchase by the end-user, with a maximum of 30 months from the Victron Energy invoice date, Lithium batteries; 3 years from date of purchase by the end-user. In addition to this, proof of correct battery usage is required when making a battery warranty claim.\u003c\/p\u003e\n\u003cp\u003eFor a 10% surcharge on the net price for products that came with a 5-year warranty, an additional 5 years of warranty can be purchased, bringing the total warranty to 10 years. Warranty extensions need to be applied for ultimately one year before expiration of the original term.\u003c\/p\u003e\n\u003cp\u003eDuring the warranty period, Victron Energy will, at its discretion, repair, replace or credit the defective product free of charge. The warranty does not include performing or reimbursing de‐installation, transportation, and re‐installation. This warranty will be considered void if the unit has suffered any physical damage or alteration, either internally or externally, and does not cover damages arising from improper use like:\u003c\/p\u003e\n\u003cp\u003e• Reverse of battery polarity.\u003c\/p\u003e\n\u003cp\u003e• Inadequate connection.\u003c\/p\u003e\n\u003cp\u003e• Mechanical shock or deformation.\u003c\/p\u003e\n\u003cp\u003e• Contact with liquid or oxidation by condensation.\u003c\/p\u003e\n\u003cp\u003e• Use in an inappropriate environment(dust, corrosive vapor, humidity, high temperature, biological infestation...). \u003c\/p\u003e\n\u003cp\u003e• Breakage or damage due to lightning.\u003c\/p\u003e\n\u003cp\u003e• Connection terminals and screws destroyed or other damages, like overheat, due to insufficient tightening.\u003c\/p\u003e\n\u003cp\u003e• For any electronic breakage except due to lightning (reverse polarity, over‐voltage due to external cause), the state of the internal control diode and\/or the input\/output X and Y capacitors determine the warranty.\u003c\/p\u003e\n\u003cp\u003eThis warranty will not apply where the product has been misused, neglected, improperly installed, or repaired by anyone else than Victron Energy or one of its authorized Repair Centres. In order to qualify for the warranty, the product must not be disassembled or modified.\u003c\/p\u003e\n\u003cp\u003eRepair, replacement or credit are our sole remedies and Victron Energy shall not be liable for damages, whether direct, incidental, special, or consequential, even caused by negligence or fault.\u003c\/p\u003e\n\u003cp\u003eVictron Energy owns all parts removed from repaired products. Victron Energy uses new or reconditioned parts made by various manufacturers when performing warranty repairs or building replacement products. If Victron Energy repairs or replaces a part of a product, its warranty term is not extended.\u003c\/p\u003e\n\u003cp\u003eAll remedies and the measure for damages are limited to the above.\u003c\/p\u003e\n\u003cp\u003eVictron Energy shall in no event be liable for consequential, incidental, contingent or special damages, even if having been advised of the probability of such damages. Any and all other warranties expressed or implied arising by law, course of dealing, course of performance, usage of trade or otherwise, including but not limited to implied warranties of merchantability and fitness for a particular purpose, are limited in duration to a period of five (5) years from the date of purchase, with the exception of batteries. For lead acid batteries a two (2) year period applies and for lithium batteries a three (3) year period applies.\u003c\/p\u003e\n\u003ch3\u003eProduct FAQs\u003c\/h3\u003e\n\u003cp\u003eN\/A\u003c\/p\u003e","brand":"Victron Energy","offers":[{"title":"Default Title","offer_id":50359686791451,"sku":"OGL-103414","price":201.45,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0724\/2026\/2171\/files\/103414XL.jpg?v=1749569289"},{"product_id":"victron-100a-buck-boost-dc-dc-converter-ori303100000","title":"Victron Energy 100A Buck-Boost DC-DC Converter [ORI303100000]","description":"\u003ch2\u003e\u003cspan style=\"text-decoration: underline;\"\u003eVictron Energy 100A Buck-Boost DC-DC Converter [ORI303100000]\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp id=\"isPasted\"\u003eDC-DC Converter for charging a 12\/24V service battery in vehicles with an intelligent dynamo. \u003c\/p\u003e\n\u003cp\u003eThe Buck-Boost DC-DC Converter is a DC-DC converter that charges a 12\/24V service battery in vehicles with an intelligent dynamo. Since these dynamos (powered by the onboard electronics of Euro 5 and 6 engines) do not always emit the correct charging current when the engine is running, a DC-DC converter is essential for charging the service battery properly.\u003c\/p\u003e\n\u003cp\u003e\u003cmeta charset=\"utf-8\"\u003e\u003cstrong\u003eOnce purchased and in use, this product is non-returnable.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003eProduct Specifications\u003c\/h3\u003e\n\u003cp\u003eN\/A\u003c\/p\u003e\n\u003c!--- cis2:m2lsnZdp ---\u003e\n\u003ch3\u003eProduct Manual\u003c\/h3\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/productimageserver.com\/literature\/quickGuide\/105881QG.pdf\" target=\"_blank\"\u003eQuick Guide (pdf)\u003c\/a\u003e\u003c\/p\u003e\n\u003ch3\u003eProduct Warranty\u003c\/h3\u003e\n\u003ch2\u003e\u003cspan style=\"text-decoration: underline;\"\u003eVictron Energy Product Warranty\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cmeta charset=\"utf-8\"\u003eVictron Energy warrants its products to be free from defects in workmanship and materials for a period of 5 years from the date of purchase by the end-user, with a maximum of 66 months from the Victron Energy invoice date. Exceptions on this are: lead-acid batteries; 2 years from date of purchase by the end-user, with a maximum of 30 months from the Victron Energy invoice date, Lithium batteries; 3 years from date of purchase by the end-user. In addition to this, proof of correct battery usage is required when making a battery warranty claim.\u003c\/p\u003e\n\u003cp\u003eFor a 10% surcharge on the net price for products that came with a 5-year warranty, an additional 5 years of warranty can be purchased, bringing the total warranty to 10 years. Warranty extensions need to be applied for ultimately one year before expiration of the original term.\u003c\/p\u003e\n\u003cp\u003eDuring the warranty period, Victron Energy will, at its discretion, repair, replace or credit the defective product free of charge. The warranty does not include performing or reimbursing de‐installation, transportation, and re‐installation. This warranty will be considered void if the unit has suffered any physical damage or alteration, either internally or externally, and does not cover damages arising from improper use like:\u003c\/p\u003e\n\u003cp\u003e• Reverse of battery polarity.\u003c\/p\u003e\n\u003cp\u003e• Inadequate connection.\u003c\/p\u003e\n\u003cp\u003e• Mechanical shock or deformation.\u003c\/p\u003e\n\u003cp\u003e• Contact with liquid or oxidation by condensation.\u003c\/p\u003e\n\u003cp\u003e• Use in an inappropriate environment(dust, corrosive vapor, humidity, high temperature, biological infestation...). \u003c\/p\u003e\n\u003cp\u003e• Breakage or damage due to lightning.\u003c\/p\u003e\n\u003cp\u003e• Connection terminals and screws destroyed or other damages, like overheat, due to insufficient tightening.\u003c\/p\u003e\n\u003cp\u003e• For any electronic breakage except due to lightning (reverse polarity, over‐voltage due to external cause), the state of the internal control diode and\/or the input\/output X and Y capacitors determine the warranty.\u003c\/p\u003e\n\u003cp\u003eThis warranty will not apply where the product has been misused, neglected, improperly installed, or repaired by anyone else than Victron Energy or one of its authorized Repair Centres. In order to qualify for the warranty, the product must not be disassembled or modified.\u003c\/p\u003e\n\u003cp\u003eRepair, replacement or credit are our sole remedies and Victron Energy shall not be liable for damages, whether direct, incidental, special, or consequential, even caused by negligence or fault.\u003c\/p\u003e\n\u003cp\u003eVictron Energy owns all parts removed from repaired products. Victron Energy uses new or reconditioned parts made by various manufacturers when performing warranty repairs or building replacement products. If Victron Energy repairs or replaces a part of a product, its warranty term is not extended.\u003c\/p\u003e\n\u003cp\u003eAll remedies and the measure for damages are limited to the above.\u003c\/p\u003e\n\u003cp\u003eVictron Energy shall in no event be liable for consequential, incidental, contingent or special damages, even if having been advised of the probability of such damages. Any and all other warranties expressed or implied arising by law, course of dealing, course of performance, usage of trade or otherwise, including but not limited to implied warranties of merchantability and fitness for a particular purpose, are limited in duration to a period of five (5) years from the date of purchase, with the exception of batteries. For lead acid batteries a two (2) year period applies and for lithium batteries a three (3) year period applies.\u003c\/p\u003e\n\u003ch3\u003eProduct FAQs\u003c\/h3\u003e\n\u003cp\u003eN\/A\u003c\/p\u003e","brand":"Victron Energy","offers":[{"title":"Default Title","offer_id":50359691804955,"sku":"OGL-105881","price":1490.05,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0724\/2026\/2171\/files\/105881XL.jpg?v=1749569554"},{"product_id":"victron-orion-tr-smart-12-24-5a-120w-isolated-dc-dc-converter-ori122410110","title":"Victron Energy Orion-Tr Smart 12\/24-5A 120W Isolated DC-DC Converter [ORI122410110]","description":"\u003ch2\u003e\u003cspan style=\"text-decoration: underline;\"\u003eVictron Energy Orion-Tr Smart 12\/24-5A 120W Isolated DC-DC Converter [ORI122410110]\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp id=\"isPasted\"\u003eThe Orion-Tr Smart DC-DC charger is a professional DC to DC adaptive 3-stage charger with built-in Bluetooth.\u003c\/p\u003e\n\u003cp\u003eFor use in dual battery systems in vehicles or on boats where the (smart) alternator and the start battery are used to charge the service battery. The unit can be monitored and programmed via Bluetooth and can be remotely controlled via a remote on\/off switch and has an engine running detection mechanism.\u003c\/p\u003e\n\u003cp\u003eThe Orion-Tr Smart charger can be used in 12V or 24V systems and is suitable for both lead acid and lithium batteries. Models are available up to 400W and unlimited multiple units can be connected in parallel to increase output power.\u003c\/p\u003e\n\u003cp\u003eSuitable for high temperatures up to 55°C with a full rated output up to 40°C.\u003c\/p\u003e\n\u003cp\u003e\u003cmeta charset=\"utf-8\"\u003e\u003cstrong\u003eOnce purchased and in use, this product is non-returnable.\u003c\/strong\u003e\u003c\/p\u003e\n\u003c!--- cis2:m2lsnZdp ---\u003e\n\u003ch3\u003eProduct Specifications\u003c\/h3\u003e\n\u003cp\u003eN\/A\u003c\/p\u003e\n\u003ch3\u003eProduct Manual\u003c\/h3\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/productimageserver.com\/literature\/quickGuide\/107038QG.pdf\" target=\"_blank\"\u003eQuick Guide (pdf)\u003c\/a\u003e\u003c\/p\u003e\n\u003ch3\u003eProduct Warranty\u003c\/h3\u003e\n\u003ch2\u003e\u003cspan style=\"text-decoration: underline;\"\u003eVictron Energy Product Warranty\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cmeta charset=\"utf-8\"\u003eVictron Energy warrants its products to be free from defects in workmanship and materials for a period of 5 years from the date of purchase by the end-user, with a maximum of 66 months from the Victron Energy invoice date. Exceptions on this are: lead-acid batteries; 2 years from date of purchase by the end-user, with a maximum of 30 months from the Victron Energy invoice date, Lithium batteries; 3 years from date of purchase by the end-user. In addition to this, proof of correct battery usage is required when making a battery warranty claim.\u003c\/p\u003e\n\u003cp\u003eFor a 10% surcharge on the net price for products that came with a 5-year warranty, an additional 5 years of warranty can be purchased, bringing the total warranty to 10 years. Warranty extensions need to be applied for ultimately one year before expiration of the original term.\u003c\/p\u003e\n\u003cp\u003eDuring the warranty period, Victron Energy will, at its discretion, repair, replace or credit the defective product free of charge. The warranty does not include performing or reimbursing de‐installation, transportation, and re‐installation. This warranty will be considered void if the unit has suffered any physical damage or alteration, either internally or externally, and does not cover damages arising from improper use like:\u003c\/p\u003e\n\u003cp\u003e• Reverse of battery polarity.\u003c\/p\u003e\n\u003cp\u003e• Inadequate connection.\u003c\/p\u003e\n\u003cp\u003e• Mechanical shock or deformation.\u003c\/p\u003e\n\u003cp\u003e• Contact with liquid or oxidation by condensation.\u003c\/p\u003e\n\u003cp\u003e• Use in an inappropriate environment(dust, corrosive vapor, humidity, high temperature, biological infestation...). \u003c\/p\u003e\n\u003cp\u003e• Breakage or damage due to lightning.\u003c\/p\u003e\n\u003cp\u003e• Connection terminals and screws destroyed or other damages, like overheat, due to insufficient tightening.\u003c\/p\u003e\n\u003cp\u003e• For any electronic breakage except due to lightning (reverse polarity, over‐voltage due to external cause), the state of the internal control diode and\/or the input\/output X and Y capacitors determine the warranty.\u003c\/p\u003e\n\u003cp\u003eThis warranty will not apply where the product has been misused, neglected, improperly installed, or repaired by anyone else than Victron Energy or one of its authorized Repair Centres. In order to qualify for the warranty, the product must not be disassembled or modified.\u003c\/p\u003e\n\u003cp\u003eRepair, replacement or credit are our sole remedies and Victron Energy shall not be liable for damages, whether direct, incidental, special, or consequential, even caused by negligence or fault.\u003c\/p\u003e\n\u003cp\u003eVictron Energy owns all parts removed from repaired products. Victron Energy uses new or reconditioned parts made by various manufacturers when performing warranty repairs or building replacement products. If Victron Energy repairs or replaces a part of a product, its warranty term is not extended.\u003c\/p\u003e\n\u003cp\u003eAll remedies and the measure for damages are limited to the above.\u003c\/p\u003e\n\u003cp\u003eVictron Energy shall in no event be liable for consequential, incidental, contingent or special damages, even if having been advised of the probability of such damages. Any and all other warranties expressed or implied arising by law, course of dealing, course of performance, usage of trade or otherwise, including but not limited to implied warranties of merchantability and fitness for a particular purpose, are limited in duration to a period of five (5) years from the date of purchase, with the exception of batteries. For lead acid batteries a two (2) year period applies and for lithium batteries a three (3) year period applies.\u003c\/p\u003e\n\u003ch3\u003eProduct FAQs\u003c\/h3\u003e\n\u003cp\u003eN\/A\u003c\/p\u003e","brand":"Victron Energy","offers":[{"title":"Default Title","offer_id":50359693869339,"sku":"OGL-107038","price":63.75,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0724\/2026\/2171\/files\/107038XL.jpg?v=1749569566"},{"product_id":"victron-orion-tr-smart-24-48-8-5a-400w-isolated-dc-dc-charger-ori244840120","title":"Victron Energy Orion-TR Smart 24\/48 8.5A (400W) Isolated DC-DC Charger [ORI244840120]","description":"\u003ch2\u003e\u003cspan style=\"text-decoration: underline;\"\u003eVictron Energy Orion-TR Smart 24\/48 8.5A (400W) Isolated DC-DC Charger [ORI244840120]\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003eThe Orion-Tr Smart DC-DC charger is a professional DC to DC adaptive 3-stage charger with built-in Bluetooth.\u003c\/p\u003e\n\u003cp\u003eThis is for use in dual battery systems in vehicles or on boats, the alternator and the start battery are used to charge the service battery. The unit can be monitored and programmed via Bluetooth and can be remotely controlled via a remote on\/off switch.\u003c\/p\u003e\n\u003cp\u003eThe Orion Tr-Smart charger can be used in 12V or 24V systems and is suitable for both lead acid and lithium batteries. Models are available up to 400W and unlimited multiple units can be connected in parallel to increase output power.\u003c\/p\u003e\n\u003cp\u003eSuitable for high temperatures up to 55°C with a full rated output up to 40°C.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eVictronConnect\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eVictronConnect lets you get live status information and configure any Victron products which either have Bluetooth built-in, or are connected to a VE.Direct Bluetooth Smart Dongle.\u003c\/p\u003e\n\u003cp\u003e\u003cmeta charset=\"utf-8\"\u003e\u003cstrong\u003eOnce purchased and in use, this product is non-returnable.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003eProduct Specifications\u003c\/h3\u003e\n\u003cp\u003eN\/A\u003c\/p\u003e\n\u003c!--- cis2:m2lsnZdp ---\u003e\n\u003ch3\u003eProduct Manual\u003c\/h3\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/productimageserver.com\/literature\/quickGuide\/107887QG.pdf\" target=\"_blank\"\u003eQuick Guide (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/productimageserver.com\/literature\/ownersManual\/107887OM.pdf\" target=\"_blank\"\u003eOwner's Manual (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/productimageserver.com\/literature\/brochure\/107887BR.pdf\" target=\"_blank\"\u003eBrochure (pdf)\u003c\/a\u003e\u003c\/p\u003e\n\u003ch3\u003eProduct Warranty\u003c\/h3\u003e\n\u003ch2\u003e\u003cspan style=\"text-decoration: underline;\"\u003eVictron Energy Product Warranty\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cmeta charset=\"utf-8\"\u003eVictron Energy warrants its products to be free from defects in workmanship and materials for a period of 5 years from the date of purchase by the end-user, with a maximum of 66 months from the Victron Energy invoice date. Exceptions on this are: lead-acid batteries; 2 years from date of purchase by the end-user, with a maximum of 30 months from the Victron Energy invoice date, Lithium batteries; 3 years from date of purchase by the end-user. In addition to this, proof of correct battery usage is required when making a battery warranty claim.\u003c\/p\u003e\n\u003cp\u003eFor a 10% surcharge on the net price for products that came with a 5-year warranty, an additional 5 years of warranty can be purchased, bringing the total warranty to 10 years. Warranty extensions need to be applied for ultimately one year before expiration of the original term.\u003c\/p\u003e\n\u003cp\u003eDuring the warranty period, Victron Energy will, at its discretion, repair, replace or credit the defective product free of charge. The warranty does not include performing or reimbursing de‐installation, transportation, and re‐installation. This warranty will be considered void if the unit has suffered any physical damage or alteration, either internally or externally, and does not cover damages arising from improper use like:\u003c\/p\u003e\n\u003cp\u003e• Reverse of battery polarity.\u003c\/p\u003e\n\u003cp\u003e• Inadequate connection.\u003c\/p\u003e\n\u003cp\u003e• Mechanical shock or deformation.\u003c\/p\u003e\n\u003cp\u003e• Contact with liquid or oxidation by condensation.\u003c\/p\u003e\n\u003cp\u003e• Use in an inappropriate environment(dust, corrosive vapor, humidity, high temperature, biological infestation...). \u003c\/p\u003e\n\u003cp\u003e• Breakage or damage due to lightning.\u003c\/p\u003e\n\u003cp\u003e• Connection terminals and screws destroyed or other damages, like overheat, due to insufficient tightening.\u003c\/p\u003e\n\u003cp\u003e• For any electronic breakage except due to lightning (reverse polarity, over‐voltage due to external cause), the state of the internal control diode and\/or the input\/output X and Y capacitors determine the warranty.\u003c\/p\u003e\n\u003cp\u003eThis warranty will not apply where the product has been misused, neglected, improperly installed, or repaired by anyone else than Victron Energy or one of its authorized Repair Centres. In order to qualify for the warranty, the product must not be disassembled or modified.\u003c\/p\u003e\n\u003cp\u003eRepair, replacement or credit are our sole remedies and Victron Energy shall not be liable for damages, whether direct, incidental, special, or consequential, even caused by negligence or fault.\u003c\/p\u003e\n\u003cp\u003eVictron Energy owns all parts removed from repaired products. Victron Energy uses new or reconditioned parts made by various manufacturers when performing warranty repairs or building replacement products. If Victron Energy repairs or replaces a part of a product, its warranty term is not extended.\u003c\/p\u003e\n\u003cp\u003eAll remedies and the measure for damages are limited to the above.\u003c\/p\u003e\n\u003cp\u003eVictron Energy shall in no event be liable for consequential, incidental, contingent or special damages, even if having been advised of the probability of such damages. Any and all other warranties expressed or implied arising by law, course of dealing, course of performance, usage of trade or otherwise, including but not limited to implied warranties of merchantability and fitness for a particular purpose, are limited in duration to a period of five (5) years from the date of purchase, with the exception of batteries. For lead acid batteries a two (2) year period applies and for lithium batteries a three (3) year period applies.\u003c\/p\u003e\n\u003ch3\u003eProduct FAQs\u003c\/h3\u003e\n\u003cp\u003eN\/A\u003c\/p\u003e","brand":"Victron Energy","offers":[{"title":"Default Title","offer_id":50359695638811,"sku":"OGL-107887","price":243.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0724\/2026\/2171\/files\/107887XL.jpg?v=1749569578"},{"product_id":"victron-orion-tr-smart-dc-dc-charger-isolated-48-12-20a-240w-ori481224110","title":"Victron Energy Orion-Tr Smart DC-DC Charger Isolated 48\/12 20A (240W) [ORI481224110]","description":"\u003ch2\u003e\u003cspan style=\"text-decoration: underline;\"\u003eVictron Energy Orion-Tr Smart DC-DC Charger Isolated 48\/12 20A (240W) [ORI481224110]\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp id=\"isPasted\"\u003eThe Orion-Tr Smart DC-DC charger is a professional DC to DC adaptive 3-stage charger with built-in Bluetooth.\u003c\/p\u003e\n\u003cp\u003eFor use in dual battery systems in vehicles or on boats where the (smart) alternator and the start battery are used to charge the service battery. The unit can be monitored and programmed via Bluetooth and can be remotely controlled via a remote on\/off switch and has an engine running detection mechanism.\u003c\/p\u003e\n\u003cp\u003eThe Orion-Tr Smart charger can be used in 12V, 24V, or 48V systems and is suitable for both lead acid and lithium batteries. Models are available up to 400W and unlimited multiple units can be connected in parallel to increase output power.\u003c\/p\u003e\n\u003cp\u003eSuitable for high temperatures up to 55°C with a full rated output up to 40°C.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli id=\"isPasted\"\u003eRemote on\/off terminal - The remote on\/off terminal eliminates the need for a high current switch in the input wiring. The remote on\/off can be operated with a low power switch or for example the engine run\/stop switch.\u003c\/li\u003e\n\u003cli\u003eAll models are short circuit proof and can be paralleled to increase output current - An unlimited number of units can be connected in parallel.\u003c\/li\u003e\n\u003cli\u003eHigh temperature protected - The output current will reduce at high ambient temperature.\u003c\/li\u003e\n\u003cli\u003eIP43 protection - When installed with the screw terminals oriented downwards.\u003c\/li\u003e\n\u003cli\u003eScrew terminals - No special tools are needed for installation.\u003c\/li\u003e\n\u003cli\u003eInput fuse (not replaceable) - On 12 V and 24 V input models only.\u003c\/li\u003e\n\u003cli\u003eAdjustable output voltage - Not intended for battery charging. Please consider using an Orion-Tr Smart for battery charging.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!--- cis2:m2lsnZdp ---\u003e\n\u003cp\u003e\u003cmeta charset=\"utf-8\"\u003e\u003cstrong\u003eOnce purchased and in use, this product is non-returnable.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003eProduct Specifications\u003c\/h3\u003e\n\u003cp\u003eN\/A\u003c\/p\u003e\n\u003ch3\u003eProduct Manual\u003c\/h3\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/productimageserver.com\/literature\/quickGuide\/108138QG.pdf\" target=\"_blank\"\u003eQuick Guide (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/productimageserver.com\/literature\/ownersManual\/108138OM.pdf\" target=\"_blank\"\u003eOwner's Manual (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/productimageserver.com\/literature\/brochure\/108138BR.pdf\" target=\"_blank\"\u003eBrochure (pdf)\u003c\/a\u003e\u003c\/p\u003e\n\u003ch3\u003eProduct Warranty\u003c\/h3\u003e\n\u003ch2\u003e\u003cspan style=\"text-decoration: underline;\"\u003eVictron Energy Product Warranty\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cmeta charset=\"utf-8\"\u003eVictron Energy warrants its products to be free from defects in workmanship and materials for a period of 5 years from the date of purchase by the end-user, with a maximum of 66 months from the Victron Energy invoice date. Exceptions on this are: lead-acid batteries; 2 years from date of purchase by the end-user, with a maximum of 30 months from the Victron Energy invoice date, Lithium batteries; 3 years from date of purchase by the end-user. In addition to this, proof of correct battery usage is required when making a battery warranty claim.\u003c\/p\u003e\n\u003cp\u003eFor a 10% surcharge on the net price for products that came with a 5-year warranty, an additional 5 years of warranty can be purchased, bringing the total warranty to 10 years. Warranty extensions need to be applied for ultimately one year before expiration of the original term.\u003c\/p\u003e\n\u003cp\u003eDuring the warranty period, Victron Energy will, at its discretion, repair, replace or credit the defective product free of charge. The warranty does not include performing or reimbursing de‐installation, transportation, and re‐installation. This warranty will be considered void if the unit has suffered any physical damage or alteration, either internally or externally, and does not cover damages arising from improper use like:\u003c\/p\u003e\n\u003cp\u003e• Reverse of battery polarity.\u003c\/p\u003e\n\u003cp\u003e• Inadequate connection.\u003c\/p\u003e\n\u003cp\u003e• Mechanical shock or deformation.\u003c\/p\u003e\n\u003cp\u003e• Contact with liquid or oxidation by condensation.\u003c\/p\u003e\n\u003cp\u003e• Use in an inappropriate environment(dust, corrosive vapor, humidity, high temperature, biological infestation...). \u003c\/p\u003e\n\u003cp\u003e• Breakage or damage due to lightning.\u003c\/p\u003e\n\u003cp\u003e• Connection terminals and screws destroyed or other damages, like overheat, due to insufficient tightening.\u003c\/p\u003e\n\u003cp\u003e• For any electronic breakage except due to lightning (reverse polarity, over‐voltage due to external cause), the state of the internal control diode and\/or the input\/output X and Y capacitors determine the warranty.\u003c\/p\u003e\n\u003cp\u003eThis warranty will not apply where the product has been misused, neglected, improperly installed, or repaired by anyone else than Victron Energy or one of its authorized Repair Centres. In order to qualify for the warranty, the product must not be disassembled or modified.\u003c\/p\u003e\n\u003cp\u003eRepair, replacement or credit are our sole remedies and Victron Energy shall not be liable for damages, whether direct, incidental, special, or consequential, even caused by negligence or fault.\u003c\/p\u003e\n\u003cp\u003eVictron Energy owns all parts removed from repaired products. Victron Energy uses new or reconditioned parts made by various manufacturers when performing warranty repairs or building replacement products. If Victron Energy repairs or replaces a part of a product, its warranty term is not extended.\u003c\/p\u003e\n\u003cp\u003eAll remedies and the measure for damages are limited to the above.\u003c\/p\u003e\n\u003cp\u003eVictron Energy shall in no event be liable for consequential, incidental, contingent or special damages, even if having been advised of the probability of such damages. Any and all other warranties expressed or implied arising by law, course of dealing, course of performance, usage of trade or otherwise, including but not limited to implied warranties of merchantability and fitness for a particular purpose, are limited in duration to a period of five (5) years from the date of purchase, with the exception of batteries. For lead acid batteries a two (2) year period applies and for lithium batteries a three (3) year period applies.\u003c\/p\u003e\n\u003ch3\u003eProduct FAQs\u003c\/h3\u003e\n\u003cp\u003eN\/A\u003c\/p\u003e","brand":"Victron Energy","offers":[{"title":"Default Title","offer_id":50359705862427,"sku":"OGL-108138","price":113.9,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0724\/2026\/2171\/files\/108138XL.jpg?v=1749569633"},{"product_id":"mastervolt-dc-master-24v-to-12v-converter-12-amp-81400300","title":"Mastervolt DC Master 24V to 12V Converter - 12 Amp [81400300]","description":"\u003ch2\u003e\u003cspan style=\"text-decoration: underline;\"\u003eMastervolt DC Master 24V to 12V Converter - 12 Amp [81400300]\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003eAlways on course with Mastervolt. Mastervolt ensures you an electrical system with no weak links and a dependable and silent power supply. Whether for recreational or professional purposes, with Mastervolt you always have power you can rely on... The power to be independent.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDC Master DC-DC converters\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe required voltage for DC current can vary. Some equipment requires 24 V, while onboard equipment usually requires 12 V. For custom DC current, Mastervolt offers a series of compact and made to measure DC-DC converters for both 12 V and 24 V battery systems that offer stable power with the right current for any connected consumer.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eRecreational and semi-professional use\u003c\/li\u003e\n\u003cli\u003eEasy to install using included mounting bracket, screws and fasteners\u003c\/li\u003e\n\u003cli\u003eSmart electronics mean no unnecessary heat generation\u003c\/li\u003e\n\u003cli\u003eContinuous output\u003c\/li\u003e\n\u003cli\u003eTwo minutes of extra power for short power boosts\u003c\/li\u003e\n\u003cli\u003eExcellent price\/performance ratio\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eProduct Specifications\u003c\/h3\u003e\n\u003ch2\u003e\u003cspan style=\"text-decoration: underline;\"\u003eMastervolt DC Master 24V to 12V Converter - 12 Amp [81400300] \u003cmeta charset=\"utf-8\"\u003eProduct Specifications\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp id=\"isPasted\"\u003e\u003cstrong\u003eGeneral Specifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eNominal output voltage: 13.6 V\u003c\/li\u003e\n\u003cli\u003eMax. output power: 245 W\u003c\/li\u003e\n\u003cli\u003eNominal output power: 164 W\u003c\/li\u003e\n\u003cli\u003eMax. output current (for 2 min. intervals): 18 A\u003c\/li\u003e\n\u003cli\u003eContinuous output current: 12 A\u003c\/li\u003e\n\u003cli\u003eNominal input voltage: 24 V\u003c\/li\u003e\n\u003cli\u003eInput voltage range (max.): 20-32 V DC (35 V)\u003c\/li\u003e\n\u003cli\u003eGalvanic isolation: no\u003c\/li\u003e\n\u003cli\u003eStabilised: yes\u003c\/li\u003e\n\u003cli\u003eDimensions, hxwxd: 127 x 87 x 50 mm 5.0 x 3.4 x 2.0 inch\u003c\/li\u003e\n\u003cli\u003eWeight: 0.405 kg 0.9 lb\u003c\/li\u003e\n\u003cli\u003eCompliance: CE\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eDC consumption: \u0026lt; 15 mA\u003c\/li\u003e\n\u003cli\u003eConnections: fast-on\u003c\/li\u003e\n\u003cli\u003eTemperature range (ambient temp.): -25 °C to 80 °C, derating \u0026gt; 30\u003c\/li\u003e\n\u003cli\u003eCooling: natural cooling\u003c\/li\u003e\n\u003cli\u003eProtection degree: IP53\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cimg alt=\"Warning\" src=\"https:\/\/productimageserver.com\/prop65\/6pt.png\"\u003e\u003cstrong\u003eWARNING:\u003c\/strong\u003e This product can expose you to chemicals including di(2-ethylhexyl)phthalate (dehp) which is known to the State of California to cause cancer, birth defects or other reproductive harm. For more information go to \u003ca href=\"http:\/\/P65Warnings.ca.gov\"\u003eP65Warnings.ca.gov\u003c\/a\u003e.\u003c\/p\u003e\n\u003c!--- cis2:m2lsnZdp ---\u003e\n\u003cp\u003e\u003cb\u003eSpecifications:\u003c\/b\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eCharger Input - Voltage: 24v\u003c\/li\u003e\n\u003cli\u003eCharger Output - Amps: 12a\u003c\/li\u003e\n\u003cli\u003eCharger Output Voltage: 12v\u003c\/li\u003e\n\u003cli\u003eBox Dimensions: 2\"H x 4\"W x 6\"L WT: 0.95 lbs\u003c\/li\u003e\n\u003cli\u003eUPC: 852968002806\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eProduct Manual\u003c\/h3\u003e\n\u003ch4\u003e\n\u003ca href=\"https:\/\/productimageserver.com\/literature\/ownersManual\/54852OM.pdf\" target=\"_blank\"\u003eOwner's Manual (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/productimageserver.com\/literature\/brochure\/54852BR.pdf\" target=\"_blank\"\u003eBrochure (pdf)\u003c\/a\u003e\n\u003c\/h4\u003e\n\u003ch3\u003eProduct Warranty \u003c\/h3\u003e\n\u003ch4 id=\"start\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0724\/2026\/2171\/files\/Mastervolt_Product_Warranty.pdf?v=1755133645\"\u003e\u003cspan\u003eMastervolt Product Warranty\u003c\/span\u003e\u003c\/a\u003e\u003c\/h4\u003e\n\u003ch3\u003e\u003cspan\u003eProduct FAQs\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eN\/A\u003c\/span\u003e\u003c\/p\u003e","brand":"Mastervolt","offers":[{"title":"Default Title","offer_id":50594179907867,"sku":"OGL-54852","price":110.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0724\/2026\/2171\/files\/54852XL.jpg?v=1755090464"},{"product_id":"mastervolt-dc-master-24v-to-12v-converter-12a-w-isolator-81500300","title":"Mastervolt DC Master 24V to 12V Converter - 12A w\/Isolator [81500300]","description":"\u003ch2\u003e\u003cspan style=\"text-decoration: underline;\"\u003eMastervolt DC Master 24V to 12V Converter - 12A w\/Isolator [81500300]\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cb\u003ePower you can rely on\u003c\/b\u003e\u003cbr\u003eThe required voltage for DC current can vary. Some equipment requires 24 V, while onboard equipment usually requires 12 V. For custom DC current, Mastervolt offers a series of compact and made to measure DC-DC converters for both 12 V and 24 V battery systems that offer stable power with the right current for any connected consumer. There is a wide range of DC Master converters available, including insulated and non-insulated models.\u003cbr\u003e\u003cb\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eBenefits\u003c\/b\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eRecreational and semi-professional use.\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eEasy to install using included mounting bracket, screws and fasteners.\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eSmart electronics mean no unnecessary heat generation.\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eContinuous output.\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eInsulated and non-insulated models available.\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eTwo minutes of extra power for short power boosts.\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eExcellent price\/performance ratio.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cb\u003eIntelligent DC-DC converters\u003c\/b\u003e\u003cbr\u003eA large benefit of the DC Master models is their two minutes of extra capacity; ideal if you need a short power boost.\u003cbr\u003e\u003cbr\u003e\u003cb\u003eComplete package DC Master\u003c\/b\u003e\u003cbr\u003eAll DC Master converters are delivered with mounting bracket, screws and fasteners.\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cimg alt=\"Warning\" src=\"https:\/\/productimageserver.com\/prop65\/6pt.png\"\u003e\u003cstrong\u003eWARNING:\u003c\/strong\u003e This product can expose you to chemicals including di(2-ethylhexyl)phthalate (dehp) which is known to the State of California to cause cancer, birth defects or other reproductive harm. For more information go to \u003ca href=\"http:\/\/P65Warnings.ca.gov\"\u003eP65Warnings.ca.gov\u003c\/a\u003e.\u003c\/p\u003e\n\u003ch3\u003eProduct Specifications\u003c\/h3\u003e\n\u003c!--- cis2:m2lsnZdp ---\u003e\n\u003ch2\u003e\u003cspan style=\"text-decoration: underline;\"\u003eMastervolt DC Master 24V to 12V Converter - 12A w\/Isolator [81500300] Product Specifications\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp data-start=\"80\" data-end=\"108\"\u003e\u003cstrong data-start=\"80\" data-end=\"106\"\u003eGeneral Specifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"109\" data-end=\"589\"\u003e\n\u003cli data-start=\"109\" data-end=\"147\"\u003e\n\u003cp data-start=\"111\" data-end=\"147\"\u003e\u003cstrong data-start=\"111\" data-end=\"138\"\u003eNominal Output Voltage:\u003c\/strong\u003e 13.6 V\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"148\" data-end=\"180\"\u003e\n\u003cp data-start=\"150\" data-end=\"180\"\u003e\u003cstrong data-start=\"150\" data-end=\"172\"\u003eMax. Output Power:\u003c\/strong\u003e 245 W\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"181\" data-end=\"216\"\u003e\n\u003cp data-start=\"183\" data-end=\"216\"\u003e\u003cstrong data-start=\"183\" data-end=\"208\"\u003eNominal Output Power:\u003c\/strong\u003e 164 W\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"217\" data-end=\"269\"\u003e\n\u003cp data-start=\"219\" data-end=\"269\"\u003e\u003cstrong data-start=\"219\" data-end=\"262\"\u003eMax. Output Current (2 min. intervals):\u003c\/strong\u003e 18 A\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"270\" data-end=\"309\"\u003e\n\u003cp data-start=\"272\" data-end=\"309\"\u003e\u003cstrong data-start=\"272\" data-end=\"302\"\u003eContinuous Output Current:\u003c\/strong\u003e 12 A\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"310\" data-end=\"345\"\u003e\n\u003cp data-start=\"312\" data-end=\"345\"\u003e\u003cstrong data-start=\"312\" data-end=\"338\"\u003eNominal Input Voltage:\u003c\/strong\u003e 24 V\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"346\" data-end=\"399\"\u003e\n\u003cp data-start=\"348\" data-end=\"399\"\u003e\u003cstrong data-start=\"348\" data-end=\"379\"\u003eInput Voltage Range (max.):\u003c\/strong\u003e 20–32 V DC (35 V)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"400\" data-end=\"431\"\u003e\n\u003cp data-start=\"402\" data-end=\"431\"\u003e\u003cstrong data-start=\"402\" data-end=\"425\"\u003eGalvanic Isolation:\u003c\/strong\u003e Yes\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"432\" data-end=\"455\"\u003e\n\u003cp data-start=\"434\" data-end=\"455\"\u003e\u003cstrong data-start=\"434\" data-end=\"449\"\u003eStabilised:\u003c\/strong\u003e Yes\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"456\" data-end=\"525\"\u003e\n\u003cp data-start=\"458\" data-end=\"525\"\u003e\u003cstrong data-start=\"458\" data-end=\"485\"\u003eDimensions (H x W x D):\u003c\/strong\u003e 167 x 87 x 50 mm \/ 6.6 x 3.4 x 2.0 in\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"526\" data-end=\"558\"\u003e\n\u003cp data-start=\"528\" data-end=\"558\"\u003e\u003cstrong data-start=\"528\" data-end=\"539\"\u003eWeight:\u003c\/strong\u003e 0.59 kg \/ 1.3 lb\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"559\" data-end=\"589\"\u003e\n\u003cp data-start=\"561\" data-end=\"589\"\u003e\u003cstrong data-start=\"561\" data-end=\"576\"\u003eCompliance:\u003c\/strong\u003e CE, E-mark\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"591\" data-end=\"621\"\u003e\u003cstrong data-start=\"591\" data-end=\"619\"\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"622\" data-end=\"819\" data-is-last-node=\"\" data-is-only-node=\"\"\u003e\n\u003cli data-start=\"622\" data-end=\"653\"\u003e\n\u003cp data-start=\"624\" data-end=\"653\"\u003e\u003cstrong data-start=\"624\" data-end=\"643\"\u003eDC Consumption:\u003c\/strong\u003e \u0026lt; 15 mA\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"654\" data-end=\"682\"\u003e\n\u003cp data-start=\"656\" data-end=\"682\"\u003e\u003cstrong data-start=\"656\" data-end=\"672\"\u003eConnections:\u003c\/strong\u003e Fast-on\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"683\" data-end=\"754\"\u003e\n\u003cp data-start=\"685\" data-end=\"754\"\u003e\u003cstrong data-start=\"685\" data-end=\"717\"\u003eTemperature Range (Ambient):\u003c\/strong\u003e -25 °C to 80 °C (derating \u0026gt; 30 °C)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"755\" data-end=\"787\"\u003e\n\u003cp data-start=\"757\" data-end=\"787\"\u003e\u003cstrong data-start=\"757\" data-end=\"769\"\u003eCooling:\u003c\/strong\u003e Natural cooling\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"788\" data-end=\"819\" data-is-last-node=\"\"\u003e\n\u003cp data-start=\"790\" data-end=\"819\" data-is-last-node=\"\"\u003e\u003cstrong data-start=\"790\" data-end=\"812\"\u003eProtection Degree:\u003c\/strong\u003e IP53\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eProduct Manual\u003c\/h3\u003e\n\u003ch4\u003e\n\u003ca href=\"https:\/\/productimageserver.com\/literature\/ownersManual\/57565OM.pdf\" target=\"_blank\"\u003eOwner's Manual (pdf)\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/productimageserver.com\/literature\/brochure\/57565BR.pdf\" target=\"_blank\"\u003eBrochure (pdf)\u003c\/a\u003e\n\u003c\/h4\u003e\n\u003ch3\u003eProduct Warranty \u003c\/h3\u003e\n\u003ch4 id=\"start\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0724\/2026\/2171\/files\/Mastervolt_Product_Warranty.pdf?v=1755133645\"\u003e\u003cspan\u003eMastervolt Product Warranty\u003c\/span\u003e\u003c\/a\u003e\u003c\/h4\u003e\n\u003ch3\u003e\u003cspan\u003eProduct FAQs\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eN\/A\u003c\/span\u003e\u003c\/p\u003e","brand":"Mastervolt","offers":[{"title":"Default Title","offer_id":50594180202779,"sku":"OGL-57565","price":185.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0724\/2026\/2171\/files\/57565XL.jpg?v=1755090466"},{"product_id":"mastervolt-magic-12-12-20-dc-converter-81300400","title":"Mastervolt Magic 12\/12-20 DC Converter [81300400]","description":"\u003ch2\u003e\u003cspan style=\"text-decoration: underline;\"\u003eMastervolt Magic 12\/12-20 DC Converter [81300400]\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cb\u003eFor The Toughest Tasks\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eThe Mac and Magic DC-DC converters are designed for the toughest conditions for professional, semi-professional and recreational purposes. Even under the most extreme conditions, these DC-DC converters operate faultlessly, giving you round-the-clock output when necessary. The sustainability and technologies that underpin the Mastervolt concept have long been proven in practice. With an MTBF of 280,000 hours at full capacity and 24\/7 use, the DC-DC converters are ideal for the toughest tasks and any situation that requires a reliable power supply. \u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eMaking The Best Even Better\u003c\/b\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003eThe reliability and long lifespan of Mastervolt’s DC-DC converters have been established beyond doubt over the past 20 years. While the Mastervolt products have evolved with the latest technological developments, the dimensions and connections have remained the same. As a result it is exceptionally easy to replace one unit with another with only negligible downtime. \u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eMastervolt Green by Heart\u003c\/b\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003eAs part of our constant search for eco-friendly and long-lasting solutions, Mastervolt has developed the Green by Heart program. Its impact on the Mac \u0026amp; Magic DC-DC converters include:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eAn exceptionally effective use of the consumed input current (cos phi) \u0026gt; 0.98!\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eFaster charging of batteries, even with when the input current is limited\u003c\/li\u003e\n\u003cli\u003eUse of top quality components with a long lifespan\u003c\/li\u003e\n\u003cli\u003eSavings in weight and space\u003c\/li\u003e\n\u003cli\u003eFewer installation materials\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cb\u003eMasterBus Compatible\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eFor the DC-DC converters you can use the MasterBus Serial Interface. All you need is a single cable with one connection. Your benefits: Fast and easy installation, plus centralized monitoring, configuration and operation of your system with a MasterView panel.\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eProgrammable via Desktop or Laptop\/PC\u003c\/b\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003eRemote control the Mac or Magic via your laptop or PC or configure your personal preferences. The device has a communication port and easy installation with a PC-Link and MasterAdjust software.\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eEnergy-Saving Dimmer Function\u003c\/b\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003eMany standard light dimmers convert part of the energy to heat and also lose unnecessary energy. The Mastervolt Magic converters regulate the power supply efficiently and without excessive heat build-up, up to 580 watts for optimal safety (multiple Magic converters can be used for multiple lamps).\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eParallel Operation\u003c\/b\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003eIf you have many\/heavy power-consuming devices onboard, the parallel use of several units allows capacities of 40, 60 or more Amps. Advanced high-frequency technology with modern microprocessors ensures minimum power loss when switching from 24 to 12 V and vice versa. \u003c\/p\u003e\n\u003cp\u003e\u003cb\u003ePowerful Selling Points:\u003c\/b\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eReliable and very stable DC supply\u003c\/li\u003e\n\u003cli\u003eFor 12 and 24 V battery systems\u003c\/li\u003e\n\u003cli\u003eParallel switching of multiple units for capacities of 40, 60 or more Amps\u003c\/li\u003e\n\u003cli\u003eBattery charger and dimmer function\u003c\/li\u003e\n\u003cli\u003eAdjustable output voltage\u003c\/li\u003e\n\u003cli\u003eVoltage stabilization for a longer lifespan of halogen lights, etc\u003c\/li\u003e\n\u003cli\u003eCorrosion-proof aluminium casing\u003c\/li\u003e\n\u003cli\u003eShock-proof\u003c\/li\u003e\n\u003cli\u003eTemperature-powered fan for cooling\u003c\/li\u003e\n\u003cli\u003eGenerates limited heat, so installable almost anywhere\u003c\/li\u003e\n\u003cli\u003eFully MasterBus compatible with a MasterBus Serial Interface\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan style=\"text-decoration: underline;\"\u003eProduct Specifications\u003c\/span\u003e\u003c\/h3\u003e\n\u003ch2\u003e\u003cspan style=\"text-decoration: underline;\"\u003eMastervolt Magic 12\/12-20 DC Converter [81300400] Product Specifications\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cb\u003eSpecifications:\u003c\/b\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eNominal output voltage: 13.6V\u003c\/li\u003e\n\u003cli\u003eOutput voltage (adjustable with MasterAdjust): 10-15V\u003c\/li\u003e\n\u003cli\u003eOutput voltage dimmer (adjustable with MasterAdjust): 4-13V\u003c\/li\u003e\n\u003cli\u003eOutput voltage stabilization: 2% at extremes of temperatures, load and input\u003c\/li\u003e\n\u003cli\u003eOutput voltage ripple (peak peak): max. 1%\u003c\/li\u003e\n\u003cli\u003eMax. output power: 300W\u003c\/li\u003e\n\u003cli\u003eNominal output power: 300W\u003c\/li\u003e\n\u003cli\u003eMax. output current: 20A\u003c\/li\u003e\n\u003cli\u003eOutput charge current (3-step mode): 16 A\u003c\/li\u003e\n\u003cli\u003eNominal input voltage: 12V\u003c\/li\u003e\n\u003cli\u003eInput voltage range: 11-16V\u003c\/li\u003e\n\u003cli\u003eInput voltage range (3-step charge mode): 12-16V\u003c\/li\u003e\n\u003cli\u003eLower input set point (adjustable with MasterAdjust): 10V\u003c\/li\u003e\n\u003cli\u003eDelay lower input set point (adjustable with MasterAdjust): 30 sec.\u003c\/li\u003e\n\u003cli\u003eGalvanic isolation: yes\u003c\/li\u003e\n\u003cli\u003eVoltage limited: yes\u003c\/li\u003e\n\u003cli\u003eEfficiency: \u0026gt; 90% at nom. input voltage, full load; peak 92 %\u003c\/li\u003e\n\u003cli\u003eDimmer function: yes, by external momentary switch via fast-on connection, to be activated by DIP switch setting\u003c\/li\u003e\n\u003cli\u003eAlarm contact: yes (fast-on connector)\u003c\/li\u003e\n\u003cli\u003eDimensions, HxWxD: 227 x 154 x 81mm \/ 8.9\" x 6.1\" x 3.2\"\u003c\/li\u003e\n\u003cli\u003eWeight: 1.8kg \/ 4.0lb\u003c\/li\u003e\n\u003cli\u003eApprovals: CE\u003c\/li\u003e\n\u003cli\u003e3-Step charge option: yes (DIP switch settings)\u003c\/li\u003e\n\u003cli\u003eDC consumption: \u0026lt; 115 mA\u003c\/li\u003e\n\u003cli\u003eConnections: screw terminals (max. wire size 16 mm² \/ AWG5)\u003c\/li\u003e\n\u003cli\u003eTemperature range (ambient temp.): -25 °C to 80 °C, derating \u0026gt; 40 °C -13 °F to 176 °F\u003c\/li\u003e\n\u003cli\u003eSound level: \u0026lt; 48 dBA at 1M\u003c\/li\u003e\n\u003cli\u003eProtection degree: IP21\u003c\/li\u003e\n\u003cli\u003eProtections: against over load \u0026amp; over temperature\u003c\/li\u003e\n\u003cli\u003eCooling: maintenance free vario fans\u003c\/li\u003e\n\u003cli\u003eMasterBus compatible: yes, in combination with a MasterBus Serial Interface\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cimg alt=\"Warning\" src=\"https:\/\/productimageserver.com\/prop65\/6pt.png\"\u003e\u003cstrong\u003eWARNING:\u003c\/strong\u003e This product can expose you to chemicals including di(2-ethylhexyl)phthalate (dehp) which is known to the State of California to cause cancer, birth defects or other reproductive harm. For more information go to \u003ca href=\"http:\/\/P65Warnings.ca.gov\"\u003eP65Warnings.ca.gov\u003c\/a\u003e.\u003c\/p\u003e\n\u003c!--- cis2:m2lsnZdp ---\u003e\n\u003ch3\u003eProduct Manual\u003c\/h3\u003e\n\u003ch4\u003e\u003ca href=\"https:\/\/productimageserver.com\/literature\/ownersManual\/65629OM.pdf\" target=\"_blank\"\u003eOwner's Manual (pdf)\u003c\/a\u003e\u003c\/h4\u003e\n\u003ch3\u003eProduct Warranty \u003c\/h3\u003e\n\u003ch4 id=\"start\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0724\/2026\/2171\/files\/Mastervolt_Product_Warranty.pdf?v=1755133645\"\u003e\u003cspan\u003eMastervolt Product Warranty\u003c\/span\u003e\u003c\/a\u003e\u003c\/h4\u003e\n\u003ch3\u003e\u003cspan\u003eProduct FAQs\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eN\/A\u003c\/span\u003e\u003c\/p\u003e","brand":"Mastervolt","offers":[{"title":"Default Title","offer_id":50594180628763,"sku":"OGL-65629","price":481.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0724\/2026\/2171\/files\/65629XL.jpg?v=1755090468"},{"product_id":"furuno-12v-24v-7-amp-converter-f-drs12ax-x-class-open-array-newmar-new-12v-24v-7a","title":"Furuno 12V-24V 7 Amp Converter for DRS12AX X-Class Open Array - Newmar [NEW-12V-24V-7A]","description":"\u003ch2\u003e\u003cspan style=\"text-decoration: underline;\"\u003eFuruno 12V-24V 7 Amp Converter for DRS12AX X-Class Open Array - Newmar [NEW-12V-24V-7A]\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch2\u003eDescription\u003c\/h2\u003e\n\u003cp\u003eNewmar 12-24-7 Step Up Dc-Dc Converter 7amp Continuous\u003c\/p\u003e\n\u003cp\u003eThese \"UP\" converters produce 24 volts from 12 volt systems and are ideal for managing dual voltage applications on marine vessels without having to install a 24 volt battery and dedicated charging system. Choose from two types depending on your application:\u003c\/p\u003e\n\u003cp\u003eIn the Standard, Non-Isolated Series the 12V input and 24V output share a common negative ground and are ideal when installing certain electronics that operate better on 24 volts when a robust 12 volt system exists. Models available in outputs of 7, 16 and 25 amps.\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eStandard, Non-Isolated Series\u003c\/b\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eIntended for use on negative ground systems\u003c\/li\u003e\n\u003cli\u003e10 -15 VDC input range\u003c\/li\u003e\n\u003cli\u003e7 Amp output\u003c\/li\u003e\n\u003cli\u003eCurrent limited, voltage spike suppression, automatic thermal shutdown and recovery\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eProduct Specifications\u003c\/h3\u003e\n\u003ch2\u003e\u003cspan style=\"text-decoration: underline;\"\u003eFuruno 12V-24V 7 Amp Converter for DRS12AX X-Class Open Array - Newmar [NEW-12V-24V-7A] Product Specifications\u003c\/span\u003e\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10–15 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e27.2 V DC ±5% (at extreme temperature, load, and input tolerances)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRipple\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 100 mV peak-to-peak\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRegulation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e±5% line \/ load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDuty Cycle\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIntermittent: 2 minutes, 20% duty Continuous: 24 hours, 100% duty\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e−25 °C to +30 °C; derates linearly from 30 °C to 0% output at 80 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable style=\"font-size: 0.875rem;\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDetail\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEfficiency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e93% (typical)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnclosure Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAnodized aluminum and glass-filled polycarbonate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnvironmental Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDust, water, and impact resistant — \u003cstrong\u003eIP53\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTerminal Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFront-panel terminal block\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Indicator\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGreen LED\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/productimageserver.com\/prop65\/6pt.png\" alt=\"Warning\"\u003e\u003cstrong\u003eWARNING:\u003c\/strong\u003e This product can expose you to chemicals which are known to the State of California to cause cancer, birth defects or other reproductive harm. For more information go to \u003ca href=\"http:\/\/P65Warnings.ca.gov\"\u003eP65Warnings.ca.gov\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThis product may not be returned to the original point of purchase. Please contact the manufacturer directly with any issues or concerns.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003eProduct Manual\u003c\/h3\u003e\n\u003cp\u003eN\/A\u003c\/p\u003e\n\u003ch3\u003eProduct Warranty\u003c\/h3\u003e\n\u003ch2 data-start=\"344\" data-end=\"365\"\u003eWarranty Repairs\u003c\/h2\u003e\n\u003cp data-start=\"367\" data-end=\"810\"\u003eWarranty repairs are provided for a period of \u003cstrong data-start=\"413\" data-end=\"450\"\u003etwo (2) years for parts and labor\u003c\/strong\u003e from the date of purchase or installation. The warranty start date shall not exceed \u003cstrong data-start=\"535\" data-end=\"559\"\u003eeighteen (18) months\u003c\/strong\u003e from the original date of purchase by an authorized dealer from the manufacturer. This warranty applies only to \u003cstrong data-start=\"672\" data-end=\"689\"\u003enew equipment\u003c\/strong\u003e that has been properly installed, operated, and maintained in accordance with the manufacturer’s published instructions.\u003c\/p\u003e\n\u003cp data-start=\"812\" data-end=\"1197\"\u003eAll products returned by mail or parcel service must be \u003cstrong data-start=\"868\" data-end=\"909\"\u003esecurely packaged and shipped prepaid\u003c\/strong\u003e to an Authorized Service Center. A \u003cstrong data-start=\"945\" data-end=\"987\"\u003eReturn Merchandise Authorization (RMA)\u003c\/strong\u003e is required for all returns and must be obtained prior to shipment. Insurance is recommended but not required. The manufacturer and its service partners are not responsible for damage incurred during shipping.\u003c\/p\u003e\n\u003cp data-start=\"1199\" data-end=\"1376\"\u003eTo verify warranty status, the \u003cstrong data-start=\"1230\" data-end=\"1247\"\u003eserial number\u003c\/strong\u003e and\/or a \u003cstrong data-start=\"1257\" data-end=\"1295\"\u003ecopy of the original sales receipt\u003c\/strong\u003e must be provided. Repairs are completed on a \u003cstrong data-start=\"1341\" data-end=\"1369\"\u003efirst-come, first-served\u003c\/strong\u003e basis.\u003c\/p\u003e\n\u003cp data-start=\"1378\" data-end=\"1595\"\u003eCustomers must remove all \u003cstrong data-start=\"1404\" data-end=\"1436\"\u003enon-manufacturer accessories\u003c\/strong\u003e (including chart cards, custom brackets, or mounts) prior to shipment. The manufacturer is not responsible for missing or damaged third-party or custom items.\u003c\/p\u003e\n\u003cp data-start=\"1597\" data-end=\"1947\"\u003eEquipment repaired under warranty will be returned using the \u003cstrong data-start=\"1658\" data-end=\"1682\"\u003esame shipping method\u003c\/strong\u003e by which it was received. The manufacturer will cover return shipping costs up to \u003cstrong data-start=\"1765\" data-end=\"1786\"\u003eThree-Day service\u003c\/strong\u003e only. Expedited shipping options may be requested at the customer’s or dealer’s expense. Incoming freight to the service facility is not covered under warranty.\u003c\/p\u003e\n\u003cp data-start=\"1949\" data-end=\"2187\"\u003eIf a unit returned for warranty service is found to be \u003cstrong data-start=\"2004\" data-end=\"2039\"\u003eoperating within specifications\u003c\/strong\u003e, a diagnostic labor charge (minimum one (1) hour at the prevailing service rate) may apply, even if the product remains within the warranty period.\u003c\/p\u003e\n\u003ch2 data-start=\"2194\" data-end=\"2215\"\u003eLimited Warranty\u003c\/h2\u003e\n\u003cp data-start=\"2217\" data-end=\"2309\"\u003eWarranty repairs must be performed by an \u003cstrong data-start=\"2258\" data-end=\"2308\"\u003eAuthorized Dealer or Authorized Service Center\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-start=\"2311\" data-end=\"2521\"\u003eThe Limited Warranty provides a \u003cstrong data-start=\"2343\" data-end=\"2375\"\u003etwo (2) year parts and labor\u003c\/strong\u003e warranty from the date of purchase or installation, not to exceed \u003cstrong data-start=\"2442\" data-end=\"2466\"\u003eeighteen (18) months\u003c\/strong\u003e from the original shipment date from the manufacturer.\u003c\/p\u003e\n\u003cul data-start=\"2523\" data-end=\"2786\"\u003e\n\u003cli data-start=\"2523\" data-end=\"2593\"\u003e\n\u003cp data-start=\"2525\" data-end=\"2593\"\u003e\u003cstrong data-start=\"2525\" data-end=\"2562\"\u003eMagnetrons and microwave devices:\u003c\/strong\u003e One (1) year parts and labor\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2594\" data-end=\"2674\"\u003e\n\u003cp data-start=\"2596\" data-end=\"2674\"\u003e\u003cstrong data-start=\"2596\" data-end=\"2612\"\u003eTransducers:\u003c\/strong\u003e Two (2) years parts only (labor and related costs excluded)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2675\" data-end=\"2786\"\u003e\n\u003cp data-start=\"2677\" data-end=\"2786\"\u003e\u003cstrong data-start=\"2677\" data-end=\"2701\"\u003eWaterproof products:\u003c\/strong\u003e Guaranteed waterproof for two (2) years, as defined by applicable marine standards\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"2788\" data-end=\"2899\"\u003eWater intrusion caused by \u003cstrong data-start=\"2814\" data-end=\"2883\"\u003eimproper installation, pressure washing, submersion, or corrosion\u003c\/strong\u003e is not covered.\u003c\/p\u003e\n\u003cp data-start=\"2901\" data-end=\"3194\"\u003eProducts approved for warranty repair may be \u003cstrong data-start=\"2946\" data-end=\"2970\"\u003erepaired or replaced\u003c\/strong\u003e with new, refurbished, or equivalent products at the manufacturer’s sole discretion. Warranty coverage continues for the remainder of the original warranty period. All replaced parts become the property of the manufacturer.\u003c\/p\u003e\n\u003cp data-start=\"3196\" data-end=\"3318\"\u003eOnboard warranty service and travel time are only available if the equipment was installed by an \u003cstrong data-start=\"3293\" data-end=\"3317\"\u003eAuthorized Installer\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch2 data-start=\"3325\" data-end=\"3349\"\u003eWarranty Exclusions\u003c\/h2\u003e\n\u003cp data-start=\"3351\" data-end=\"3436\"\u003eThis warranty covers \u003cstrong data-start=\"3372\" data-end=\"3416\"\u003edefects in materials or workmanship only\u003c\/strong\u003e. It does not cover:\u003c\/p\u003e\n\u003cul data-start=\"3438\" data-end=\"4164\"\u003e\n\u003cli data-start=\"3438\" data-end=\"3524\"\u003e\n\u003cp data-start=\"3440\" data-end=\"3524\"\u003eSea trials, haul-outs, removal\/reinstallation, commissioning, or setup adjustments\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3525\" data-end=\"3591\"\u003e\n\u003cp data-start=\"3527\" data-end=\"3591\"\u003eRoutine maintenance or consumables (fuses, lamps, paper, etc.)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3592\" data-end=\"3722\"\u003e\n\u003cp data-start=\"3594\" data-end=\"3722\"\u003eDamage caused by accident, misuse, abuse, negligence, improper installation, power irregularities, vandalism, or water ingress\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3723\" data-end=\"3764\"\u003e\n\u003cp data-start=\"3725\" data-end=\"3764\"\u003eUnauthorized modifications or repairs\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3765\" data-end=\"3820\"\u003e\n\u003cp data-start=\"3767\" data-end=\"3820\"\u003eDamage caused by non-approved power or data cabling\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3821\" data-end=\"3875\"\u003e\n\u003cp data-start=\"3823\" data-end=\"3875\"\u003eActs of God (lightning, flooding, extreme weather)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3876\" data-end=\"3918\"\u003e\n\u003cp data-start=\"3878\" data-end=\"3918\"\u003eShipping damage (carrier claims apply)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3919\" data-end=\"3980\"\u003e\n\u003cp data-start=\"3921\" data-end=\"3980\"\u003eIncorrect product or transducer selection or installation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3981\" data-end=\"4041\"\u003e\n\u003cp data-start=\"3983\" data-end=\"4041\"\u003eElectrical interference, voltage issues, or system noise\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"4042\" data-end=\"4100\"\u003e\n\u003cp data-start=\"4044\" data-end=\"4100\"\u003eLCD pixel anomalies within manufacturer specifications\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"4101\" data-end=\"4164\"\u003e\n\u003cp data-start=\"4103\" data-end=\"4164\"\u003eProducts with removed, altered, or illegible serial numbers\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"4166\" data-end=\"4255\"\u003eFailure to follow published installation and operating guidelines will void the warranty.\u003c\/p\u003e\n\u003ch2 data-start=\"4262\" data-end=\"4288\"\u003eWarranty Labor Limits\u003c\/h2\u003e\n\u003cp data-start=\"4290\" data-end=\"4521\"\u003eWarranty labor allowances vary by product category and are subject to \u003cstrong data-start=\"4360\" data-end=\"4400\"\u003emaximum hourly rates and time limits\u003c\/strong\u003e. Labor exceeding these limits requires \u003cstrong data-start=\"4440\" data-end=\"4471\"\u003eprior written authorization\u003c\/strong\u003e from a Service Manager or Warranty Administrator.\u003c\/p\u003e\n\u003cp data-start=\"4523\" data-end=\"4576\"\u003eExpenses not covered include, but are not limited to:\u003c\/p\u003e\n\u003cul data-start=\"4577\" data-end=\"4782\"\u003e\n\u003cli data-start=\"4577\" data-end=\"4631\"\u003e\n\u003cp data-start=\"4579\" data-end=\"4631\"\u003eMeals, lodging, tolls, docking fees, launch services\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"4632\" data-end=\"4667\"\u003e\n\u003cp data-start=\"4634\" data-end=\"4667\"\u003eTransportation or rental vehicles\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"4668\" data-end=\"4721\"\u003e\n\u003cp data-start=\"4670\" data-end=\"4721\"\u003eLocal taxes, customs fees, or communication charges\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"4722\" data-end=\"4782\"\u003e\n\u003cp data-start=\"4724\" data-end=\"4782\"\u003eVessel towing, hauling, or transport to a service location\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"4784\" data-end=\"4886\"\u003eMaximum liability under this warranty shall not exceed the \u003cstrong data-start=\"4843\" data-end=\"4870\"\u003eoriginal purchase price\u003c\/strong\u003e of the product.\u003c\/p\u003e\n\u003ch2 data-start=\"4893\" data-end=\"4946\"\u003eWarranty Service Outside the Country of Purchase\u003c\/h2\u003e\n\u003cp data-start=\"4948\" data-end=\"5180\"\u003eWarranty coverage may be honored in foreign ports under the same terms and limitations, excluding \u003cstrong data-start=\"5046\" data-end=\"5070\"\u003egray-market products\u003c\/strong\u003e. Customers must contact the local authorized service agent for assistance and authorization prior to service.\u003c\/p\u003e\n\u003ch2 data-start=\"5187\" data-end=\"5213\"\u003eWarranty Registration\u003c\/h2\u003e\n\u003cp data-start=\"5215\" data-end=\"5454\"\u003eProducts should be registered through the manufacturer’s official support portal to activate warranty coverage and expedite service. Warranty coverage is \u003cstrong data-start=\"5369\" data-end=\"5385\"\u003etransferable\u003c\/strong\u003e, but the original registration date remains the warranty start date.\u003c\/p\u003e\n\u003cp data-start=\"5456\" data-end=\"5562\"\u003eWarranty is tracked by \u003cstrong data-start=\"5479\" data-end=\"5496\"\u003eserial number\u003c\/strong\u003e. Proof of purchase may be required if registration is incomplete.\u003c\/p\u003e\n\u003ch2 data-start=\"5569\" data-end=\"5607\"\u003eWarranty Claims \u0026amp; Labor Invoicing\u003c\/h2\u003e\n\u003cp data-start=\"5609\" data-end=\"5755\"\u003eAll warranty labor claims must be submitted using the \u003cstrong data-start=\"5663\" data-end=\"5695\"\u003estandard warranty claim form\u003c\/strong\u003e within \u003cstrong data-start=\"5703\" data-end=\"5723\"\u003ethirty (30) days\u003c\/strong\u003e of repair. Claims must include:\u003c\/p\u003e\n\u003cul data-start=\"5757\" data-end=\"5922\"\u003e\n\u003cli data-start=\"5757\" data-end=\"5784\"\u003e\n\u003cp data-start=\"5759\" data-end=\"5784\"\u003eModel and serial number\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"5785\" data-end=\"5833\"\u003e\n\u003cp data-start=\"5787\" data-end=\"5833\"\u003eOwner and vessel information (if applicable)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"5834\" data-end=\"5881\"\u003e\n\u003cp data-start=\"5836\" data-end=\"5881\"\u003eDetailed failure description and resolution\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"5882\" data-end=\"5922\"\u003e\n\u003cp data-start=\"5884\" data-end=\"5922\"\u003eCopy of service report or work order\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"5924\" data-end=\"5971\"\u003eIncomplete or late submissions may be rejected.\u003c\/p\u003e\n\u003ch2 data-start=\"5978\" data-end=\"6021\"\u003eWarranty Parts, Replacements \u0026amp; Returns\u003c\/h2\u003e\n\u003cp data-start=\"6023\" data-end=\"6207\"\u003eThe manufacturer reserves the right to \u003cstrong data-start=\"6062\" data-end=\"6083\"\u003erepair or replace\u003c\/strong\u003e defective units or components. Replacement parts may be invoiced pending return of defective items and inspection approval.\u003c\/p\u003e\n\u003cp data-start=\"6209\" data-end=\"6229\"\u003eAll returns require:\u003c\/p\u003e\n\u003cul data-start=\"6230\" data-end=\"6362\"\u003e\n\u003cli data-start=\"6230\" data-end=\"6254\"\u003e\n\u003cp data-start=\"6232\" data-end=\"6254\"\u003eA valid \u003cstrong data-start=\"6240\" data-end=\"6254\"\u003eRMA number\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"6255\" data-end=\"6281\"\u003e\n\u003cp data-start=\"6257\" data-end=\"6281\"\u003eFreight prepaid shipment\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"6282\" data-end=\"6362\"\u003e\n\u003cp data-start=\"6284\" data-end=\"6362\"\u003eComplete documentation of failure and requested action (credit or replacement)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"6364\" data-end=\"6477\"\u003eReplacement parts are covered by a \u003cstrong data-start=\"6399\" data-end=\"6438\"\u003eninety (90) day parts-only warranty\u003c\/strong\u003e from shipment date. Labor is excluded.\u003c\/p\u003e\n\u003ch2 data-start=\"6484\" data-end=\"6509\"\u003eNon-Warranty Repairs\u003c\/h2\u003e\n\u003cp data-start=\"6511\" data-end=\"6680\"\u003eNon-warranty repairs are performed on a \u003cstrong data-start=\"6551\" data-end=\"6579\"\u003etime and materials basis\u003c\/strong\u003e at the prevailing service rate, with a one (1) hour minimum. Estimates may be provided upon request.\u003c\/p\u003e\n\u003cp data-start=\"6682\" data-end=\"6763\"\u003eRepairs are warranted for \u003cstrong data-start=\"6708\" data-end=\"6728\"\u003eninety (90) days\u003c\/strong\u003e and limited to the parts replaced.\u003c\/p\u003e\n\u003ch2 data-start=\"6770\" data-end=\"6789\"\u003eParts Ordering\u003c\/h2\u003e\n\u003cp data-start=\"6791\" data-end=\"7015\"\u003eWhen ordering parts, the \u003cstrong data-start=\"6816\" data-end=\"6852\"\u003ecorrect manufacturer part number\u003c\/strong\u003e is required. Serial number verification may be necessary to ensure compatibility. Incorrect or trial-installed parts may be subject to restocking or testing fees.\u003c\/p\u003e\n\u003ch2 data-start=\"7022\" data-end=\"7038\"\u003eRMA Process\u003c\/h2\u003e\n\u003cp data-start=\"7040\" data-end=\"7242\"\u003eAn \u003cstrong data-start=\"7043\" data-end=\"7069\"\u003eRMA number is required\u003c\/strong\u003e for all returns, credits, or warranty replacements. RMA numbers are valid for \u003cstrong data-start=\"7148\" data-end=\"7165\"\u003esix (6) weeks\u003c\/strong\u003e from issuance. Returns received without proper authorization may be refused.\u003c\/p\u003e\n\u003cp data-start=\"7244\" data-end=\"7314\"\u003eIssuance of an RMA does \u003cstrong data-start=\"7268\" data-end=\"7313\"\u003enot guarantee credit or warranty approval\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 data-start=\"7244\" data-end=\"7314\"\u003eProduct FAQs\u003c\/h3\u003e\n\u003cp\u003eN\/A\u003c\/p\u003e\n\u003c!--- cis2:m2lsnZdp ---\u003e","brand":"Furuno","offers":[{"title":"Default Title","offer_id":51525243994395,"sku":"OGL-65923","price":828.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0724\/2026\/2171\/files\/65923XL.jpg?v=1766515395"},{"product_id":"furuno-12v-24v-dc-16-amp-converter-f-drs25ax-x-class-open-array-newmar-new-12v-24v-16a","title":"Furuno 12V-24V DC 16 Amp Converter for DRS25AX X-Class Open Array - Newmar [NEW-12V-24V-16A]","description":"\u003ch2\u003e\u003cspan style=\"text-decoration: underline;\"\u003eFuruno 12V-24V DC 16 Amp Converter for DRS25AX X-Class Open Array - Newmar [NEW-12V-24V-16A]\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch2\u003eDescription\u003c\/h2\u003e\n\u003cp\u003e12V-24V DC 16 Amp Converter for DRS25AX X-Class Open Array - Newmar\u003c\/p\u003e\n\u003ch3\u003eProduct Specifications\u003c\/h3\u003e\n\u003ch2\u003e\u003cspan style=\"text-decoration: underline;\"\u003eFuruno 12V-24V DC 16 Amp Converter for DRS25AX X-Class Open Array - Newmar [NEW-12V-24V-16A] Product Specifications\u003c\/span\u003e\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Name\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFuruno 12 V–24 V DC 16 Amp Converter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePart Number \/ MPN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNEW-12V-24V-16A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCompatible Radar\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDRS25AX X-Class Open Array (and other Furuno systems requiring 24 V from a 12 V supply)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10–15 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e27.2 V DC ±5% (regulated under line, load, and temperature extremes)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Output Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRipple\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 100 mV peak-to-peak\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVoltage Regulation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e±5% (line and load)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEfficiency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e93% (typical)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDuty Cycle – Intermittent\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 minutes ON, 20% duty cycle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDuty Cycle – Continuous\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24 hours, 100% duty cycle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e−25 °C to +30 °C (derates linearly from 30 °C to 0% output at 80 °C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnclosure Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAnodized aluminum and glass-filled polycarbonate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnvironmental Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDust, water, and impact resistant — \u003cstrong\u003eIP53\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTerminal Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFront-panel terminal block\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStatus Indicator\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGreen LED output indicator\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUsage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSupplies regulated 24 V DC power for Furuno radar systems on vessels with a 12 V electrical system\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInstallation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTypically mounted near vessel power distribution panel with proper circuit protection (refer to Furuno installation manual)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMarine Grade\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDesigned for marine electronics installations subject to vibration, moisture, and temperature variation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUPC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e611679371027\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/productimageserver.com\/prop65\/6pt.png\" alt=\"Warning\"\u003e\u003cstrong\u003eWARNING:\u003c\/strong\u003e This product can expose you to chemicals which are known to the State of California to cause cancer, birth defects or other reproductive harm. For more information go to \u003ca href=\"http:\/\/P65Warnings.ca.gov\"\u003eP65Warnings.ca.gov\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThis product may not be returned to the original point of purchase. Please contact the manufacturer directly with any issues or concerns.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003eProduct Manual\u003c\/h3\u003e\n\u003cp\u003eN\/A\u003c\/p\u003e\n\u003ch3\u003eProduct Warranty\u003c\/h3\u003e\n\u003ch2 data-start=\"344\" data-end=\"365\"\u003eWarranty Repairs\u003c\/h2\u003e\n\u003cp data-start=\"367\" data-end=\"810\"\u003eWarranty repairs are provided for a period of \u003cstrong data-start=\"413\" data-end=\"450\"\u003etwo (2) years for parts and labor\u003c\/strong\u003e from the date of purchase or installation. The warranty start date shall not exceed \u003cstrong data-start=\"535\" data-end=\"559\"\u003eeighteen (18) months\u003c\/strong\u003e from the original date of purchase by an authorized dealer from the manufacturer. This warranty applies only to \u003cstrong data-start=\"672\" data-end=\"689\"\u003enew equipment\u003c\/strong\u003e that has been properly installed, operated, and maintained in accordance with the manufacturer’s published instructions.\u003c\/p\u003e\n\u003cp data-start=\"812\" data-end=\"1197\"\u003eAll products returned by mail or parcel service must be \u003cstrong data-start=\"868\" data-end=\"909\"\u003esecurely packaged and shipped prepaid\u003c\/strong\u003e to an Authorized Service Center. A \u003cstrong data-start=\"945\" data-end=\"987\"\u003eReturn Merchandise Authorization (RMA)\u003c\/strong\u003e is required for all returns and must be obtained prior to shipment. Insurance is recommended but not required. The manufacturer and its service partners are not responsible for damage incurred during shipping.\u003c\/p\u003e\n\u003cp data-start=\"1199\" data-end=\"1376\"\u003eTo verify warranty status, the \u003cstrong data-start=\"1230\" data-end=\"1247\"\u003eserial number\u003c\/strong\u003e and\/or a \u003cstrong data-start=\"1257\" data-end=\"1295\"\u003ecopy of the original sales receipt\u003c\/strong\u003e must be provided. Repairs are completed on a \u003cstrong data-start=\"1341\" data-end=\"1369\"\u003efirst-come, first-served\u003c\/strong\u003e basis.\u003c\/p\u003e\n\u003cp data-start=\"1378\" data-end=\"1595\"\u003eCustomers must remove all \u003cstrong data-start=\"1404\" data-end=\"1436\"\u003enon-manufacturer accessories\u003c\/strong\u003e (including chart cards, custom brackets, or mounts) prior to shipment. The manufacturer is not responsible for missing or damaged third-party or custom items.\u003c\/p\u003e\n\u003cp data-start=\"1597\" data-end=\"1947\"\u003eEquipment repaired under warranty will be returned using the \u003cstrong data-start=\"1658\" data-end=\"1682\"\u003esame shipping method\u003c\/strong\u003e by which it was received. The manufacturer will cover return shipping costs up to \u003cstrong data-start=\"1765\" data-end=\"1786\"\u003eThree-Day service\u003c\/strong\u003e only. Expedited shipping options may be requested at the customer’s or dealer’s expense. Incoming freight to the service facility is not covered under warranty.\u003c\/p\u003e\n\u003cp data-start=\"1949\" data-end=\"2187\"\u003eIf a unit returned for warranty service is found to be \u003cstrong data-start=\"2004\" data-end=\"2039\"\u003eoperating within specifications\u003c\/strong\u003e, a diagnostic labor charge (minimum one (1) hour at the prevailing service rate) may apply, even if the product remains within the warranty period.\u003c\/p\u003e\n\u003ch2 data-start=\"2194\" data-end=\"2215\"\u003eLimited Warranty\u003c\/h2\u003e\n\u003cp data-start=\"2217\" data-end=\"2309\"\u003eWarranty repairs must be performed by an \u003cstrong data-start=\"2258\" data-end=\"2308\"\u003eAuthorized Dealer or Authorized Service Center\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-start=\"2311\" data-end=\"2521\"\u003eThe Limited Warranty provides a \u003cstrong data-start=\"2343\" data-end=\"2375\"\u003etwo (2) year parts and labor\u003c\/strong\u003e warranty from the date of purchase or installation, not to exceed \u003cstrong data-start=\"2442\" data-end=\"2466\"\u003eeighteen (18) months\u003c\/strong\u003e from the original shipment date from the manufacturer.\u003c\/p\u003e\n\u003cul data-start=\"2523\" data-end=\"2786\"\u003e\n\u003cli data-start=\"2523\" data-end=\"2593\"\u003e\n\u003cp data-start=\"2525\" data-end=\"2593\"\u003e\u003cstrong data-start=\"2525\" data-end=\"2562\"\u003eMagnetrons and microwave devices:\u003c\/strong\u003e One (1) year parts and labor\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2594\" data-end=\"2674\"\u003e\n\u003cp data-start=\"2596\" data-end=\"2674\"\u003e\u003cstrong data-start=\"2596\" data-end=\"2612\"\u003eTransducers:\u003c\/strong\u003e Two (2) years parts only (labor and related costs excluded)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2675\" data-end=\"2786\"\u003e\n\u003cp data-start=\"2677\" data-end=\"2786\"\u003e\u003cstrong data-start=\"2677\" data-end=\"2701\"\u003eWaterproof products:\u003c\/strong\u003e Guaranteed waterproof for two (2) years, as defined by applicable marine standards\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"2788\" data-end=\"2899\"\u003eWater intrusion caused by \u003cstrong data-start=\"2814\" data-end=\"2883\"\u003eimproper installation, pressure washing, submersion, or corrosion\u003c\/strong\u003e is not covered.\u003c\/p\u003e\n\u003cp data-start=\"2901\" data-end=\"3194\"\u003eProducts approved for warranty repair may be \u003cstrong data-start=\"2946\" data-end=\"2970\"\u003erepaired or replaced\u003c\/strong\u003e with new, refurbished, or equivalent products at the manufacturer’s sole discretion. Warranty coverage continues for the remainder of the original warranty period. All replaced parts become the property of the manufacturer.\u003c\/p\u003e\n\u003cp data-start=\"3196\" data-end=\"3318\"\u003eOnboard warranty service and travel time are only available if the equipment was installed by an \u003cstrong data-start=\"3293\" data-end=\"3317\"\u003eAuthorized Installer\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch2 data-start=\"3325\" data-end=\"3349\"\u003eWarranty Exclusions\u003c\/h2\u003e\n\u003cp data-start=\"3351\" data-end=\"3436\"\u003eThis warranty covers \u003cstrong data-start=\"3372\" data-end=\"3416\"\u003edefects in materials or workmanship only\u003c\/strong\u003e. It does not cover:\u003c\/p\u003e\n\u003cul data-start=\"3438\" data-end=\"4164\"\u003e\n\u003cli data-start=\"3438\" data-end=\"3524\"\u003e\n\u003cp data-start=\"3440\" data-end=\"3524\"\u003eSea trials, haul-outs, removal\/reinstallation, commissioning, or setup adjustments\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3525\" data-end=\"3591\"\u003e\n\u003cp data-start=\"3527\" data-end=\"3591\"\u003eRoutine maintenance or consumables (fuses, lamps, paper, etc.)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3592\" data-end=\"3722\"\u003e\n\u003cp data-start=\"3594\" data-end=\"3722\"\u003eDamage caused by accident, misuse, abuse, negligence, improper installation, power irregularities, vandalism, or water ingress\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3723\" data-end=\"3764\"\u003e\n\u003cp data-start=\"3725\" data-end=\"3764\"\u003eUnauthorized modifications or repairs\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3765\" data-end=\"3820\"\u003e\n\u003cp data-start=\"3767\" data-end=\"3820\"\u003eDamage caused by non-approved power or data cabling\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3821\" data-end=\"3875\"\u003e\n\u003cp data-start=\"3823\" data-end=\"3875\"\u003eActs of God (lightning, flooding, extreme weather)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3876\" data-end=\"3918\"\u003e\n\u003cp data-start=\"3878\" data-end=\"3918\"\u003eShipping damage (carrier claims apply)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3919\" data-end=\"3980\"\u003e\n\u003cp data-start=\"3921\" data-end=\"3980\"\u003eIncorrect product or transducer selection or installation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3981\" data-end=\"4041\"\u003e\n\u003cp data-start=\"3983\" data-end=\"4041\"\u003eElectrical interference, voltage issues, or system noise\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"4042\" data-end=\"4100\"\u003e\n\u003cp data-start=\"4044\" data-end=\"4100\"\u003eLCD pixel anomalies within manufacturer specifications\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"4101\" data-end=\"4164\"\u003e\n\u003cp data-start=\"4103\" data-end=\"4164\"\u003eProducts with removed, altered, or illegible serial numbers\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"4166\" data-end=\"4255\"\u003eFailure to follow published installation and operating guidelines will void the warranty.\u003c\/p\u003e\n\u003ch2 data-start=\"4262\" data-end=\"4288\"\u003eWarranty Labor Limits\u003c\/h2\u003e\n\u003cp data-start=\"4290\" data-end=\"4521\"\u003eWarranty labor allowances vary by product category and are subject to \u003cstrong data-start=\"4360\" data-end=\"4400\"\u003emaximum hourly rates and time limits\u003c\/strong\u003e. Labor exceeding these limits requires \u003cstrong data-start=\"4440\" data-end=\"4471\"\u003eprior written authorization\u003c\/strong\u003e from a Service Manager or Warranty Administrator.\u003c\/p\u003e\n\u003cp data-start=\"4523\" data-end=\"4576\"\u003eExpenses not covered include, but are not limited to:\u003c\/p\u003e\n\u003cul data-start=\"4577\" data-end=\"4782\"\u003e\n\u003cli data-start=\"4577\" data-end=\"4631\"\u003e\n\u003cp data-start=\"4579\" data-end=\"4631\"\u003eMeals, lodging, tolls, docking fees, launch services\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"4632\" data-end=\"4667\"\u003e\n\u003cp data-start=\"4634\" data-end=\"4667\"\u003eTransportation or rental vehicles\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"4668\" data-end=\"4721\"\u003e\n\u003cp data-start=\"4670\" data-end=\"4721\"\u003eLocal taxes, customs fees, or communication charges\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"4722\" data-end=\"4782\"\u003e\n\u003cp data-start=\"4724\" data-end=\"4782\"\u003eVessel towing, hauling, or transport to a service location\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"4784\" data-end=\"4886\"\u003eMaximum liability under this warranty shall not exceed the \u003cstrong data-start=\"4843\" data-end=\"4870\"\u003eoriginal purchase price\u003c\/strong\u003e of the product.\u003c\/p\u003e\n\u003ch2 data-start=\"4893\" data-end=\"4946\"\u003eWarranty Service Outside the Country of Purchase\u003c\/h2\u003e\n\u003cp data-start=\"4948\" data-end=\"5180\"\u003eWarranty coverage may be honored in foreign ports under the same terms and limitations, excluding \u003cstrong data-start=\"5046\" data-end=\"5070\"\u003egray-market products\u003c\/strong\u003e. Customers must contact the local authorized service agent for assistance and authorization prior to service.\u003c\/p\u003e\n\u003ch2 data-start=\"5187\" data-end=\"5213\"\u003eWarranty Registration\u003c\/h2\u003e\n\u003cp data-start=\"5215\" data-end=\"5454\"\u003eProducts should be registered through the manufacturer’s official support portal to activate warranty coverage and expedite service. Warranty coverage is \u003cstrong data-start=\"5369\" data-end=\"5385\"\u003etransferable\u003c\/strong\u003e, but the original registration date remains the warranty start date.\u003c\/p\u003e\n\u003cp data-start=\"5456\" data-end=\"5562\"\u003eWarranty is tracked by \u003cstrong data-start=\"5479\" data-end=\"5496\"\u003eserial number\u003c\/strong\u003e. Proof of purchase may be required if registration is incomplete.\u003c\/p\u003e\n\u003ch2 data-start=\"5569\" data-end=\"5607\"\u003eWarranty Claims \u0026amp; Labor Invoicing\u003c\/h2\u003e\n\u003cp data-start=\"5609\" data-end=\"5755\"\u003eAll warranty labor claims must be submitted using the \u003cstrong data-start=\"5663\" data-end=\"5695\"\u003estandard warranty claim form\u003c\/strong\u003e within \u003cstrong data-start=\"5703\" data-end=\"5723\"\u003ethirty (30) days\u003c\/strong\u003e of repair. Claims must include:\u003c\/p\u003e\n\u003cul data-start=\"5757\" data-end=\"5922\"\u003e\n\u003cli data-start=\"5757\" data-end=\"5784\"\u003e\n\u003cp data-start=\"5759\" data-end=\"5784\"\u003eModel and serial number\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"5785\" data-end=\"5833\"\u003e\n\u003cp data-start=\"5787\" data-end=\"5833\"\u003eOwner and vessel information (if applicable)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"5834\" data-end=\"5881\"\u003e\n\u003cp data-start=\"5836\" data-end=\"5881\"\u003eDetailed failure description and resolution\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"5882\" data-end=\"5922\"\u003e\n\u003cp data-start=\"5884\" data-end=\"5922\"\u003eCopy of service report or work order\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"5924\" data-end=\"5971\"\u003eIncomplete or late submissions may be rejected.\u003c\/p\u003e\n\u003ch2 data-start=\"5978\" data-end=\"6021\"\u003eWarranty Parts, Replacements \u0026amp; Returns\u003c\/h2\u003e\n\u003cp data-start=\"6023\" data-end=\"6207\"\u003eThe manufacturer reserves the right to \u003cstrong data-start=\"6062\" data-end=\"6083\"\u003erepair or replace\u003c\/strong\u003e defective units or components. Replacement parts may be invoiced pending return of defective items and inspection approval.\u003c\/p\u003e\n\u003cp data-start=\"6209\" data-end=\"6229\"\u003eAll returns require:\u003c\/p\u003e\n\u003cul data-start=\"6230\" data-end=\"6362\"\u003e\n\u003cli data-start=\"6230\" data-end=\"6254\"\u003e\n\u003cp data-start=\"6232\" data-end=\"6254\"\u003eA valid \u003cstrong data-start=\"6240\" data-end=\"6254\"\u003eRMA number\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"6255\" data-end=\"6281\"\u003e\n\u003cp data-start=\"6257\" data-end=\"6281\"\u003eFreight prepaid shipment\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"6282\" data-end=\"6362\"\u003e\n\u003cp data-start=\"6284\" data-end=\"6362\"\u003eComplete documentation of failure and requested action (credit or replacement)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"6364\" data-end=\"6477\"\u003eReplacement parts are covered by a \u003cstrong data-start=\"6399\" data-end=\"6438\"\u003eninety (90) day parts-only warranty\u003c\/strong\u003e from shipment date. Labor is excluded.\u003c\/p\u003e\n\u003ch2 data-start=\"6484\" data-end=\"6509\"\u003eNon-Warranty Repairs\u003c\/h2\u003e\n\u003cp data-start=\"6511\" data-end=\"6680\"\u003eNon-warranty repairs are performed on a \u003cstrong data-start=\"6551\" data-end=\"6579\"\u003etime and materials basis\u003c\/strong\u003e at the prevailing service rate, with a one (1) hour minimum. Estimates may be provided upon request.\u003c\/p\u003e\n\u003cp data-start=\"6682\" data-end=\"6763\"\u003eRepairs are warranted for \u003cstrong data-start=\"6708\" data-end=\"6728\"\u003eninety (90) days\u003c\/strong\u003e and limited to the parts replaced.\u003c\/p\u003e\n\u003ch2 data-start=\"6770\" data-end=\"6789\"\u003eParts Ordering\u003c\/h2\u003e\n\u003cp data-start=\"6791\" data-end=\"7015\"\u003eWhen ordering parts, the \u003cstrong data-start=\"6816\" data-end=\"6852\"\u003ecorrect manufacturer part number\u003c\/strong\u003e is required. Serial number verification may be necessary to ensure compatibility. Incorrect or trial-installed parts may be subject to restocking or testing fees.\u003c\/p\u003e\n\u003ch2 data-start=\"7022\" data-end=\"7038\"\u003eRMA Process\u003c\/h2\u003e\n\u003cp data-start=\"7040\" data-end=\"7242\"\u003eAn \u003cstrong data-start=\"7043\" data-end=\"7069\"\u003eRMA number is required\u003c\/strong\u003e for all returns, credits, or warranty replacements. RMA numbers are valid for \u003cstrong data-start=\"7148\" data-end=\"7165\"\u003esix (6) weeks\u003c\/strong\u003e from issuance. Returns received without proper authorization may be refused.\u003c\/p\u003e\n\u003cp data-start=\"7244\" data-end=\"7314\"\u003eIssuance of an RMA does \u003cstrong data-start=\"7268\" data-end=\"7313\"\u003enot guarantee credit or warranty approval\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 data-start=\"7244\" data-end=\"7314\"\u003eProduct FAQs\u003c\/h3\u003e\n\u003cp\u003eN\/A\u003c\/p\u003e\n\u003c!--- cis2:m2lsnZdp ---\u003e","brand":"Furuno","offers":[{"title":"Default Title","offer_id":51525244027163,"sku":"OGL-65924","price":1195.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0724\/2026\/2171\/files\/65924XL.jpg?v=1766515395"},{"product_id":"victron-orion-24-12-30-dc-dc-converter-ip20-ori241230022","title":"Victron Orion 24\/12-30 DC-DC Converter IP20 [ORI241230022]","description":"\u003ch2\u003e\u003cspan style=\"text-decoration: underline;\"\u003eVictron Orion 24\/12-30 DC-DC Converter IP20 [ORI241230022]\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch2\u003eDescription\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eOrion 24\/12-30 DC-DC Converter IP20\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eRemote on\/off connector\u003c\/p\u003e\n\u003cp\u003eThe remote on\/off eliminates the need for a high-current switch in the input wiring. The remote on-off can be operated with a low-power switch or by the engine run\/stop switch (see manual).\u003c\/p\u003e\n\u003cp\u003eAll models with adjustable output can also be used as a battery charger. For example, to charge a 12 Volt starter or accessory battery in an otherwise 24V system.\u003c\/p\u003e\n\u003cp\u003eAll models with adjustable output can be paralleled to increase the output current. Up to five units can be connected in parallel.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePlease contact your dealer for any returns, repairs or support issues related to this product.\u003c\/strong\u003e\u003c\/p\u003e\n\u003c!--- cis2:m2lsnZdp ---\u003e\n\u003ch3\u003eProduct Specifications\u003c\/h3\u003e\n\u003ch2\u003e\u003cspan style=\"text-decoration: underline;\"\u003eVictron Orion 24\/12-30 DC-DC Converter IP20 [ORI241230022] \u003cmeta charset=\"utf-8\"\u003eProduct Specifications\u003c\/span\u003e\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Name\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eVictron Orion 24\/12-30 DC-DC Converter IP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eORI241230022\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConverter Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDC-DC Converter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12V DC (Adjustable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIngress Protection Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRemote On\/Off\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRemote Switching Method\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLow-power switch or engine run\/stop switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBattery Charging Capability\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes, adjustable output models can be used as a battery charger\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eParallel Operation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Parallel Units\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUp to 5 units\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Voltage Adjustment\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAdjustable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCharging a 12V starter or accessory battery from a 24V system\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eVictron Energy\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eProduct Manual\u003c\/h3\u003e\n\u003ch4\u003e\u003ca href=\"https:\/\/productimageserver.com\/literature\/quickGuide\/112824QG.pdf\" target=\"_blank\"\u003eQuick Guide (pdf)\u003c\/a\u003e\u003c\/h4\u003e\n\u003ch3\u003eProduct Warranty\u003c\/h3\u003e\n\u003ch2\u003e\u003cspan style=\"text-decoration: underline;\"\u003eVictron Energy Product Warranty\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cmeta charset=\"utf-8\"\u003eVictron Energy warrants its products to be free from defects in workmanship and materials for a period of 5 years from the date of purchase by the end-user, with a maximum of 66 months from the Victron Energy invoice date. Exceptions on this are: lead-acid batteries; 2 years from date of purchase by the end-user, with a maximum of 30 months from the Victron Energy invoice date, Lithium batteries; 3 years from date of purchase by the end-user. In addition to this, proof of correct battery usage is required when making a battery warranty claim.\u003c\/p\u003e\n\u003cp\u003eFor a 10% surcharge on the net price for products that came with a 5-year warranty, an additional 5 years of warranty can be purchased, bringing the total warranty to 10 years. Warranty extensions need to be applied for ultimately one year before expiration of the original term.\u003c\/p\u003e\n\u003cp\u003eDuring the warranty period, Victron Energy will, at its discretion, repair, replace or credit the defective product free of charge. The warranty does not include performing or reimbursing de‐installation, transportation, and re‐installation. This warranty will be considered void if the unit has suffered any physical damage or alteration, either internally or externally, and does not cover damages arising from improper use like:\u003c\/p\u003e\n\u003cp\u003e• Reverse of battery polarity.\u003c\/p\u003e\n\u003cp\u003e• Inadequate connection.\u003c\/p\u003e\n\u003cp\u003e• Mechanical shock or deformation.\u003c\/p\u003e\n\u003cp\u003e• Contact with liquid or oxidation by condensation.\u003c\/p\u003e\n\u003cp\u003e• Use in an inappropriate environment(dust, corrosive vapor, humidity, high temperature, biological infestation...). \u003c\/p\u003e\n\u003cp\u003e• Breakage or damage due to lightning.\u003c\/p\u003e\n\u003cp\u003e• Connection terminals and screws destroyed or other damages, like overheat, due to insufficient tightening.\u003c\/p\u003e\n\u003cp\u003e• For any electronic breakage except due to lightning (reverse polarity, over‐voltage due to external cause), the state of the internal control diode and\/or the input\/output X and Y capacitors determine the warranty.\u003c\/p\u003e\n\u003cp\u003eThis warranty will not apply where the product has been misused, neglected, improperly installed, or repaired by anyone else than Victron Energy or one of its authorized Repair Centres. In order to qualify for the warranty, the product must not be disassembled or modified.\u003c\/p\u003e\n\u003cp\u003eRepair, replacement or credit are our sole remedies and Victron Energy shall not be liable for damages, whether direct, incidental, special, or consequential, even caused by negligence or fault.\u003c\/p\u003e\n\u003cp\u003eVictron Energy owns all parts removed from repaired products. Victron Energy uses new or reconditioned parts made by various manufacturers when performing warranty repairs or building replacement products. If Victron Energy repairs or replaces a part of a product, its warranty term is not extended.\u003c\/p\u003e\n\u003cp\u003eAll remedies and the measure for damages are limited to the above.\u003c\/p\u003e\n\u003cp\u003eVictron Energy shall in no event be liable for consequential, incidental, contingent or special damages, even if having been advised of the probability of such damages. Any and all other warranties expressed or implied arising by law, course of dealing, course of performance, usage of trade or otherwise, including but not limited to implied warranties of merchantability and fitness for a particular purpose, are limited in duration to a period of five (5) years from the date of purchase, with the exception of batteries. For lead acid batteries a two (2) year period applies and for lithium batteries a three (3) year period applies.\u003c\/p\u003e\n\u003ch3\u003eProduct FAQs\u003c\/h3\u003e\n\u003cp\u003eN\/A\u003c\/p\u003e","brand":"Victron Energy","offers":[{"title":"Default Title","offer_id":51777924727067,"sku":"OGL-112824","price":76.5,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0724\/2026\/2171\/files\/112824XL.jpg?v=1771007956"},{"product_id":"victron-orion-24-12-60-dc-dc-converter-ip20-ori241260020","title":"Victron Orion 24\/12-60 DC-DC Converter IP20 [ORI241260020]","description":"\u003ch2\u003e\u003cspan style=\"text-decoration: underline;\"\u003eVictron Orion 24\/12-60 DC-DC Converter IP20 [ORI241260020]\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch2\u003eDescription\u003c\/h2\u003e\n\u003cp id=\"isPasted\"\u003e\u003cstrong\u003eOrion 24\/12-60 DC-DC Converter IP20\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eRemote on\/off connector\u003c\/p\u003e\n\u003cp\u003eThe remote on\/off eliminates the need for a high-current switch in the input wiring. The remote on-off can be operated with a low-power switch or by the engine run\/stop switch (see manual).\u003c\/p\u003e\n\u003cp\u003eAll models with adjustable output can also be used as a battery charger. For example, to charge a 12 Volt starter or accessory battery in an otherwise 24V system.\u003c\/p\u003e\n\u003cp\u003eAll models with adjustable output can be paralleled to increase the output current. Up to five units can be connected in parallel.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePlease contact your dealer for any returns, repairs or support issues related to this product. \u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003eProduct Specifications\u003c\/h3\u003e\n\u003c!--- cis2:m2lsnZdp ---\u003e\n\u003ch2\u003e\u003cspan style=\"text-decoration: underline;\"\u003eVictron Orion 24\/12-60 DC-DC Converter IP20 [ORI241260020] \u003cmeta charset=\"utf-8\"\u003eProduct Specifications\u003c\/span\u003e\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Name\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eVictron Orion 24\/12-60 DC-DC Converter IP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eORI241260020\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConverter Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDC-DC Converter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12V DC (Adjustable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e60A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIngress Protection Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRemote On\/Off\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRemote Switching Method\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLow-power switch or engine run\/stop switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBattery Charging Capability\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes, adjustable output models can be used as a battery charger\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eParallel Operation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Parallel Units\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUp to 5 units\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Voltage Adjustment\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAdjustable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCharging a 12V starter or accessory battery from a 24V system\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eVictron Energy\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eProduct Manual\u003c\/h3\u003e\n\u003ch4\u003e\u003ca href=\"https:\/\/productimageserver.com\/literature\/quickGuide\/112825QG.pdf\" target=\"_blank\"\u003eQuick Guide (pdf)\u003c\/a\u003e\u003c\/h4\u003e\n\u003ch3\u003eProduct Warranty\u003c\/h3\u003e\n\u003ch2\u003e\u003cspan style=\"text-decoration: underline;\"\u003eVictron Energy Product Warranty\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cmeta charset=\"utf-8\"\u003eVictron Energy warrants its products to be free from defects in workmanship and materials for a period of 5 years from the date of purchase by the end-user, with a maximum of 66 months from the Victron Energy invoice date. Exceptions on this are: lead-acid batteries; 2 years from date of purchase by the end-user, with a maximum of 30 months from the Victron Energy invoice date, Lithium batteries; 3 years from date of purchase by the end-user. In addition to this, proof of correct battery usage is required when making a battery warranty claim.\u003c\/p\u003e\n\u003cp\u003eFor a 10% surcharge on the net price for products that came with a 5-year warranty, an additional 5 years of warranty can be purchased, bringing the total warranty to 10 years. Warranty extensions need to be applied for ultimately one year before expiration of the original term.\u003c\/p\u003e\n\u003cp\u003eDuring the warranty period, Victron Energy will, at its discretion, repair, replace or credit the defective product free of charge. The warranty does not include performing or reimbursing de‐installation, transportation, and re‐installation. This warranty will be considered void if the unit has suffered any physical damage or alteration, either internally or externally, and does not cover damages arising from improper use like:\u003c\/p\u003e\n\u003cp\u003e• Reverse of battery polarity.\u003c\/p\u003e\n\u003cp\u003e• Inadequate connection.\u003c\/p\u003e\n\u003cp\u003e• Mechanical shock or deformation.\u003c\/p\u003e\n\u003cp\u003e• Contact with liquid or oxidation by condensation.\u003c\/p\u003e\n\u003cp\u003e• Use in an inappropriate environment(dust, corrosive vapor, humidity, high temperature, biological infestation...). \u003c\/p\u003e\n\u003cp\u003e• Breakage or damage due to lightning.\u003c\/p\u003e\n\u003cp\u003e• Connection terminals and screws destroyed or other damages, like overheat, due to insufficient tightening.\u003c\/p\u003e\n\u003cp\u003e• For any electronic breakage except due to lightning (reverse polarity, over‐voltage due to external cause), the state of the internal control diode and\/or the input\/output X and Y capacitors determine the warranty.\u003c\/p\u003e\n\u003cp\u003eThis warranty will not apply where the product has been misused, neglected, improperly installed, or repaired by anyone else than Victron Energy or one of its authorized Repair Centres. In order to qualify for the warranty, the product must not be disassembled or modified.\u003c\/p\u003e\n\u003cp\u003eRepair, replacement or credit are our sole remedies and Victron Energy shall not be liable for damages, whether direct, incidental, special, or consequential, even caused by negligence or fault.\u003c\/p\u003e\n\u003cp\u003eVictron Energy owns all parts removed from repaired products. Victron Energy uses new or reconditioned parts made by various manufacturers when performing warranty repairs or building replacement products. If Victron Energy repairs or replaces a part of a product, its warranty term is not extended.\u003c\/p\u003e\n\u003cp\u003eAll remedies and the measure for damages are limited to the above.\u003c\/p\u003e\n\u003cp\u003eVictron Energy shall in no event be liable for consequential, incidental, contingent or special damages, even if having been advised of the probability of such damages. Any and all other warranties expressed or implied arising by law, course of dealing, course of performance, usage of trade or otherwise, including but not limited to implied warranties of merchantability and fitness for a particular purpose, are limited in duration to a period of five (5) years from the date of purchase, with the exception of batteries. For lead acid batteries a two (2) year period applies and for lithium batteries a three (3) year period applies.\u003c\/p\u003e\n\u003ch3\u003eProduct FAQs\u003c\/h3\u003e\n\u003cp\u003eN\/A\u003c\/p\u003e","brand":"Victron Energy","offers":[{"title":"Default Title","offer_id":51777924759835,"sku":"OGL-112825","price":106.25,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0724\/2026\/2171\/files\/112825XL.jpg?v=1771007957"},{"product_id":"victron-orion-24-12-80-dc-dc-converter-ip20-ori241280020","title":"Victron Orion 24\/12-80 DC-DC Converter IP20 [ORI241280020]","description":"\u003ch2\u003e\u003cspan style=\"text-decoration: underline;\"\u003eVictron Orion 24\/12-80 DC-DC Converter IP20 [ORI241280020]\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch2\u003eDescription\u003c\/h2\u003e\n\u003cp id=\"isPasted\"\u003e\u003cstrong\u003eOrion 24\/12-80 DC-DC Converter IP20\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eRemote on\/off connector\u003c\/p\u003e\n\u003cp\u003eThe remote on\/off eliminates the need for a high-current switch in the input wiring. The remote on-off can be operated with a low-power switch or by the engine run\/stop switch (see manual).\u003c\/p\u003e\n\u003cp\u003eAll models with adjustable output can also be used as a battery charger. For example, to charge a 12 Volt starter or accessory battery in an otherwise 24V system.\u003c\/p\u003e\n\u003cp\u003eAll models with adjustable output can be paralleled to increase the output current. Up to five units can be connected in parallel.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePlease contact your dealer for any returns, repairs or support issues related to this product.\u003c\/strong\u003e\u003c\/p\u003e\n\u003c!--- cis2:m2lsnZdp ---\u003e\n\u003ch3\u003e\u003cspan style=\"text-decoration: underline;\"\u003eProduct Specifiations\u003c\/span\u003e\u003c\/h3\u003e\n\u003ch2\u003e\n\u003cspan style=\"text-decoration: underline;\"\u003eVictron Orion 24\/12-80 DC-DC Converter IP20 [ORI241280020] \u003cmeta charset=\"utf-8\"\u003e\u003c\/span\u003e\u003cspan style=\"text-decoration: underline;\"\u003eProduct Specifiations\u003c\/span\u003e\n\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Name\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eVictron Orion 24\/12-80 DC-DC Converter IP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eORI241280020\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConverter Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDC-DC Converter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12V DC (Adjustable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e80A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIngress Protection Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRemote On\/Off\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRemote Switching Method\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eLow-power switch or engine run\/stop switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBattery Charging Capability\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes, adjustable output models can be used as a battery charger\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eParallel Operation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Parallel Units\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUp to 5 units\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Voltage Adjustment\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAdjustable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCharging a 12V starter or accessory battery from a 24V system\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eVictron Energy\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eProduct Manual\u003c\/h3\u003e\n\u003ch4\u003e\u003ca href=\"https:\/\/productimageserver.com\/literature\/quickGuide\/112826QG.pdf\" target=\"_blank\"\u003eQuick Guide (pdf)\u003c\/a\u003e\u003c\/h4\u003e\n\u003ch3\u003eProduct Warranty\u003c\/h3\u003e\n\u003ch2\u003e\u003cspan style=\"text-decoration: underline;\"\u003eVictron Energy Product Warranty\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cmeta charset=\"utf-8\"\u003eVictron Energy warrants its products to be free from defects in workmanship and materials for a period of 5 years from the date of purchase by the end-user, with a maximum of 66 months from the Victron Energy invoice date. Exceptions on this are: lead-acid batteries; 2 years from date of purchase by the end-user, with a maximum of 30 months from the Victron Energy invoice date, Lithium batteries; 3 years from date of purchase by the end-user. In addition to this, proof of correct battery usage is required when making a battery warranty claim.\u003c\/p\u003e\n\u003cp\u003eFor a 10% surcharge on the net price for products that came with a 5-year warranty, an additional 5 years of warranty can be purchased, bringing the total warranty to 10 years. Warranty extensions need to be applied for ultimately one year before expiration of the original term.\u003c\/p\u003e\n\u003cp\u003eDuring the warranty period, Victron Energy will, at its discretion, repair, replace or credit the defective product free of charge. The warranty does not include performing or reimbursing de‐installation, transportation, and re‐installation. This warranty will be considered void if the unit has suffered any physical damage or alteration, either internally or externally, and does not cover damages arising from improper use like:\u003c\/p\u003e\n\u003cp\u003e• Reverse of battery polarity.\u003c\/p\u003e\n\u003cp\u003e• Inadequate connection.\u003c\/p\u003e\n\u003cp\u003e• Mechanical shock or deformation.\u003c\/p\u003e\n\u003cp\u003e• Contact with liquid or oxidation by condensation.\u003c\/p\u003e\n\u003cp\u003e• Use in an inappropriate environment(dust, corrosive vapor, humidity, high temperature, biological infestation...). \u003c\/p\u003e\n\u003cp\u003e• Breakage or damage due to lightning.\u003c\/p\u003e\n\u003cp\u003e• Connection terminals and screws destroyed or other damages, like overheat, due to insufficient tightening.\u003c\/p\u003e\n\u003cp\u003e• For any electronic breakage except due to lightning (reverse polarity, over‐voltage due to external cause), the state of the internal control diode and\/or the input\/output X and Y capacitors determine the warranty.\u003c\/p\u003e\n\u003cp\u003eThis warranty will not apply where the product has been misused, neglected, improperly installed, or repaired by anyone else than Victron Energy or one of its authorized Repair Centres. In order to qualify for the warranty, the product must not be disassembled or modified.\u003c\/p\u003e\n\u003cp\u003eRepair, replacement or credit are our sole remedies and Victron Energy shall not be liable for damages, whether direct, incidental, special, or consequential, even caused by negligence or fault.\u003c\/p\u003e\n\u003cp\u003eVictron Energy owns all parts removed from repaired products. Victron Energy uses new or reconditioned parts made by various manufacturers when performing warranty repairs or building replacement products. If Victron Energy repairs or replaces a part of a product, its warranty term is not extended.\u003c\/p\u003e\n\u003cp\u003eAll remedies and the measure for damages are limited to the above.\u003c\/p\u003e\n\u003cp\u003eVictron Energy shall in no event be liable for consequential, incidental, contingent or special damages, even if having been advised of the probability of such damages. Any and all other warranties expressed or implied arising by law, course of dealing, course of performance, usage of trade or otherwise, including but not limited to implied warranties of merchantability and fitness for a particular purpose, are limited in duration to a period of five (5) years from the date of purchase, with the exception of batteries. For lead acid batteries a two (2) year period applies and for lithium batteries a three (3) year period applies.\u003c\/p\u003e\n\u003ch3\u003eProduct FAQs\u003c\/h3\u003e\n\u003cp\u003eN\/A\u003c\/p\u003e","brand":"Victron Energy","offers":[{"title":"Default Title","offer_id":51777924792603,"sku":"OGL-112826","price":127.5,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0724\/2026\/2171\/files\/112826XL.jpg?v=1771007957"},{"product_id":"victron-orion-tr-12-24-15a-360w-isolated-dc-dc-converter-ori122441110","title":"Victron Orion-Tr 12\/24-15A (360W) Isolated DC-DC Converter [ORI122441110]","description":"\u003ch2\u003e\u003cspan style=\"text-decoration: underline;\"\u003eVictron Orion-Tr 12\/24-15A (360W) Isolated DC-DC Converter [ORI122441110]\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch2\u003eDescription\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eOrion-Tr 12\/24-15A (360W) Isolated DC-DC Converter\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli data-pasted=\"true\"\u003eRemote on\/off terminal - The remote on\/off terminal eliminates the need for a high-current switch in the input wiring. The remote on\/off can be operated with a low power switch or by, for example, the engine run\/stop switch (see manual).\u003c\/li\u003e\n\u003cli\u003eAll models are short-circuit proof and can be paralleled to increase output current. An unlimited number of units can be connected in parallel.\u003c\/li\u003e\n\u003cli\u003eHigh temperature protected - The output current will reduce at high ambient temperature.\u003c\/li\u003e\n\u003cli\u003eIP43 protection - When installed with the screw terminals oriented downwards.\u003c\/li\u003e\n\u003cli\u003eScrew terminals - No special tools needed for installation.\u003c\/li\u003e\n\u003cli\u003eInput fuse (not replaceable) - On 12 V and 24 V input models only.\u003c\/li\u003e\n\u003cli\u003eAdjustable output voltage - Not intended for battery charging. Please consider using an Orion-Tr Smart for battery charging.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!--- cis2:m2lsnZdp ---\u003e\n\u003ch3\u003eProduct Specification\u003c\/h3\u003e\n\u003ch2\u003e\u003cspan style=\"text-decoration: underline;\"\u003eVictron Orion-Tr 12\/24-15A (360W) Isolated DC-DC Converter [ORI122441110] \u003cmeta charset=\"utf-8\"\u003eProduct Specification\u003c\/span\u003e\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Name\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eVictron Orion-Tr 12\/24-15A (360W) Isolated DC-DC Converter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eORI122441110\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConverter Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIsolated DC-DC Converter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24V DC (Adjustable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e360W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIsolation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGalvanically Isolated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRemote On\/Off\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes, via low-power remote terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eParallel Operation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes, unlimited units can be connected in parallel to increase output current\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShort-Circuit Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHigh-Temperature Protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes, output current reduces automatically at high ambient temperatures\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIngress Protection Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP43 (when installed with screw terminals facing downward)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnection Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eScrew terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInstallation Requirements\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNo special tools required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Fuse\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBuilt-in, non-replaceable (on 12V and 24V input models only)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput Voltage Adjustment\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAdjustable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBattery Charging Capability\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNot intended for battery charging\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRecommended Alternative for Battery Charging\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eVictron Orion-Tr Smart Series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eProduct Manual\u003c\/h3\u003e\n\u003ch4\u003e\u003ca href=\"https:\/\/productimageserver.com\/literature\/brochure\/110634BR.pdf\" target=\"_blank\"\u003eBrochure (pdf)\u003c\/a\u003e\u003c\/h4\u003e\n\u003ch3\u003eProduct Warranty\u003c\/h3\u003e\n\u003ch2\u003e\u003cspan style=\"text-decoration: underline;\"\u003eVictron Energy Product Warranty\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cmeta charset=\"utf-8\"\u003eVictron Energy warrants its products to be free from defects in workmanship and materials for a period of 5 years from the date of purchase by the end-user, with a maximum of 66 months from the Victron Energy invoice date. Exceptions on this are: lead-acid batteries; 2 years from date of purchase by the end-user, with a maximum of 30 months from the Victron Energy invoice date, Lithium batteries; 3 years from date of purchase by the end-user. In addition to this, proof of correct battery usage is required when making a battery warranty claim.\u003c\/p\u003e\n\u003cp\u003eFor a 10% surcharge on the net price for products that came with a 5-year warranty, an additional 5 years of warranty can be purchased, bringing the total warranty to 10 years. Warranty extensions need to be applied for ultimately one year before expiration of the original term.\u003c\/p\u003e\n\u003cp\u003eDuring the warranty period, Victron Energy will, at its discretion, repair, replace or credit the defective product free of charge. The warranty does not include performing or reimbursing de‐installation, transportation, and re‐installation. This warranty will be considered void if the unit has suffered any physical damage or alteration, either internally or externally, and does not cover damages arising from improper use like:\u003c\/p\u003e\n\u003cp\u003e• Reverse of battery polarity.\u003c\/p\u003e\n\u003cp\u003e• Inadequate connection.\u003c\/p\u003e\n\u003cp\u003e• Mechanical shock or deformation.\u003c\/p\u003e\n\u003cp\u003e• Contact with liquid or oxidation by condensation.\u003c\/p\u003e\n\u003cp\u003e• Use in an inappropriate environment(dust, corrosive vapor, humidity, high temperature, biological infestation...). \u003c\/p\u003e\n\u003cp\u003e• Breakage or damage due to lightning.\u003c\/p\u003e\n\u003cp\u003e• Connection terminals and screws destroyed or other damages, like overheat, due to insufficient tightening.\u003c\/p\u003e\n\u003cp\u003e• For any electronic breakage except due to lightning (reverse polarity, over‐voltage due to external cause), the state of the internal control diode and\/or the input\/output X and Y capacitors determine the warranty.\u003c\/p\u003e\n\u003cp\u003eThis warranty will not apply where the product has been misused, neglected, improperly installed, or repaired by anyone else than Victron Energy or one of its authorized Repair Centres. In order to qualify for the warranty, the product must not be disassembled or modified.\u003c\/p\u003e\n\u003cp\u003eRepair, replacement or credit are our sole remedies and Victron Energy shall not be liable for damages, whether direct, incidental, special, or consequential, even caused by negligence or fault.\u003c\/p\u003e\n\u003cp\u003eVictron Energy owns all parts removed from repaired products. Victron Energy uses new or reconditioned parts made by various manufacturers when performing warranty repairs or building replacement products. If Victron Energy repairs or replaces a part of a product, its warranty term is not extended.\u003c\/p\u003e\n\u003cp\u003eAll remedies and the measure for damages are limited to the above.\u003c\/p\u003e\n\u003cp\u003eVictron Energy shall in no event be liable for consequential, incidental, contingent or special damages, even if having been advised of the probability of such damages. Any and all other warranties expressed or implied arising by law, course of dealing, course of performance, usage of trade or otherwise, including but not limited to implied warranties of merchantability and fitness for a particular purpose, are limited in duration to a period of five (5) years from the date of purchase, with the exception of batteries. For lead acid batteries a two (2) year period applies and for lithium batteries a three (3) year period applies.\u003c\/p\u003e\n\u003ch3\u003eProduct FAQs\u003c\/h3\u003e\n\u003cp\u003eN\/A\u003c\/p\u003e","brand":"Victron Energy","offers":[{"title":"Default Title","offer_id":52237775470875,"sku":"OGL-110634","price":201.45,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0724\/2026\/2171\/files\/110634XL.jpg?v=1779305662"}],"url":"https:\/\/www.offgridlivingsolutions.com\/collections\/dc-to-dc-converters.oembed","provider":"OffGrid Living","version":"1.0","type":"link"}